• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Output Power Calibration Methods for an EGPRS Mobile Platform / Metoder för uteffektskalibrering av en EGPRS mobilplattform

Eriksson, Hans January 2003 (has links)
<p>This thesis deals with output power calibration of a mobile platform that supports EGPRS.Two different topics are examined. First some different measurement methods are compared concerning cost efficiency, accuracy, and speed and later measurements are carried out on a mobile platform. </p><p>The output power from the mobile platform is controlled by three parameters and the influence on the output power when varying those parameters is investigated and presented. Furthermore, two methods of improving the speed of the calibration are presented. </p><p>The first one aims to decrease the number of bursts to average over as much as possible. The conclusion is that 10-20 bursts are enough for GMSK modulation and about five bursts for 8PSK modulation. The purpose of the second investigation is to examine the possibility to measure the output power in one modulation and frequency band, and then calculate the output power in the other bands. The conclusion in this case is that, based on the units investigated, it is possible for some values of the parameters and in some frequency bands. However, more units need to be included in the basic data for decision-making and it is possible that the hardware variation is too large.</p>
2

Output Power Calibration Methods for an EGPRS Mobile Platform / Metoder för uteffektskalibrering av en EGPRS mobilplattform

Eriksson, Hans January 2003 (has links)
This thesis deals with output power calibration of a mobile platform that supports EGPRS.Two different topics are examined. First some different measurement methods are compared concerning cost efficiency, accuracy, and speed and later measurements are carried out on a mobile platform. The output power from the mobile platform is controlled by three parameters and the influence on the output power when varying those parameters is investigated and presented. Furthermore, two methods of improving the speed of the calibration are presented. The first one aims to decrease the number of bursts to average over as much as possible. The conclusion is that 10-20 bursts are enough for GMSK modulation and about five bursts for 8PSK modulation. The purpose of the second investigation is to examine the possibility to measure the output power in one modulation and frequency band, and then calculate the output power in the other bands. The conclusion in this case is that, based on the units investigated, it is possible for some values of the parameters and in some frequency bands. However, more units need to be included in the basic data for decision-making and it is possible that the hardware variation is too large.

Page generated in 0.0428 seconds