• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 11
  • 8
  • 8
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de membrana de tubogotejador em função do teor de ferro na água /

Brauer, Rigléia Lima, 1980- January 2014 (has links)
Orientador: Raimundo Leite Cruz / Banca: Antonio Evaldo Klar / Banca: Rodrigo Domingues Barbosa / Banca: Luiz Antonio de Andrade / Banca: Talita Aparecida Pletsch / Resumo: Com o propósito de avaliar o desgaste da membrana de tubogotejadores autocompensantes em função da agua rica em ferro, foi conduzido um experimento na área experimental do Departamento de Engenharia Rural da Universidade Estadual Paulista "Júlio de Mesquita Filho" - Faculdade de Ciências Agronômicas, localizada no município de Botucatu - SP, pelas coordenadas geográficas 22º49'S e 48º25' W, tendo a altitude de 770 m. O ensaio corresponde ao desgaste de membranas de tubogotejadores autocompensantes e foi avaliado o gotejador NaanPC azul da empresa NAANDANJAIN. o experimento foi montado em esquema fatorial 2X13, sendo duas doses de Fe e 13 tempos de funcionamento com três repetições, totalizando 78 parcelas experimentais. Para a condução do ensaio, foram retirados de uma bobina, ao acaso 18 segmentos de 35 m com 44 emissores em média do tubo gotejador para cada linha de gotejadores, o que resultou na avaliação de um total de 396 gotejadores para cada tratamento, sendo a pressão de serviço foi mantida em 150 +_ 15 KPA. A água utilizada no ensaio foi proveniente do lago do Departamento de Engenharia Rural que é comumente utilizado para irrigações de experimentos e, posteriormente foram calculados; vazão média, coeficiente de Variação de Vazão (CVQ), Uniformidade de Distribuição da Agua (C.U.D) e densidade relativa (Rr). Os resultados obtido não apontaram diferença significativa em nenhum dos tratamentos para diferentes doses de ferro. / Abstract: The objective of this study was to evaluate the wear of self-compensating dripline as a functional of membrane water rich in iron, an experiment was conducted in the experimental area of the Departament of Rural Engineering, Universidade Estadual Paulista "Julio de Mesquita Filho" - Faculty of Agricultural Sciences, located in Botucatu - SP by the geographical coordinates 22º 49' and 48°25'W, height 770 m . The test match wear membranes self-compensating dripline, and was rated the dripper NaanPC company NaanDanJain blue. The experiment was a factorial 2x13 scheme, two doses of 13 Fe and run times with three replicates, totaling 78 experimental plots. To conduct the test, were drawn from a coil at random segments of 18 to 35 meters in average emitter 44 dripline for each row of drippers. which resulted in the evaluation of a total o 396 drippers for each treatment. The working pressure was maintained at 150+-15KPa. The water used in used in the assay were from the Lake of the Rural Engineering Department which is commonly used for irrigation experiments. Subsequently were calculated: Flow, Flow Coefficient of Variation (CVQ), Uniformity of Water Distribution (CUD) and relative density (Dr). The results showed no significant difference in any of the treatments at different of iron. / Doutor
2

Avaliação da gestão sustentável dos recursos hídricos na sub-bacia hidrográfica do boi branco, município de Itaí-SP /

