• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 13
  • 11
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desempenho de um reator para compostagem descentralizada de lixo orgânico domiciliar e grau de maturação do composto / Performance of a reactor for decentralized composting of organic waste at home and degree of maturation of the compound

Rodrigo Sondermann Muniz 31 March 2010 (has links)
Nas últimas décadas, a disposição final de lixo tornou-se um sério problema a ser enfrentado por todos os países, em função da escassez crescente de terrenos disponíveis para aterros sanitários e distância cada vez maior dos centros geradores e a disposição final, assim como do aumento substancial da geração per capita. A acumulação de lixo nos grandes centros populacionais estimula a proliferação de macro e microvetores (ratos, baratas, moscas, vírus, bactérias, parasitos) e conseqüentemente, a disseminação de doenças. Em particular, com relação ao lixo gerado em ilhas e comunidades isoladas, é de alta relevância estratégias baseadas na descentralização do tratamento da fração orgânica de lixo domiciliar, com fim do transporte através de barcas para o continente, gerando mau cheiro e riscos de poluição ambiental. O presente projeto teve por objetivo: Testar o mesmo reator de compostagem descentralizada sob condições do verão sueco, alimentando-o com resíduos de restaurantes da cidade costeira Kalmar e sob condições brasileiras, alimentando-o com resíduos de cozinha da escola municipal de Abraão-Ilha Grande, RJ; propor modificações mecânicas e/ou operacionais para otimização dos processos; avaliar a qualidade e o grau de maturação do composto de diferentes fases através do método respirométrico Specific Oxygen Uptake Rate (SOUR)o método respirométrico NBR 14283 da ABNT. Em resumo, concluiu-se que a composição do lixo e pH inicial do material estruturante adicionado são fatores determinantes do tempo requerido para degradação dos ácidos orgânicos gerados e subseqüente elevação do pH; dependendo das características dos resíduos orgânicos, é necessária a inclusão de inoculante (ex: composto) para melhor desenvolvimento de bactérias e fungos e, conseqüentemente, otimização do processo; as análises físico-químicas e microbiológicas confirmaram que o processo de degradação aeróbia ocorre no interior do corpo principal do reator e que a qualidade do composto gerado é satisfatória; entretanto, melhorias consideráveis no sistema de trituração e alimentação são requeridas para que o reator testado possa se usado em sua capacidade plena. Os testes respirométrico atráves do Specific Oxygen Uptake Rate(SOUR) e da norma NBR 14283 da ABNT mostraram-se ambos eficazes na identificação do grau de maturação do composto e do avanço do processo de compostagem. Uma vez removidos os problemas mecânicos de trituração e alimentação, o reator testado poderá ser utilizado como uma tecnologia inovadora do tratamento de lixo orgânico in situ para pequenos e médios geradores de lixo orgânico domiciliar. / In recent decades, the disposal of biodegradable solid waste has become a serious problem to be faced by all countries, due to the increasing scarcity of available land for landfills and increasing distance from generation centers, as well as the substantial increase in total solid waste generated per capita. The accumulation of solid waste in highly populated areas stimulates the dissemination of vectors (rates, cucarachas, flies, virus, bacteria, and parasites) and, consequently spreading of diseases. Regarding the solid waste generated in islands and isolated communities, decentralized strategies for treatment of organic fraction, reducing transportation and impacts related to that is very convenient. This study had the following main objectives: to test the same reactor for decentralized composting during the Swedish summer using organic waste from restaurants at the coast, in Kalmar, Sweden, and under Brazilian conditions, using organic waste from the kitchen of the municipal primary school at Abraão, Ilha Grande, RJ; to evaluate and propose mechanical and operational changes in the reactor for process optimization; to assess the quality and degree of maturation of the compost at different stages of composting through two respirometry methods, the Specific Oxygen Uptake Rate (SOUR) and the ABNT norm NBR 14283. In short, it was concluded that the solid waste composition and initial pH of the material used as amendment are important factors to determine the time required for degradation of the organic acids produced and subsequent pH increase; depending on the organic waste characteristics, it is necessary to use material for augmentation (ex: compost) to improve the development of microorganisms and consequently, optimization of the process; the physic-chemical and microbiological analyses confirmed that the aerobic degradation occurred inside the reactor and that the quality of the produced compost is satisfactory; however, considerable improvements in the shredding and feeding system is required in order to test the reactors performance in its full-capacity. The respirometric tests carried out using the specific oxygen uptake ra(SOUR) method and the NBR 14283 norm, were effective in indicating the maturity of the compost and the degree of progress in the composting process. Once the mechanical problems in the shredding and feeding system are solved, the reactor might be useful as an innovative technology for treatment of organic waste in situ for small and medium generators.
2

