Spelling suggestions: "subject:"aerobic biofilter"" "subject:"eerobic biofilter""
1 |
Utilização de reatores microbianos com celulas imobilizadas no tratamento de efluente de uma industria de bebidas / Use of microbial reactors contaning immobilized cells on the treatment of the wastewater of a beverage industryCruz, Juliana Gisele Belote D'Arcadia 23 July 2007 (has links)
Orientador: Lucia Regina Durrant / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-08T21:34:47Z (GMT). No. of bitstreams: 1
Cruz_JulianaGiseleBeloteD'Arcadia_D.pdf: 1094793 bytes, checksum: 9fff23fc94e5bf172cdf4158fde536f3 (MD5)
Previous issue date: 2007 / Resumo: O presente estudo avaliou a utilização da tecnologia de tratamento de despejos líquidos de uma indústria cervejeira e de refrigerantes pelo sistema biológico aeróbio. Buscou-se a remoção da carga orgânica mediante quantificação da demanda bioquímica de oxigênio (DBO), demanda química de oxigênio (DQO), nitrogênio amoniacal total, turbidez, sólidos sedimentáveis (SS), fósforo (P), condutividade e toxicidade. O sistema de tratamento proposto foi constituído por quatro reatores em série com volume total de 16 L. A alimentação foi realizada de forma contínua pela parte inferior e por gravidade. Para a imobilização dos microrganismos nos reatores foi utilizado, como suporte, argila expandida. Para o sistema aeróbio foi utilizada aeração prolongada mediante injeção ascendente de oxigênio. As análises foram realizadas diariamente, no afluente do reator e no efluente tratado em diferentes tempos de retenção hidráulica (TRH/h). Os resultados obtidos mostraram que o sistema de tratamento, empregando 4 reatores acoplados, foi eficiente para a remoção da carga orgânica poluente do efluente da indústria. Ocorreu diminuição da DQO em todos os tempos de retenção hidráulica testados. O TRH 1,9 mostrou ser o mais eficiente, visto que é o tempo com a maior vazão, fato de extrema
importância para o tratamento de efluentes industriais. Neste TRH houve maior porcentagem de remoção da DBO (67,4%), toxicidade com microcrustáceo Daphinia similis (52,3%), condutividade (13,13%), além de significativa remoção da DQO (58,7%) / Abstract: The present study the treatment of the waste waters of a beer and soft drink industry by an aerobic biological system was evaluated. The removal of the organic load by means of the quantification of the biochemical oxygen demand (BOD), chemical oxygen demand (COD), total ammoniacal nitrogen, turbidity, sedimented solids (SS), phosphorus (P), conductivity and toxicity. Were determined proposed the consisted of four reactors in series with a total volume of 16 L. The feeding was carried out carried out continuous by through the of the bioreactor inferior part and by gravity. Expanded clay was used as support for the immobilization of the microorganisms in the reactors. Continuous aeration by means of ascending injection of oxygen was used for the aerobic system. The analyses were performed daily in samples from the treated and untreated industrial effluent using different times of hydraulical retention (HRT/h). The results showed that the treatment system, using 4 connected reactors was efficient for the removal of the pollutant organic load of the industrys effluent. Reduction of the COD occurred in all the tested hydraulical retention times used HRT of 1.9 was found to be the most efficient HRT, since it was the time with the hioghest outflow, fact that is of extreme importance for the treatment of industrial effluents. In this HRT there was a greater percentage of reduction of the BOD (67.4%), the toxicity with the Daphinia similis (52.3%) and conductivity (13.13%), besides the significant reduction of the COD (58.7%) / Doutorado / Doutor em Ciência de Alimentos
|
2 |