Sampaio Neto, Givaldo Dantas, 1987. January 2016 (has links)
Orientador: Rodrigo Máximo Sánchez Román / Coorientador: Leonardo de Barros Pinto / Banca: João Carlos Cury Saad / Banca: Francisca Franciana S. Pereira / Banca: Magno Luiz de Abreu / Banca: Anthony Wellington Almeida Gomes / Resumo: A escassez dos recursos hídricos em decorrência dos fatores climáticos ou pelo aumento de consumo devido a intensidade de algumas atividades, tem gerado conflitos em diversas regiões do Brasil. É o caso de algumas sub-bacias da região do Alto Paranapanema que foram classificadas como críticas, em relação aos recursos hídricos. O objetivo deste trabalho foi avaliar as questões relacionadas aos aspectos de gestão dos recursos hídricos, agricultura irrigada e a participação dos diversos setores de usuários de água da sub-bacia do Boi Branco. A sub-bacia do córrego Boi Branco, tem uma área de drenagem de 80,71 Km², possui 1.148,06 metros de seu trecho médio intermitente, faz parte da sub-bacia 51 Ribeirão das Posse/Rio Paranapanema e abrange os municípios de Itaí e Paranapanema. Foram feitos levantamentos sobre as ferramentas, os instrumentos, a política nacional e do estado de São Paulo, relacionadas a gestão dos recursos hídricos. Realizou-se um levantamento da atual situação dos recursos hídricos na sub-bacia do Boi Branco. Foram aplicados instrumentos de coletas de dados junto aos produtores para levantar a situação dos irrigantes. Se por um lado os grandes consumidores de água do CBH ALPA já possuem suas representações no comitê, falta uma maior presença da sociedade civil, seja através das prefeituras ou por organizações comunitárias. A universidade deve participar do comitê para arbitrar nas decisões de forma imparcial, sem interferência política de nenhum setor de usuário... / Abstract: The scarcity of water resources due to climatic factors or the increase in consumption due to the intensity of some activities has generated conflicts in several regions of Brazil. This is the case of some sub-basins in the Alto Paranapanema region that were classified as critical in relation to water resources. The objective of this study was to evaluate the issues related to the management of water resources, irrigated agriculture and the participation of the different sectors of water users at Boi Branco sub-basin. The watershed of Boi Branco stream has a drainage area of 80.71 km², has 1,148.06 meters of its intermittent average stretch, is part of the 51 Ribeirão das Posse / Rio Paranapanema subbasin and covers the municipalities of Itaí And Paranapanema. Surveys were carried out on tools, instruments, national policy and the São Paulo state related to water resources management. A survey of the current water resources situation in the Boi Branco sub-basin was carried out. Data collection instruments were applied to producers to raise the situation of irrigators. While on the one hand the large water consumers of CBH ALPA already have their representations in the committee, there is a lack of civil society presence, either through city halls or community organizations. The university must participate in the committee to arbitrate in decisions impartially, without political interference from any sector of basin users. The quantitative and qualitative data related to water resources in the basins present inconsistency both in the actual water demand and in the effective availability. There is a need for greater dissemination of the information of the Boi Branco sub-basin together with ... / Doutor
3

Dinâmica do entumpimento de tubos gotejadores sob aplicação de ferro solúvel, sólidos em suspensão e fitoplâncton / Clogging dynamics of driplines under the application of soluble iron, suspended solids and fitoplankton

Carvalho, Lilian Cristina Castro de 01 October 2009 (has links)
Este projeto de pesquisa foi desenvolvido visando quantificar possíveis distúrbios de vazão em emissores gotejadores submetidos à aplicação de ferro solúvel, sólidos em suspensão (partículas de solo) em águas contendo material orgânico (fitoplâncton/algas), com o orifício dos emissores posicionados para baixo e para cima. Foram realizados dois experimentos A e B em um período de 12 meses, utilizando-se 16 modelos de tubos gotejadores novos e 26 modelos de tubos gotejadores em uso, com suas respectivas linhas gotejadoras montadas em uma bancada de ensaios em estrutura metálica localizada no Laboratório de Irrigação, da Escola Superior de Agricultura Luiz de Queiroz - ESALQ/USP. No experimento A realizou-se 4 tratamentos (T1, T2, T3 e T4), divididos em duas fases, onde na fase 1 avaliou-se a susceptibilidade de diferentes tubos gotejadores ao entupimento por ferro solúvel via duas qualidades de água de irrigação (com e sem carga orgânica) e na fase 2, avaliou-se a susceptibilidade de diferentes tubos gotejadores ao entupimento por aplicação de ferro solúvel, carga orgânica (fitoplâncton/algas) e sólidos em suspensão, com os emissores posicionados para cima e para baixo, ainda na fase 2 aplicou-se uma solução concentrada, nos tratamentos T1 e T4, com uma relação de 1:30, diretamente nos tubos gotejadores, sem passar por filtragem, este procedimento fora adotado com o objetivo de simular a quantidade de material sedimentado numa linha de tubos gotejadores instalada em campo, de aproximadamente 300 metros. No experimento B, foram realizados dois tratamentos (T5 e T6) onde se avaliou a susceptibilidade de diferentes tubos gotejadores em uso ao entupimento por ferro solúvel, carga orgânica (fitoplâncton/algas) e sólidos suspensos (partículas de solo). O delineamento experimental utilizado foi o inteiramente casualizado, com utilização dos testes F para análise de variância e Tuckey, a 5% de significância, para comparação de médias. Os resultados obtidos mostraram que a aplicação de sólidos em suspensão e elevado teor de ferro, sem passar por filtragem (tratamentos T1 e T4/Fase2/experimento A) intensificaram o processo de entupimento e que a adição de partículas de solo aos tratamentos, passando pelo sistema de filtragem (T2 e T3/Fase 2/experimento A), não potencializou mudanças significativas do cenário de suscetibilidade ao entupimento na grande maioria dos diferentes modelos de tubos gotejadores. O posicionamento para baixo dos orifícios dos emissores foi o que demonstrou maior suceptibilidade ao entupimento. Nos ensaios realizados no experimento A os modelos A, C e L foram os que apresentaram um melhor desempenho, mantendo suas vazões praticamente constante mesmo quando submetidos aos tratamentos mais agressivos (tratamentos T1 e T4/Fase2/experimento A). Os tratamentos realizados no experimento A mostraram que os modelos E, F, G e P foram os que sofreram maiores percentuais de obstrução. Os modelos E e F também apresentaram o pior desempenho quando submetidos aos ensaios realizados tratamento T5 (hidróxido de ferro + água LAB) do experimento B. / This research project was developed to quantify possible disturbances of flow rate in drip emitters subject to the application of soluble iron, suspended solids (soil particles) in water containing organic material (phytoplankton / algae), with emitters outlet positioned down and up. Two experiments were carried out A and B during 12 months period, using 16 models of new drip tubes and 26 models of used drip tubes. The tests were conducted on a bench test located at the Irrigation and Drainage Laboratory of the University of Sao Paulo (ESALQ / USP). Experiment A implemented 4 treatments (T1, T2, T3 and T4) in two phases: in phase 1 it was evaluated the susceptibility of different drip tube to clogging by soluble iron under two water qualities (with and without organic load) and in phase 2 it was assessed the susceptibility of different drip tube for clogging by the application of soluble iron, organic load (phytoplankton / algae) and suspended solids with emitters outlet positioned up and down, still in phase 2 it was applied a concentrated solution in T1 and T4, with a concentration relation 1:30, directly to drip tubes, without passing through the filter, this procedure was adopted to simulate the amount of material sedimented in a lateral line of drip tubes installed in the field, of approximately 300 meters. Experiment B carried out two treatments (T5 and T6) which evaluated the susceptibility of different used drip tube for clogging by soluble iron, organic load (phytoplankton / algae) and suspended solids (soil particles). The experimental design was completely randomized, with the test \"F\" for variance analysis and Tuckey test at 5% of significance to comparison of means. The results showed that applying suspended solids and high content of iron, without passing through the filtering system (T1 and T4/Fase 2/experiment A) intensified the clogging process and the addition of soil particles to treatments through the filtering system (T2 and T3/Fase 2/experiment A) presented no significant change in the scenario of the most different types of drip tubes tested. The positioning of emitters outlet down was more susceptible to clogging. The treatments performed in experiment A showed that the models A, C and L presented the better performance, maintaining their nearly constant flow rate even when subjected to more aggressive treatments (T1 and T4/Fase 2/experiment A). The treatments implemented in experiment A showed that the models E, F, G and P were those that suffered more obstruction. Models E and F also showed the worst performance when subjected to the tests T5 treatment (iron hydroxide + water LAB) of the experiment B.
4

