• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 36
  • 9
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

The development of a methodology for a tool for rapid assessment of indoor environment quality in office buildings in the UK

Ncube, Matiwaza January 2012 (has links)
This thesis describes a methodology for the development of a novel tool for rapid assessment of Indoor Environment Quality (IEQ) in office buildings in the UK. The tool uses design, measured, calculated and surveyed data as input for IEQ calculations. The development of such a tool has become a necessity especially in the developed world where legally binding targets for Green House Gas (GHG) emissions have been agreed and where buildings are required by law to display energy performance certification. The novelty of this tool is that it addresses the need to present an indoor environment performance rating that can be presented alongside energy performance certification since the energy performance of office buildings depends significantly on the criteria used for the indoor environment. The tool, called the IEQAT (Indoor Environment Quality Assessment Tool), is based on the IEQ model which was developed from literature review. The IEQ model is based on the IEQ index which was derived from contributing factors or sub indices that include Thermal Comfort, Indoor Air quality (IAQ), Acoustic Comfort and Lighting. The model was tested by studying the responses of occupants of three office buildings in the UK. Their subjective responses which were collected via a questionnaire were compared against model simulation results which were calculated using physical measurements of IEQ variables such as air temperature, illuminance (lux), background noise levels (dBA), relative humidity, carbon dioxide concentration (ppm), and air velocity. By fitting a multivariate regression model to questionnaire data, a weighted ranking of parameters affecting IEQ was produced and new provisional weightings for the IEQ model, which is more relevant to the UK situation, were derived.
22

Thermal comfort and occupant behaviour in office buildings in south-east China

Wu, Jindong January 2015 (has links)
Natural ventilation is a passive cooling method that has significant potential to reduce building energy consumption and to positively contribute to indoor environmental conditions. Because the window is an important element in naturally ventilated buildings, it can be used to adjust indoor air flow. However, lack of knowledge about occupants‘ window control behaviour and how this relates to different window typology would result in discrepancy between actual and proposed building performance. And also, limit the potential of natural ventilation in the building. This thesis explores the relationship between indoor air velocity, occupants‘ window control behaviour and window design. This study is based on field measurement and occupant comfort survey in four office buildings in a hot and humid climate in South-east China. The field study was carried in September and October of 2012. The indoor and outdoor thermal conditions, indoor air flow speed, window state and effective opening area were monitored. Occupant thermal comfort questionnaires were given to participants four times a day to record their comfort perceptions in the office. The field study gives new insights into the correlation between indoor air speed, occupants‘ window control behaviour and window design. For the research 14400 set of indoor and outdoor temperature and relative humidity data, 174560 indoor air velocity records and 1344 copies of questionnaires were collected. The results of this study defined comfort zone for this climate which is consistent with Givoni‘s comfort zone for a hot and humid climate. The indoor air flow path is identified by measuring the indoor air velocity across different parts of the office and related window opening combinations. Besides, the effective opening area is reduced with decreased indoor air temperature when the indoor air temperature is lower than 25°c. None of the windows is closed when the indoor air temperature is higher than 28°c. During the working hours, the changing of effective opening is related to the air velocity across the desk surface. And measured maximum indoor air velocity measured around the occupant is 1.8m/s which did not result in occupants‘ window changing behaviour to adjust for comfort. In conclusion, this study proved that occupants who live in hot and humid climate can accept higher humidity level. If the air velocity can be avoided across the occupant‘s working surface, then a higher indoor air velocity is still accepted by occupant as within their comfort threshold. So, there are great potentials for occupant to extend their comfort threshold and adapt to the local climate. Besides, window opening type and position has a significant impact on indoor air velocity and pattern. It would also influence convective cooling affect and occupant thermal comfort. This is evident from the indoor air velocity measurement results and the occupant comfort survey results. In addition, accessibility is important to window design. In the naturally ventilated office building, if occupants find it difficult to operate the window, this will have an influence on the natural ventilation potential in the building and cause the occupant discomfort. Thus, the findings of this study will help architects and engineers to design naturally ventilated office buildings in South-east China.
23

A heat pipe and porous ceramic based sub wet-bulb temperature evaporative cooler : a theoretical and experimental study

