• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

X-ray spectra optimization using lanthanide and non elements for bone quality assessment with Dual Energy method / Οστική πυκνομετρία διπλής ενέργειας : Ανάπτυξη αλγορίθμου για την επιλογή κατάλληλου φάσματος από λυχνία ακτίνων-Χ με χρήση ειδικών φίλτρων (σπανίων γαιών κ.ά.)

Μαρτίνη, Νίκη 11 October 2013 (has links)
Osteoporosis is a disease of the bones. It is often called the “silent disease," because someone could have it now or be at-risk without even realizing it. As a result, bones become weak and can break from a minor fall or, in serious cases, even from simple actions, like sneezing or bumping into furniture. Breaking a bone is often the first clue that someone suffers from osteoporosis. The diagnosis of osteoporosis can be made using conventional radiography and by measuring the Bone Mineral Density (BMD). The most popular method of measuring BMD is Dual-Energy X-ray Absorptiometry (DXA). In conventional methods the measurement of bone does not give information about the bone quality but for the bone quantity. A non-invasive method that will have the ability to determine the bone quality is of interest. Such a method will contribute to the prediction or even the prevention of bone malfunction. In this study, two quality parameters, that are designed to contribute to improved diagnostic methods of osteoporosis, are determined. Those bone quality parameters are the Calcium/Phosphate (Ca/P) and Hydroxyapatite/Collagen (HAp/Col) ratios. The algorithm developed allows us to trace the spectral changes which take place when an x-ray beam passes through filters based on the Lambert and Beer’s law. A large number of filters were applied to spectra so as to obtain pseudo-monoenergetic spectra. The optimum energy pair would derive from two quasi-monoenergetic spectra with sufficient number of photons which will result in the minimization of the Coefficient of Variation (CV) of the aforementioned ratios. Dual Energy x-ray method is used in order to obtain this energy pair. Both Single and Double exposure techniques are used. / Η οστεοπόρωση είναι μια ασθένεια των οστών. Συχνά αποκαλείται ως η «αθόρυβη ασθένεια», καθώς κάποιος δεν αντιλαμβάνεται ότι νοσεί από αυτή. Σαν αποτέλεσμα της ασθένειας αυτής, τα οστά αδυνατίζουν και μπορεί να σπάσουν ακόμα και με ένα πολύ μικρό πέσιμο, ή ακόμα στις πιο σοβαρές περιπτώσεις, ακόμα και με ένα φτέρνισμα ή ένα χτύπημα στα έπιπλα. Η θραύση ενός οστού είναι το πρώτο σύμπτωμα της εμφάνισης της οστεοπόρωσης. Η διάγνωση της οστεοπόρωσης μπορεί να γίνει με τη συμβατική ακτινογραφία και μετρώντας την πυκνότητα των οστικών αλάτων (BMD). Η πιο διαδεδομένη μέθοδος μέτρησης του BMD είναι η DXA. Στην παρούσα μελέτη, υπολογίστηκαν δύο ποιοτικοί παράμετροι , ο λόγος ασβεστίου-φωσφόρου (Ca/P) και ο λόγος υδροξυαπατίτη- κολλαγόνου (HAp/Col). Πραγματοποιήθηκε αλγόριθμος στον οποίο έγινε χρήση διαφόρων φίλτρων έτσι ώστε να τροποποιηθούν τα φάσματα ακτίνων-Χ και να αποκτηθούν σχεδόν μονοενεργειακά φάσματα. Επιπλέον χρησιμοποιήθηκαν οι τεχνικές μονής και η διπλής έκθεσης.

Page generated in 0.0353 seconds