Influência da adubação orgânica na qualidade da água destinada à irrigação de hortaliças

Célico, Amanda Schimidt [UNESP] 02 June 2015 (has links) (PDF)
Made available in DSpace on 2015-10-06T13:02:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-06-02. Added 1 bitstream(s) on 2015-10-06T13:19:20Z : No. of bitstreams: 1 000848521.pdf: 1031477 bytes, checksum: 9cafa3f6671b953378fe6c4f9820dae0 (MD5) / O composto orgânico proveniente do processo de compostagem de carcaças, resíduos animais e vegetais constitui-se em uma alternativa viável para a substituição total ou parcial dos fertilizantes minerais. Entretanto, pouco se conhece sobre o impacto ambiental do uso agrícola desse composto na qualidade da água. O objetivo com este trabalho foi avaliar a qualidade da água de um córrego que irriga uma área agrícola tratada com composto orgânico produzido pela compostagem de carcaças, resíduos animais e vegetais. A amostragem da água foi realizada bianualmente em 2013 e 2014 em seis pontos diferentes: um no local de captação de água para irrigação, dois à montante, dois à jusante desse ponto e um em poço não jorrante. As variáveis analisadas foram pH, temperatura, oxigênio dissolvido, condutividade, turbidez, potencial de oxidação-redução, sólidos totais dissolvidos, cloreto, nitrato, nitrito, nitrogênio amoniacal, fósforo total e reativo, demanda química de oxigênio, coliformes totais, E. coli e consumo de substratos (Ecoplate). Os resultados das análises comparados com padrões de qualidade de água estabelecidos em normas nacionais indicaram que o ambiente não estava impactado negativamente. Não se observou correlação entre uso do composto orgânico e alterações na população microbiana dos diferentes pontos por meio da técnica de consumo de substratos. Este estudo demonstrou que o uso desse tipo de composto não influenciou negativamente a qualidade da água. Portanto, esse adubo é uma alternativa viável para a produção agrícola local / Compost from carcasses, as well as animal and vegetable waste, constitutes a viable alternative for the partial or total substitution of mineral fertilizers. However, little is known about the environmental impact of using this agricultural compound on the quality of water. The aim was to evaluate the water quality of a stream that irrigates an agricultural area treated with organic compost produced by carcasses, animal and vegetable waste. We sampled water biannually in 2013 and 2014 from six different locations: one water catchment site for vegetable irrigation, two sites upstream, two downstream from that point and one water well. The variables analyzed were pH, temperature, dissolved oxygen, conductivity, turbidity, redox potential, dissolved solids, chemical oxygen demand, chloride, nitrate, nitrite, ammonia nitrogen, total and reactive phosphorus, total coliforms, E. coli and substrate consumption (Ecoplate). The analytical results compared with national water quality standards indicated that the environment was not negatively impacted by the compost. Using the substrate consumption technique, we observed that there was no correlation between the use of the organic compost and changes in microbial populations of the different points sampled. This study showed that the use of this organic compost does not negatively influence the quality of surface water in area studied. Therefore, the organic compost is a novel and attractive alternative for local agricultural production
5