Amer, Omar January 2017 (has links)
Worldwide energy demand in buildings represents about 40-50% of the total energy consumption. In hot climates, such as Middle East and North Africa (MENA) countries, about 30% of the national power demand is used for HVAC applications in buildings. This has led to escalation in power demand in buildings for indoor air-cooling and high energy bills. This is exacerbated further by the widespread adoption of energy intensive and commercially dominant vapour compression air conditioning systems as the technology of choice. This research aims to address the potential of novel designs of evaporative cooling systems for space cooling and thermal comfort in buildings with reduced water and energy consumption, and low environmental impact as an alternative to vapour compression where climatically is suitable. High water consumption rates and low cooling effectiveness are some of the issues affecting the performance of existing Indirect Evaporative Coolers (IEC). A new configuration of IEC combining heat pipe heat exchanger and porous ceramic tubes is investigated in this work. The proposed cooler configuration is based on the concept of regenerative IEC system, this system incorporates heat pipes as passive heat transfer elements and porous ceramic tubes as wet medium mounted on the condenser side of the exchanger. The design of the cooler was carried out with consideration for size of the airflows channels, heat pipes for heat transfer, and porous ceramic tubes properties for water evaporation. A mathematical formulation of heat and mass transfer equations was used to develop a computer model to design and optimise the cooling system. Furthermore, a test rig was built to test a laboratory scale cooling unit, evaluate the performance and validate the simulation. The simulation results reveal that the Wet-bulb (WB) effectiveness of the cooler ranged from 0.524 to 1.053, the COP ranged from 6.33 to 17.01, and water consumption rates of the cooler were around 0.875-1.55 (l/kWh) of cooling capacity. Whereas, the experimental performance parameters of the cooler show the WB effectiveness was in the range of 0.422-0.908 for all test conditions, the COP was 4.62-13.16, and water consumption rates varied 0.841-2.82 (l/kWh) of cooling capacity. A good agreement was obtained between the experiments data and numerical results, the maximum errors between measured and computed results was around 3.94% and 4.51% of supply air temperature and humidity, respectively, while the discrepancy was in the range of 8.67-12.90% of the WB effectiveness. The impact of operational and design parameters on the cooler performance was evaluated in a parametric study using the developed numerical model. It was found that increasing the inlet air temperature, decreasing the inlet air flow rate, and/or increasing the working-to-inlet air flow ratio, results in improving the effectiveness and supply air temperature. Whereas, increasing the inlet air wet-bulb temperature depression, increasing the inlet air flow rate, and/or minimising the working-to-inlet air flow ratio leads to enhancing the cooling output and COP of the cooler. Additionally, increasing the thickness and/or the radius of ceramic tube causes a decline of cooler thermal performance. Therefore, it is recommended to operate the cooler at inlet air velocity of 2-2.5 m⁄s, 50% flow ratio of working-to-inlet air, and inlet air relative humidity below 35% for best results of supply air temperature, WB effectiveness, and COP. Whereas, for desert climate conditions, it is recommended to increase the number of heat pipe rows to 20 to insure sufficient cooling effectivity and performance that meet comfort levels. Finally, a brief economic assessment of the cooler annual operational performance for a case study was carried out, this IEC system provide sufficient cooling effectiveness to the conditioned space with significantly low power consumption compared to traditional air conditioner with annual saving of 77.60% of operational costs, and also substantially contribute to minimise CO2 emissions by saving about 86% of electricity consumption.
24

Thermal performance analysis of a PCM combined solar chimney system for natural ventilation and heating/cooling

Li, Y. January 2013 (has links)
Solar chimney is an important passive design strategy to maximize solar gain to enhance buoyancy effect for achieving adequate air flow rate and a desired level of thermal comfort inside a building. Therefore, solar chimney has the potential advantages over mechanical ventilation systems in terms of energy requirement, economic and environmental benefits. The main aim of this project is to study the technical feasibility of a solar chimney incorporating latent heat storage (LHS) system for domestic heating and cooling applications. The research work carried out and reported in this thesis includes: the development of a detailed theoretical model to calculate the phase change material (PCM) mass for solar chimney under specific climatic condition, the development of a CFD model to optimise the channel depth and the inlet and outlet sizes for the solar chimney geometry, experimental and numerical investigations of the thermal performance of the proposed system using a prototype set-up, a parametric study on the proposed system to identify significant parameters that affect the system performance was carried out by using the verified numerical model. The numerical and experimental study showed that the numerical model has the ability to calculate the PCM mass for the proposed system for the given weather conditions. The optimum PCM should be selected on the basis of its melting temperature, rather than its other properties such as latent heat. The experimental work on the thermal performance of the proposed system has been carried out. The results indicated that the LHS based solar chimney is technically viable. The outlet air temperature and the air flow rate varied within a small range during phase change transition period which are important for a solar air heating system. A numerical model was developed to reproduce the experimental conditions in terms of closed mode and open mode. The model results were in a close agreement with the experimental results particularly the simulated results for the discharging process. With the verified model, a comprehensive parametric analysis intended to optimise the thermal performance of proposed the system was performed. The results analysed are quantified in terms of charging/discharging time of the PCM, temperature difference between outlet air and inlet air of the solar chimney, and mass flow rate of the chimney, which are the most important quantities of the proposed system.
25