Recirculação de efluente visando a desnitrificação em sistemas combinados anaeróbio-aeróbio para tratamento de esgoto sanitário / Effluent recirculation aiming denitrification in anaerobic-aerobic combined systems for sewage treatmentFoco, Mário Luiz Rodrigues, 1981- 12 March 2014 (has links)
Orientador: Edson Aparecido Abdul Nour / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T09:02:50Z (GMT). No. of bitstreams: 1
Foco_MarioLuizRodrigues_D.pdf: 4289583 bytes, checksum: d1eb026afe6452cef2dbcf25f6dbef83 (MD5)
Previous issue date: 2014 / Resumo: Neste estudo foi verificado o desempenho de um sistema combinado anaeróbio-aeróbio na remoção de matéria orgânica e de compostos de nitrogênio presentes em esgoto sanitário, por meio da utilização de recirculação do efluente tratado para o início do sistema, de forma a propiciar a desnitrificação sem adição de carbono ou alcalinizante externos. Foram estudados dois tipos de sistemas: Sistema 1 (escala de bancada) composto por filtro anóxico (FA) seguido de biofiltro aerado submerso (BAS) e decantador secundário (DS) com os respectivos volumes: 32,6; 17,6 e 7,2 L; Sistema 2 (escala piloto) constituído por filtro anaeróbio/anóxico (FAA), seguido de BAS e DS com os respectivos volumes: 298,7; 131.5 e 188,5 L. As razões de recirculação (R) utilizadas foram: 0,5; 1,5; 2,0; 3,0 e 4,0. No Sistema 1, com R=4,0 a máxima desnitrificação teórica (D%) possível foi de 86±5%, nessa configuração alcançou-se remoções de demanda química de oxigênio (DQO) e Nitrogênio Total (NT) de 92±4% e 83±8%, respectivamente. No Sistema 2, com R=3,0 o valor da D% possível foi de 78±9%, nessa configuração alcançou-se remoções de DQO e NT de 89±4 e 60±7%, respectivamente. Os resultados indicam a viabilidade do uso da recirculação do efluente tratado, na configuração proposta pelo Sistema 1, como alternativa para remoção de nitrogênio em Estações de Tratamento de Esgoto Combinadas Anaeróbio-Aeróbia, com biomassa imobilizada, uma vez que as concentrações finais de Nitrogênio Total (12±3 mg N L-1) estão abaixo do valor estipulado pela Resolução CONAMA N° 357/2005 / Abstract: This study verified the performance of anaerobic-aerobic combined systems in removing organic matter and nitrogen compounds from sewage by recirculation of treated effluent to the beginning of the system, aiming denitrification without addition of external carbon or alkalinity. System 1 (bench scale) were an anoxic filter (AF) followed by aerated submerged biofilter (ASB) and clarifier with respective volumes: 32.6, 17.6 and 7.2 L. System 2 (pilot scale), were an anaerobic/anoxic filter (AAF), followed by ASB and clarifier with their volumes: 298.7, 131.5 and 188.5 L. The recirculation ratios (R) were 0.5, 1.5, 2.0, 3.0 and 4.0. In System 1, with R=4.0 the maximum theoretical denitrification (D%) possible was 86±5%, and this configuration achieved removals of chemical oxygen demand (COD) and Total Nitrogen (TN) of 92±4% and 83±8%, respectively. In system 2, with R=3.0 the D% possible was 78±9%, and this configuration reached removal of COD and NT of 89±4 and 60±7%, respectively. The results indicate the feasibility of using effluent recirculation, in the System 1 configuration, as an alternative to nitrogen removal in sewage anaerobic-aerobic combined treatment plants, with immobilized biomass, since the final concentrations of Total Nitrogen (12±3 mg N L-1) are below the value established by CONAMA Resolution No. 357/2005 / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
|
3 |
Tratamento de efluente anaeróbio = condicionamento em filtro de areia visando lançamento e reúso / Anaerobic effluent treatment : sand filters conditioning to disposal or reuse applicationsDominato, Daniele Tonon 17 August 2018 (has links)
Orientador: Bruno Coraucci Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-17T23:41:07Z (GMT). No. of bitstreams: 1
Dominato_DanieleTonon_D.pdf: 5136145 bytes, checksum: bc4588de570931c9d0ab9bc99456069f (MD5)
