1

Estrategias de realimentación de los convertidores continua-continua. Casos lineal y no lineal

Majó Roca, Joan 01 March 1990 (has links)
ESTA TESIS HA TENIDO POR OBJETO EL DISEÑO Y REALIZACION DE ESTRATEGIAS DE REALIMENTACION PARA REGULADORES CONMUTADOS CONTINUA-CONTINUA, QUE CONTEMPLAN LOS SIGUIENTES ASPECTOS: A) MODELACION LINEAL. EFECTO DE LA REALIMENTACION DE ESTADO Y DE LA PREALIMENTACION EN EL FUNCIONAMIENTO DE LOS CONVERTIDORES CONTINUA-CONTINUA. B) MODELACION NO LINEAL. ESTUDIO DE VIABILIDAD DE LA TRANSFORMACION BILINEAL-LINEAL EN LOS CONVERTIDORES ELEMENTALES PARA EL DISEÑO DE NUEVAS TECNICAS DE CONTROL NO LINEAL. C) APLICACION DEL CONTROL NO LINEAL EN CONVERTIDORES DE ORDEN ELEVADO. D) DISEÑAR CIRCUITOS DEL CONTROL NO LINEAL QUE PERMITAN MEDIANTE PSEUDOLINEALIZACION, ALCANZAR EL COMPORTAMIENTO GLOBALMENTE ESTABLE DE LOS CONVERTIDORES CONTINUA-CONTINUA ELEMENTOS ("BUCK", "BOOST" Y "BUCK-BOOST"). E) EXTENDER EL DISEÑO ANTERIOR AL CASO DE CONVERTIDORES DE ORDEN ELEVADO ("LUK") Y PARTICULARIZANDOLO EN LAS SITUACIONES DE DISMINUCION DE ORDEN QUE ALGUNO DE ESTOS CONVERTIDORES PERMITAN. F) DETERMINAR EXPERIMENTALMENTE LAS PRESTACIONES DEL REGULADOR CONMUTADO QUE UTILIZA EL CIRCUITO DE CONTROL LINEAL DESARROLLADO EN LA FASE ANTERIOR.
2

Modelización de interruptores eléctricos de potencia

Giménez Gutiérrez, Walter Fernando 02 June 2000 (has links)
El desarrollo informático en los últimos años ha posibilitado la utilización de computadoras para simular el comportamiento de los componentes de una red eléctrica, a través de la utilización de modelos matemáticos. Los interruptores de potencia, como parte de cualquier red eléctrica, están representados por modelos que deben garantizar una correcta representación del arco eléctrico que se forma durante la operación de cierre o apertura del interruptor.Actualmente, existen en funcionamiento distintos tipos de interruptores operando a distintos niveles de tensión. Este trabajo consiste en el desarrollo de una metodología capaz de ser utilizada a cualquier nivel de tensión y en los tipos más habituales de interruptores de potencia, a partir de los datos obtenidos en ensayos de cortocircuito.Se presentan los modelos matemáticos más usuales, junto con una nueva forma de tratar el comportamiento de los parámetros involucrados a través de su implementación en un programa de simulación. La realización de ensayos en laboratorio ha permitido extrapolar la metodología hacia otros niveles de tensión, corriente y tipo de interruptor; los cuales demostraron una total aplicabilidad tanto de los programas de cálculo, que han sido especialmente confeccionados, como de los modelos matemáticos empleados en las simulaciones respectivas.Más allá de la teoría desarrollada, la utilidad práctica de esta trabajo radica en brindar una nueva herramienta para el análisis del comportamiento de los interruptores de forma metódica, que permita su utilización en otros ámbitos de investigación, desmitificando la concepción del arco eléctrico. / The computer development in the last years has made possible the computers utilization to simulate the behaviour of the components of an electrical network, through the mathematical models utilization. The power switches, as part of any electrical network, are represented by models that they should guarantee a correct representation of the electrical arc that is formed during the close or opening operation of the circuitbreaker.Currently, they exist in different operation types of switches operating at different tension levels. This work consists of the development of a capable methodology to be used at any tension level and in the most common types of power switches, as of the data obtained in short circuit tests. They are presented the more usual mathematical models, together with a new form to test the behaviour of the parameters involved through its implementation in a simulation program.The tests accomplishment in laboratory has permitted to extrapolate the methodology toward other tension and current levels, and type of switch; those which demonstrated a total applicability so much of the calculation programs, that they have been especially made, as of the particular mathematical model in the respective simulations. Beyond the developed theory, the practical usefulness of this work bases in offering a new tool for the behavioural analysis of the switches in a methodical way, that permit its utilization in other investigation areas, demystifying the conception of the electrical arc.
3

