• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Adesão de um cimento resinoso a uma cerâmica feldspática: avaliação da resistência adesiva, ângulo de contato e ph, em função de diferentes técnicas de condicionamento

Amaral, Regina [UNESP] 26 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-26Bitstream added on 2014-06-13T18:58:09Z : No. of bitstreams: 1 amaral_r_me_sjc.pdf: 3501879 bytes, checksum: f350dffbc6a2244de5a8f806e30513e5 (MD5) / O objetivo deste trabalho foi avaliar a durabilidade da resistência adesiva entre um cimento resinoso e uma cerâmica feldspática, o pH e o ângulo de contato da superfície cerâmica, submetida à diferentes tratamentos de superfície. Para análise do pH de superfície foram confeccionados 96 discos (8X3mm) da cerâmica feldspática (Vita VM7), os quais, foram divididos em 12 grupos (n=8): CS1- sem condicionamento; CS2- ácido fluorídrico (HF) 9% 1 min; CS3- CS2+lava/seca; CS4- CS3+silano (S); CS5- HF 4% 1 min; CS6- CS5+lava/seca; CS7- CS6+silano; CS8- HF 5% 1 min; CS9- CS8+lava/seca; CS10- CS9+silano 20 5min; CS11- CS9+neutralização+lava/seca+ultra-som; CS12- CS11+siano. Após, o pH foi medido com um peagâmetro digital. Para a análise do ângulo de contato foram confeccionados 40 discos com as mesmas dimensões (n=8): CS1- sem condicionamento; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+neutralização+lava/seca+ultra-som. As medidas foram realizadas com um Goniômetro. Para a resistência de união, foram confeccionados 40 blocos (6,4X6,4X4,8mm), os quais foram submetidos aos tratamentos (n=10): CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+neutralização+lava/seca+ultra-som. Os espécimes foram armazenados em água destilada (37°C) por 24h e seccionados nos sentidos x e y. Os corpos-deprova obtidos foram divididos em 2 condições (Seco- ensaio imediato; TCarmazenagem + termociclagem) e submetidos ao teste de microtração. Na análise do pH, CS6 obteve o maior resultado e CS5, CS8 e CS2, obtiveram os menores valores estatisticamente. Para o ângulo de contato, CS1 obteve médias maiores comparados aos outros grupos. Para resistência de união, CS2=CS1>CS3=CS4, independente do fator armazenagem. Somente o CS4 sofreu redução na resistência adesiva após TC. Conclui-se que a neutralização parece afetar negativamente a resistência adesiva... / The aim of this study was to evaluate the tensile bond strength of a resin-based cement to a feldspathic ceramic (Vita VM7), the pH and the contact angle on a ceramic surface, after submitted to surface conditioning methods. To analyze the pH of the ceramic surface, ninety six disks (8x3mm) of VM7 were fabricated and divided into 12 groups (n=8) according to each treatment condition (CS): CS1- without surface conditioning; CS2- hidrofluoridric acid (HF) 9% 1 min; CS3- CS2+wash/dry; CS4- CS3+silane (S); CS5- AHF 4% 1 min; CS6- CS5+wash/dry; CS7- CS6+silane; CS8- HF 5% 1 min; CS9- CS8+wash/dry; CS10- CS9+silane 5min; CS11- CS9+neutralizer+wash/dry+ ultrasonic cleaning; CS12- CS11+silane. Then, pH was measure using a digital peagameter. Another forty disks (8X3mm) were fabricated and divided into 5 groups to analyze the contact angle: CS1-without conditioning; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+ neutralizer +wash/dry+ultra-som, all groups were analyzed by means of a Goniômetro. Forty blocks (6,4x6,4x4,8mm) were fabricated, divided into 5 groups (n=10) and submitted to surface treatments to evaluate the bond strength: CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+ neutralizer +wash/dry+ ultrasonic cleaning. The specimens were storage in distilled water at 37°C for 24 hours and cut into to axes (x and y), then the bar specimens obtained were submitted to 2 conditions (Dry - immediate test; TC - storage + thermocycling) and to the microtensile bond strength test. pH values were significantly high for CS6 compared to that of CS5, CS8 and CS2. CS1 had the highest contact angle. In the microtensile bond strength, CS2=CS1>CS3=CS4, independently from the storage condition. CS4 had the lowest microtensile bond strength value after TC. The neutralization decrease the bond strength significantly, which was evidenced by the high contact angles after the surface neutralization.