Dinâmica do entumpimento de tubos gotejadores sob aplicação de ferro solúvel, sólidos em suspensão e fitoplâncton / Clogging dynamics of driplines under the application of soluble iron, suspended solids and fitoplankton

Lilian Cristina Castro de Carvalho 01 October 2009 (has links)
Este projeto de pesquisa foi desenvolvido visando quantificar possíveis distúrbios de vazão em emissores gotejadores submetidos à aplicação de ferro solúvel, sólidos em suspensão (partículas de solo) em águas contendo material orgânico (fitoplâncton/algas), com o orifício dos emissores posicionados para baixo e para cima. Foram realizados dois experimentos A e B em um período de 12 meses, utilizando-se 16 modelos de tubos gotejadores novos e 26 modelos de tubos gotejadores em uso, com suas respectivas linhas gotejadoras montadas em uma bancada de ensaios em estrutura metálica localizada no Laboratório de Irrigação, da Escola Superior de Agricultura Luiz de Queiroz - ESALQ/USP. No experimento A realizou-se 4 tratamentos (T1, T2, T3 e T4), divididos em duas fases, onde na fase 1 avaliou-se a susceptibilidade de diferentes tubos gotejadores ao entupimento por ferro solúvel via duas qualidades de água de irrigação (com e sem carga orgânica) e na fase 2, avaliou-se a susceptibilidade de diferentes tubos gotejadores ao entupimento por aplicação de ferro solúvel, carga orgânica (fitoplâncton/algas) e sólidos em suspensão, com os emissores posicionados para cima e para baixo, ainda na fase 2 aplicou-se uma solução concentrada, nos tratamentos T1 e T4, com uma relação de 1:30, diretamente nos tubos gotejadores, sem passar por filtragem, este procedimento fora adotado com o objetivo de simular a quantidade de material sedimentado numa linha de tubos gotejadores instalada em campo, de aproximadamente 300 metros. No experimento B, foram realizados dois tratamentos (T5 e T6) onde se avaliou a susceptibilidade de diferentes tubos gotejadores em uso ao entupimento por ferro solúvel, carga orgânica (fitoplâncton/algas) e sólidos suspensos (partículas de solo). O delineamento experimental utilizado foi o inteiramente casualizado, com utilização dos testes F para análise de variância e Tuckey, a 5% de significância, para comparação de médias. Os resultados obtidos mostraram que a aplicação de sólidos em suspensão e elevado teor de ferro, sem passar por filtragem (tratamentos T1 e T4/Fase2/experimento A) intensificaram o processo de entupimento e que a adição de partículas de solo aos tratamentos, passando pelo sistema de filtragem (T2 e T3/Fase 2/experimento A), não potencializou mudanças significativas do cenário de suscetibilidade ao entupimento na grande maioria dos diferentes modelos de tubos gotejadores. O posicionamento para baixo dos orifícios dos emissores foi o que demonstrou maior suceptibilidade ao entupimento. Nos ensaios realizados no experimento A os modelos A, C e L foram os que apresentaram um melhor desempenho, mantendo suas vazões praticamente constante mesmo quando submetidos aos tratamentos mais agressivos (tratamentos T1 e T4/Fase2/experimento A). Os tratamentos realizados no experimento A mostraram que os modelos E, F, G e P foram os que sofreram maiores percentuais de obstrução. Os modelos E e F também apresentaram o pior desempenho quando submetidos aos ensaios realizados tratamento T5 (hidróxido de ferro + água LAB) do experimento B. / This research project was developed to quantify possible disturbances of flow rate in drip emitters subject to the application of soluble iron, suspended solids (soil particles) in water containing organic material (phytoplankton / algae), with emitters outlet positioned down and up. Two experiments were carried out A and B during 12 months period, using 16 models of new drip tubes and 26 models of used drip tubes. The tests were conducted on a bench test located at the Irrigation and Drainage Laboratory of the University of Sao Paulo (ESALQ / USP). Experiment A implemented 4 treatments (T1, T2, T3 and T4) in two phases: in phase 1 it was evaluated the susceptibility of different drip tube to clogging by soluble iron under two water qualities (with and without organic load) and in phase 2 it was assessed the susceptibility of different drip tube for clogging by the application of soluble iron, organic load (phytoplankton / algae) and suspended solids with emitters outlet positioned up and down, still in phase 2 it was applied a concentrated solution in T1 and T4, with a concentration relation 1:30, directly to drip tubes, without passing through the filter, this procedure was adopted to simulate the amount of material sedimented in a lateral line of drip tubes installed in the field, of approximately 300 meters. Experiment B carried out two treatments (T5 and T6) which evaluated the susceptibility of different used drip tube for clogging by soluble iron, organic load (phytoplankton / algae) and suspended solids (soil particles). The experimental design was completely randomized, with the test \"F\" for variance analysis and Tuckey test at 5% of significance to comparison of means. The results showed that applying suspended solids and high content of iron, without passing through the filtering system (T1 and T4/Fase 2/experiment A) intensified the clogging process and the addition of soil particles to treatments through the filtering system (T2 and T3/Fase 2/experiment A) presented no significant change in the scenario of the most different types of drip tubes tested. The positioning of emitters outlet down was more susceptible to clogging. The treatments performed in experiment A showed that the models A, C and L presented the better performance, maintaining their nearly constant flow rate even when subjected to more aggressive treatments (T1 and T4/Fase 2/experiment A). The treatments implemented in experiment A showed that the models E, F, G and P were those that suffered more obstruction. Models E and F also showed the worst performance when subjected to the tests T5 treatment (iron hydroxide + water LAB) of the experiment B.
6