Previous issue date: 2011 / Resumo: A escassez cada vez maior de água doce devido ao crescimento demográfico, a urbanização e, provavelmente, as mudanças climáticas, tem dado lugar ao uso crescente de águas residuárias na agricultura. Atualmente, essa prática é uma realidade, principalmente na região sudeste de São Paulo, onde os conflitos pelos usos múltiplos da água são constantes. Frente a essa situação, o objetivo desse trabalho foi avaliar o condicionamento de efluentes sanitários, de um sistema composto por filtros anaeróbios e pós-tratamento por filtros de areia (com espessura de 0,75 m) com altas taxas de aplicação diárias que variaram de 300 a 800 Lm-2, visando reúso agrícola e/ou para lançamento em corpos hídricos. Verificou-se uma remoção na concentração de matéria orgânica em termos de DQO, DBO e COD acima de 90 % no efluente dos filtros de areia em todas as taxas de aplicação estudadas. Os resultados apontam que o parâmetro limitador para a utilização de taxas de aplicação diárias superiores a 700 L m-2 foi a concentração de nitrogênio amoniacal produzido nos filtros de areia, superiores a 20 mg L-1, obrigando a implantação de um sistema de aeração superior. A dosagem de hipoclorito de cálcio empregada para adequar o efluente a legislação foi de 3,25 mg L-1 com um tempo de contato de 45 minutos e a classificação do efluente final para a utilização deste na agricultura foi C3S1, estando apto a ser utilizado com um grau moderado de restrição. Como os resultados foram satisfatórios, comprova-se que é possível a aplicação de maiores taxas hidráulicas nos leitos de areia / Abstract: Increasing scarcity of freshwater due to demographic growing, urbanization and, climate changing are the reason of increasing use of the wastewater in agriculture. Nowadays, this practice is a reality, mainly in São Paulo in the southeast areas, where the conflicts caused by multiples use of water are constant. Based on this situation, the aiming of this investigation was to evaluate wastewater conditioning, from a system composed by anaerobic filters and post - treated by sand filters (0,75m height) with high daily application rates which varied from 300 to 800 L m-2, agriculture reuses and/or discharging into receiving waters. An organic matter removing of 90% in terms of COD, BOD and DOC was observed in sand filters effluent in all application rates which were studied. Results have shown that the limitation parameter to use application rates over 700 L m-2 was the ammonium nitrogen concentration which are produced by sand filters and were over 20 mg L-1, forcing to implant a superior aeration system. Calcium hypochlorite dose, used to make the effluent appropriate according to the law, was 3,25 mg L-1 with a contact time of 45 minutes and the final effluent classification to use it in agriculture was C3S1, which is suitable to be used with a moderate degree of restriction. As the results were satisfactory, higher application hydraulic rates in sand filters are proved to be possible / Doutorado / Saneamento e Ambiente / Doutor em Engenharia Civil
|
4 |
Estudo de tratabilidade dos lixiviados de aterros sanitários: ênfase no tratamento consorciado com esgoto sanitário em sistemas aeróbios / Study of tractability of sanitary landfill leachate: emphasis on co-treatment with domestic wastewater in aerobic systemsFerraz, Fernanda de Matos 14 January 2014 (has links)
