• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Επιπλοκές της χρήσης του ενδοαορτικού ασκού σε κλινικές και πειραματικές εφαρμογές

Παρίσης, Χαράλαμπος Δ. 19 December 2008 (has links)
Στην υπό μελέτη διατριβή διερευνήθηκε μια σειρά υποθέσεων που οδήγησαν: 1) Στη ανεύρεση μαθηματικών μοντέλων που δύνανται να υπολογίζουν το μήκος σημαντικών ανατομικών μεγεθών στη κατιούσα αορτή και κατ επέκταση να προσφέρουν βοήθεια στη επιλογή του ιδανικού μεγέθους ασκού ανά μεμονωμένο ασθενή. Δείξαμε ότι αυτά τα μοντέλα έχουν αυξημένο βαθμό προβλεπτικής αξίας. Περαιτέρω τα συγκρίναμε με τον κλασικό τρόπο επιλογής του ιδανικού μεγέθους και ευρέθησαν ανώτερα. 2)Στη δημιουργία και εξέταση των συνθηκών όπου συμβαίνει η τραυματική διαταραχή του έσω χιτώνα της κατιούσης αορτής κατά την διάρκεια της λειτουργίας του ενδοαορτικου ασκού. Η κίνηση του ασκού εντός του αορτικού αυλού είναι πολύπλοκη. Είναι σημαντική η παρατηρούμενη επαναλαμβανόμενη «επίδραση κρούσης δικην μαστιγίου» (whipping effect) του καθετήρα του ασκού στο οπίσθιο- πλάγιο αορτικό τοίχωμα. Αυτή η κίνηση φάνηκε να ενισχύεται κατά την παρατεταμένη φάση της σύμπτυξης του ασκού όταν ο ρυθμός λειτουργίας του IABP είναι 1:3. Κάτω από τέτοιες συνθήκες σημειώθηκε επιδείνωση του «score αορτικού τραύματος» που συνηγορεί υπέρ της αποφυγής του απογαλακτισμού με σταδιακή ελάττωση του ρυθμού λειτουργίας του ασκού (mode). Η επαναλαμβανόμενη κυκλική κίνηση του ενδοαορτικου ασκού επιβεβαιώθηκε κατά την διάρκεια της λειτουργίας του σε πτωματικές αθηρωματικες αορτές. Καταγραφή διαταραχών και αποκόλλησης ( fissuring) πλακών αποδόθηκε στο κύμα πίεσης που δημιουργήθηκε από την κίνηση του ασκού και λιγότερο σε άμεσο τραυματισμό. 3) Στη κλινική εξέταση των επιπλοκών καρδιοχειρουργικών ασθενών που χρειάσθηκαν θεραπεία με ενδοαορτικο ασκό, όπου βρέθηκαν συγκεκριμένα γκρουπ αυξημένου ρίσκου. Ασθενείς όπου η χρήση του ασκού χρησιμοποιηθηκε μετεγχειρητικά καθώς και ασθενείς όπου χρειάστηκαν θεραπεία με IABP μετά από αντικατάσταση βαλβίδας (ιδιαίτερα μιτροειδούς βαλβίδας) παρουσίασαν υψηλή μετεγχειρητική θνητότητα. Οι ακόλουθες μεταβλητές εμφανίσθηκαν ως παράγοντες κινδύνου αυξημένης θνησιμότητας: Θηλυκό γένος, κάπνισμα, αυξημένη προ-εγχειρητική κρεατινινη, ισχαιμικός χρόνος>80min και εισαγωγή του ασκού την μετεγχειρητική περίοδο. Με χρήση παλίνδρομης ανάλυσης, βρέθηκε ότι ιστορικό περιφερικής αγγειοπαθειας, και κλάσμα εξώθησης κάτω από 30% αποτελούν παράγοντας κινδύνου για την ανάπτυξη αγγειακών επιπλοκών. Επιπρόσθετα με την χρήση προδρομικής τυχαιοποιημένης μελέτης φάνηκε ότι απογαλακτισμός μέσω μείωσης του όγκου πλήρωσης του ασκού απετέλεσε προφυλακτικό παράγοντα για την ανάπτυξη αγγειακών επιπλοκών. Συμπερασματικά από αυτή την εργασία απορρέουν προτάσεις που πιθανώς θα επηρεάσουν την κλινική πράξη. Συγκεκριμένα προτίθεται ένας τρόπος επιλογής του ιδανικού μεγέθους ασκού που δύναται να οδηγήσει σε αποφυγή χρησιμοποίησης μεγάλων ασκών σε μικρόσωμες γυναίκες με αθηρωματικες αορτές με αποτέλεσμα περαιτέρω ελάττωση των αγγειακών επιπλοκών. Επιπρόσθετα έχοντας μελετήσει τον τρόπο κίνησης του ασκού κάτω από διαφορετικά αιμοδυναμικα σενάρια οδηγούμεθα στο συμπέρασμα ότι ο «απογαλακτισμός» πρέπει να γίνεται με ελάττωση του όγκου του ασκού (augmentation). Δείξαμε ότι αυτός ο τρόπος «απογαλακτισμού» έχει τη τάση να οδηγεί σε λιγότερες εμβολικες επιπλοκές. Τέλος έγινε ταυτοποίηση συγκεκριμένων γκρουπ ασθενών όπου αλλαγή πρακτικής όσο αναφορά την πιο πρώιμη χρησιμοποίηση του ασκού η την αλλαγή στον τρόπο απογαλακτισμού από αυτό μπορεί δυνητικά να οδηγήσει σε μείωση της θνητότητας και νοσηρότητας. / IAB size selection is based on patients height with the known risks of under or over sizing, although size selection should rely on individual hemodynamics & measurements of the length & diameter of the aorta from the left subclavian artery to the celiac axis. The first part of this project is a pilot study whereby an attempt was made, in order to predict thoracic aortic dimensions from easily obtainable external anatomical landmarks. That would potentially lead to an optimal selection of balloon sizes for an individual patient and