Aportaciones al estudio del flujo armónico de cargas

Herraiz Jaramillo, Sergio 03 July 2002 (has links)
La distorsión armónica no es un fenómeno nuevo en los sistemas eléctricos de potencia, pero desde principios de los años setenta se ha convertido en un problema de creciente actualidad debido al incremento considerable de las cargas contaminantes en las redes eléctricas, en especial, de los dispositivos semiconductores y la electrónica de potencia. A causa del incremento de la presencia de dichas cargas no lineales, la distorsión armónica de las tensiones y corrientes ha ido aumentando produciendo un mal funcionamiento de los distintos elementos de los sistemas eléctricos.Los estudios e investigaciones iniciados en los años setenta en el campo de los armónicos en los sistemas eléctricos de potencia, han avanzado considerablemente a nivel internacional desde principios de los ochenta. Actualmente, la bibliografía tiende cada vez más a presentar trabajos de refinamiento sobre las técnicas desarrolladas para el estudio armónico.Enmarcada en este contexto, la tesis realiza una serie de aportaciones en algunos aspectos concretos del análisis armónico en sistemas eléctricos de potencia:· Estudios realizados sobre la calidad en el suministro eléctrico. En primer lugar se realiza un resumen sobre las transformadas al dominio de la frecuencia y sobre la situación actual referente a índices de calidad y normativas. Posteriormente, se presenta el estudio y la caracterización de un nuevo índice de calidad para señales aperiódicas, para las cuales los índices más comunes en la actualidad no son estrictamente aplicables. Se presenta también el estudio de la cuantificación del error que se comete, al aplicar la transformada discreta de Fourier, en el cálculo de armónicos de tensiones y corrientes del sistema con el fin de determinar su distorsión.· Estudio y modelización de rectificadores no controlados con filtro capacitivo monofásicos y trifásicos en conducción discontinua. Para el primero de ellos, se realiza una completa caracterización gráfica de su comportamiento, que permite analizar la influencia de los parámetros del dispositivo en dicho comportamiento. Se desarrolla un modelo analítico del rectificador cuando su punto de operación se define a partir de su corriente de continua consumida o de su potencia consumida y, por último, se utiliza el modelo propuesto para el estudio y aplicación de la normativa referente a la contaminación armónica. En cuanto a los rectificadores trifásicos, se desarrolla un modelo analítico que determina su comportamiento en modo de conducción discontinua cuando su punto de operación se define a partir de su corriente de continua consumida o de su potencia consumida. También se utiliza el modelo propuesto para el estudio y aplicación de la normativa referente a la contaminación armónica.· Se recoge una completa recopilación de los distintos enfoques de la formulación del flujo armónico de cargas, en condiciones equilibradas y desequilibradas, aparecidos en la bibliografía. El objetivo del estudio consiste en clasificar las numerosas formas de tratar el problema armónico en el dominio de la frecuencia y se completa con el balance, en condiciones equilibradas, de los datos, incógnitas y ecuaciones planteadas en cada formulación existente. Completando lo anterior, se analizan, a partir de dos ejemplos, las dos hipótesis más importantes en el enfoque del problema armónico: la influencia de la interacción armónica en el comportamiento de los dispositivos no lineales, y la consideración de la potencia sólo con su componente fundamental, y como pueden influir en el planteamiento y en los resultados finales del estudio. / Harmonic distortion is not a new phenomenon in electric power systems but, since the early 1970s it has been growing interest problem due to the increase of contaminating loads in networks, particularly, semiconductor devices and power electronics. Because of the increase of these non linear loads, voltage and current harmonic distortion is augmenting, which is giving rise to the wrong operation of elements in electric systems.Studies and researches starting in the 70's in the area of harmonics in electric power systems have made progress since the early 1980s. At present, the bibliography tends to present detailed works about techniques developed for the harmonic study.In this context, the thesis makes a set of contributions in some particular aspects related to the harmonic analysis in electric power systems:· Studies of electric power quality. First, a summary on transforms in the frequency domain and on the current situation of power quality indices and regulations is given. Secondly, the study and characterization of a new power quality index for non-periodic signals, for which the most common indices are not suitable, is presented. Lastly, the error made in the application of the Fourier transform in the electric power system harmonic analysis, when it is used in the discrete signal treatment, is studied.· Study and modelling of uncontrolled single-phase and three-phase rectifiers with capacitive filter in discontinuous conduction. For the former, a complete graphical characterisation of its behaviour is made, which allows the influence of parameter devices to be analysed. An analytical model of the rectifier is developed when its working point is defined starting from its consumed direct current or its consumed power. The proposed model is used in the study and application of the standard concerning harmonic pollution. As regards the three-phase rectifier, an analytical model, which determines its behaviour in discontinuous mode when its working point is defined by its continuous direct current or its consumed power, is developed. The proposed model is used in the study and application of the standard concerning harmonic pollution.· Complete compilation of the different approaches in the formulation of harmonic load flow, in balanced and unbalanced conditions, that appear in the bibliography. The study classifies the large number of ways of tackling the harmonic problem in the frequency domain, and it is completed with the data, unknowns and equations in balanced conditions, in each existing formulation. In order to complete the study, the two most important hypothesis made in the harmonic problem are analysed: the influence of harmonic interaction in the behaviour of non-linear devices, and the consideration of power depending only on the fundamental component, and how they can influence in the formulation and the final results.
4