Influência da adubação orgânica na qualidade da água destinada à irrigação de hortaliças /

Célico, Amanda Schimidt. January 2015 (has links)
Orientador: Lúcia Maria Carareto Alves / Coorientador: Luciana Maria Saran / Banca: Analu Egydio dos Santos / Banca: José Renato Zanini / Resumo: O composto orgânico proveniente do processo de compostagem de carcaças, resíduos animais e vegetais constitui-se em uma alternativa viável para a substituição total ou parcial dos fertilizantes minerais. Entretanto, pouco se conhece sobre o impacto ambiental do uso agrícola desse composto na qualidade da água. O objetivo com este trabalho foi avaliar a qualidade da água de um córrego que irriga uma área agrícola tratada com composto orgânico produzido pela compostagem de carcaças, resíduos animais e vegetais. A amostragem da água foi realizada bianualmente em 2013 e 2014 em seis pontos diferentes: um no local de captação de água para irrigação, dois à montante, dois à jusante desse ponto e um em poço não jorrante. As variáveis analisadas foram pH, temperatura, oxigênio dissolvido, condutividade, turbidez, potencial de oxidação-redução, sólidos totais dissolvidos, cloreto, nitrato, nitrito, nitrogênio amoniacal, fósforo total e reativo, demanda química de oxigênio, coliformes totais, E. coli e consumo de substratos (Ecoplate). Os resultados das análises comparados com padrões de qualidade de água estabelecidos em normas nacionais indicaram que o ambiente não estava impactado negativamente. Não se observou correlação entre uso do composto orgânico e alterações na população microbiana dos diferentes pontos por meio da técnica de consumo de substratos. Este estudo demonstrou que o uso desse tipo de composto não influenciou negativamente a qualidade da água. Portanto, esse adubo é uma alternativa viável para a produção agrícola local / Abstract: Compost from carcasses, as well as animal and vegetable waste, constitutes a viable alternative for the partial or total substitution of mineral fertilizers. However, little is known about the environmental impact of using this agricultural compound on the quality of water. The aim was to evaluate the water quality of a stream that irrigates an agricultural area treated with organic compost produced by carcasses, animal and vegetable waste. We sampled water biannually in 2013 and 2014 from six different locations: one water catchment site for vegetable irrigation, two sites upstream, two downstream from that point and one water well. The variables analyzed were pH, temperature, dissolved oxygen, conductivity, turbidity, redox potential, dissolved solids, chemical oxygen demand, chloride, nitrate, nitrite, ammonia nitrogen, total and reactive phosphorus, total coliforms, E. coli and substrate consumption (Ecoplate). The analytical results compared with national water quality standards indicated that the environment was not negatively impacted by the compost. Using the substrate consumption technique, we observed that there was no correlation between the use of the organic compost and changes in microbial populations of the different points sampled. This study showed that the use of this organic compost does not negatively influence the quality of surface water in area studied. Therefore, the organic compost is a novel and attractive alternative for local agricultural production / Mestre
7