Esta tese foi dedicada à duas alternativas para tratamento dos lixiviados de aterros sanitários. A primeira delas, o tratamento consorciado do lixiviado com esgoto sanitário em sistemas aeróbios, teve como objetivo principal verificar se a remoção da matéria orgânica do lixiviado seria devida à biodegradação ou à simples diluição no esgoto sanitário. Para responder esse questionamento, propôs-se o método tentativo \"equivalente em ácido húmico\" (Eq.AH). Em ensaios com reatores de lodos ativados (10 L) operados em batelada, avaliaram-se as remoções de matéria orgânica e nitrogênio para diferentes misturas de lixiviado e esgoto sanitários brutos e pré-tratados, com proporções volumétricas de lixiviado de 0, 0,2, 2 e 5%. O tratamento foi mais eficiente para a mistura esgoto bruto e lixiviado pré-tratado por air stripping (para remoção da amônia) na proporção volumétrica de 2%. Essa condição foi avaliada em reatores piloto de lodos ativados (95 L) e biofiltro aerado submerso (178 L), alimentados continuamente com tempo de detenção hidráulica (TDH) de 24 h. O reator piloto de lodos ativados removeu 59% do COD e a eficiência de nitrificação foi de 60%; enquanto que o biofiltro removeu 83% do COD e eficiência de nitrificação foi de 77%. Com o método tentativo Eq.AH, verificou-se que a remoção da matéria orgânica do lixiviado pré-tratado se deu por biodegradação parcial com o esgoto sanitário, resultado confirmado por espectroscopia de infravermelho por transformada de Fourier. As remoções do COD Eq.AH nos reatores piloto de lodos ativados e biofiltro aerado submerso foram de, respectivamente, 47 e 71%. Adicionalmente, o monitoramento da remoção da matéria orgânica pôde ser realizado com eficácia pelo teste de coloração com nanquim, utilizando o método de classificação de tonalidades proposto nesta Tese. A segunda alternativa proposta nesta Tese consistiu no tratamento dos lixiviados bruto e pré-tratado com cal em reatores de lodos ativados. Os resultados, todavia, foram insatisfatórios: indicaram que essa alternativa se mostrou inviável: após 20 dias de aeração nos reatores de bancada alimentados em batelada, a remoção da matéria orgânica foi inferior a 40% e a remoção do nitrogênio foi devida à volatilização da amônia. / This thesis was dedicated to two alternatives for landfill leachate treatment. The first one, the aerobic co-treatment of leachate and domestic wastewater in aerobic systems, aimed to verify if the organic matter of leachate was removed by biodegradation or dilution with domestic wastewater. To answer this questioning, it was proposed the tentative method \"equivalent in humic acid\" (Eq.HA). In the experiments with bench-scale activated sludge reactors (10 L) operated in batch mode, it was evaluated the organic matter and nitrogen removal from mixtures containing raw and pre-treated leachate and domestic wastewater, at the volumetric ratios of 0, 0.2, 2 and 5%. The treatment was mostly efficient when it was used the mixture domestic wastewater and leachate pre-treated by air stripping (for ammonia removal), at a volumetric ratio of 2%. This condition was also evaluated in a pilot-scale activated sludge reactor (95 L) and a submerged aerobic biofilter (178 L), operated under continuous-flow regime with a 24-h hydraulic retention time. The pilot-scale activated sludge reactor removed 59% of DOC and nitrification efficiency was 60%; whereas the submerged aerobic biofilter removed 83% of DOC and nitrification efficiency was 77%. Using the Eq.HA approach, it was determined that pre-treated leachate organic matter removal was due to partial biodegradation with domestic wastewater, which was confirmed by Fourier transform infrared spectroscopy. The removals of COD Eq.HA were 47% for the pilot-scale activated sludge reactor and 71% for the submerged aerobic biofilter. Aditionally, organic matter could be assessed with the India ink reverse stain test, using the proposed method for tonalities classification. The second alternative proposed by this Thesis consisted in the treatment of raw and pre-treated leachate by lime addition, using activated sludge reactors. The results did not indicate the feasibility of this alternative: after 20 days of aeration, the organic matter removal was lesser than 40%, and nitrogen was mostly removed by ammonia volatilization.