Aportaciones al estudio de los motores de inducción magnetohidrodinámica

Massagues Vidal, Lluís 27 July 2001 (has links)
de Tesis DoctoralNos proponemos plantear un método de cálculo que nos permita la construcción de un motor de inducción magnetohidrodinámica, la impulsión de fluidos conductores por campos magnéticos.El inductor de este tipo de máquinas eléctricas es similar a las máquinas lineales, y el inducido es una lámina conductora, cuyas características dependerán del tipo de fluido a impulsar.Se propone un método de cálculo de las máquinas eléctricas lineales tanto planas como tubulares, para posteriormente aplicarlo en la construcción de varios prototipos. El método de trabajo es experimental y teórico.Se diseñan tres prototipos bien diferenciados, los tres se han ensayado con un inducido sólido (aluminio) por la facilidad de su manejo y posteriormente se han ensayado dos con un fluido (agua saturada de sal) . El primer prototipo, es un motor lineal plano bilateral con un inductor alimentado a una fuente de tensión trifásica a 50 Hz, llamado M-1. La alimentación de este prototipo se hace a través de un regulador de tensión. Este prototipo se diseña con la finalidad de comprobar la viabilidad de la impulsión de fluidos por campos magnéticos. Posteriormente se construye dicho prototipo y se ensaya, los resultados se ofrecen en tablas y gráficas y se hacen las oportunas reflexiones. Después se construye una máquina lineal tubular bifásica, alimentada con una fuente de corriente a 50 Hz, llamada M-2. La potencia en bornes se consigue por variación de la tensión aplicada a la máquina. Este nuevo prototipo se diseña con varias finalidades, una de ellas es la comprobar la viabilidad de utilizar superconductores en las máquinas lineales, se trabaja con un solo conductor por ranura, para que tramos de conductor rígido puedan ser sustituidos por superconductor. Otra finalidad es la de comprobar la eficacia de un devanado bifásico en este tipo de máquinas. Este prototipo es construido y ensayado, ofreciendo los resultados en gráficas y tablas.Se construye una tercera máquina lineal tubular monofásica con espira de sombra, alimentada con una fuente de alta frecuencia, y con una fuente de Alta Tensión. Con este prototipo se quieren comprobar limitaciones de las máquinas lineales, una de ellas es la del acoplamiento magnético entre inductor e inducido a 5000 Hz, para ello se ha tenido que eliminar todo el hierro del inductor e inducido, también se quiere comprobar la eficacia del devanado inductor que es monofásico con espira de sombra. Los resultados de los tres prototipos construidos nos permiten contrastarlos con el método de cálculo propuesto, así como ver la tendencia de esta línea de trabajo. Como hechos más representativos, se puede citar, haber trabajado con un solo conductor por ranura, a alta frecuencia, la importancia de los devanados inductores en el diseño de estas máquinas, la convicción que hay que tender a potencias muy elevadas para impulsar fluidos, y que las máquinas para impulsarlos deben ser tubulares.Ph Doctoral Thesis / We intend to propose a calculation method that allow us to assemble a magnetohydrodynamic induction engine.The inductor in this kind of electrical machines is similar to that of linear machines, and the inducted part is a conductive blade, whose characteristics will depend on the type of fluid being thrusted.We are introducing a calculation method for linear electrical machines, be them plane or tubular, in order to apply it to the assembly of several prototypes. The working method is both experimental and teorethical.We have designed three well differentiated prototypes. The three of them have been tested with a solid inducted element (aluminium) because of its ease of use and, later on, two of them have been tested with a liquid fluid (salt saturated water).The first prototype is a bilateral flat linear engine with an inductor being powered by a 50Hz triphase source, called M-1. The power supply of this prototype is carried on through a power regulator. This prototype's design aims to test the feasibility of fluids thrusting by magnetic fields. Later on, the prototype is built up and tested. Results are presented in tables and charts, with the pertinent comments and discusions.Then, we build a biphase tubular linear machine, powered by a 50Hz source, called M-2. Power at the terminals is obtained by the power variation being applied to the machine. This new prototype is designed with several goals in mind. One of them is to check the viability of using superconductors in linear machines. In this case, we work with only one conductor per slot, so that some sections of this rigid conductor can be replaced by superconductors. Another target is to evaluate the efficiency of a biphase winding in this kind of machines. The prototype is built up and tested, which offers us the results being presented in tables and charts.We build a third machine, being it a monophase tubular linear machine with shading ring, powered by a high frequency source and a high tension source. With this prototype we want to check the limitations of the linear machines, one of them being the magnetic coupling between the inductive and inducted parts at 5000Hz. In order to do that, we had to remove all the iron from them (inductor and inducted). We also wanted to test the efficiency of the inductor winding, which is monophase with shading ring.The results of all the three built prototypes, allow us to compare them with our suggested calculation method, as well as the trend in this line of work.Some of the most relevant results have been to work with only one conductor per slot at a high frequency, the importance of inductive windings in the design of this machines, the conviction that thrusting fluids require a great amount of power, and finally that the machines needed to thust these fluids must be tubulars.
5

Evaluación estadística del comportamiento de líneas aéreas de distribución frente a sobretensiones de origen externo.