Dinâmica de entupimento de gotejadores em função da aplicação de água rica em ferro /

Brauer, Rigléia Lima, 1980- January 2010 (has links)
Orientador: Raimundo Leite Cruz / Coorientador: Roberto Lyra Villas Bôas / Banca: Dirceu Maximino Fernandes / Banca: João Luis Zocoler / Helton Rogério Mazzer / Resumo: Com o propósito de avaliar a susceptibilidade de dois tipos de gotejadores ao processo de entupimento por ferro, foi conduzido um experimento em uma bancada de ensaios no Laboratório de Ensaio de Equipamentos para Irrigação do Departamento de Engenharia Rural da Universidade Estadual Paulista "Júlio de Mesquita Filho" - Campus de Botucatu. O ensaio corresponde ao processo de entupimento, e foram avaliados os seguintes modelos de gotejadores NaanDanJain: NaanPC laranja e NaanPC azul. Foram utilizados segmentos de tubos, totalizando 25 emissores, onde se mediu a vazão com a pressão de 150 KPa, com três repetições para cada gotejador. A água utilizada no ensaio foi proveniente do lago do Departamento de Engenharia Rural que é comumente utilizado para irrigações de experimentos. Posteriormente foram calculados: Vazão Média, Coeficiente de Variação de Vazão (C.V.Q), Uniformidade de Distribuição da Água (C.U.D), Coeficiente de Uniformidade de Christiansen (C.U.C) e Vazão Relativa (V.R.). Foi utilizado delineamento experimental estatístico de blocos inteiramente casualizados, com fatorial 2x2x7, com três repetições, sendo o primeiro fator os tratamentos com ferro, o segundo fator os tipos de gotejadores e o terceiro fator o tempo. Os resultados obtidos não apontaram diferença significativa nas diferentes doses de ferro. Entretanto, os resultados apontaram diferença significativa na interação gotejador x tempo e coeficiente de uniformidade de Christiansen (CUC) e vazão relativa (V.R.) / Abstract: The objective of this study was to evaluate the susceptibility of clogging by iron in two types of drippers using a test bank located at the Irrigation Experimental Laboratory in the Department of Agricultural Engineering of "Sao Paulo State University Julio de Mesquita Filho "- Campus of Botucatu, Sao Paulo state. The experiment aims to study the clogging process, evaluating 2 models of drippers NaanDanJain: NaanPC orange and NaanPC blue. It was used tube segments, totaling 25 drippers, using pressure of 150 kPa, with 3 repetitions for each dripper. The water used in the test was from the lake of the Department of Agricultural Engineering which is commonly used for irrigation experiments. It was calculated: the average discharge, the variation coefficient of discharge (CVQ), the uniformity coefficient of distribution (CUD), the uniformity coefficient of Christiansen (CUC) and the relative discharge (VR). It was used statistical experimental design of randomized blocks, with a 2x2x7 factorial with three replications, with the first factor treatment with iron, the second factor the types of drippers and the third factor the time. The results showed no significant difference in different doses of iron. However, the results indicated significant differences in drip x time interaction and the Christiansen uniformity coefficient (CUC) and relative discharge rate (VR) / Mestre
8

Perda de carga em filtros de tela e de discos utilizados na irrigação localizada / Loading losses in net and disc filters used in dropping irrigation

