Development of an Acoustic Wave Based Biosensor for Vapor Phase Detection of Small Molecules

Stubbs, Desmond Dion 03 November 2005 (has links)
For centuries scientific ingenuity and innovation have been influenced by Mother Natures perfect design. One of her more elusive designs is that of the sensory olfactory system, an array of highly sensitive receptors responsible for chemical vapor recognition. In the animal kingdom this ability is magnified among canines where ppt (parts per trillion) sensitivity values have been reported. Today, detection dogs are considered an essential part of the US drug and explosives detection schemes. However, growing concerns about their susceptibility to extraneous odors have inspired the development of highly sensitive analytical detection tools or biosensors known as electronic noses. In general, biosensors are distinguished from chemical sensors in that they use an entity of biological origin (e.g. antibody, cell, enzyme) immobilized onto a surface as the chemically-sensitive film on the device. The colloquial view is that the term biosensors refers to devices which detect the presence of entities of biological origin, such as proteins or single-stranded DNA and that this detection must take place in a liquid. Our biosensor utilizes biomolecules, specifically IgG monoclonal antibodies, to achieve molecular recognition of relatively small molecules in the vapor phase.
2

Theoretical and Experimental Characterization of Time-Dependent Signatures of Acoustic Wave Based Biosensors

Lee, Sang Hun 13 July 2006 (has links)
The object of this thesis research is to facilitate the appraisal and analysis of the signatures of the modern acoustic wave biosensors, as well as to improve the experimental methodology to enhance sensor performance. For this purpose, both theoretical characterization of acoustic wave sensor signatures and experimental studies for the most frequently used acoustic wave biosensors, the liquid phase QCM (quartz crystal microbalance) and the vapor phase SAW (surface acoustic wave) sensors, are presented. For the study of SAW vapor phase detection, the author fabricated different types of two-port SAW resonator sensors on quartz substrates and designed and performed a significant number of detection experiments. These were conducted both with calibrated or known target samples under laboratory conditions at Georgia Tech Hunt Lab and with samples of unknown concentrations such as seized crack cocaine (courtesy of Georgia Bureau of Investigation, GBI) to see the sensors capability to work in the field conditions. In addition, the dependence of the SAW sensor signatures on specific locations of the surface perturbation was investigated to account for some observed abnormal responses. Finally, a novel approach to classify and visualize chemically analogous substances is introduced. The author expects that the thesis work herein may contribute to the study of the modern acoustic wave biosensors which includes but is not limited to: the establishment of underpinning theory that will aid in the evaluation of the signatures; the practical aspects of design and fabrication of SAW devices specific to the vapor phase immunoassay; the development of efficient experimental methodologies; the strategic immobilization of a biolayer on SAW resonator based biosensors; and, the acquisition of reference data for the development of commercial acoustic wave sensors.
3

Investigation of Flexural Plate Wave Devices for Sensing Applications in Liquid Media

Matthews, Glenn Ian, gimatthews@ieee.org January 2007 (has links)
In this thesis, the author proposes and presents a novel simulation technique for the analysis of multilayered Flexural Plate Wave (FPW) devices based on the convergence of the Finite Element method (FEM) with classical Surface Acoustic Wave (SAW) analysis techniques and related procedures. Excellent agreement has been obtained between the author's approach and other more conventional modelling techniques. Utilisation of the FEM allows the performance characteristics of a FPW structure to be critically investigated and refined before undertaking the costly task of fabrication. Based on a series of guidelines developed by the author, it is believed the proposed technique can also be applied to other acoustic wave devices. The modelling process developed is quite unique as it is independent of the problem geometry as verified by both two and three dimensional simulations. A critical review of FEM simulation parameters is presented and their effect on the frequency domain response of a FPW transducer given. The technique is also capable of simultaneously modelling various second-order effects, such as triple transit, diffraction and electromagnetic feedthrough, which often requires the application of several different analysis methodologies. To verify the results obtained by the author's novel approach, several commonly used numerical techniques are discussed and their limitations investigated. The author initially considers the Transmission Matrix method, where it is shown that an inherent numerical instability prevents solution convergence when applied to large frequency-thickness products and complex material properties which are characteristic of liquids. In addition the Stiffness Matrix method is investigated, which is shown to be unconditionally stable. Based on this technique, particle displacement profiles and mass sensitivity are presented for multilayered FPW structures and compared against simpler single layer devices commonly quoted in literature. Significant differences are found in mass sensitivity between single layer and multilayered structures. Frequency response characteristics of a FPW device are then explored via a spectral domain Green's function, which serves as a further verification technique of the author's novel analysi s procedure. Modifications to the spectral domain Green's function are discussed and implemented due to the change in solution geometry from SAW to FPW structures. Using the developed techniques, an analysis is undertaken on the applicability of FPW devices for sensing applications in liquid media. Additions are made to both the Stiffness Matrix method and FEM to allow these techniques to accurately incorporate the influence of a liquid layer. The FEM based approach is then applied to obtain the frequency domain characteristics of a liquid loaded FPW structure, where promising results have been obtained. Displacement profiles are considered in liquid media, where it is shown that a tightly coupled Scholte wave exists that is deemed responsible for most reported liquid sensing results. The author concludes the theoretical analysis with an in-depth analysis of a FPW device when applied to density, viscosity and mass sensing applications in liquid media. It is shown that a single FPW device is potentially capable of discriminating between density and viscosity effects, which is typically a task that requires a complex and costly sensor array.
4