González Molina, Francisco 29 October 2001 (has links)
de la Tesis DoctoralIntroducciónExisten muchas causas por las que se pueden originar sobretensiones en una red de potencia. La clasificación más aceptada distingue tres tipos de sobretensiones: Sobretensiones temporales, sobretensiones de maniobra, y sobretensiones de origen atmosférico. No existe una frontera muy clara entre un tipo y otro de sobretensión; por ejemplo, una sobretensión originada por un cortocircuito es de tipo temporal, pero transitoriamente puede ser calificada como sobretensión de maniobra.En redes de tensión nominal inferior a 400 kV las sobretensiones debidas al rayo son más peligrosas que las debidas a otra causa, mientras que por encima de 400 kV las sobretensiones de maniobra suelen ser las más peligrosas.La importancia de las sobretensiones atmosféricas crece conforme disminuye la tensión nominal de los componentes afectados por el rayo. El valor de las sobretensiones que se pueden producir en una red de distribución originadas por un rayo es tan elevado frente al valor de la tensión nominal de la red que tanto el nivel de aislamiento de los componentes como la selección y coordinación de protecciones se realiza teniendo en cuenta el efecto de las sobretensiones atmosféricas. En general, el nivel de las sobretensiones de origen interno es inferior o muy inferior al nivel de aislamiento de los componentes de una red de distribución, siendo el número de averías originadas por una sobretensión de este tipo mucho más reducido que el originado por sobretensiones atmosféricas directas o inducidas por el rayo.Esta Tesis Doctoral está dedicada exclusivamente a la evaluación de líneas de distribución frente a sobretensiones de origen atmosférico. Este estudio ha sido objeto de gran atención durante los últimos años y existe una abundante literatura centrada exclusivamente en este campo. Sin embargo, todavía existen muchos puntos sobre los que no hay un conocimiento suficientemente preciso; probablemente, los más importantes sean la propia naturaleza del rayo y los principales parámetros que describen su comportamiento.ObjetivoEl objetivo principal de esta Tesis Doctoral es el cálculo de la tasa de contorneamientos por sobretensiones atmosféricas en líneas aéreas de distribución con y sin apantallamiento en función de los parámetros más característicos del rayo y de la línea, así como de la actividad atmosférica de la zona por donde transcurre la línea.Estructura y contenidoEl Capítulo 1 contiene una introducción al trabajo realizado.En el Capítulo 2 se resumen los antecedentes y los objetivos de esta Tesis Doctoral.En el Capítulo 3 se presenta una introducción al proceso de descarga de una nube, y se detallan los parámetros más importantes de un rayo.En el Capítulo 4 se realiza un análisis del comportamiento de líneas aéreas de distribución frente al rayo. El cálculo de sobretensiones se realiza de dos formas diferentes, mediante algoritmo y mediante simulación digital con el programa EMTP/ATP.El Capítulo 5 está dedicado al cálculo de la tasa de contorneamientos en líneas aéreas de distribución debidos a descargas atmosféricas. El cálculo se realiza de manera sistemática, y de manera estadística aplicando el método de Monte Carlo.En el Capítulo 6 se analiza el comportamiento de líneas aéreas de distribución frente al rayo empleando redes neuronales. El cálculo de la tasa de contorneamientos se realiza de manera estadística aplicando el método de Monte Carlo.El Capítulo 7 presenta las conclusiones más importantes de los diferentes estudios realizados.El Capítulo 8 incluye una bibliografía muy completa sobre el tema. / of the PhDIntroductionOvervoltages in electrical power networks can be originated by several different causes. The most accepted classification differentiates 3 types of overvoltages: Temporary overvoltages, switching overvoltages, and lightning overvoltages. It doesn't exist a very clear edge between them; for example, an overvoltage caused by a short-circuit is usually a temporary overvoltage, but transiently can be qualified as a switching overvoltage.Lightning is the most dangerous overvoltage in a power network with a rated voltage less than 400 kV. However, switching overvoltages are the most important in networks with a value of the rated voltage higher than 400 kV.The importance of lightning overvoltages increases with the decrease of the rated voltage of the affected components. The value of the lightning overvoltages produced in a distribution network is so high in front of the value of the rated voltage of the network than the insulation level of the components and the selection and the co-ordination of protections are carried out by taking into account the effect of lightning overvoltages. In general, the level of the overvoltages due to internal causes is less than the insulation level of the components of a distribution network, being the number of faults caused by this type of overvoltage much more reduced than this caused by external overvoltages (direct or induced by the lightning).This PhD is dedicated exclusively to the evaluation of distribution overhead lines in front of lightning overvoltages. This study has been very important during the last years and there is a lot of information focused in this field. However, there is several points where the knowledge is not enough yet; probably, the most important are the own nature of lightning and the main parameters which describe this behaviour.ObjectivesThe main goal of this PhD is the calculation of the flashover rate of lightning overvoltages for distribution overhead shielded and unshielded lines in function of the most important lightning and line parameters, as well as the atmospheric activity.Structure and contentsIn Chapter 1 is the introduction of the study carried out.In Chapter 2 are summarised the antecedents and the objectives of this PhD.In Chapter 3 an introduction of the discharge process of a cloud is presented, and also the most important lightning parameters are described.In Chapter 4 is carried out an analysis of the lightning performance of distribution lines. The calculation of overvoltages is carried out in a two different ways, by means of algorithm and by means of digital simulation with the EMTP/ATP program.Chapter 5 is dedicated to the calculation of flashover voltages in distribution overhead lines. The calculation is carried out in a systematic way and also in a statistical way by applying the Monte Carlo method.In Chapter 6 the lightning performance of overhead lines is done by means of neural networks. The flashover voltage calculation is carried out in a statistical way by applying the Monte Carlo method.Chapter 7 presents the most important conclusions of the different studies carried out in this work.Chapter 8 includes a very complete bibliography about the studied subject.
6

Aplicación de las redes neuronales en los sistemas de control vectorial de los motores de inducción

Sowilam, Gamal 25 September 2000 (has links)
Últimamente se ha incrementado considerablemente la utilización de la inteligencia artificial en los campos de la electrónica de potencia y de los sistemas de control de la velocidad y del posicionamiento. Estos métodos, basados en sistemas expertos, la lógica difusa y las redes neuronales artificiales, necesitan una gran base de datos o conocimientos que describan el funcionamiento del sistema junto a un análisis lógico, en lugar del análisis matemático, para controlar el sistema y facilitar la toma de decisiones. Uno de estos métodos corresponde a las redes neuronales artificiales.En esta tesis doctoral se presenta la aplicación de redes neuronales artificiales en los sistemas de control vectorial y control directo del par para una máquina de inducción. Esta tecnología, relativamente nueva, sirve para poder reemplazar eficientemente algunos equipos analógicos ya existentes. Los datos necesarios para entrenar las redes neuronales artificiales se obtienen, en primer lugar, de los resultados de las simulaciones del sistema formado por el motor y su control, y en segundo lugar, a partir de los resultados experimentales. A tal fin se implementa un modelo del motor de inducción que se prueba con motores de diferentes valores nominales y se controla con diferentes sistema de control: control vectorial por el método indirecto con y sin realimentación de velocidad, control vectorial por el método directo con realimentación de velocidad y control directo del par. Para el caso de los sistemas del control vectorial por el método indirecto, con y sin realimentación de velocidad se han utilizado redes neuronales artificiales de respuesta a impulso finito (FIRANN) para emular algunos bloques de los sistemas del control vectorial tales como la estimación de referencia de corriente estator. Cada red neuronal artificial se ha diseñado, entrenado y probado como una parte del conjunto del sistema de control. Con respecto al control vectorial por el método directo y con realimentación de velocidad, se estima la referencia de la corriente del estator y también se realiza la mayor parte del control vectorial con redes neuronales artificiales FIRANN. Cada red neuronal artificial se ha diseñado, entrenado y probado como una parte del conjunto del sistema de control.Para el sistema de control directo del par se han utilizado redes neuronales artificiales de propagación hacia adelante (MFANN) que emulan la tabla de conmutación del ondulador, la transformación de las tensiones en el sistema de referencia "abc" al sistema de referencia fijado al estator "dq", la transformación de las corrientes de estator en el sistema de referencia "abc" al sistema de referencia fijado al estator "dq" y por último, un estimador de par. Estas cuatro redes neuronales se probaron en línea tanto de forma independiente como conjuntamente. Su comportamiento ha sido bueno en comparación con el sistema sin redes neuronales. Además, se realizó la implementación física del equipo para el control en tiempo real de un motor de inducción por el método directo clásico, y usando redes neuronales mediante una tarjeta dSPACE "DS1103". Este montaje ha permitido hacer las medidas necesarias para poder comparar el comportamiento del sistema bajo las alternativas propuestas. / Recently, the use of artificial intelligence has been increased in the fields of power electronics, and position and speed control systems. These methods, based on expert systems, fuzzy logic and artificial neural networks, require a large data base or knowledge to describe the operation of the system, besides to the logic analysis instead of the mathematical analysis in order to control the system and facilitate the decision tasks. One of these methods are the artificial neural networks.This doctoral thesis shows the aplication of artificial neural networks to the vector control systems and direct torque control of induction machines. This technology is useful to replace some existing analogical equipment in an efficient way. The data needed to train the artificial neural networks is obtained in the first place from the simulation results of the system, and in the second place from the experimental results. For that purpose, it was implemented an induction motor model which is tested with different machine characteristics, and it is controlled with different control systems: indirect method vector control with and without speed feedback, direct method vector control with speed feedback and direct torque control.For indirect method vector control with and without speed feedback, it has been used finite impulse response artificial neural networks (FIRANN) to emulate some blocks of the vector control systems such as the estimation of the stator current. Each artificial neural network has been designed, trained and tested as a part of the control system set.For the case of direct method vector control with speed feedback, the stator current reference and the majority of the vector control is realized also with artificial neural networks FIRANN. Each artificial neural network has been designed, trained and tested as a part of the control system set.In the direct torque control, it has been used feed-forward artificial neural networks (MFANN) to emulate the commutation table of the inverter, to develop the transformation of the voltages from the "abc" reference frame to the "dq" reference frame, and the transformation of the stator currents from the "abc" reference frame to the "dq" reference frame, and finally, to estimate the torque. These four neural networks have been tested online in an independent way and also as a whole. Its performance has been good in comparison with the system without neural networks.Finally, it was realized a physical implementation of the equipment for real time control of an induction motor by the classical method and by artificial neural networks using a dSPACE "DS1103" card. This implementation has allowed realize the measurements to be able to compare the performance of the system under the different proposed alternatives.
7