Efeito da redução do diâmetro interno sobre o desempenho de um reator aeróbio de leito fluidizado no tratamento de esgoto sanitário

Rufato, Fernando Henrique [UNESP] 01 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:45Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-01Bitstream added on 2014-06-13T18:52:38Z : No. of bitstreams: 1 rufato_fh_me_ilha_prot.pdf: 2126468 bytes, checksum: 13fba6f1aeeaac0b8746344e57849eac (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os reatores de leito fluidizado com circulação em tubos concêntricos têm apresentado bons resultados no tratamento de esgoto sanitário, conforme uma série de relatos da bibliografia. Entretanto, o estado atual da modelagem não oferece ferramentas consolidadas para o projeto dos reatores deste tipo, devido à complexidade do funcionamento do leito trifásico e sua interdependência com os parâmetros biológicos envolvidos. Nesse contexto, a presente pesquisa teve por objetivo caracterizar experimentalmente os efeitos da redução do diâmetro interno sobre o funcionamento de um reator de 6 metros de altura, por meio de estudos hidrodinâmicos e análises laboratoriais do esgoto afluente e efluente. O reator tem diâmetro externo de 0,25m e foi operado anteriormente com um tubo interno de 0,20m de diâmetro, o qual foi reduzido para 0,10m neste trabalho. Antes de iniciar o tratamento foram medidas as velocidades de circulação por meio de injeção de traçadores e foram determinados os coeficientes de transferência de oxigênio. O tratamento do esgoto sanitário, submetido a gradeamento prévio, foi realizado com TDH de 3 horas e concentração de meio suporte de 100g/L de areia com diâmetro médio de 0,26mm. Os resultados indicaram que a redução do diâmetro interno provocou aumento expressivo da velocidade do líquido no tubo de subida. Com isso foi possível utilizar vazões de ar tão baixas quanto 1500L/h sem risco de instabilizar o leito, enquanto que na situação anterior eram necessários cerca de 3700L/h. O processo de tratamento foi o fator limitante da vazão de ar, requerendo cerca de 2100L/h. As remoções médias de DQO, DBO e NTK situaram-se em 91,1%, 88,5% e 88,8%, respectivamente. Com o diâmetro interno de 0,20m foram obtidas, em condições de operação semelhantes, remoções de 81,7%, 88,6% e 87,0%, com uma vazão de ar de 3700L/h. Com o tubo interno de 0,10m o reator apresentou bom desempenho hidrodinâmico,... / The circulating fluidized bed reactors with concentric tubes have been presented good results in the treatment of domestic wastewater, as shown by several reports in the literature. However, the current state of the art of modeling does not offer consolidated design tools to this kind of reactors, due to the complexities of the three-phase bed behavior and their interdependence with the biological parameters involved. In this context, the objective of this research is to experimentally characterize the effect of the internal diameter reduction on the functioning of a reactor with 6 meters of height, by means of hydrodynamic studies and laboratorial analyses of the reactor’s affluent and effluent. The reactor has an external diameter of 0,25m and an internal tube with a previous diameter of 0,25m, reduced to 0,10m in this work. Before initiating the treatment the circulation velocities were measured by injecting tracers and the oxygen transfer coefficients were determined. The treatment of the previously screened wastewater was carried out with Hydraulic Detention Times (HDT) of 3 hours The solid phase (carrier particles) used was 100g/L of sand with 0,26mm of average diameter. The results indicated that the reduction of the internal diameter greatly increased the liquid’s velocity in the riser. Thus it was possible to use air injection taxes as low as 1500L/h without risk of bed settlement, while in previous situations it was necessary about 3700L/h. The air flux of about 2100L/h required by the treatment process was the restraining factor to the diminution of the air injection flux. The averaged removals of DQO, DBO, and TKN were respectively 91,1%, 88.5% and 88.8%. With the internal diameter of 0,20m in similar conditions there were obtained removals of 81,7%, 88.6% and 87.0%, with an air injection flux of 3700L/h. With the internal tube of 0,10m the reactor presented good hydrodynamic performance, also improving the settling ...
3