A CO2 measurement system for low-cost applications using chemical transduction

Maxwell, Andrew Douglas January 2002 (has links)
It is demonstrated that by using a miniature chemical reaction vessel under adaptive mechatronic control, it is possible to design and construct a low-cost carbon dioxide measurement system. With further development such a system would be potentially suitable for low-cost commercial application, in particular as sacrificial, single-mission instrumentation packages in horticultural cargo monitoring. Current instrumentation systems for carbon dioxide (CO2) gas measurement are reviewed and their limitations with respect to low cost commercial applications determined. These utilise technology intended for laboratory measurements. In particular the optical energy absorbance of CO2 in the infra-red electromagnetic spectrum. These systems require large optical paths (typically 10cm) in order to measure small CO2 concentrations. This in turn has a large impact on the physical size of the sensing system. Of the many applications requiring online CO2 sensing packages (such as medical, petroleum, environmental and water treatment)the horticultural industry is the primary focus for this research. CO2 sensing systems are primarily used in horticulture to monitor the produce environment and help extend storage time. For these applications CO2 concentrations are typically low (in the range 0 to 1%) and the paramount need is for low-cost (and possibly disposable) sensing packages. The basis of the measurement technique is the use of bulk (but small volume) aqueous chemical reaction under mechatronic control. Unlike thin film technologies where very thin membranes are passively exposed to the gaseous sample, here a small volume (approximately 2mL) of simple and very cheap liquid chemical indicator (calcium hydroxide solution) is used to produce an opaque precipitate. CO2 concentration is then assessed by low-cost optical attenuation measurements of the developing opacity of the solution. The instrumentation package comprises pumps, flowmeter, reaction cell and infra-red optics for the turbidity measurement, plus reagent and waste vessels, pipelines and electronics. During each measurement cycle, the reaction cell is flushed, with fresh chemical indicator and a sample of gas admitted. The indicator and the sample gas are then vigorously mixed and the change in the indicators optical properties measured at regular intervals. An embedded 8-bit microcontroller performs the necessary analysis to deduce the CO2 concentration (as percentage by volume) for the sample gas by reference to one or more of five ``Time-To-Threshold'' calibration models. These models evaluate the trend in turbidity development as precipitate is formed. First and second prototypes of the measurement system have been constructed and their (low-cost) components and overall performance evaluated, the first a `proof-of-concept' and the second to investigate methodology shortcomings. As a result the design of a third prototype is outlined. The measurement systems have been shown to work adequately well within expected limitations, resulting in a usable low-cost measurement technique. The current prototypes have a useful range of at least 5% to 100% CO2 with a discrimination of typically +-6%. Deficiencies, particularly performance at low concentrations, are identified and potential enhancements for future prototypes proposed.
5

Algorithmes, méthodes et modèles pour l'application des capteurs à ondes acoustiques de surface à la reconnaissance de signatures de composés chimiques / Algorithms, methods and models for the application of surface acoustic wave sensors to the recognition of chemical compound signatures

Hotel, Olivier 11 December 2017 (has links)
Récemment, les systèmes multicapteurs ont trouvé de nombreuses applications dans des domaines tels que l’industrie agroalimentaire, l’environnement, la médecine et la défense. Parmi les technologies existantes, les capteurs à ondes acoustiques de surface sont l’une des plusprometteuses et fait l’objet de nombreuses recherches. Les travaux décrits dans ce manuscrit concernent le développement d’algorithmes permettant la reconnaissance de composés chimiques et l’estimation de leur concentration. Cette étude décrit une méthode permettant d’estimer les paramètres des phénomènes de transduction. L’intérêt de ces derniers est mis en évidence expérimentalement dans des applications consistant à identifier des toxiques chimiques, des capsules de café contrefaites et à détecter la présence de DMMP et de 4-NT en présence d’interférents. / Recently, gas sensor arrays have found numerous applications in areas such as the food, the environment, the medicine and the defenseindustries. Among the existing technologies, the surface acoustic wave technology is one of the most promising and has been the subject of abundant research. The work described in this manuscript concerns the development of algorithms allowing the recognition of chemical compounds and the estimation of their concentration. This study describes a method for estimating the parameters of transduction phenomena. Their interest is demonstrated experimentally in applications consisting in identifying toxic chemical compounds, counterfeit coffee capsules and in detecting the presence of DMMP and 4-NT in the presence of interfering compounds.