• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 7
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Post-buckling of truss-lattice shear panels

Williams, Ashley Philip January 2007 (has links)
No description available.
2

The application of finite element analysis to the design of embedded retaining walls

Woods, Richard Ian January 2003 (has links)
No description available.
3

The performance of double skin facades in office building refurbishment in hot arid areas

Hamza, Neveen Ahmed January 2004 (has links)
The facade's configuration in hot arid areas is predicted to be responsible for up to 40% of the building's cooling loads. The increasing reliance of public buildings in Cairo on air conditioning systems indicates the failing role of the building envelope to perform its function as a moderator leading to an alarming increase in electricity consumption. Office buildings in Cairo consume 5-7% of the total national energy consumption. The need to reduce energy consumption in this sector targets benefits of reductions of electricity bills to building owners as well as reducing C02 emissions from the built environment due to increasing electricity generation. The lack of maintenance funds left the office building facades in a deteriorated state. This deterioration of image led to abandonment of buildings and loss of economic revenue. Double skin facades were investigated as a novel facade refurbishment option, targeting a multi criteria framework for facade refurbishment set in this thesis. To achieve the aim of the thesis, different facade technologies were simulated using a dynamic software (APACHE v.4.3.1) to understand their thermal performance. Quantitative results of simulations were parametrically examined to identify benchmark options for facade refurbishment to reduce building total cooling loads. Simulations results indicated up to 40% reductions in total cooling loads if a double skin facade with an outer reflective surface is used. Information generated from the simulation of single and double skin facade configurations were inducted into qualitative theories predicting human comfort aspects within the workplace. Three qualitative criteria underpinning the psychological comfort of occupants and its impact on productivity are set for balancing energy saving measures through facade refurbishment. These criteria are: the need for a view out, day light availability for non-task performances, and perceived control over the facade in work places.
4

Impact resistance of masonry walls : materials characterisation & numerical modelling

Burnett, Steven January 2003 (has links)
No description available.
5

Seismic behaviour of reinforced concrete walls with low shear ratio

Lopes, Mario Manuel Paisana dos Santos January 1991 (has links)
No description available.
6

Ενίσχυση φέρουσας τοιχοποιίας για εντός επιπέδου φόρτιση με σύνθετα υλικά ανόργανης μήτρας και με ράβδους σύνθετων υλικών σε εγκοπές

Κάρλος, Κυριάκος 14 May 2007 (has links)
Μια από τις πολλές δομικές εφαρμογές των συνθέτων υλικών, είτε αυτά έχουν την μορφή ινοπλισμένων πολυμερών είτε την μορφή ινοπλισμένων κονιαμάτων, είναι και η ενίσχυση τοιχοποιίας, φέρουσας ή μη. Τα σύνθετα υλικά είναι δυνατό να δώσουν λύση σε προβλήματα στατικής επάρκειας και αναβάθμιση στάθμης επιτελεστικότητας κτηρίων σύμφωνα με τους Ευρωκώδικες. Ο στόχος της συγκεκριμένης μεταπτυχιακής διατριβής είναι: i. Να μελετηθούν οι τρόποι με τους οποίους είναι δυνατόν να ενισχυθεί μια τοιχοποιία από οπτοπλινθοδομή και να πραγματοποιηθούν πειραματικές δοκιμές, (για να καταστεί με αυτό τον τρόπο δυνατή η σύγκριση των θεωρητικών με τα πειραματικά δεδομένα). ii. Η κατασκευή αντιπροσωπευτικών δοκιμίων που να εξετάζουν και να απεικονίζουν την πλειονότητα των δομημάτων και τελικά η πειραματική επεξεργασία τους. iii. Η επιλογή των κατάλληλων υλικών με τα οποία είναι δυνατή η αποτελεσματική και πρακτική η ενίσχυση της τοιχοποιίας. iv. Η μελέτη του τρόπου με τον οποίο αλληλεμπλέκονται τα σύνθετα υλικά με την τοιχοποιία και η τελική αστοχία της τελευταίας, με στόχο την απόκτηση μεγαλύτερης αντοχής και πλαστιμότητας. v. Η σύγκριση των τρόπων ενίσχυσης με ανόργανη (τσιμεντοκονίαμα) και οργανική (εποξειδική ρητίνη) μήτρα και ανθρακονήματα. vi. Η εφαρμογή και εκτίμηση της αποτελεσματικότητας της ενίσχυσης με ράβδους ινών άνθρακα σε βαθιά αρμολογημένο τοίχο με την βοήθεια εποξειδικού τσιμεντοκονιάματος. vii. Η εκτίμηση κατά πόσο με την βοήθεια ενίσχυσης φέρουσας οπτοπλινθοδομής με σύνθετα υλικά είναι δυνατή η κάλυψη των σύγχρονων αντισεισμικών απαιτήσεων. / One of the many uses of composite materials, either in the form of fiber reinforced plastics "FRP" either in the form of fiber reinforced mortars, is the structural reinforcement of masonry. The composite materials are capable to provide a structural upgrade to a building so that it meats the contemporary eurocode demands. The goal of this master thesis is: 1. to study the possible ways of brick masonry reinforcement and perform experimental studies (so that it become possible to compare the theoretical with the experimental data) 2. the construction of representative experimental specimens that examine end picture the majority of civil masonry constructions end finally the experimental elaboration of these specimens. 3. The selection of the suitable material with witch it is possible end practical the reinforcement of the masonry. 4. The study of the ways that composite materials collaborate with the brick masonry up to the point of destruction end finding a way that the reinforced specimens would have more strength end ductility than the unreinforced ones. 5. The comparison end effectiveness of the specimens reinforced with inorganic matrix (cement mortar) versus the ones reinforced with organic matrix (epoxy resin) end carbon fibers. 6. The application end estimation of the effectiveness of carbon fiber bar reinforcement that is applied near the surface in the bed joints of the masonry specimens with the help of epoxy resin cement mortar. 7. To estimate if it is possible with the help of composite materials to reinforce masonry so that it meats contemporary antiseismic construction demands.
7

