Medidor de vazão de água, tipo \"Pitot-Cole\", com configuração prismática hexagonal. / Water flow meter, as \"Pilot-Cole\", with hexagonal prismatic configuration.

Siqueira, Natally Annunciato 22 June 2018 (has links)
A medição de vazão é fundamental para a gestão de processos que envolvem fluidos. Em empresas de saneamento, contabilizar as entradas e saídas de água é essencial para gerir faturamentos e perdas. A vazão pode ser mensurada através de diversos instrumentos com diferentes princípios de aplicação. O Tubo Pitot Cole é capaz de determinar a vazão em tubulações através do diferencial de pressão. Trata-se se um equipamento inventado em 1732 por Henri Pitot para determinar a velocidade, e aperfeiçoado por Eduard Cole, em 1896, permitindo sua aplicação em tubulações. As principais vantagens são o baixo custo e fácil instalação, que pode ocorrer com a tubulação em carga. Em contrapartida, a fragilidade e complexidade das suas peças motivaram este trabalho: a elaboração de um instrumento simples e robusto para medir a vazão. Propõe-se a construção de um protótipo com tomadas de pressão instaladas em faces opostas de um prisma hexagonal e a avalia-se a sua viabilidade na medição de vazão. Os resultados mostraram-se promissores dada a estabilidade e forte correlação linear obtida no coeficiente de calibração. / Flow measurements are essential for processes management that include fluids. In water companies, measuring inlets and outlets of water is essential to manage revenue and water losses. The water flow can be measured through different instruments with different application principles. The Pitot Cole Tube is able to determine flow in pipes through the pressure differential. This device was invented in 1732 by Henri Pitot to determine fluid velocity and it was improved by Eduard Cole in 1896, allowing to apply the instrument in pipes. The main advantages are the low cost and easy installation, that may occur with the pipe under load. However, the fragility and complexity of its pieces motivated this study: the construction of a simple and robust instrument to measure the water flow. It is proposed the construction of a prototype with pressure plugs installed on opposite faces of a hexagonal prism, then evaluation of its effectiveness in water flow measurements. The results were promising given the stability obtained in the calibration coefficient.
2

Medidor de vazão de água, tipo \"Pitot-Cole\", com configuração prismática hexagonal. / Water flow meter, as \"Pilot-Cole\", with hexagonal prismatic configuration.

Natally Annunciato Siqueira 22 June 2018 (has links)
A medição de vazão é fundamental para a gestão de processos que envolvem fluidos. Em empresas de saneamento, contabilizar as entradas e saídas de água é essencial para gerir faturamentos e perdas. A vazão pode ser mensurada através de diversos instrumentos com diferentes princípios de aplicação. O Tubo Pitot Cole é capaz de determinar a vazão em tubulações através do diferencial de pressão. Trata-se se um equipamento inventado em 1732 por Henri Pitot para determinar a velocidade, e aperfeiçoado por Eduard Cole, em 1896, permitindo sua aplicação em tubulações. As principais vantagens são o baixo custo e fácil instalação, que pode ocorrer com a tubulação em carga. Em contrapartida, a fragilidade e complexidade das suas peças motivaram este trabalho: a elaboração de um instrumento simples e robusto para medir a vazão. Propõe-se a construção de um protótipo com tomadas de pressão instaladas em faces opostas de um prisma hexagonal e a avalia-se a sua viabilidade na medição de vazão. Os resultados mostraram-se promissores dada a estabilidade e forte correlação linear obtida no coeficiente de calibração. / Flow measurements are essential for processes management that include fluids. In water companies, measuring inlets and outlets of water is essential to manage revenue and water losses. The water flow can be measured through different instruments with different application principles. The Pitot Cole Tube is able to determine flow in pipes through the pressure differential. This device was invented in 1732 by Henri Pitot to determine fluid velocity and it was improved by Eduard Cole in 1896, allowing to apply the instrument in pipes. The main advantages are the low cost and easy installation, that may occur with the pipe under load. However, the fragility and complexity of its pieces motivated this study: the construction of a simple and robust instrument to measure the water flow. It is proposed the construction of a prototype with pressure plugs installed on opposite faces of a hexagonal prism, then evaluation of its effectiveness in water flow measurements. The results were promising given the stability obtained in the calibration coefficient.
3

Aquecimento solar de água e medição individualizada: sistemas para edifícios multifamiliares. / Solar water heating system and individualization: systems for multifamily buildings.

Pimenta, Cristina Cardoso 20 February 2019 (has links)
A matriz energética mundial atual gera inúmeros impactos ambientais e, com isso, fontes de energia alternativas são necessárias para um futuro imediato. Desta forma, a energia solar se apresenta como uma das possíveis alternativas. A energia solar, principalmente quando utilizada para o aquecimento de água, ou seja, na sua forma térmica, não apresenta impactos ambientais durante sua produção e possui um funcionamento simples. Devido aos seus benefícios, sistemas de aquecimento solar de água já são muito utilizados em diversos países e, inclusive, incentivados por leis, como na cidade de São Paulo. Mesmo este sistema já tendo sido muito estudado, quando a sua aplicação é destinada a residências unifamiliares, ainda há algumas lacunas quando se trata da aplicação em residências multifamiliares. Um exemplo de lacuna é a questão da medição individualizada dos sistemas prediais, incluindo da energia solar. Sendo assim, o objetivo da presente pesquisa é encontrar um sistema de aquecimento solar mais apropriado quanto à medição individualizada. Para tanto, são analisados, teoricamente, diferentes sistemas e suas caraterísticas. Além disso, é realizado um estudo de caso para se avaliar as características de um sistema em funcionamento em um edifício localizado na cidade de São Paulo. Utilizando-se da junção dos conhecimentos adquiridos na seção teórica e na seção prática, são simuladas algumas propostas de alternativas do sistema, visando avaliar o comportamento da produção dos mesmos em situações distintas. Ao final é possível identificar que o sistema Solar coletivo com acumulação privado e auxiliar instantâneo privado foi o que atendeu a um maior número dos requisitos gerais de sistemas de aquecimento solar e dos requisitos de individualização, e não apresentou problemas de perdas térmicas significativas, apesar de inovações, vislumbradas para um futuro próximo, terem potencial para elevar ainda mais a qualidade do sistema. / The current global energy matrix generates many environments impacts and, thereby, alternative energy sources are required by an immediate future. Indeed, solar energy is presented as one of the possible alternatives. Solar energy, as more when it heats water, or in other words, when its thermal form is used on the system, does not generate environment impacts during its use and has a simple operation. Due its benefits, solar water heating systems are already widely used in many countries and even encouraged by laws, for example in São Paulo city. Even though this system has already been studied by many scientific researches regarding its application for single family dwellings, there are some gaps when it is related to multifamily dwellings. One example of it is the individualization of the building systems aspect, including the individualization of the solar energy use. Therefore, the aim of this research is find a solar water heating system more appropriated regarding the individualization aspect. Thereunto, different systems from various places are theoretically analyzed by their characteristics. Furthermore, a study case is held to evaluate characteristics of a working system in a residential building located in São Paulo city. Using the junction of both, theoretical and practical studies, some alternative proposals are simulated to evaluate how the production of the systems are in different situations. As a conclusion, it is possible to define the system with a shared solar energy, private boiler and instantaneous auxiliary energy heating as the system that meet a larger number of the general solar heating system requirements and of the individualization requirements and do not have significative thermal loss issues, although, prospected near future innovations have potential to further improve the system.