Influência da relação entre diâmetros no comportamento hidrodinâmico de reatores aeróbios de leito fluidizado com circulação em tubos concêntricos

Araújo, Leandro Santos de [UNESP] 28 November 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-11-28Bitstream added on 2014-06-13T18:38:59Z : No. of bitstreams: 1 araujo_ls_me_ilha.pdf: 2918640 bytes, checksum: 77955c3e7abab641549a8794e03fecfb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O reator aeróbio de leito fluidizado com circulação apresenta características que permitem efetuar o tratamento em apenas uma etapa. O uso deste reator torna-se atraente devido à possibilidade de mantê-lo com uma alta concentração de biomassa ativa, propiciando seu porte compacto, conseqüência do reduzido período de detenção hidráulica. A eficiência do biofilme no tratamento depende das condições hidrodinâmicas do reator, uma vez que sua espessura pode ser alterada de acordo com a velocidade de circulação, e a transferência de oxigênio através de suas camadas depende da vazão de ar injetada no sistema. O trabalho propôs-se a investigar a influência da relação entre diâmetros dos tubos concêntricos em quatro configurações, mantendo o diâmetro externo constante e igual a 250 mm e alterando o diâmetro interno entre 100, 125, 150 e 200 mm, proporcionando relações Ae/Ai iguais a 5,25; 3,00; 1,78 e; 0,56, respectivamente. O tubo interno possui 2,22 m e é posicionado 0,05m acima do fundo do reator. A altura estática da coluna de fluido foi 2,35 m. Os ensaios hidrodinâmicos – velocidade do líquido, fração volumétrica de ar, tempo de mistura – e os de transferência de oxigênio foram realizados para vazões de ar até 2500 l/h em meio bifásico e em meio trifásico com concentrações de areia iguais a 30, 70, 100 e 150 g/l. O diâmetro interno de 125 mm foi o mais eficiente na indução de velocidade de circulação do líquido. A fração volumétrica de ar aumentou com o aumento do diâmetro interno para mesmas velocidades superficiais de ar, com exceção do menor diâmetro, o qual apresentou comportamento diferenciado dos demais. Os reator com diâmetro interno de 150 mm apresentou maiores valores de KLa para as mesmas vazões de ar. Observou-se que a adição de sólidos causou um decréscimo da velocidade do líquido e da fração... / Aerobic internal-loop airlift reactor has some characteristics that allow wastewater treatment in a single stage. The attractive to use this kind of reactor is mainly because of its capacity of maintaining a high active biomass concentration into it, which induces its small structure, in a consequence of its small hydraulic detention time. The biofilm efficiency in the treatment depends on reactor’s hydrodynamic conditions. The structure of the biofilm and the oxygen transfer into its layers is affected by the liquid velocity induced by the air flow rate. This work proposed an investigation about the influence of the diameter of the concentric tubes, using four geometric configurations. The model had a 250 mm external tube and the inner draft tube with diameters of 100, 125, 150 and 200 mm, which means AD/AR equals to 5.25, 3.00, 1.78 and 0.56, respectively. The draft tube’s height was 2,22 m and was positioned 0,05 m above the bottom of the reactor. The static fluid height was 2,35 m. The hydrodynamic tests – liquid velocities, gas hold up, mixture time – and the oxygen transfer tests were conducted for two and three-phase systems, with variable air flow rate up to 2500 l/h. The solid phase concentrations used were 30, 70, 100 and 150 g/l. The 125 mm reactor was the most efficient in inducing the liquid circulation velocity. The gas hold up increased with the increasing of the draft tube diameter, for same superficial gas velocities, excepting the 100 mm, which showed a different behavior. The 150 mm reactor presented the highest values for KLa for the same air rate. It was noticed that the solids addiction decreased the liquid velocity, gas hold up and oxygen transfer. Hydrodynamics equations found in literature showed a limited applicability, evidencing the necessity of relations capable to reach the most different configuration for this kind of reactor. A mass transfer mathematic...(Complete abstract click electronic acces below)
4

