• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Προσομοίωση καταπτώσεων βράχων με υπολογιστικές μεθόδους: Εφαρμογή στην περιοχή του όρους Κλόκοβα της Ε. Ο. Αντιρρίου-Ιωαννίνων / Estimation of accident potential by rockfalls with computing programs: Applied at the Antirrion-Ioannina highway (Site of Klokova), Western Greece

Βλαχάκη, Ελένη 11 July 2013 (has links)
Το βασικό αντικείμενο της έρευνας είναι η διερεύνηση των τεχνικογεωλογικών και γεωτεχνικών συνθηκών των ανάντη υψηλών πρανών της Ε.Ο. Αντιρρίου – Ιωαννίνων από Χ.Θ. 7+500 έως Χ.Θ. 10+500 στην περιοχή της Κλόκοβας. Η μελέτη επικεντρώνεται σε δύο βασικούς άξονες: (α) στην επιτόπου διερεύνηση των συνθηκών που επικρατούν στην περιοχή, όπου και καταγράφηκαν όλες οι τεχνικογεωλογικές παράμετροι (γεωλογικά όρια, ρήγματα, μεγαλοασυνέχειες, χαρακτηριστικά ασυνεχειών, ταξινομήσεις βραχομάζας, καταγραφή καταπτώσεων, συλλογή δειγμάτων, εκτέλεση εργαστηριακών δοκιμών Βραχομηχανικής κ.α.). Αποτέλεσμα αυτών ήταν η σύνταξη τεχνικογεωλογικού χάρτη σε κλίμακα 1:1,000 και υποδιαίρεση της όλης περιοχής των πρανών της οδού σε δώδεκα (12) συνεχόμενες θέσεις μήκους από 100 – 380 μέτρα με βάση κυρίως την φυσική κατάσταση της βραχόμαζας (κερματισμός, αποσάθρωση), αλλά και άλλες επιμέρους παραμέτρους όπως γεωμετρία του πρανούς, επικινδυνότητα καταπτώσεων κ.α. (β) στην προσομοίωση καταπτώσεων βράχων σε χαρακτηριστικές διατομές των δώδεκα επιμέρους θέσεων με τη χρήση του λογισμικού ROCFALL και την εκτίμηση της αναμενόμενης ανά περίπτωση δυναμικής ενέργειας καταπτώσεων στο οδόστρωμα αλλά και του ύψους αναπήδησης των βραχωδών τεμαχών. Επιπρόσθετα, σε επιλεγμένες θέσεις υψηλών πρανών έγιναν προσεγγίσεις ευστάθειας πρανών με αναλύσεις παραμόρφωσης και μεθόδους πεπερασμένων στοιχείων, με τη χρήση του λογισμικού Phase2. Από τη συγκριτική θεώρηση των αποτελεσμάτων των μοντέλων καταπτώσεων και ευστάθειας είναι εφικτός ο ακριβής εντοπισμός θέσεων με αυξημένο κίνδυνο καταπτώσεων βράχων για όλο το μήκος της οδού και συνεπώς η χωροθέτηση των μέτρων προστασίας (κυρίως φράκτες αναχαίτισης) με τα βασικά χαρακτηριστικά τους. / The Basic object of this particular research is the investigation of geological and geotechnical conditions of the upper slopes at the Antirrio - Ioannina highway, from 7 + 500 km to 10 + 500 km, at the area of the mountain Klokova. The research focuses on two main axes: (a) the “in situ” investigation of the prevailing conditions, where the geotechnical parameters were recorded (geological boundaries, faults, macro-discontinuities, the features of discontinuity sets, rockmass characterization, rockfalls recording, rock samples collection, laboratory testing, etc.). As a result was the geotechnical mapping in scale 1: 1,000 and the subdivision of the entire researching area in twelve (12) consecutive zones, from 100 to 380 meters length, mainly based on physical rockmass condition (fragmented region, erosion), and other secondary parameters such as slopes’ geometry and hazard estimation. (b) the simulation of rockfalls at the twelve zones with the “Rocfall” software and the dynamic energy and bounce height estimation of rockfalls near the highway. Additionally, the slope stability approach performed at selected locations with the deformation analysis and finite element methods, using the program “Phase 2” Finally, comparing the results of these two models, the one about rockfall hazard and the second about slope stability, the precise identification of the locations with increased risk of rockfalls is possible for the entire length of the road and as a result the locations requiring protective measures (mainly interceptor fences) can be specified