Using large eddy simulation to model buoyancy-driven natural ventilation

Durrani, Faisal January 2013 (has links)
The use of Large Eddy Simulation (LES) for modelling air flows in buildings is a growing area of Computational Fluid Dynamics (CFD). Compared to traditional CFD techniques, LES provides a more detailed approach to modelling turbulence in air. This offers the potential for more accurate modelling of low energy natural ventilation which is notoriously difficult to model using traditional CFD. Currently, very little is known about the performance of LES for modelling natural ventilation, and its computational intensity makes its practical use on desk top computers prohibitive. The objective of this work was to apply LES to a variety of natural ventilation strategies and to compile guidelines for practitioners on its performance, including the trade-off between accuracy and cost.
26

Evaluating and enhancing design for natural ventilation in walk-up public housing blocks in the Egyptian desert climatic design region

Osman, Medhat January 2011 (has links)
This work is concerned with evaluating and studying the possibilities of enhancing natural ventilation performance and its use as a passive cooling strategy in walk-up public housing blocks within the Egyptian desert climatic region. This research attempts to maximize the benefits from the vast investments made in housing projects in Egypt through providing thermally comfortable housing prototypes that could use by contrast less energy for cooling purposes. This is considered essential in the light of the current concerns about energy all over the world. Egypt was devided to seven different climatic regions by the Egyptian organization for energy conservation and planning. The Egyptian desert climatic region, which was chosen as the research context, is the largest climatic region of Egypt. Most of the Egyptian new cities that accommodate the majority of the recent public housing projects are located within this desert climatic region that represents the typical hot arid climate characteristics. Nationally, the problem of the misuse of the housing prototyping was spotted. According to previous researchers, the same basic prototypical designs are being built all over the country without giving enough consideration to the actual effects of different climates and the diversity in the residents social needs. Regionally, within the Egyptian desert climatic region, the harsh climatic conditions rate the problem of achieving thermal comfort within these housing prototypes as the most urgent problem that needs to be examined in depth. A pilot study that used observation and monitoring methods was conducted in the New Al-Minya city (The representative city of the desert climatic design region) in order to closely investigate this problem and identify its dimensions. The results confirmed thermal discomfort conditions of the housing prototypes built there, especially during the hot summer period. The passive design strategies analysis of the climatic context indicated that night purge ventilation is the most effective passive strategy that could enhance thermal comfort. These results go along with the rule of natural ventilation in reducing the used energy for cooling and the actually massive national income spent on these housing prototypes encourage this work so to concentrate on natural ventilation. Different studies using multi-approaches research techniques were employed in order to achieve the main aim of the research. These techniques included; literature review, monitoring, questionnaire and computer simulation.A critical literature review was conducted including; the physical science of natural ventilation, its strategic design as well as the design measures that control natural ventilation and the airflow in; the macro, intermediate and micro design levels. The results of the investigations were discussed and interpreted in the light of this review. A representative case study was chosen for the study. The natural ventilation performance in the case study was quantitatively and qualitatively evaluated through conducting field objective and subjective assessment respectively. In evaluation study, the thermal performance of the case study under different ventilation scenarios was monitored, the airflow inside it was simulated using CFD (computational fluid dynamics) software “FloVent” and a sample of residents were questioned. This study identified many problems associated natural ventilation uses and indicated its poor performance within the case study. A number of design measures were formulated based on the literature review and considering the evaluation study results along with the research context nature. The proposed natural ventilation design measures were applied to the case studies and their effectiveness in terms of enhancing the natural ventilation performance was quantified using “FloVent”. Results reported that the proposed natural ventilation design measures could significantly enhance the natural ventilation performance inside the case study quantitatively and qualitatively. This in turn maximizes the potential of providing thermal comfort by using both natural ventilation strategies; comfort ventilation and night purge ventilation. However, all the applied measures could not achieve neither an acceptable airspeed at any of the case study spaces nor a good airflow circulation at some of its spaces. It can be concluded that the current design of the case study can not achieve quality airflow without the use of the mechanical assisted ventilation. In general, it seems very difficult to optimize the air velocity within all spaces in a very dense multi-space design like this case study. A new design that considers natural ventilation and its drivers has to be introduced.
27

Preference-based modelling and prediction of occupants window behaviour in non-air-conditioned office buildings