Caractérisation, analyse et modélisation des échanges énergétiques entre un mur végétalisé intensif et son environnement / Characterization, analysis and modelization of energy exchanges between a green wall and its environment

Kenaï, Mohamed Amine 20 September 2016 (has links)
Ce travail de thèse vise à comprendre et analyser les échanges thermiques qui ont lieu entre un bâtiment et son environnement en présence de parois végétalisées « intensives ». Nous présentons dans ce manuscrit, une démarche numérique et expérimentale sur l’évaluation de l’incidence thermique de ces Murs Végétalisés (MV). Une plateforme constituée de trois prototypes identiques (3 mini-laboratoires thermiques) sous conditions climatiques réelles a été conçue et instrumentée. Dans un premier temps, deux écrans permettant une variation rapide et graduelle des taux de couvertures de 10 à 100% ont été ajoutés devant les prototypes. Ainsi, plusieurs séries de mesures ont été effectuées et des réductions significatives au niveau des températures et des flux de chaleur ont été enregistrées et interprétées. Cette démarche expérimentale avait pour premier objectif de mettre en oeuvre une occultation artificielle et donc maîtrisée. Un premier modèle a été développé sur la base de l’écriture des équations de bilan des échanges thermiques entre la paroi à occultation variable et son environnement climatique. Ce modèle confronté aux résultats fournis par l’expérimentation apermis de valider les approches théoriques au niveau des transferts radiatifs et convectifs. Dans un deuxième temps, le premier modèle qui a été développé dans ce travail a été adapté au cas d’une occultation « réelle » par de la végétation (lierre ou vigne vierge) puis validé expérimentalement. Il a été finalement implémenté dans un code de simulation thermique dynamique de bâtiment (TRNSYS), et ainsi l’incidence thermique des murs végétalisés simples (intensifs) a pu être évaluée à l’échelle réelle d’un bâtiment. Les résultats de simulations pour un climat tempéré montrent que la présence des plantes à feuilles persistantes a un impact négatif sur la demande énergétique hivernale. A l’inverse, en période estivale, les résultats montrent que les murs végétalisés ont un intérêt au niveau de la limitation des surchauffes. Leur présence réduit alors notablement la consommation énergétique nécessaire pour « climatiser » le bâtiment et améliore ainsi le confort thermique intérieur. / This PhD thesis aims to understand and analyse the heat exchanges that occur between a building and its environment in the presence of intensive vegetated walls. In this manuscript, a numerical and experimental approach to evaluate the thermal impact of green walls is presented. A platform composed of three identical prototypes (3 thermal mini-laboratories) under real weather conditions has been designed and instrumented. As a first step, two screens permitting a rapid and gradual variation of coverage rate from 10 to 100% were added to the prototypes. Thus, several series of measurements were performed and significant reductions in temperature and heat flow were recorded and interpreted. The primary objective of this experimental approach was to implement an artificial shading and thus controlled. A first model was developed based on the writing of heat exchanges energy balance equations between the wall with variable coverage rate and its climatic environment. This model confronted to the experimental results allowed the validation of the theoreticalapproaches at the level of radiative and convective heat transfer. Secondly, the first model that was developed in this work has been adapted to the case of a "real" occultation by vegetation (Ivy or Virginia creeper) then validated experimentally.It was finally implemented in a dynamic thermal simulation code (TRNSYS), and thus the thermal impact of green walls were evaluated at the real scale of a building. Simulation results in a temperate climate show that the presence of evergreen plants has a negative impact on winter energy demand. Conversely, in summer, the results show that green walls have an interest in limiting overheating. Their presence significantly reduces energy consumption needed to cool the building and improves the indoor thermal comfort.

Page generated in 0.0448 seconds