2

Study of the computed tomography laser mammography (CTLM) interactions / Μελέτη των αλληλεπιδράσεων της μαστογραφίας laser με μεθόδους υπολογιστικής τομογραφίας

Καραγιώργου, Γεωργία 15 January 2009 (has links)
Breast cancer is the prime factor of women mortality in the developed countries. During the recent years however, many techniques in breast imaging have been developed and applied, with X-ray mammography been perhaps the most widely used of cancer diagnostic tests. Nevertheless, X-ray mammography although still remains the frontline diagnostic technique in the fight against breast cancer and has been a contributing factor in the steady decline in deaths from breast cancer, it has certain drawbacks which range from false-positive results to missed lesions and the risk of carcinogenesis. Mammography, whether conventional or digital, has been thoroughly documented as missing between 25% and 40% of breast cancers, with a higher miss rate among women with dense breasts, which constitute 40% of the female population. Because the mammogram is a projected image of superimposed breast structures, it is generally more difficult to detect cancer in a breast with a dense (i.e. lighter in appearance on a mammogram) pattern. As a result, mammography appears low sensitivity (ranging from 24.5% to 37%), especially in women with dense breasts. This is due to the fact that it only images anatomic detail and provides no functional information which is essential for early and accurate diagnosis of breast cancer and can be expected to significantly reduce the number of unnecessary biopsies. The special properties of light could help optical imaging "see" what other diagnostic methods, including conventional x-ray mammography, may miss. One of the newest techniques on the scene is CT laser mammography (CTLM), a computed tomographic laser light-based scanner for the breast, which is able to detect greater blood flow that is a sign of cancer, with a radiation free energy source. The Computed Tomography Laser Mammography (CTLM®) system uses laser to image the breast in a non-invasive procedure. Unlike x-ray mammography, CTLM images blood hemoglobin and the process of neoangiogenesis or new vessel formation which is often associated with breast cancer. The CTLM functions somewhat like a conventional CT scanner in that an energy source, a near-infrared (NIR) laser, scans the breast; a computer reconstructs cross-sectional images based on measured optical data. The measured optical values are directly related to the optical effective transport coefficient of the breast tissue. Like CT, the images may be viewed as single slices or as 3D volumes. The Computed Tomography Laser Mammography method is a rather new breast imaging technique, yet studies from diagnostic centers all over the world present it as a promising tool in the imaging of the breast either alone or as an adjunctive to conventional mammography. When applying laser