Novel piezoelectric transducers for high voltage measurements

Vázquez Carazo, Alfredo 14 April 2000 (has links)
A prerequisite for safe and stable operation of an electric power system is the accurate and reliable measurement of the system parameters, in particular, current and voltage. Conventionally, this has been achieved on High Voltage (H.V.) systems by expensive, bulky iron-core transformers and also by capacitor transformers. Both of them are increasingly coming under review (chapter 1) in modern power system due to their cost, safety implications for personnel and surrounding plant if failure occurs, installation time and indeed substation land requirements. Research effort into viable alternatives to instrument transformers has been ongoing for many years to reduce the cost and improve the safety and accuracy of this devices. In the last years, this research has accelerated due to the new requirements of the modern metering and protection systems based on electronic and microprocessor devices. This trend in the modern systems has allowed the development of novel transducers where the accuracy, the reliability and the safety has been significantly improved. The main alternative incorporate optic fibre viewed as the most realistic method of providing cheap and safe isolation between the chosen sensor at phase potential and earth. The sensor itself is, in the case of current measurement, based on the Faraday effect while in the case of the voltage measurement is generally a Pockels or Kerr effect device measuring a fraction of the actual phase voltage by employing a capacitive voltage divider.In parallel to the development of the optical alternative other different transducers have been studied based on the properties offer for new materials and technologies developed in the last years. A clear example of new emergent technologies is found in the piezoelectricity (chapter 2).In just over 100 years piezoelectricity has moved from a laboratory curiosity to big business. During this period, several technologies have been developed to utilise the piezoelectric effect.In turn, each of these technologies has become an essential component in many kinds of electronic products. The U.S. piezoelectric industry, good mirror for analyse the internationaltechnologic development, has gone through several boom and bust cycles. However, new applications are emerging for piezoelectricity because of the developments in piezoelectric ceramics and polymers. Even though piezoelectric quartz crystal still holds the largest marketsegment, several new piezoelectric ceramic and piezoelectric polymer materials are being developed that represent good, attractive market segments in terms of growth, competition, and investment.This thesis proposes an alternative for the measurement in High Voltage environments by using the piezoelectric technology. The thesis was initially concentrated in the alternative of the voltage measurement, but the successfully results in this field have open the way to propose alternatives for measuring current.Accordingly, the present thesis develops a novel instrument transformer based on the mechanical forces developed for the piezoelectric materials under the influence of an electric field. The transformer consists of an actuator piezoelectric column and a sensor piezoelectric column. The actuator column is connected to the a.c. High Voltage to be measured. This electrical voltage produces the generation of mechanical forces within the material. The forces can be measured by means of the piezoelectric sensor and convert it back into a low electrical signal which can drive an electronic protection or measuring system. The novel piezoelectric transformer herein treated is of wide application in electrical networks for measuring, providing both advantageous accuracy and large transformation ratio. Furthermore, It is expected to reduce the volume, weight and manufacturing cost of the traditional electromagnetic transformers.
8

Estudio y realización del control directo del par (DTC) para accionamientos de motores de inducción con inversores de diferentes topologias