|
5 |
Estudo de tratabilidade dos lixiviados de aterros sanitários: ênfase no tratamento consorciado com esgoto sanitário em sistemas aeróbios / Study of tractability of sanitary landfill leachate: emphasis on co-treatment with domestic wastewater in aerobic systemsFernanda de Matos Ferraz 14 January 2014 (has links)
Esta tese foi dedicada à duas alternativas para tratamento dos lixiviados de aterros sanitários. A primeira delas, o tratamento consorciado do lixiviado com esgoto sanitário em sistemas aeróbios, teve como objetivo principal verificar se a remoção da matéria orgânica do lixiviado seria devida à biodegradação ou à simples diluição no esgoto sanitário. Para responder esse questionamento, propôs-se o método tentativo \"equivalente em ácido húmico\" (Eq.AH). Em ensaios com reatores de lodos ativados (10 L) operados em batelada, avaliaram-se as remoções de matéria orgânica e nitrogênio para diferentes misturas de lixiviado e esgoto sanitários brutos e pré-tratados, com proporções volumétricas de lixiviado de 0, 0,2, 2 e 5%. O tratamento foi mais eficiente para a mistura esgoto bruto e lixiviado pré-tratado por air stripping (para remoção da amônia) na proporção volumétrica de 2%. Essa condição foi avaliada em reatores piloto de lodos ativados (95 L) e biofiltro aerado submerso (178 L), alimentados continuamente com tempo de detenção hidráulica (TDH) de 24 h. O reator piloto de lodos ativados removeu 59% do COD e a eficiência de nitrificação foi de 60%; enquanto que o biofiltro removeu 83% do COD e eficiência de nitrificação foi de 77%. Com o método tentativo Eq.AH, verificou-se que a remoção da matéria orgânica do lixiviado pré-tratado se deu por biodegradação parcial com o esgoto sanitário, resultado confirmado por espectroscopia de infravermelho por transformada de Fourier. As remoções do COD Eq.AH nos reatores piloto de lodos ativados e biofiltro aerado submerso foram de, respectivamente, 47 e 71%. Adicionalmente, o monitoramento da remoção da matéria orgânica pôde ser realizado com eficácia pelo teste de coloração com nanquim, utilizando o método de classificação de tonalidades proposto nesta Tese. A segunda alternativa proposta nesta Tese consistiu no tratamento dos lixiviados bruto e pré-tratado com cal em reatores de lodos ativados. Os resultados, todavia, foram insatisfatórios: indicaram que essa alternativa se mostrou inviável: após 20 dias de aeração nos reatores de bancada alimentados em batelada, a remoção da matéria orgânica foi inferior a 40% e a remoção do nitrogênio foi devida à volatilização da amônia. / This thesis was dedicated to two alternatives for landfill leachate treatment. The first one, the aerobic co-treatment of leachate and domestic wastewater in aerobic systems, aimed to verify if the organic matter of leachate was removed by biodegradation or dilution with domestic wastewater. To answer this questioning, it was proposed the tentative method \"equivalent in humic acid\" (Eq.HA). In the experiments with bench-scale activated sludge reactors (10 L) operated in batch mode, it was evaluated the organic matter and nitrogen removal from mixtures containing raw and pre-treated leachate and domestic wastewater, at the volumetric ratios of 0, 0.2, 2 and 5%. The treatment was mostly efficient when it was used the mixture domestic wastewater and leachate pre-treated by air stripping (for ammonia removal), at a volumetric ratio of 2%. This condition was also evaluated in a pilot-scale activated sludge reactor (95 L) and a submerged aerobic biofilter (178 L), operated under continuous-flow regime with a 24-h hydraulic retention time. The pilot-scale activated sludge reactor removed 59% of DOC and nitrification efficiency was 60%; whereas the submerged aerobic biofilter removed 83% of DOC and nitrification efficiency was 77%. Using the Eq.HA approach, it was determined that pre-treated leachate organic matter removal was due to partial biodegradation with domestic wastewater, which was confirmed by Fourier transform infrared spectroscopy. The removals of COD Eq.HA were 47% for the pilot-scale activated sludge reactor and 71% for the submerged aerobic biofilter. Aditionally, organic matter could be assessed with the India ink reverse stain test, using the proposed method for tonalities classification. The second alternative proposed by this Thesis consisted in the treatment of raw and pre-treated leachate by lime addition, using activated sludge reactors. The results did not indicate the feasibility of this alternative: after 20 days of aeration, the organic matter removal was lesser than 40%, and nitrogen was mostly removed by ammonia volatilization.
|
Page generated in 0.0727 seconds