• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Μελέτη αντικεραυνικής συμπεριφοράς γραμμών διανομής Αιγίου-Καλαβρύτων

Ταμβάκος, Δημήτρης 25 May 2010 (has links)
Σε αυτή την διπλωματική εργασία θα γίνει μελέτη της συμπεριφοράς γραμμών διανομής σε καταπονήσεις από κεραυνούς. Οι κεραυνοί αποτελούν ένα φυσικό φαινόμενο με επικίνδυνα αποτελέσματα για την ασφάλεια των ανθρώπων, των κτιρίων και των ηλεκτρικών συστημάτων. Έτσι, κεραυνοί που πλήττουν άμεσα γραμμές διανομής ή γειτονικό σε αυτές έδαφος, είναι υπεύθυνοι για τα σφάλματα που λαμβάνουμε στο ηλεκτρικό σύστημα. Το αποτέλεσμα της πτώσης κεραυνού μπορεί να οδηγήσει σε στιγμιαίο ή μόνιμο σφάλμα. Στιγμιαίο λέγεται αν αυτό “καθαριστεί” από τις διατάξεις προστασίας και το κύκλωμα να ξαναμπεί σε λειτουργία, ενώ το μόνιμο απαιτεί την εξωτερική παρέμβαση από τεχνικούς για την επαναλειτουργία του κυκλώματος. Οι προβλέψεις για την συμπεριφορά των εναερίων γραμμών διανομής εμπεριέχουν πολλές αβεβαιότητες. Mερικές βασικές παράμετροι όπως η πυκνότητα των κεραυνών, που μετριέται με την πυκνότητα των κεραυνών στο έδαφος (GFD), ή ο υπολογισμός του αριθμού των απευθείας πληγμάτων στην γραμμή απέχουν από την πραγματικότητα. Μελετώντας την εργασία αυτή μπορούμε να δώσουμε ακριβείς προβέψεις σφαλμάτων λόγω κεραυνών σε μια γραμμή διανομής. Στο πρώτο μέρος της εργασίας αναφέρεται η οδηγία της ΙΕΕΕ για τη συμπεριφορά των εναέριων γραμμών διανομής ηλεκτρικής ενέργειας έναντι κεραυνών. Σκοπός της είναι να παρουσιάσει εναλλακτικές λύσεις για τη μείωση των βραχυκυκλωμάτων που προκαλούνται από κεραυνό στις εναέριες γραμμές. Συγκεκριμένα θα προσδιοριστεί η συμπεριφορά των εναέριων γραμμών διανομής σε περίπτωση πτώσης κεραυνού (πλήγματα κεραυνών και βραχυκυκλώματα από επαγόμενη τάση), το επίπεδο μόνωσης των γραμμών διανομής, η προστασία των γραμμών διανομής με προστατευτικό αγωγό καθώς επίσης και η προστασία των γραμμών με αλεξικέραυνα. Στο δεύτερο μέρος της εργασίας, θα αναπτυχθεί η καταγραφή σφαλμάτων και βλαβών λόγω πτώσεως κεραυνών στο δίκτυο της Μ.Τ. σε μετασχηματιστές καθώς και στις γραμμές διανομής Μ.Τ. τα τελευταία πέντε χρόνια (2003 – 2008) στην περιοχή της Αχαίας. Επίσης υπολογίζεται αναλυτικά ο αριθμός των θεωριτικών σφαλμάτων που προκείπτουν σύμφωνα με την παραπάνω οδηγία και γίνεται η συσχέτισή τους με τα πραγματικά αποτελέσματα. Τέλος ακολουθούν κάποια ραβδογράμματα για καλύτρερη κατανόηση των αποτελεσμάτων. / This diploma thesis studies the lightning performance of electric power overhead distribution lines. Lightning is a physical phenomenon which usually has dangerous consequences on people or buildings, and it is also the major cause of faults on typical overhead distribution lines. So a lightning that strikes directly to a distribution line, or to the nearby area is responsible for the damage happening to the electric circuit. Lightning usually causes temporary faults on overhead distribution lines. If the fault is cleared by a breaker or a recloser, the circuit may be successfully reclosed. But it can also cause permanent faults by damaging the equipment, which needs external help in order to restore the damage. Estimates of the lightning performance of distribution lines contain many uncertainties. Some of the basics such as lightning intensity measured by ground flash density (GFD), or estimating the number of direct strikes to a distribution line may have significant errors. Often, rough estimates or generally accepted practices are just as effective as detailed calculations. This guide is intended to provide straightforward estimates of lightning-caused faults. To the first part of this project we can find the “IEEE Guide for Improving the Lightning Performance of Electric Power Overhead Distribution Lines” it’s goal is to present alternative solutions for the reduction of the flashovers caused by the lightning strike on overhead distribution lines. Specifically we deal with the lightning performance of the overhead distribution lines during a lightning case (direct strike or induced flashover), the insulation level of distribution lines, the protection of the distribution lines with a shield wire or with arresters. To the second part of this diploma thesis we can find real fault situations that have happened to the middle voltage distribution circuit to the region of Aegio GREECE the last five years (2003-2008). Moreover there is a detailed way of providing the theoretical number of faults according to this guide, after that follows a comparison between experimental and real values as well as some charts for better understanding of the results.
2

Μέτρηση του ρεύματος διαρροής σε θάλαμο με τεχνητούς ρύπους

Καραντάκος, Αστέριος 07 June 2010 (has links)
- / In the present diplomatic project is realised a process of measurements of the leakage current by the system of measurement that was manufactured by gentleman Sideraki, in the frames of his doctoral thesis. The measurements were realised in the substation 150 kV of Crete‟s system of transport and in the substation 150 kV of A.I.S. Linoperamaton. In the first chapter, is presented the phenomenon of the insulators‟ pollution, while it constitutes the prime cause of the leakage current. Here are presented the main causes of pollution, its unfavourable results as well as her ways of confrontation. There is an extensive report, in the use of multilateral insulators and multilateral coatings for the confrontation of the phenomenon of pollution. Particularly is stressed the hydrophobic characteristic of these materials which leads to the reduction of the quantity of pollution on the surface of the insulators. The second chapter, is a presentation of the work of various researchers over the world, in the effort of studying the leakage current and its connection with the phenomena of ageing and flashover. Also there are mentioned the experimental provisions that they used in the frames of their studies and are reported the mainer conclusions to which they were led. Common point of their conclusions constitutes the make of ascertainment that the biggest price of the leakage current, constitutes an unreliable indicator of description of the distressed insulator‟s surface, since important information on the situation of the surface we draw also from the waveform of the leakage current. In the third chapter there is a concise presentation of Fourier„s theory and transforming, while an extensive report in the distinguishable Fourier transforming (DFT) is also mentioned. Finally, is presented the fast Fourier transforming (FFT), which constitutes an algorithm of fast calculation of distinguishable transformation Fourier and is used among others for the spectrum analysis of signals of distinguishable time. In the fourth chapter, is realised the treatment of measurements, with the use of Labview for the study of the leakage current in the field of frequency. Leakage current‟s waveforms are categorized, with criteria, the lack of linearity and the presence of discharges or not and conclusions are exported on these waveforms, from their spectrum analysis.

Page generated in 0.0412 seconds