2

Efeito do tratamento da superfície, ciclagem térmica e fadiga mecânica na resitência de união entre uma cerâmica reforçada por dissilicato de lítio e em cimento resinoso / Effect of surface treatments, thermocycling and loading on the bond between a ceramic and a resin cement

Guarda, Guilherme Bottene, 1987- 18 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Mário Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:18:54Z (GMT). No. of bitstreams: 1 Guarda_GuilhermeBottene_M.pdf: 2504078 bytes, checksum: 72f1d754db2ac04524c40271b35d7366 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi investigar o efeito de diferentes tratamentos de superfície, fadiga mecânica e termociclagem na resistência da união à microtração da cerâmica IPS e.max (Ivoclar) e do cimento resinoso de ativação dupla. Métodos: 18 blocos de cerâmica (10 mm de comprimento x 7 mm de largura x 3 mm de espessura) foram confeccionados e divididos em 6 grupos (n=3): Grupos 1, 2 e 3 - jateamento por 5 segundos com partículas de óxido de alumínio de 50?m; Grupos 4, 5 e 6 - condicionamento com acido hidrofluorídrico à 10% por 20 segundos. O silano Rely X Ceramic Primer foi aplicado sobre todos os espécimes e seco por 5 minutos. Após, os blocos de cerâmica foram unidos à blocos de compósito restaurador Tetric N-Ceram (Ivoclar-Vivadent) com cimento resinoso RelyX ARC (3M ESPE), sob carga estática de 500 gf por 2 minutos. O excesso de cimento foi removido com micropincel e fotoativado por 160 segundos (40 s cada face) com um aparelho de LED (UltraLume 5, Ultradent). Os espécimes dos grupos 1 e 4 foram armazenados em água destilada a 37°C por 24 h. Nos grupos 2 e 5, os espécimes foram submetidos a 3.000 ciclos térmicos entre 5°C e 55°C. Para os grupos 3 e 6, os espécimes foram submetidos ao ensaio de fadiga mecânica por 100.000 ciclos com 2 Hz. Os espécimes foram seccionados perpendiculares a área de união para obtenção de palitos com área seccional de 1mm2 (25 palitos por grupo) e submetidos ao ensaio de resistência de união à microtração em máquina de teste universal (EZ Test - Shimadzu) com velocidade de 0,5 mm/min. Foi utilizado para verificar o padrão de fratura uma lupa estereoscópica (Olympus) com aumento de 40x. Os dados foram submetidos à Análise de Variância de 2 fatores e ao teste de Tukey (p<0,05). Os valores de resistência de união à microtração (MPa) foram: 26,9 ± 6,9, 22,2 ± 7,8 e 21,2 ± 9,1 para os Grupos 1 a 3 e 35,0 ± 9,6, 24,3 ± 8,9 e 23,9 ± 6,3 para os Grupos 4 a 6. O grupo controle submetido ao teste de fadiga e termociclado mostrou predominância de padrão de fratura adesiva para o tratamento de superfície com acido hidrofluorídrico a 10% e padrões adesiva e mista para tratamento de superfície com 50um de oxido de alumínio. Concluindo a fadiga e a termociclagem diminuíram significantemente a resistência de união à microtração para ambos os tratamentos de superfície das cerâmicas comparada ao grupo controle. Condicionamento com acido hidrofluorídrico a 10% aumentou a resistência de união à microtração para o grupo controle / Abstract: The aim of this study was to investigate the effect of surface treatments, mechanic fatigue and thermocycling tested on the microtensile bond strength of the ceramic IPS e.max Press (Ivoclar Vivadent) luted with dual-cured resin cement. Eighteen ceramic bars (10mm length x 7mm width x 3.0mm thickness) were fabricated, and divided into 6 groups (n=3): Groups 1, 2 and 3 - air particle abraded for 5 s with 50?m aluminum oxide particles; Groups 4, 5 and 6 - acid etched with 10% hydrofluoric acid for 20 s. Coupling agent silane was applied on to all bond