Wei, Shen January 2013 (has links)
In naturally ventilated buildings, occupants play a key role in the performance and energy efficiency of the building operation, mainly through the opening and closing of windows. To include the effects of building occupants within building performance simulation, several useful models describing building occupants and their window opening/closing behaviour have been generated in the past 20 years. However, in these models, the occupants are classified based on the whole population or on sub-groups within a building, whilst the behavioural difference between individuals is commonly ignored. This research project addresses this latter issue by evaluating the importance of the modelling and prediction of occupants window behaviour individually, rather than putting them into a larger population group. The analysis is based on field-measured data collected from a case study building containing a number of single-occupied cellular offices. The study focuses on the final position of windows at the end of the working day. In the survey, 36 offices and their occupants were monitored, with respect to the occupants presence and window use behaviour, in three main periods of a year: summer, winter and transitional. From the behaviour analysis, several non-environmental factors, namely, season, floor level, gender and personal preference, are identified to have a statistically significant effect on the end-of-day window position in the building examined. Using these factors, occupants window behaviour is modelled by three different classification methods of building occupants, namely, whole population, sub-groups and personal preference. The preference-based model is found to perform much better predictive ability on window state when compared with those developed based on whole population and sub-groups. When used in a realistic building simulation problem, the preference-based prediction of window behaviour can reflect well the different energy performance among individual rooms, caused by different window use patterns. This cannot be demonstrated by the other two models. The findings from this research project will help both building designers and building managers to obtain a more accurate prediction of building performance and a better understanding of what is happening in actual buildings. Additionally, if the habits and behavioural preferences of occupants are well understood, this knowledge can be potentially used to increase the efficiency of building operation, by either relocating occupants within the building or by educating them to be more energy efficient.
28

Retrofitted natural ventilation systems for a lightweight office building

Khatami, Narguess January 2014 (has links)
This study aimed to develop retrofitted natural ventilation options and control strategies for existing office buildings to improve thermal comfort, indoor air quality and energy consumption. For this purpose, a typical office building was selected in order to identify opportunities and constraints when implementing such strategies. Actual performance of the case study building was evaluated by conducting quantitative and qualitative field measurements including physical measurements and questionnaire surveys. Based on the actual building performance, a combination of Dynamic Thermal Simulation (using IES) and Computational Fluid Dynamics (using PHOENICS) models were built to develop appropriate natural ventilation options and control strategies to find a balance between energy consumption, indoor air quality, and thermal comfort. Several retrofitted options and control strategies were proposed and the best retrofitted natural ventilation options and control strategies were installed in the case study building. Post occupancy evaluation of the case study building after the interventions was also carried out by conducting physical measurements and questionnaire surveys. Post refurbishment measurements revealed that energy consumption and risk of overheating in the refurbished building were reduced by 9% and 80% respectively. The risk of unacceptable indoor air quality was also reduced by 60% in densely occupied zones of the building. The results of questionnaire surveys also revealed that the percentage of dissatisfied occupants reduced by 80% after intervention. Two new products including a Motorized ceiling tile and NVlogIQ , a natural ventilation wall controller, were also developed based on the results of this study.
29