Efeito da concentração do meio suporte e relação entre áreas no desempenho de reatores aeróbios de leito fluidizado com circulação interna no tratamento de esgoto doméstico

Correia, Gleyce Teixeira [UNESP] 01 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-01Bitstream added on 2014-06-13T20:19:09Z : No. of bitstreams: 1 correia_gt_me_ilha.pdf: 1747896 bytes, checksum: 7eb0e6d783d9d9c4b844592ae152c89a (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O reator aeróbio de leito fluidizado com circulação interna emprega microorganismos aderidos a um meio suporte uniforme (areia), removendo tanto matéria orgânica quanto nitrogenada. Neste experimento foram estudados dois reatores com 2,6 m de altura cuja diferença era o diâmetro do tubo interno (125 e 150 mm) e foram aplicadas diferentes concentrações de meio suporte ao longo do estudo (100, 125 e 150 g.L-1). Ensaios realizados com água limpa utilizando traçador (NaCl) e sondas de condutividade elétrica mostraram que, nas vazões de ar entre 1500 – 3000 L.h-1, ocorre circulação suficiente para a suspensão do meio suporte. O esgoto doméstico passou por peneiramento estático e foram realizadas análises de DBO, DQO, NT, Namon, NO2, NO3, sólidos, espessura do biofilme, turbidez, temperatura, pH, OD e testes microbiológicos (Gram, esporos e catalase). Observou-se que a adição de meio suporte influencia positivamente na eficiência de remoção de matéria nitrogenada, e que uma menor diferença entre as áreas interna e externa facilitam o equilíbrio do sistema, apresentando assim, eficiências melhores. / Aerobic fluidized bed reactor with internal-loop uses microorganisms attached to a uniform carrier (sand), removing carbonaceous and nitrogenous matter. In this experimental work two reactors with 2,6 m height were studied. The main difference between both reactors was the inner tube diameter (125 and 150mm). Different carrier concentrations were applied in that study (100, 125 and 150g.L-1). Experiments with clean water using a marker (NaCl) and electrical conductivity probes showed that with flow taxes between 1500 – 3000 L.h-1 occurs sufficient circulation to suspend the carrier. The sewage passed by static screening and analyses of BOD, COD, total nitrogen, Namon, NO2, NO3, suspend solids, biofilm thickness, turbidity, temperature, pH, dissolved oxygen and microbiological test (Gram, spores and catalysis) were realized. In that work, was observed that the addition of carrier has positive influences on nitrogenous matter removal efficiency, and lower differences between indoor/outdoor area facilitate system balance, showing better efficiencies.
5

Efeito da redução do diâmetro interno sobre o desempenho de um reator aeróbio de leito fluidizado no tratamento de esgoto sanitário /