Oliveira, Cleomar Ferreira de 23 January 2006 (has links)
Os sistemas de irrigação localizada requerem, obrigatoriamente sistemas de filtração para um tratamento mínimo da água. Os filtros são fundamentais à qualidade da água utilizada na agricultura irrigada, promovendo melhor desempenho dos sistemas de irrigação e seus componentes. Neste trabalho, estudou-se a perda de carga em função da vazão, em filtros de tela e de discos e determinou-se a bateria de filtros de mínimo custo anual total para diferentes vazões de projeto. Os ensaios foram realizados no laboratório de irrigação do Departamento de Engenharia Rural da Escola Superior de Agricultura "Luiz de Queiroz", Universidade de São Paulo, utilizando-se filtros comerciais da marca AMIAD, com elemento filtrantes de tela (modelos 3/4", 1", 1 ½" e 2") de discos (modelos 1", 1 ½" e 2"). A vazão máxima utilizada no ensaio, para cada modelo de filtro, foi àquela recomendada pelo fabricante. Para todos os filtros analisados no laboratório observaram-se altos valores dos coeficientes de determinação (R2) indicando uma forte relação potencial entre as variáveis vazão e perda de carga. Considerando as condições em que o estudo foi realizado e com base nos resultados obtidos, conclui-se que: o modelo matemático potencial descreve adequadamente a variação da perda de carga nos filtros de tela e discos em função da variação da vazão; os filtros de tela proporcionam menor perda de carga que os filtros de discos; a filtragem da água utilizando filtros de discos apresenta maior custo anual total; para os limites de vazão estudados e para as perdas de carga máximas permitidas, em geral as baterias compostas por filtros de 2" apresentaram o menor custo mínimo anual total; de forma geral, para os filtros estudados, as curvas de perda de carga em função da vazão apresentadas no catálogo do fabricante não representaram fielmente as curvas obtidas nesse trabalho, em ensaio de laboratório. / Drip irrigation systems always require filtration systems for a basic water treatment. The filters are fundamental for the water quality used in irrigated farming, providing better performance of irrigation systems and their components. It was studied in this work the loading loss according to the flow in net and disc filters and it was determined the filter sets with the minimum cost for different flows. The trials were carried out in the irrigation laboratory of the Rural Engineering Department of the Superior School of Agriculture "Luiz de Queiroz", São Paulo University, using AMIAD brand commercial filters, with net filtration elements (models 3/4", 1", 1 ½" ", and 2"), and discs (models 1", 1 ½" and 2").The maximum flow used in the trial, for each filter model, was that recommended by the manufacturer. It was observed for all the analyzed filters in the laboratory high values of determination coefficient (R2) indicating a strong potential relation between the flow and loading loss variables. Considering the conditions in which the study was carried out and based on the results obtained, it was concluded that: The potential mathematical model describes adequately the loading loss variation in the net and disc filters according to the flow variation; the net filters provide less loading loss than the disc filters; the water filtration using disc filters show higher total annual cost; for the studied flow limits and for the maximum allowed loading loss, in general the sets composed of 2" filters present the lowest total annual cost, overall, for the filters studied, the loading loss curves according to the flow showed in the manufacturer’s catalogue did not present accurately the curves obtained on this work in laboratory trial.
9

Construção e avaliação de hidrociclone para pré-filtragem da água de irrigação. / Construction and evaluation of hydrocyclone for pre-filtering irrigation water.

Soccol, Olivio José 28 February 2003 (has links)
Na agricultura irrigada, a qualidade da água utilizada é de fundamental importância para o perfeito funcionamento dos sistemas de irrigação e de seus componentes. A utilização de água contendo sedimentos em suspensão tem sido a causa de sérios problemas em sistemas de irrigação, reduzindo a vida útil de seus componentes, promovendo o entupimento de tubulações e emissores, ocasionando como conseqüência, irrigações não uniformes e queda na eficiência dos mesmos. A escolha do tipo e capacidade do sistema de filtragem é de fundamental importância, evitando-se assim, aumento nos custos de operação e manutenção do sistema de irrigação, devido a necessidade de limpeza e trocas freqüentes de seus componentes. Pré-filtros, como os hidrociclones, desempenham importante papel, pois se caracterizam por significativo poder de separação de partículas, maiores do que 100 mm, presentes na água; mantendo constante a perda de carga ao longo do tempo, o que não ocorre com os outros tipos de filtros normalmente utilizados nos sistemas de irrigação. Apesar de algumas referências feitas aos hidrociclones em literatura internacional, não se dispõe, no Brasil, de dados do desempenho dos hidrociclones, quando empregados em pré-filtragem da água utilizada nos sistemas de irrigação. Assim, um experimento conduzido no Laboratório de Hidráulica do Departamento de Engenharia Rural da ESALQ/USP, compreendeu a construção de quatro hidrociclones do tipo Rietema, com diâmetro de 50 mm, um com bocal de alimentação circular e os demais com bocais de seção retangular, cujas seções foram decrescentes. A avaliação do desempenho dos mesmos foi realizada utilizando-se suspensões de areia fina e solo argiloso, sob diferentes diferenciais de pressão, adotando-se como critério de comparação, a capacidade de vazão e o poder de separação, medido pela eficiência total e eficiência total reduzida. Os resultados obtidos mostraram que o hidrociclone dotado com bocal de alimentação circular apresentou os maiores índices nos critérios de comparação, tanto para a suspensão de areia, quanto para a de solo. / Good water quality is uppermost in irrigated agriculture for the perfect functioning of irrigation systems and their components. The use of water containing suspended sediments has caused serious problems to irrigation systems, reducing the useful life of their components, clogging pipes and emitters, consequently causing non-uniform irrigations and low efficiency. Choosing the right filtering system type and capacity is essential to avoid increases in operational and maintenance costs of irrigation systems due to the need for cleaning and frequent replacing of their components. Pre-filters, such as hydrocyclones, are important for their significant capability to retain particles larger than 100 mm present in water, keeping the head loss constant with the time, unlike other filters normally used in irrigation systems. Despite being present in the international literature, data on the performance of hydrocyclones used for pre-filtering irrigation water in Brazil are not available. Therefore, four Rietema type hydrocyclones (50 mm diameter) were construction in the Hydraulics Laboratory of the Rural Engineering Department - ESALQ/USP- one presenting circular-end feeding tube and the other three presenting rectangular-end feeding tubes with decreasing sections. The evaluation of the hydrocyclones performance was conducted by using suspensions of fine sand and clay soil under various pressure differentials. The comparison criteria used were the discharge and the separation capability, given by total efficiency and reduced total efficiency. Results showed that the hydrocyclone with circular-end feeding tube presented the highest indexes for the comparison criteria adopted, considering sand and soil suspensions.
10