Moustafa Azab, Mohamed Ahmed 06 September 2002 (has links)
El objetivo principal de la tesis es la aplicación del método de control directo del par para un motor de inducción utilizando inversores de diferentes estructuras que parecen ofrecer algunas ventajas, bajo ciertas condiciones, y que aún no han sido utilizados para el desarrollo de esta técnica de control.La idea y el tema de la tesis surgieron de la gran importancia del método control directo del par (DTC), que últimamente se planteó como estrategia alternativa del control vectorial debido a ciertas ventajas frente a este último. Por este motivo, y animados por el éxito logrado por el DTC, se quiere contribuir a un aumento del mismo utilizando varias topologías de inversores que amplíen o extiendan el área de aplicación de los accionamientos basados en el mismo en un rango que vaya desde bajas potencias hasta las potencias medianas. Aunque los objetivos principales de aplicar el DTC son obtener un accionamiento de comportamiento dinámico alto y buen funcionamiento durante el régimen estático, no obstante los requisitos de funcionamiento en el rango de las bajas potencias no son los mismos que aquellos de potencias medianas. En el rango de las bajas potencias, el coste total del conjunto del accionamiento (inversor - motor - circuitos de control) es un factor muy importante. Especialmente con las normas europeas que obligan a los fabricantes de inversores a mejorar la utilización de la red por ejemplo, limitando la tasa de distorsión armónica, y mejorando el factor de potencia, con lo cual se sustituyen el rectificador pasivo (diodos) por un rectificador activo (transistores), lo que aumenta el coste del accionamiento. Evidentemente, cualquier ahorro en el coste del inversor y los sensores permitirá la aplicación del DTC en gran escala. Por tanto, se ha elegido un inversor de cuatro interruptores (B4) que permite disminuir el coste del inversor y su circuito de control. Reduciendo también el número de sensores utilizados en el sistema. Esta técnica es nueva para este tipo de inversor, ya que el DTC nunca se había realizado basado en este esquema de inversor. Los estudios realizados en esta tesis mediante la simulación y sus validaciones experimentales han probado el buen comportamiento dinámico y estático del accionamiento.De otro parte, en el rango de potencia mediana (10 kW-100 kW) la aplicación del DTC esta limitada por la frecuencia de conmutación. La exigencia de una frecuencia de conmutación elevada hace aumentar las pérdidas de conmutación a través los interruptores del inversor. Los problemas generados por la conmutación rígida impiden subir la frecuencia de conmutación por encima de unos pocos cientos de hertz. Por ello, si el algoritmo del DTC se aplica teniendo en cuenta la limitación de la frecuencia de conmutación a estos pequeños valores, su comportamiento será bastante malo generando una distorsión en las formas de las ondas del par y del flujo, lo que a su vez se refleja en la velocidad y en las corrientes del motor. Para evitar estos problemas sería más conveniente utilizar un inversor resonante, pero también éste tiene algunos inconvenientes. En la tesis, se propone utilizar un inversor de tipo cuasi-resonante que tiene las ventajas de inversor resonante y las ventajas del inversor de conmutación dura. En tal caso, se conmutan los interruptores bajo la condición de cero tensión (ZVS) bajando al mínimo las pérdidas de conmutación lo que finalmente permite aumentar la frecuencia de conmutación hasta valores elevados del orden de 10 kHz. Además, la utilización de este tipo de inversor ofrece algunas ventajas como:- Limitar la dv/dt de la tensión que alimenta el motor, por tanto las corrientes de fugas parásitas se disminuyen, reduciendo la degradación o el envejecimiento de los aislantes de los devanados y de los cojinetes de la máquina, prolongando su vida útil.- Bajar el nivel de las interferencias electromagnéticas.- Reducir el tamaño de los radiadores de calor necesarios.Se ha diseñado y construido un inversor cuasi-resonante con los correspondientes circuitos de control para aplicar el DTC a los accionamientos de baja potencia. Además, se han desarrollado dos circuitos de resonancia. Los resultados obtenidos por simulación y los ensayos experimentales han probado el buen comportamiento de estos circuitos. En cuanto a la escritura de la tesis, esta estructurada en los ocho capítulos siguientes:Capítulo 1: Presenta el estado del arte relacionado al tema de la tesis.Capítulo 2: Estudio introductorio en el que se presenta el control directo del par mostrando sus respectivas, ventajas e inconvenientes. Capítulo 3: Se hace un repaso de las estrategias de control utilizadas en el caso de un inversor de cuatro interruptores, empezando con las estrategias básicas hasta llegar a la estrategia del DTC propuesta en esta tesis. Además, se muestran los resultados de las simulaciones con las diferentes estrategias de control.Capítulo 4: Se explica el funcionamiento del inversor cuasi-resonante, mediante un ejemplo de circuito de resonancia. Además se plantea otro circuito que se ha modificado para mejorar la respuesta y el funcionamiento del inversor. También, se presenta el sistema del DTC basado en este tipo de inversor. Capítulo 5: Se estudia el efecto del cambio de la resistencia del estator sobre el comportamiento del DTC. Además, se presentan algunos métodos para estimar el valor actual de la resistencia del estator durante el arranque y también durante el funcionamiento en régimen permanente.Capítulo 6: Se muestran los resultados experimentales obtenidos del desarrollo de los sistemas propuestos bajo varias condiciones de funcionamiento.Capítulo 7: Se presentan y discuten las conclusiones, y se proponen trabajos a realizar en el futuro.Capítulo 8: Incluye la bibliografía.
9

Diseño de un rele neuronal de protección para lineas aéreas de AT con preprocesado de señal mediante la transformada Wavelet

