• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Mapping of the electrical activity of human atria. Multiscale modelling and simulations

Martínez Mateu, Laura 25 June 2018 (has links)
La fibrilación auricular es una de las arritmias cardíacas más comunes observadas en la práctica clínica. Por lo tanto, es de vital importancia desarrollar nuevas tecnologías destinadas a diagnosticar y acabar con este tipo de arritmia, para mejorar la calidad de vida de los pacientes y reducir los costes de los sistemas nacionales de salud. En los últimos años ha aumentado el uso de las nuevas técnicas de mapeo auricular, basadas en sistemas multi-electrodo para mapear la actividad eléctrica en humanos. Dichas técnicas permiten localizar y ablacionar los impulsores de la fibrilación auricular, como son las fuentes focales o los rotores. Sin embargo, todavía existe incertidumbre sobre su precisión y los procedimientos experimentales para su análisis están limitados debido a su carácter invasivo. Por lo tanto, las simulaciones computacionales son una herramienta muy útil para superar estas limitaciones, al permitir reproducir con fidelidad las observaciones experimentales, dividir el problema bajo estudio en sub-estudios más simples, y realizar investigaciones preliminares imposibles de llevar a cabo en el práctica clínica. Esta tesis doctoral se centra en el análisis de la precisión de los sistemas de mapeo multi-electrodo a través de modelos y simulaciones computacionales. Para ello, desarrollamos modelos realistas multi-escala con el objetivo de simular actividad eléctrica auricular reentrante, en primer lugar en una lámina de tejido auricular, y en segundo lugar en las aurículas completas. Posteriormente, analizamos los efectos de las configuraciones geométricas multi-electrodo en la precisión de la localización de los rotores, mediante el uso de agrupaciones multi-electrodo con distancias inter-electrodo equidistantes, así como a través de catéteres de tipo basket con distancias inter-electrodo no equidistantes. Después de calcular los electrogramas unipolares intracavitarios, realizamos mapas de fase, detecciones de singularidad de fase para rastrear los rotores, y mapas de frecuencia dominantes. Finalmente, descubrimos que la precisión de los sistemas de mapeo multi-electrodo depende de su posición dentro de la cavidad auricular, de la distancia entre los electrodos y el tejido, de la distancia inter-electrodo, y de la contribución de las fuentes de campo lejano. Además, como consecuencia de estos factores que pueden afectar a la precisión de los sistemas de mapeo multi-electrodo, observamos la aparición de rotores falsos que podrían contribuir al fracaso de los procesos de ablación de la fibrilación auricular. / Atrial fibrillation is one of the most common cardiac arrhythmias seen in clinical practice. Therefore, it is of vital importance to develop new technologies aimed at diagnosing and terminating this kind of arrhythmia, to improve the quality of life of patients and to reduce costs to national health systems. In the last years, new atrial mapping techniques based on multi-electrode systems are increasingly being used to map the atrial electrical activity in humans and localise and target atrial fibrillation drivers in the form of focal sources or rotors. However, significant concerns remain about their accuracy and experimental approaches to analyse them are limited due to their invasive character. Therefore, computer simulations are a helpful tool to overcome these limitations since they can reproduce with fidelity experimental observations, permit to split the problem to treat into more simple substudies, and allow the possibility of performing preliminary investigations impossible to carry out in the clinical practice. This PhD thesis is focused on the analysis for accuracy of the multielectrode mapping systems through computational models and simulations. For this purpose, we developed realistic multiscale models in order to simulate atrial electrical reentrant activity, first in a sheet of atrial tissue and, then, in the whole atria. Then, we analysed the effects of the multi-electrode geometrical configurations on the accuracy of localizing rotors, by using multi-electrode arrays with equidistant inter-electrode distances, as well as multi-electrode basket catheters with non-equidistant inter-electrode distances. After computing the intracavitary unipolar electrograms, we performed phase maps, phase singularity detections to track rotors, and dominant frequency maps. We finally found out that the accuracy of multi-electrode mapping systems depends on their position inside the atrial cavity, the electrode-to-tissue distance, the inter-electrode distance, and the contribution of far field sources. Furthermore, as a consequence of these factors, false rotors might appear and could contribute to failure of atrial fibrillation ablation procedures. / La fibril·lació auricular és una de les arítmies cardíaques més comuns observades en la pràctica clínica. Per tant, és de vital importància desenvolupar noves tecnologies destinades a diagnosticar i acabar amb aquest tipus d'arítmia, per tal de millorar la qualitat de vida dels pacients i reduir els costos dels sistemes nacionals de salut. En els últims anys, ha augmentat l'ús de les noves tècniques de mapeig auricular, basades en sistemes multielèctrode per a mapejar l'activitat elèctrica auricular en humans. Aquestes tècniques permeten localitzar i ablacionar els impulsors de la fibril·lació auricular, com són les fonts focals o els rotors. No obstant això, encara hi ha incertesa sobre la seua precisió i els procediments experimentals per al seu anàlisi estan limitats a causa del seu caràcter invasiu. Per tant, les simulacions computacionals són una eina molt útil per a superar aquestes limitacions, en permetre reproduir amb fidelitat les observacions experimentals, dividir el problema sota estudi en subestudis més simples, i realitzar investigacions preliminars impossibles de dur a terme en el pràctica clínica. Aquesta tesi doctoral es centra en l'anàlisi de la precisió del sistemes de mapeig multielèctrode mitjançant els models i les simulacions computacionals. Per a això, desenvolupàrem models realistes multiescala per tal de simular activitat elèctrica auricular reentrant, en primer lloc en una làmina de teixit auricular, i en segon lloc a les aurícules completes. Posteriorment, analitzàrem els efectes de les configuracions geomètriques multielèctrode en la precisió de la localització dels rotors, mitjançant l'ús d'agrupacions multielèctrode amb distàncies interelèctrode equidistants, així com catèters de tipus basket amb distàncies interelèctrode no equidistants. Després de calcular els electrogrames unipolars intracavitaris, vam realitzar mapes de fase, deteccions de singularitat de fase per a rastrejar els rotors, i mapes de freqüència dominants. Finalment, vam descobrir que la precisió dels sistemes de mapeig multielèctrode depèn de la seua posició dins de la cavitat auricular, de la distància entre els elèctrodes i el teixit, de la distància interelèctrode, i de la contribució de les fonts de camp llunyà. A més, com a conseqüència d'aquests factors, es va observar l'aparició de rotors falsos que podrien contribuir al fracàs de l'ablació de la fibril·lació auricular. / Martínez Mateu, L. (2018). Mapping of the electrical activity of human atria. Multiscale modelling and simulations [Tesis doctoral no publicada]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/104604 / TESIS

Page generated in 0.0815 seconds