Rufato, Fernando Henrique. January 2005 (has links)
Orientador: Milton Dall'Aglio Sobrinho / Banca: Tsunao Matsumoto / Banca: Pedro Alem Sobrinho / Resumo: Os reatores de leito fluidizado com circulação em tubos concêntricos têm apresentado bons resultados no tratamento de esgoto sanitário, conforme uma série de relatos da bibliografia. Entretanto, o estado atual da modelagem não oferece ferramentas consolidadas para o projeto dos reatores deste tipo, devido à complexidade do funcionamento do leito trifásico e sua interdependência com os parâmetros biológicos envolvidos. Nesse contexto, a presente pesquisa teve por objetivo caracterizar experimentalmente os efeitos da redução do diâmetro interno sobre o funcionamento de um reator de 6 metros de altura, por meio de estudos hidrodinâmicos e análises laboratoriais do esgoto afluente e efluente. O reator tem diâmetro externo de 0,25m e foi operado anteriormente com um tubo interno de 0,20m de diâmetro, o qual foi reduzido para 0,10m neste trabalho. Antes de iniciar o tratamento foram medidas as velocidades de circulação por meio de injeção de traçadores e foram determinados os coeficientes de transferência de oxigênio. O tratamento do esgoto sanitário, submetido a gradeamento prévio, foi realizado com TDH de 3 horas e concentração de meio suporte de 100g/L de areia com diâmetro médio de 0,26mm. Os resultados indicaram que a redução do diâmetro interno provocou aumento expressivo da velocidade do líquido no tubo de subida. Com isso foi possível utilizar vazões de ar tão baixas quanto 1500L/h sem risco de instabilizar o leito, enquanto que na situação anterior eram necessários cerca de 3700L/h. O processo de tratamento foi o fator limitante da vazão de ar, requerendo cerca de 2100L/h. As remoções médias de DQO, DBO e NTK situaram-se em 91,1%, 88,5% e 88,8%, respectivamente. Com o diâmetro interno de 0,20m foram obtidas, em condições de operação semelhantes, remoções de 81,7%, 88,6% e 87,0%, com uma vazão de ar de 3700L/h. Com o tubo interno de 0,10m o reator apresentou bom desempenho hidrodinâmico, ... / Abstract: The circulating fluidized bed reactors with concentric tubes have been presented good results in the treatment of domestic wastewater, as shown by several reports in the literature. However, the current state of the art of modeling does not offer consolidated design tools to this kind of reactors, due to the complexities of the three-phase bed behavior and their interdependence with the biological parameters involved. In this context, the objective of this research is to experimentally characterize the effect of the internal diameter reduction on the functioning of a reactor with 6 meters of height, by means of hydrodynamic studies and laboratorial analyses of the reactor's affluent and effluent. The reactor has an external diameter of 0,25m and an internal tube with a previous diameter of 0,25m, reduced to 0,10m in this work. Before initiating the treatment the circulation velocities were measured by injecting tracers and the oxygen transfer coefficients were determined. The treatment of the previously screened wastewater was carried out with Hydraulic Detention Times (HDT) of 3 hours The solid phase (carrier particles) used was 100g/L of sand with 0,26mm of average diameter. The results indicated that the reduction of the internal diameter greatly increased the liquid's velocity in the riser. Thus it was possible to use air injection taxes as low as 1500L/h without risk of bed settlement, while in previous situations it was necessary about 3700L/h. The air flux of about 2100L/h required by the treatment process was the restraining factor to the diminution of the air injection flux. The averaged removals of DQO, DBO, and TKN were respectively 91,1%, 88.5% and 88.8%. With the internal diameter of 0,20m in similar conditions there were obtained removals of 81,7%, 88.6% and 87.0%, with an air injection flux of 3700L/h. With the internal tube of 0,10m the reactor presented good hydrodynamic performance, also improving the settling ... / Mestre
6