Construção e avaliação de hidrociclone para pré-filtragem da água de irrigação. / Construction and evaluation of hydrocyclone for pre-filtering irrigation water.

Olivio José Soccol 28 February 2003 (has links)
Na agricultura irrigada, a qualidade da água utilizada é de fundamental importância para o perfeito funcionamento dos sistemas de irrigação e de seus componentes. A utilização de água contendo sedimentos em suspensão tem sido a causa de sérios problemas em sistemas de irrigação, reduzindo a vida útil de seus componentes, promovendo o entupimento de tubulações e emissores, ocasionando como conseqüência, irrigações não uniformes e queda na eficiência dos mesmos. A escolha do tipo e capacidade do sistema de filtragem é de fundamental importância, evitando-se assim, aumento nos custos de operação e manutenção do sistema de irrigação, devido a necessidade de limpeza e trocas freqüentes de seus componentes. Pré-filtros, como os hidrociclones, desempenham importante papel, pois se caracterizam por significativo poder de separação de partículas, maiores do que 100 mm, presentes na água; mantendo constante a perda de carga ao longo do tempo, o que não ocorre com os outros tipos de filtros normalmente utilizados nos sistemas de irrigação. Apesar de algumas referências feitas aos hidrociclones em literatura internacional, não se dispõe, no Brasil, de dados do desempenho dos hidrociclones, quando empregados em pré-filtragem da água utilizada nos sistemas de irrigação. Assim, um experimento conduzido no Laboratório de Hidráulica do Departamento de Engenharia Rural da ESALQ/USP, compreendeu a construção de quatro hidrociclones do tipo Rietema, com diâmetro de 50 mm, um com bocal de alimentação circular e os demais com bocais de seção retangular, cujas seções foram decrescentes. A avaliação do desempenho dos mesmos foi realizada utilizando-se suspensões de areia fina e solo argiloso, sob diferentes diferenciais de pressão, adotando-se como critério de comparação, a capacidade de vazão e o poder de separação, medido pela eficiência total e eficiência total reduzida. Os resultados obtidos mostraram que o hidrociclone dotado com bocal de alimentação circular apresentou os maiores índices nos critérios de comparação, tanto para a suspensão de areia, quanto para a de solo. / Good water quality is uppermost in irrigated agriculture for the perfect functioning of irrigation systems and their components. The use of water containing suspended sediments has caused serious problems to irrigation systems, reducing the useful life of their components, clogging pipes and emitters, consequently causing non-uniform irrigations and low efficiency. Choosing the right filtering system type and capacity is essential to avoid increases in operational and maintenance costs of irrigation systems due to the need for cleaning and frequent replacing of their components. Pre-filters, such as hydrocyclones, are important for their significant capability to retain particles larger than 100 mm present in water, keeping the head loss constant with the time, unlike other filters normally used in irrigation systems. Despite being present in the international literature, data on the performance of hydrocyclones used for pre-filtering irrigation water in Brazil are not available. Therefore, four Rietema type hydrocyclones (50 mm diameter) were construction in the Hydraulics Laboratory of the Rural Engineering Department – ESALQ/USP- one presenting circular-end feeding tube and the other three presenting rectangular-end feeding tubes with decreasing sections. The evaluation of the hydrocyclones performance was conducted by using suspensions of fine sand and clay soil under various pressure differentials. The comparison criteria used were the discharge and the separation capability, given by total efficiency and reduced total efficiency. Results showed that the hydrocyclone with circular-end feeding tube presented the highest indexes for the comparison criteria adopted, considering sand and soil suspensions.

Page generated in 0.1012 seconds