surface specimens and allowed to dry for 5 s and the ceramic bars were bonded to a block of composite resin Tetric N-Ceram (Ivoclar-Vivadent) with Rely X ARC (3M ESPE) resin cement and placed under a 500 g static load for 2 min. The cement excess was removed with a disposable microbrush and 40 s light-activation (four activations) were performed using a LED curing unit (UltraLume LED 5, Ultradent). The specimens of the groups 1 and 4 were stored in distilled water at 37°C for 24 hours, groups 2 and 5 were submitted to 3,000 thermocycles between 5°C and 55°C and groups 3 and 6 submitted to a fatigue test for 100,000 cycles with 2 HZ. Specimens were sectioned perpendicular to the bonding area to obtain 1mm2 sectional area beams (25 beams per group) and submitted to a microtensile bond strength test in a universal testing machine (EZ Test - Shimadzu), at a crosshead speed of 0.5mm/min. The fracture specimens were observed under optical microscopy (Olympus) at a 40x magnification. Data were submitted to ANOVA and Tukey's test (p?0.05). Results: The microtensile bond strength values (MPa) were: 26.9 ± 6.9, 22.2 ± 7.8 and 21.2 ± 9.1 for G1-G3 and 35.0 ± 9.6, 24.3 ± 8.9 and 23.9 ± 6.3 for G4-G6. The control group, fatigue tested and thermocycled groups showed a predominance of failure adhesive for surface treatment with 10% hydrofluoric acid and adhesive and mixed for surface treatment with 50 ?m Al2O3. In conclusion the fatigue and thermocycling decreased significantly the microtensile bond strength for both ceramic surface treatments compared to control groups. Etching with 10% hydrofluoric acid increased the microtensile bond strength for the control group / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
3

Morfologia da superficie e resistencia da união de ceramica IPS Empress Esthetic submetida a diferentes tratamentos / Bond strenght and surface/interface morphology of luting polymers and glass ceramic etched for different periods

Naves, Lucas Zago, 1981- 13 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Carlos Jose Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:11:57Z (GMT). No. of bitstreams: 1 Naves_LucasZago_M.pdf: 3732245 bytes, checksum: f19061d71b96dbce2d54cda8b37f2ba9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a morfologia de superfície e resistência de união ao microcisalhamento entre a cerâmica reforçada por leucita IPS Empress Esthetic (Ivoclar- Vivadent) e o cimento resinoso Variolink II (Ivoclar-Vivadent), em diferentes tempos de condicionamento da cerâmica, com e sem aplicação do adesivo após o uso do silano. Setenta e dois discos cerâmicos (6mm de diâmetro x 2mm de espessura) foram confeccionados, embutidos em resina e divididos em 12 grupos (n=6), definidos pelo tempo condicionamento com ácido fluorídrico 10% e aplicação ou não de adesivo após o uso do silano: G1 e G7 - 10s de condicionamento ácido, G2 e G8 - 20 s; G3 e G9 - 40 s; G4 e G10 - 60 s; G5 e G11 - 120 s e G6 e G12 - 60 + 60s. O silano foi aplicado em todos os grupos e metade dos grupos (de G7 a G12) receberam uma camada do adesivo (Scotchbond MP - 3M/ESPE). Molde de elastômero com dois orifícios cilíndricos (1,2mm de diâmetro x 2mm de altura) foi adaptado sobre a superfície da cerâmica para a construção de dois cilindros por amostra, totalizando 12 cilindros por grupo. Para tal, os orifícios foram preenchidos com o cimento resinoso (Variolink II), fotoativados por 40 s e submetidos ao ensaio de resistência de união ao microcisalhamento a velocidade de 0,5mm/min. e o padrão de fratura foi analisado. Os dados foram submetidos à Análise de Variância e ao teste de