Desempenho de um reator para compostagem descentralizada de lixo orgânico domiciliar e grau de maturação do composto / Performance of a reactor for decentralized composting of organic waste at home and degree of maturation of the compound

Rodrigo Sondermann Muniz 31 March 2010 (has links)
Nas últimas décadas, a disposição final de lixo tornou-se um sério problema a ser enfrentado por todos os países, em função da escassez crescente de terrenos disponíveis para aterros sanitários e distância cada vez maior dos centros geradores e a disposição final, assim como do aumento substancial da geração per capita. A acumulação de lixo nos grandes centros populacionais estimula a proliferação de macro e microvetores (ratos, baratas, moscas, vírus, bactérias, parasitos) e conseqüentemente, a disseminação de doenças. Em particular, com relação ao lixo gerado em ilhas e comunidades isoladas, é de alta relevância estratégias baseadas na descentralização do tratamento da fração orgânica de lixo domiciliar, com fim do transporte através de barcas para o continente, gerando mau cheiro e riscos de poluição ambiental. O presente projeto teve por objetivo: Testar o mesmo reator de compostagem descentralizada sob condições do verão sueco, alimentando-o com resíduos de restaurantes da cidade costeira Kalmar e sob condições brasileiras, alimentando-o com resíduos de cozinha da escola municipal de Abraão-Ilha Grande, RJ; propor modificações mecânicas e/ou operacionais para otimização dos processos; avaliar a qualidade e o grau de maturação do composto de diferentes fases através do método respirométrico Specific Oxygen Uptake Rate (SOUR)o método respirométrico NBR 14283 da ABNT. Em resumo, concluiu-se que a composição do lixo e pH inicial do material estruturante adicionado são fatores determinantes do tempo requerido para degradação dos ácidos orgânicos gerados e subseqüente elevação do pH; dependendo das características dos resíduos orgânicos, é necessária a inclusão de inoculante (ex: composto) para melhor desenvolvimento de bactérias e fungos e, conseqüentemente, otimização do processo; as análises físico-químicas e microbiológicas confirmaram que o processo de degradação aeróbia ocorre no interior do corpo principal do reator e que a qualidade do composto gerado é satisfatória; entretanto, melhorias consideráveis no sistema de trituração e alimentação são requeridas para que o reator testado possa se usado em sua capacidade plena. Os testes respirométrico atráves do Specific Oxygen Uptake Rate(SOUR) e da norma NBR 14283 da ABNT mostraram-se ambos eficazes na identificação do grau de maturação do composto e do avanço do processo de compostagem. Uma vez removidos os problemas mecânicos de trituração e alimentação, o reator testado poderá ser utilizado como uma tecnologia inovadora do tratamento de lixo orgânico in situ para pequenos e médios geradores de lixo orgânico domiciliar. / In recent decades, the disposal of biodegradable solid waste has become a serious problem to be faced by all countries, due to the increasing scarcity of available land for landfills and increasing distance from generation centers, as well as the substantial increase in total solid waste generated per capita. The accumulation of solid waste in highly populated areas stimulates the dissemination of vectors (rates, cucarachas, flies, virus, bacteria, and parasites) and, consequently spreading of diseases. Regarding the solid waste generated in islands and isolated communities, decentralized strategies for treatment of organic fraction, reducing transportation and impacts related to that is very convenient. This study had the following main objectives: to test the same reactor for decentralized composting during the Swedish summer using organic waste from restaurants at the coast, in Kalmar, Sweden, and under Brazilian conditions, using organic waste from the kitchen of the municipal primary school at Abraão, Ilha Grande, RJ; to evaluate and propose mechanical and operational changes in the reactor for process optimization; to assess the quality and degree of maturation of the compost at different stages of composting through two respirometry methods, the Specific Oxygen Uptake Rate (SOUR) and the ABNT norm NBR 14283. In short, it was concluded that the solid waste composition and initial pH of the material used as amendment are important factors to determine the time required for degradation of the organic acids produced and subsequent pH increase; depending on the organic waste characteristics, it is necessary to use material for augmentation (ex: compost) to improve the development of microorganisms and consequently, optimization of the process; the physic-chemical and microbiological analyses confirmed that the aerobic degradation occurred inside the reactor and that the quality of the produced compost is satisfactory; however, considerable improvements in the shredding and feeding system is required in order to test the reactors performance in its full-capacity. The respirometric tests carried out using the specific oxygen uptake ra(SOUR) method and the NBR 14283 norm, were effective in indicating the maturity of the compost and the degree of progress in the composting process. Once the mechanical problems in the shredding and feeding system are solved, the reactor might be useful as an innovative technology for treatment of organic waste in situ for small and medium generators.
7