Iglesias Lorenzo, Javier 29 January 2004 (has links)
El avance de las tecnologías de los microprocesadores y ordenadores ha permitido sustituir las protecciones electromecánicas y analógicas clásicas por protecciones digitales. Sin embargo, los algoritmos empleados en éstas últimas tienen serias dificultades cuando las señales procedentes de los transductores de las corrientes y tensiones están afectadas por la saturación de los mismos o por efectos de ferrorresonancia respectivamente, o cuando la falta que se presenta en la línea está afectada por un arco dinámico.Por otro lado, en los últimos años se habían hecho pequeños avances en la aplicación de la inteligencia artificial y en especial en redes neuronales a los sistemas de energía eléctrica. Éstas resultaban especialmente útiles en la predicción del flujo de carga y en la clasificación de patrones de faltas. El término clasificación de patrones engloba un amplio marco de problemas de procesado de información de gran importancia práctica. Con frecuencia estos problemas se resuelven mediante técnicas estadísticas, desarrollando un algoritmo capaz de clasificar un correctamente un patrón no visto anteriormente. Una aproximación al reconocimiento estadístico de patrones se realiza mediante el teorema de Bayes, que expresa la probabilidad de que un patrón pertenezca a una determinada clase, expresando ésta probabilidad a posteriori en función de medidas realizadas previamente. En función de las características observadas se divide el espacio en regiones de decisión separadas por fronteras de decisión o clasificación. Análogamente, las salidas de una red neuronal se pueden interpretar como las probabilidades obtenidas a partir de la función de error (minimizar la función error durante el entrenamiento de la red neuronal es equivalente a buscar la máxima probabilidad), y la red neuronal aproxima las fronteras del clasificador Bayesiano óptimo.Ante estos hechos, y la gran ventaja que supone el modo de trabajo en paralelo de las redes neuronales, nos propusimos como objetivo buscar nuevos caminos en el campo de las protecciones de las redes eléctricas por medio del estudio de las redes neuronales de sistemas de protección que resuelvan los problemas anteriormente apuntados.La metodología empleada consistió en el entrenamiento de los diferentes tipos de redes neuronales utilizadas en los relés de protección mediante datos generados, para distintos tipos de fallos, con un programa de transitorios electromagnéticos (EMTDC/PSCAD) aplicado a un modelo de red muy general que incluye todas las posibles topologías y niveles de carga. Estos patrones fueron empleados para entrenar las redes neuronales mediante un programa en C++ realizado por el autor.También se incorporó en este trabajo, el estudio y la aplicación de la transformada wavelet, que presenta una serie de ventajas frente a métodos tradicionales de procesado de señales. Entre las herramientas tradicionales de análisis de sistemas eléctricos de potencia, se encuentran numerosos algoritmos, basados entre otros, en la transformada de Fourier, filtros de Kalman, etc. Sin embargo, si ocurre un transitorio, las formas de onda asociadas son no periódicas, conteniendo oscilaciones de alta y de baja frecuencia superpuestas a la frecuencia de funcionamiento del sistema eléctrico. En tal situación, debido a que la transformada de Fourier realiza un promedio de la contribución de las frecuencias se pierde la localización de la perturbación en el tiempo. El análisis mediante wavelets supera ésta limitación, realizando un procesado de la señal, que proporciona información en tiempo y en frecuencia. Por ello, la transformada wavelet es una potente ayuda para el análisis, estudio e interpretación de los distintos fenómenos transitorios que se pueden presentar en un sistema eléctrico de potencia. Además, en este trabajo se ha implementado la transformada wavelet mediante una red neu-ronal, lo que nos permite integrar dentro de la red neuronal general de reconocimiento de pa-trones, una subred encargada de llevar a cabo el procesado de señal. El funcionamiento en paralelo de la red neuronal con la información suministrada por las wavelets ha permitido incrementar la velocidad y seguridad de la respuesta del relé neuronal en los primeros instan-tes del fallo. Asimismo, uno de los objetivos de este trabajo era realizar la implementación práctica del diseño realizado en un sistema electrónico que permitiera comprobar la eficacia del mismo. Para llevar a cabo el montaje experimental se necesitaba un sistema que permitiera simular los sistemas eléctricos similares a los empleados en el proceso de diseño y entrenamiento del relé. El Departamento de Ingeniería Eléctrica de la Universidad de Bath cuenta con el equipo RTDS, que constituye el complemento del sistema de simulación PSCAD, con el que es posi-ble llevar a cabo la simulación y ensayo de prototipos de equipos eléctricos. Bajo la dirección del Prof. Aggarwal se llevó a cabo las pruebas de laboratorio del relé neuronal que resultaron plenamente satisfactorias. Los alentadores resultados obtenidos son un buen estímulo para el uso de las redes neuronales en las protecciones de alta velocidad para líneas de transmisión de alta tensión ya que hemos obtenido un tiempo de respuesta en la detección en la red neuronal de incluso 1.8 ms para fallos cercanos al relé. El relé también ha dado una buena respuesta frente a ruidos, pérdida de información y cambios bruscos de carga. / The great advance of the microprocessor and computer technology has allowed the electromechanical and analog protection devices to be substituted by digital ones. However, the algorithms used in digital protections have some disadvantages related to the errors caused by current transformer saturation, voltage transformer ferro-resonance or by dynamics arcing faults. Over the past 10 years there have been some advances in the application of artificial intelligence, especially of neural networks, on power system analysis. These applications were useful in the prediction of optimum load flow and fault pattern classification. The term pattern classification encompasses a wide range of information processing problems of great practical significance. Often the framework in which to formulate solutions to pattern recognition is the statistical one, with the develop of an algorithm to be able to correctly classify a previously unseen pattern. One approach to statistical pattern recognition is using Bayes´ theorem, which gives the probability of the pattern belonging to a particular class, and expresses this posterior probability in terms of previous measurements. The space is divided up into decision regions depending on the observed features. The boundaries between regions are known as decision boundaries. The outputs of a neural network can be interpreted as posterior probabilities calculated with the error function (the network training is based on maximum likelihood which is equivalent to minimization of an error function), and the neural network approximates the decision boundaries of the Bayes´ theorem.For these reasons and because of the advantage of the parallel processing capabilities of the neural networks, our objective here is to search for new applications of neural networks on power system protection in order to improve it and solve the problems mentioned above.In order to do this in this thesis, the artificial neural networks are applied to the protection of high voltage transmission lines, assuming dynamic arcing faults, the current transformer saturation, the change of the short circuit levels, the change of the power network topology, the bad and noisy data, and sudden load changes.The methodology carried out in a special training process of the neural networks, using protection relays by means of simulated faults data, obtained by the electromagnetic transient program (EMTDC/PSCAD) applied to a generalized power network model which includes all the possible topologies and load levels. The training algorithm was implemented by the author in the C++ language program.Within this project we included the study and application of the wavelet transform, which showed a series of advantages in front of traditional methods in signal processing. In traditional power signal analysis tools, among several algorithms, the Fourier transform has been used as well as the Kalman filtering, etc. However, in presence of non stationary signals the performance of these techniques are limited. Thus, if there is a local transient over some small interval of time in the lifetime of the signal, the transient will contribute to the Fourier transform, but its location on the time axis will be lost. Wavelets analysis overcomes this limitation by employing an analyzing function that is local both in time and frequency. The wavelet transform is a powerful tool for the study and analysis of transient phenomena in electric power systems.Furthermore, in this work the wavelet transform has been implemented with a neural network which allows us to incorporate it within the whole network for pattern recognition. Both neural networks along with the information supplied by the wavelets, have made it possible to increase the speed and reliability of the relay, especially during the fault inception.Also, one of our aims was to carry out the practical implementation of an electronic board in order to test the performance of the neural relay. To do this, it was necessary to use equipment to carry out the laboratory test, by emulating the same or a similar system employed while designing and training the relay.Prof. R. K. Aggarwal, in the Electrical department in the University of Bath expertise in the application of signal processing and Artificial Intelligence technology for the development of novel intelligent relays for Power Systems, both for transmission and distribution systems. Their experience is not only in the CAD work but also in the design and engineering of proto-type hardware. To do this the RTDS (Real Time Digital Simulator) system was employed. The obtained results were fully satisfactory.These successful tests results encourage investment in neural networks in high speed protec-tion for high voltage transmission lines. The response time is even less than 1.8 ms for faults close to the relay, which has a good performance in front of noise, faulty data and sudden change of load.
10

