• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude et développement d'une mesure pyrométrique en cœur de réacteur pour le suivi de la température d'une gaine de combustible : application à l'étude des accidents de perte de réfrigérant primaire (APRP) au cours d'essais de simulation dans le réacteur expérimental Jules Horowitz. / Study and development of a nuclear in core pyrometry measure for a fuel rod temperature tracking : application to Loss of Coolant Accident (LOCA) in simulating tests for the Materials Testings Reactor Jules Horowitz.

Ramiandrisoa, Liana 01 July 2014 (has links)
Dans l'industrie comme dans la Recherche, la température est un paramètre clef pour la maîtrise et la compréhension du comportement des matériaux. Ainsi, dans le Réacteur nucléaire de Recherche Jules Horowitz (RJH), actuellement en construction au CEA Cadarache, un dispositif expérimental est élaboré afin d'étudier le comportement thermomécanique d'une gaine combustible. Celle-ci sera placée dans des conditions qui simulent une situation accidentelle (Accident de Perte de Réfrigérant Primaire, APRP) pendant laquelle elle s'échauffera rapidement. Le suivi de température, entre 700 et 1200 à ±10°C, doit pouvoir se faire par un capteur pyrométrique déporté par fibre optique. L'enjeu est d'optimiser la mesure en comparant différentes techniques de pyrométrie. Pour cela, l'étude est menée sous l'angle des deux principales difficultés techniques inhérentes à la réalisation du capteur. Le premier défi est lié au comportement des fibres optiques dans un environnement mixte où irradiation et haute température sont intimement liées. La fibre va subir des flux neutroniques de l'ordre de 10^12 nrapide/cm²/s et un débit de dose d'environ 1kGy/s. De plus son extrémité est soumise à une température de paroi élevée, de l'ordre de 800°C. Dans ces conditions, lumières parasites, bandes d'absorption et atténuation fluctuante sont autant de contraintes dont les effets sont à éviter ou à minimiser. Une étude prédictive fait le point sur les recommandations théoriques à suivre pour une mesure optimale.La seconde difficulté, qui concerne la mesure de température par pyrométrie, vient des variations spectrales attendues pour l'émissivité de la cible. Le matériau d'étude, choisi pour son utilisation dominante en France, est le Zircaloy-4. Sous l'effet de l'oxydation, l'émissivité spectrale de cet alliage de Zirconium évolue. Ce manuscrit montre qu'entre 700 et 800°C il est expérimentalement possible d'effectuer une mesure pyrométrique en laboratoire, hors irradiation.En croisant ces différents résultats, il apparaît envisageable d'effectuer une mesure de température dans les conditions du RJH à condition de maîtriser les différents paramètres parasites et de privilégier certaines longueurs d'onde. Ce travail s'inscrit dans une voie prometteuse pour l'utilisation à distance de la pyrométrie optique en milieu nucléaire civil sévère. / In both research and industry, temperature is a key parameter for understanding and characterizing the behavior of materials. To study the thermomechanical behavior of a fuel rod, a test device is designed for the Jules Horowitz Material Testing Reactor (currently under construction in the CEA Cadarache). The device will be placed under accidental conditions (Loss Of Coolant Accident, LOCA) causing rapid overheating. The temperature tracking, between 700 and 1200°C, will be measured by a fiber optic sensor. The aim of the project is to optimize temperature measurement by comparing different pyrometry techniques. This study covers the management of the main difficulties inherent to the design of the sensor.The first challenge consists of predicting optical fiber behavior in such complex environments where irradiation and high temperature are combined. The fiber will be exposed to a neutron dose rate about 10^12 nfast/cm²/s and ϒ dose rate of about 1kGy/s. Moreover its extremity is heated to approximately 800°C. It is shown that under these conditions, light interferences, absorption bands and fluctuating attenuation are obstacles to overcome or to mitigate.The second challenge, concerning pyrometric measurement, comes from spectral variations expected for the rod emissivity. The material of study is chosen for its widespread use in France: Zircaloy-4. Under oxidating conditions the spectral emissivity of this Zirconium alloy evolves. This thesis proves that between 700 and 800°C pyrometric measurement is possible from experimental point of view in laboratory without irradiation.In conclusion rod temperature tracking in JHR conditions may be possible providing that interferences are mastered and wavelengths are chosen. This work makes the use of optical pyrometry under civil nuclear extreme conditions more promising.
2

Développement d'optiques multicouches pour la spectrométrie X large bande du rayonnement émis par les plasmas / Development of multilayer optics for X-ray broadband spectrometry of plasma emission

Emprin, Benoit 28 November 2014 (has links)
Dans le cadre de ses recherches menées sur la fusion par confinement inertiel, le Commissariat à l’énergie atomique et aux énergies alternatives met en œuvre un spectromètre X large bande étalonné en absolu et résolu en temps, appelé Diagnostic de Mesure du rayonnement X. Ce diagnostic, composé de 20 voies de mesure, permet de mesurer l’émissivité spectrale d’un plasma créé par laser entre 50 eV et 20 keV. Nous avons développé des voies de mesure complémentaires aux voies existantes, afin d’obtenir une redondance et une amélioration de la précision de la mesure. Le principe de ces nouvelles voies de mesure repose sur un concept original permettant d’obtenir des fonctions de transfert spectrales bornées et constantes. Deux voies ont été développées pour les gammes spectrales 2 – 4 keV et 4 – 6 keV, utilisant des miroirs multicouches apériodiques réalisés au Laboratoire Charles Fabry en Cr/Sc et Ni/W/SiC/W, respectivement. Ces miroirs ont ensuite été caractérisés sur synchrotrons puis intégrés dans le spectromètre. Les nouvelles voies ont été utilisées durant des campagnes d’expériences laser-Plasma sur l’installation laser OMEGA à Rochester (États-Unis). Elles ont permis de déterminer la puissance rayonnée directement avec une seule voie de mesure par bande spectrale et avec une meilleure précision qu’avec celles utilisées habituellement. Les résultats, en bon accord avec les voies de mesure classiques, permettent de valider l’utilisation des miroirs multicouches apériodiques pour la spectrométrie X large bande. / Within the framework of the research on inertial confinement fusion, the “Commissariat à l’énergie atomique et aux énergies alternatives” has studied and implemented an absolute calibrated time-Resolved broadband soft x-Ray spectrometer, called “Diagnostic de Mesure du rayonnement X”. This diagnostic, composed of 20 measurement channels, measures the emitted radiant power from a laser created plasma in the range from 50 eV to 20 keV. We have developed additional measurement channels to obtain redundancy and an improvement in measurement accuracy. The principle of these new channels is based on an original concept to obtain spectral bounded flat-Responses. Two channels have been developed for the 2 – 4 keV and 4 – 6 keV spectral ranges, using aperiodic multilayer mirrors made at the “Laboratoire Charles Fabry” with Cr/Sc and Ni/W/SiC/W layers respectively. These mirrors were characterized at synchrotron radiation facilities and integrated into the spectrometer. The two new channels were used during laser-Plasma experimental campaigns at the OMEGA laser facility in Rochester (USA). This allowed us to determine directly the radiant power with only one measurement within a certain spectral band, and with a better precision when compared with using standard channels. The results, in good agreement with the standard measurement channels, allowed us to validate the use of aperiodic multilayer mirrors for X-Ray broadband spectrometry.

Page generated in 0.0992 seconds