Student-Newman-Keul (p<0,05). A topografia e a interface de união foram avaliadas em MEV. A resistência de união ao microcisalhamento (MPa) foi 19,4±3,5 (G1), 22,3±5,1 (G2), 22,2±3,2 (G3), 17,8±2,1 (G4), 15,3±3,0 (G5), 14,3±1,8 (G6) para os grupos tratados com silano, e 17,4±4,8 (G7), 21,3±2,1 (G8), 21,1±2,3 (G9), 24,7±5,8 (G10), 20,4±2,2 (G11) e 18,5±4,6 (G12) para os grupos tratados com silano + adesivo. Houve redução de falhas adesivas e aumento das mistas com o aumento do tempo de condicionamento para os grupos tratados com silano e equilíbrio da falhas adesivas e mistas para os grupos tratados com silano + adesivo, exceto para os grupos G11 e G12 onde houve predominância de falhas mistas. Pouca alteração na topografia de superfície foi detectada nas amostras condicionadas por 10s, canais apresentando sulcos profundos puderam ser notados em praticamente toda a extensão das superfícies cerâmicas recondicionadas (60+60s - G6 e G12). Espaços não-preenchidos ao longo da interface cerâmica-cimento resinoso foram detectados em intensidade crescente a partir de 60s de condicionamento, quando apenas o silano foi aplicado, enquanto um preenchimento homogêneo, caracterizado por íntimo contato com a cerâmica pode ser percebido quando o adesivo foi utilizado, exceto para o grupo recondicionado - G12. / Abstract: This study evaluated the influence of etching times on surface/interface morphology and micro-shear bond strength to Empress Esthetic leucite-reinforced glass ceramic (Ivoclar-Vivadent), with or without application of an unfilled resin after silane. Ceramic discs were divided into 12 groups (n = 6), defined by the etching time with 10% hydrofluoric acid: G1 and G7 - etching for 10s, G2 and G8 - 20 s; G3 and G9 - 40 s; G4 and G10 - 60 s; G5 and G11 - 120 s and G6 and G12 - 60 + 60s. Half of the groups (G7 to G12) received a layer of unfilled resin (Scotchbond MP/ 3M ESPE) after silane coupling. Micro-shear bonding test using Variolink II resin cement (Ivoclar-Vivadent) was performed, and data submitted to two-way ANOVA and Student-Newman-Keuls' test (p < 0.05). Evaluation of the etching pattern and bonding interfaces was conducted by Scanning Electron Microscopic (SEM). Means micro-shear bond strengths (MPa) were 19.4±3.5 (G1), 22.3±5.1 (G2), 22.2±3.2 (G3), 17.8±2.1 (G4), 15.3±3.0 (G5), 14.3±1.8 (G6) for groups treated with silane, and 17.4±4.8 (G7), 21.3±2.1 (G8), 21.1±2.3 (G9), 24.7±5.8 (G10), 20.4±2.2 (G11) e 18.5±4.6 (G12) for groups treated with silane and unfilled resin. Poor etching topography was detected on 10s etched surfaces, whereas fissures forming deep grooved channels were extensively observed in 120s and 60+60s ceramics surfaces. Unfilled spaces underlying the ceramic-resin cement interface were detected when only silane was applied. Fully completion of the irregularities on 60s and 120s samples were detected using the unfilled resin, although this material was unable to completely fill the irregularities on 60+60s (G12) ceramic. When only silane was applied, the 60s and the groups etched for longer periods (120 and 60+60s - G5 and G6) showed lower bond strengths, but when both silane and unfilled resin were applied, all etching times generally showed similar values. The etching protocol influenced the surface/interface topography and bond strength to ceramic. The application of unfilled resin was able to infiltrate all unfilled spaces beneath the ceramic-resin cement interface detected when only silane was applied, except on the re-etched (60+60s - G12) ceramic. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários

Page generated in 0.0553 seconds