Influência da relação entre diâmetros no comportamento hidrodinâmico de reatores aeróbios de leito fluidizado com circulação em tubos concêntricos /

Araújo, Leandro Santos de. January 2008 (has links)
Orientador: Milton Dall'Aglio Sobrinho / Banca: Tsunao Matsumoto / Banca: Gilson Arimura Arima / Resumo: O reator aeróbio de leito fluidizado com circulação apresenta características que permitem efetuar o tratamento em apenas uma etapa. O uso deste reator torna-se atraente devido à possibilidade de mantê-lo com uma alta concentração de biomassa ativa, propiciando seu porte compacto, conseqüência do reduzido período de detenção hidráulica. A eficiência do biofilme no tratamento depende das condições hidrodinâmicas do reator, uma vez que sua espessura pode ser alterada de acordo com a velocidade de circulação, e a transferência de oxigênio através de suas camadas depende da vazão de ar injetada no sistema. O trabalho propôs-se a investigar a influência da relação entre diâmetros dos tubos concêntricos em quatro configurações, mantendo o diâmetro externo constante e igual a 250 mm e alterando o diâmetro interno entre 100, 125, 150 e 200 mm, proporcionando relações Ae/Ai iguais a 5,25; 3,00; 1,78 e; 0,56, respectivamente. O tubo interno possui 2,22 m e é posicionado 0,05m acima do fundo do reator. A altura estática da coluna de fluido foi 2,35 m. Os ensaios hidrodinâmicos - velocidade do líquido, fração volumétrica de ar, tempo de mistura - e os de transferência de oxigênio foram realizados para vazões de ar até 2500 l/h em meio bifásico e em meio trifásico com concentrações de areia iguais a 30, 70, 100 e 150 g/l. O diâmetro interno de 125 mm foi o mais eficiente na indução de velocidade de circulação do líquido. A fração volumétrica de ar aumentou com o aumento do diâmetro interno para mesmas velocidades superficiais de ar, com exceção do menor diâmetro, o qual apresentou comportamento diferenciado dos demais. Os reator com diâmetro interno de 150 mm apresentou maiores valores de KLa para as mesmas vazões de ar. Observou-se que a adição de sólidos causou um decréscimo da velocidade do líquido e da fração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Aerobic internal-loop airlift reactor has some characteristics that allow wastewater treatment in a single stage. The attractive to use this kind of reactor is mainly because of its capacity of maintaining a high active biomass concentration into it, which induces its small structure, in a consequence of its small hydraulic detention time. The biofilm efficiency in the treatment depends on reactor's hydrodynamic conditions. The structure of the biofilm and the oxygen transfer into its layers is affected by the liquid velocity induced by the air flow rate. This work proposed an investigation about the influence of the diameter of the concentric tubes, using four geometric configurations. The model had a 250 mm external tube and the inner draft tube with diameters of 100, 125, 150 and 200 mm, which means AD/AR equals to 5.25, 3.00, 1.78 and 0.56, respectively. The draft tube's height was 2,22 m and was positioned 0,05 m above the bottom of the reactor. The static fluid height was 2,35 m. The hydrodynamic tests - liquid velocities, gas hold up, mixture time - and the oxygen transfer tests were conducted for two and three-phase systems, with variable air flow rate up to 2500 l/h. The solid phase concentrations used were 30, 70, 100 and 150 g/l. The 125 mm reactor was the most efficient in inducing the liquid circulation velocity. The gas hold up increased with the increasing of the draft tube diameter, for same superficial gas velocities, excepting the 100 mm, which showed a different behavior. The 150 mm reactor presented the highest values for KLa for the same air rate. It was noticed that the solids addiction decreased the liquid velocity, gas hold up and oxygen transfer. Hydrodynamics equations found in literature showed a limited applicability, evidencing the necessity of relations capable to reach the most different configuration for this kind of reactor. A mass transfer mathematic...(Complete abstract click electronic acces below) / Mestre
8