Aportaciones a los acondicionadores activos de corriente en derivación para redes trifásicas de cuatro hilos

Rodríguez Cortés, Pedro 24 February 2005 (has links)
Este trabajo se dedica a la búsqueda de soluciones que permitan mejorar el comportamiento de los filtros activos de potencia en derivación que trabajan en redes trifásicas de cuatro hilos, incluso cuando se den condiciones adversas en las tensiones suministradas por la red, o en las corrientes solicitadas por la carga.El cálculo de la potencia instantánea en condiciones no sinusoidales constituye la base fundamental del análisis de los acondicionadores de potencia. A día de hoy no existe una teoría universal que unifique el cálculo de las componentes de la potencia instantánea y de la corriente. En este trabajo se realiza un estudio detallado en este campo, evidenciando la relación entre las diferente teorías convencionales, y proponiendo una nueva formulación que ofrece un mayor significado físico a las componentes de potencia y de corriente resultantes.El conocimiento de la componente de secuencia positiva y frecuencia fundamental de la tensión de red es una cuestión de vital importancia en la sincronización de los sistemas electrónicos de potencia que trabajan conectados a ésta. Este trabajo presenta un nuevo sistema de detección que obtiene, de forma rápida y precisa, la componente fundamental de secuencia positiva de la tensión de red, incluso cuando dicha tensión se encuentre fuertemente distorsionada y desequilibrada. El convertidor estático conocido como inversor constituye el núcleo de un filtro activo de potencia. Las prestaciones finales del sistema de filtrado vienen condicionadas en gran medida por la tecnología empleada en este inversor, por su topología, por la técnica de modulación implementada, y por las características del sistema de control que regula las variables de salida del mismo. Este trabajo propone una topología de inversor alternativa, aplicable en acondicionadores activos que trabajan en sistemas trifásicos de cuatro hilos, que permite un control sencillo, y que elimina los problemas que presentan otras topologías cuando inyectan corrientes de secuencia homopolar en la red. Así mismo, se propone un nuevo enfoque en la modulación vectorial de los inversores en puente completo, de tres y cuatro ramas. La técnica propuesta aporta mayor significado físico en la síntesis de las tensiones de salida del inversor, y permite obtener un algoritmo de modulación sumamente eficiente que puede ser implementado en un procesador de bajo coste.Finalmente, este trabajo ofrece un nuevo punto de vista en el cálculo de las corrientes de referencia del filtro activo de potencia. Un análisis de las solicitaciones de potencia que se realizan sobre el filtro activo cuando trabaja bajo condiciones genéricas de tensión de red y corriente de carga, permite diseñar un sistema de control que emplea un enfoque energético en el cálculo las referencias de corriente del mismo. Este control energético aumenta la robustez del filtro activo de potencia cuando se producen súbitas variaciones en las condiciones del entorno. / The aim of this work is to find some solutions in order to improve the behavior of the shunt active power filters in three-phase four-wire power systems, even if adverse conditions are present in the utility voltages or in the load currents.The calculation of the instantaneous electrical power under non-sinusoidal conditions is the basis in the analysis of power conditioners. At present, there is not a universal theory that unifies the calculation of the instantaneous power and current components. In this work, a detailed study on this field is conducted, showing the relationship between the different conventional theories, and proposing a new formulation, which offers a higher physical meaning for the calculated power and current components than if previous theories are used.The knowledge about the positive-sequence fundamental-frequency component of the utility voltage is a crucial matter in the synchronization of power electronics systems interfaced to the utility. This work presents a new detection system, which obtains, quickly and accurately, the positive-sequence fundamental-frequency utility voltage, even if utility voltage is severely distorted and unbalanced.A static converter, known as inverter, is the core of an active power filter. The potentialities of the filtering system are greatly conditioned by the technology of this inverter, by its topology, by the modulation technique, and by the characteristics of the control system that regulates the output variables of the inverter. This work proposes an alternative inverter topology suitable for active conditioners working in three-phase four-wire systems, which allows a simple control and cancels the problems shown by other topologies when zero-sequence currents are injected in the utility. Also, a new approach on the space vector modulation of three- and four-leg full-bridge inverters is proposed. The proposed technique offers a higher physical meaning than previous techniques in the synthesis of the inverter output voltage, and gives rise to a very efficient algorithm, which can be implemented in a low-cost processor.Finally, this work offers a new standpoint in the calculation of the reference currents of the active power filter. An analysis of the instantaneous power flow when the active power filter is working under generic utility voltage and load current, gives rise to a new control system, which employs an energy approach in the reference currents calculation. This energy control increases the robustness of the active power filter when sudden variations appear in the environment conditions.