light to biological tissue, the occurrence of a variety of interaction mechanisms is multiple. This diversity is due to specific tissue characteristics as well as laser parameters. Laser radiations induce biological damage in tissues via photochemical, photothermal, and photomechanical interactions. During the CTLM technique of the NIR laser irradiation of the breast tissue, thermal effects take place, which were studied in this thesis with the aid of a Monte Carlo simulation code, the MCSLTT (Monte Carlo Simulation of Light Transport in Tissue) code. With the assistance of the MCSLTT code the simulation of the photon propagation inside the breast tissue and the skin was performed and graphics (appearing the temperature rise (°C) as a function of the depth that the laser light penetrates inside the tissue) and results that concerned the parameters under investigation (the total heat, the maximum photon depth when using different input powers and different medium thicknesses) were extracted. The combination of those results, led to the extraction of useful information and to the quantification of the thermal effects induced on skin and breast tissue and to the quantification of the influence of several parameters on breast’s temperature, when being irradiated with laser beams. Photochemical interactions, photoablation, plasma-induced ablation and photodisruption could as well be examined with the development of a new Monte Carlo simulation code, giving interesting results about the interaction mechanisms observed during the CTLM’ s laser beam irradiation of the breast tissue as an aspect of future work. / Ο καρκίνος του μαστού αποτελεί τον πρωταρχικό παράγοντα θνησιμότητας των γυναικών στις ανεπτυγμένες χώρες. Κατά την διάρκεια των τελευταίων χρόνων, εντούτοις, αρκετές τεχνικές στην απεικόνιση του μαστού έχουν αναπτυχθεί και εφαρμοστεί, με την μαστογραφία ακτινών Χ να αποτελεί ίσως την πιο ευρέως χρησιμοποιούμενη από τις διαγνωστικές μεθόδους καρκίνου. Παρόλο που η μαστογραφία ακτινών Χ ακόμη παραμένει η κύρια διαγνωστική τεχνική στην μάχη κατά του καρκίνου του μαστού και αποτελεί έναν συνεισφέρων παράγοντα στην σταδιακή μείωση των θανάτων από καρκίνο του μαστού, παρουσιάζει συγκεκριμένα μειονεκτήματα τα οποία ποικίλλουν από ψευδή-θετικά αποτελέσματα έως χαμένες αλλοιώσεις καθώς και το ρίσκο της καρκινογένεσης. Έχει εκτενώς τεκμηριωθεί ότι η μαστογραφία, συμβατική ή ψηφιακή, “χάνει” το 25% - 40% των καρκίνων του μαστού, με το ποσοστό να αυξάνει μεταξύ γυναικών με πυκνούς μαστούς οι οποίες και αποτελούν το 40% του γυναικείου πληθυσμού. Εφόσον η μαστογραφία αποτελεί μια προβολική απεικόνιση υπερτιθέμενων δομών μαστού είναι γενικότερα δυσκολότερο να ανιχνευτεί καρκίνος σε έναν μαστό με πυκνή μορφή. Σαν αποτέλεσμα η μαστογραφία παρουσιάζει χαμηλή ευαισθησία (κυμαίνεται από 24.5% έως 37%) ειδικά σε γυναίκες με πυκνούς μαστούς. Αυτό οφείλεται στο γεγονός ότι απεικονίζει μόνο ανατομική λεπτομέρεια και δεν παρέχει λειτουργική πληροφορία που είναι απαραίτητη για την πρώιμη και ακριβή διάγνωση του καρκίνου του μαστού και αναμένεται να μειώσει σημαντικά τον αριθμό των μη απαραίτητων βιοψιών. Οι ειδικές ιδιότητες του φωτός μπορούν να βοηθήσουν την οπτική απεικόνιση να “δει” αυτά που οι άλλες διαγνωστικές μέθοδοι, συμπεριλαμβανομένης και της συμβατικής μαστογραφίας