thus reducing adverse effects of its use. The second part of the project is an experimental Angioscopic and Pathological study that set off to investigate in a mock pig circulation model, whether weaning by mode or by augmentation produces more aortic intimal trauma. The third part of this work, studied the interaction between the intraaortic balloon catheter and the human atherosclerotic aorta. With the use of an artificial circulation we obtained direct visualisation of the dynamic action of the balloon catheter within the cadaveric human aorta. Sequelae of traumatic atherosclerotic plaque rapture due to the balloon action was observed. The last study was a clinical outcome analysis with an interest in complications in a cohort of patients requiring treatment with IABP in a single Cardiothoracic Unit over a five year period. During the initial part of the project, measurements were carried out from a series of 40 cadavers during autopsy. Internal Aortic dimensions and also external somatometric distances of the thoracic cage were obtained. Using multiple regression analysis a model was devised in order to predict aortic lengths. Being able to calculate internal aortic lengths, one could be lead to a better intraaortic balloon sizing. During the second part of the study an artificial pulsatile pump was used and an intact porcine aorta was incorporated into the circuit with the inflow at the aortic valve and the outflow at the right common iliac artery. Direct angioscopic images of the interior of the aorta were obtained. Keeping steady hemodynamic conditions, an “aortic impact score” was calculated taking into account angioscopic observational variables and biopsies of the aorta at 30min, 6hours and 12 hours following counterpulsation at 1:1, 1:2 ,1:3 Versus 1:1 and 75%, 50% and 25% augmentation. The previous model was extrapolated in to the third study whereby an artificial circulation was constructed using of PVC tubing, a filter and a roller pump. A series of 5 intact cadaveric human aortas were then individually studied by placing each in series within the circuit. A balloon catheter was advanced via the left common iliac artery into the descending aorta under direct angioscopic vision. Balloon pumping was then commenced. The circuit was perfused with Normal saline at a flow rate of 3L/minute. Pump actions of 1:1 and 1:2 were simulated. A microporous filter was incorporated into the system in order to collect embolic material during balloon action. Each aorta at the end of the experiment was subjected to histological examination. During the last study data were prospectively collected within a 5 year period from a single Cardiothoracic Unit. 2697 adult patients underwent cardiac surgery, out of which 136patients (5%) required IABP. Those patients were studied in terms of balloon associated complications. We create a model of optimal balloon sizing with a high prediction value. The performance of the model was tested against the current quidelines in a cross validation way and was found to be superior. Together with height, somatometric measurements of thoracic cage could lead to more optimal IAB size selection. During the angioscopic observational studies with porcine and also cadaveric aortas the movement of the balloon catheter in relation to the aorta was observed. The balloon catheter moves relative to the wall of the aorta during inflation and deflation. Contact between the balloon and the aorta only occurs during deflation. Side branches of the aorta are not occluded by the catheter. Plaque disruption and embolus formation appear to result from pressure wave action rather than direct contact with the balloon. By calculating the aortic impact score it appears that weaning by mode produces more aortic intimal trauma. 1:3 mode produces marked intimal disruption that worsens with time. Lastly during the clinical study of patients requiring treatment with an IABP we detected significant early mortality and morbidity associated with IABP, however intermediate follow up reveals favourable outcome.

Page generated in 0.0164 seconds