Effects of solar radiation on buildings and thermal comfort

Zingano, Bernard Wilson January 2003 (has links)
This work was undertaken to investigate the perceived problem of Thermal Discomfort in Malawi. One observable effect of thermal discomfort was the amount of foreign exchange that was spent to import air conditioning devices. The purpose of the work was to find out, and quantify the problem of thermal discomfort and outline its effects to the people and country. In order to investigate the problem of thermal discomfort in depth in a place where the necessary data hardly existed a lot of work had to be done. The work has been outlined in four stages of research, analysis and documentation and these are as follows 1 Literature Review The subject of Thermal Comfort appears to be location specific, but the general principles are universal. In that context it was necessary to read widely on both historical and contemporary current work. The problem of thermal comfort in general was being discussed as early as 1758 and still remains a big area of research and discussion today. A considerable number of literature that specifically relate to the problem of thermal comfort in the tropics has been reviewed. The problem of scales for thermal comfort measurement has been discussed in detail. It is still not possible to quote a scale that is satisfactory. However, the recent approach of Adaptive Thermal Comfort Model seems to be closer to the answer than the others 2 Analysing Existing Relevant Information And Data In Malawi In the course of this work it was found out that quite a large amount of useful data existed in Malawi. However, this data was not standardised. Most of this data had to be cleaned and updated. Some of the old formulae are quoted in their original formats in order not to confuse the referencing. The data that exists in Malawi has been recorded on three types of instruments; namely the Gunn Bellum Spherical Pyranometer, the Camp Bell Stoke Sunshine Recorder and the Eppley Pyranometer. Most of the data was recorded using the Camp Bell Stokes Sunshine Recorder. The data recorded on the Gunn Bellum Spherical Pyranometer had to be related to that from the Camp Bell Stokes Sunshine Recorder. The former gave data that was more accurate as was found out when a comparison was made with data recorded on an Eppley Pyranometer. A paper on this subject was accepted for publication in the Renewable Energy Journal of WREN. Wind speeds, air temperatures, and humidity have been analysed to investigate the severity of thermal discomfort relative to locations in Malawi. This has resulted in the identification of three climatic zones. A tool for testing Thermal Discomfort severity of a location by calculating number Degree Days (D. d) if the altitude (AL) has been developed; as D. d = -575.994 In AL + 4226.6 3 Field Measurements In order to investigate some of the issues that came out of this work, it was felt simpler to conduct field measurements. For example it would have been possible to build typical experimental houses, and extract performance data on Thermal Comfort from these buildings. However, this approach would have been very expensive. On the other hand it was felt that it was possible to find in the field that were representative of typical buildings and could be prepared and tested to extract performance data for use in the work. The latter approach was adopted and has proved to be more realistic than the former. 4 Field Surveys There were certain areas where the only way to find information was not to conduct experiments but to conduct field conduct surveys. This was done once to find the Preferred Bath Water Temperature (PBWT) and deduce the Neutral Temperature Range for Malawi. This yielded very useful results. The first published paper on this work was in this area (copy of this publication is attached). The second area of field survey was to survey traditional buildings in seven selected districts stretching from latitude 9°S to 17°S; covering a terrestrial distance of over 1000 km; over altitudes from 52 to over 1600 metres above mean sea level (m. a. m. s. l). This again yielded very useful environmental data that explained why traditional buildings have certain structural elements as functions of the environment and the need to achieve Thermal Comfort. A number of useful equations have been developed. From that sub routine of this research of PBWT survey an equation was developed that related the bath temperature (h) to the air temperature (tab) as; tb =0.3772 tab + 36.4401. Part of this work was also published separately in 2001. From this equation the Thermal Comfort Temperature Range for Malawi was deduced as 22-27°C. From the survey of the traditional buildings, a number of structural elements were that are functions of Thermal Comfort were identified as derivatives of the desire to have Thermal Comfort in the buildings. A regression equation that can give values of irradiation of the locality in MJm 1 Day' was developed. Lastly the results have been extracted as recommendations directed at policy makers, and both Architects and Engineers to use this data and the results in their design work. It is also further recommended that the national buildings regulations could be updated and revised to incorporate some of the findings. It is strongly believed that some of the findings will be incorporated to update the two main Laws that regulate Public Health in Malawi. These are the Public Health Act; Cap. 34.01, and the Health and Safety at Work Act, 1977; of the Malawi Laws. All data that has been cleaned up or measured specifically for this work has been organised and tabulated into ready-to-use tables and are included.
30

Design of a solar cooling system for Iraq climate

Fakhraldin, Shahen Mohammed January 2016 (has links)
With the objectives of designing a solar cooling system with cold storage unit for the Iraqi climate, solar energy resources were assessed and methods were proposed to enhance harvesting the solar energy in the Iraqi climate. Where the results showed that adopting monthly average optimal tilt angles led to an increase in the amount of useful solar energy gained nearly 9%. A methodology of multi objective optimisation of solar absorption cooling system was then developed and demonstrated by applying it in a domestic application in Baghdad. Maximising the system performance in exergy, economic and environment were the objectives of the project. A decision-making tool was then implemented to select the most suitable design. The optimal proposed system has exergy efficiency of 56%, total cost rate of 4.19US$/hr, annual CO2 emission of 32199kg and payback period of 18.7years. After analysing the optimal configuration of the system, a cold thermal energy storage unit with the solar absorption cooling system was suggested in order to store the cold energy produced by the system at times when the solar energy is available (at daytime) and use (discharge) it at times when there is no solar energy available (at night). Next, a new control strategy was developed and applied in the system to make it more cost effective. Five scenarios were considered to manage the quantity of charging of the cold storage tank according to the splitting rate of the mass of the supplied chilled water by the chiller to the cold storage tank and the building. Finally, the chosen optimal system that uses an efficient controlled cold thermal energy storage, has exergy efficiency of 69.4%, total cost rate of 4.25US$/hr and total avoided annual CO2 emissions of 33.9% less than system without cold storage tank. Additionally, without any government incentive, the payback was recorded 9.3years, which was 50% less than the system without cold storage tank.

Page generated in 0.0149 seconds