ακτινών Χ, μπορεί να χάσουν. Μία από τις νεότερες τεχνικές στο προσκήνιο, είναι η μαστογραφία laser με μεθόδους υπολογιστικής τομογραφίας (CTLM), ένας υπολογιστικός, τομογραφικός, βασιζόμενος σε ακτινοβολία laser ανιχνευτής για τον μαστό, που μπορεί να ανιχνεύει μεγαλύτερη ροή αίματος (η οποία αποτελεί ένδειξη καρκίνου), χρησιμοποιώντας μία μη ιοντίζουσα πηγή ενέργειας. Το σύστημα CTLM χρησιμοποιεί laser για να απεικονίσει τον μαστό σε μία μη διηθητική διαδικασία. Αντίθετα με την μαστογραφία ακτινών Χ, το σύστημα CTLM απεικονίζει την αιμογλοβίνη του αίματος και την διαδικασία της νέο-αγγειογέννεσης ή του σχηματισμού νέων αγγείων που συχνά σχετίζεται με τον καρκίνο του μαστού. Το CTLM λειτουργεί σαν ένας συμβατικός ανιχνευτής υπολογιστικής τομογραφίας εφόσον η πηγή ενέργειας, ένα laser που εκπέμπει στο εγγύς υπέρυθρο ανιχνεύει τον μαστό και ένας υπολογιστής αναδομεί εικόνες από εγκάρσιες τομές που βασίζονται σε μετρήσιμα οπτικά δεδομένα. Οι μετρήσιμες οπτικές τιμές σχετίζονται απευθείας με τον οπτικό δραστικό συντελεστή μεταφοράς του μαστού. Όπως στην υπολογιστική τομογραφία, οι εικόνες μπορούν να απεικονιστούν σαν ατομικές τομές ή ως τρισδιάστατοι όγκοι. Η μαστογραφία laser με μεθόδους υπολογιστικής τομογραφίας (CTLM) είναι μια σχετικά νέα τεχνική απεικόνισης του μαστού, παρόλα αυτά μελέτες διαγνωστικών κέντρων από όλο τον κόσμο την παρουσιάζουν ως μία πολλά υποσχόμενη μέθοδο στην απεικόνιση του μαστού είτε μόνη της είτε βοηθητικά στην συμβατική μαστογραφία. Κατά την εφαρμογή ακτινοβολίας η μαστογραφία laser με μεθόδους υπολογιστικής τομογραφίας laser σε βιολογικό ιστό, η εμφάνιση διαφόρων μηχανισμών αλληλεπίδρασης είναι πολλαπλή. Η ποικιλία αυτή οφείλεται στα ειδικά χαρακτηριστικά του ιστού καθώς και στις παραμέτρους του laser. Η ακτινοβολία laser προκαλεί βιολογική καταστροφή σε ιστούς μέσω φωτοχημικών, φωτοθερμικών και φωτομηχανικών αλληλεπιδράσεων. Κατά την διάρκεια της NIR laser ακτινοβολίας του μαστού της τεχνικής CTLM, θερμικά φαινόμενα λαμβάνουν χώρα, τα οποία μελετήθηκαν σε αυτή την διπλωματική εργασία με την βοήθεια ενός Monte Carlo κώδικα προσομοίωσης, του κώδικα MCSLTT (Monte Carlo Simulation of Light Transport in Tissue). Με την βοήθεια του συγκεκριμένου κώδικα πραγματοποιήθηκε η προσομοίωση της διάδοσης των φωτονίων εντός του ιστού και του δέρματος του μαστού και ελήφθησαν γραφικές που παρουσίαζαν την αύξηση της θερμοκρασίας (°C) ως συνάρτηση του βάθους που η ακτινοβολία laser φτάνει εντός του ιστού και αποτελέσματα που αφορούσαν τις παραμέτρους υπό διερεύνηση (συνολική θερμότητα, μέγιστο βάθος φωτονίων με χρήση διαφορετικών ισχύων εισόδου και διαφορετικών παχών μέσου). Ο συνδυασμός αυτών των αποτελεσμάτων οδήγηση σε χρήσιμες πληροφορίες και στην ποσοτικοποίηση των θερμικών φαινομένων στο δέρμα και στον ιστό του μαστού καθώς και στην ποσοτικοποίηση της επίδρασης αρκετών παραμέτρων στην θερμοκρασία του μαστού όταν αυτός ακτινοβολείται από δέσμες laser. Οι φωτοχημικές αλληλεπιδράσεις, η φωτοαποκόλληση, η αποκόλληση επαγόμενη από πλάσμα και η φωτοδιάσπαση θα μπορούσαν να μελετηθούν σε μία μελλοντική εργασία με την ανάπτυξη ενός νέου Monte Carlo κώδικα προσομοίωσης, οδηγώντας στην εξαγωγή συμπερασμάτων σχετικά με τους μηχανισμούς αλληλεπίδρασης κατά την διάρκεια της CTLM μεθόδου ακτινοβόλησης του μαστού.

Page generated in 0.0314 seconds