Análise dos parâmetros cinéticos no fenômeno da reoxigenação e desoxigenação da água / Analysis of the kinetics parameters in the phenomenon of reoxygenation and deoxygenation in water

Maia, Guilherme Del Nero 10 June 2003 (has links)
A reoxigenação de água residuária é tratada na literatura técnica de maneira análoga à reoxigenação na água limpa; os efeitos do consumo de oxigênio pela população bacteriana ativa são quantificados pela introdução dos parâmetros alfa e beta. Alfa corrige o coeficiente volumétrico de transferência de massa do oxigênio e beta corrige a concentração de saturação do oxigênio dissolvido na água. Com o presente estudo pretende-se tornar explícitos os parâmetros cinéticos envolvidos no processo, de modo a fornecer base conceitual para um melhor entendimento do fenômeno. A pesquisa é feita a partir de trabalho experimental, seguido de modelagem matemática conceitual. No entanto, no lugar dos microrganismos como sumidouro de oxigênio dissolvido foi utilizado o borbulhamento sub-superficial de gás nitrogênio, em processo de stripping. Um processo físico, portanto, substitui o processo bioquímico no papel de retirar o oxigênio dissolvido no seio líquido. O modelo matemático proposto ajustou-se bem aos dados experimentais, sendo que a sua validação pôde ser obtida através das análises estatísticas realizadas. / The reoxygenation in wastewater is seen in the technical literature in an analogous way as the reoxygenation of clean water. The effects of the oxygen consumed by active bacteria population are quantified with the introduction of the parameters alpha and beta. Alpha corrects for the volumetric mass transfer coefficient and beta corrects for the dissolved oxygen saturation concentration. The present research intends to make explicit the kinetic of the process, in order to supply conceptual support to a better understanding of the phenomenon. The research is done through experimental work, followed by conceptual, mathematical modeling. Stripping with nitrogen is used as an oxygen sink instead of microorganisms. Thus, a physical process replaces the biochemical process. The proposed mathematical model fitted well to the experimental data, and its validation could be obtained through the statistical analyses done.
9

Pós-tratamento de efluentes de reatores anaeróbios utilizando biofiltro aerado submerso / Anaerobic reactor effluent post-treatment using submerged aerated biofilter

Sitônio, Camila Pereira 14 September 2001 (has links)
O potencial de aplicação do biofiltro aerado submerso (BF) para pós-tratamento de efluentes de um reator anaeróbio compartimentado foi avaliado através de um experimento em escala de laboratório (bancada), visando adequar o efluente tratado aos padrões estabelecidos pela legislação ambiental. Estudou-se a remoção de matéria orgânica e sólidos suspensos no BF, e também a possibilidade de nitrificação no reator. O reator foi construído em coluna de acrílico com 1,30 m de altura, 100 mm de diâmetro e com volume útil de 7,2 L, sendo operado com tempo de detenção hidráulica de 5 horas. Como suporte de imobilização celular, utilizou-se matrizes cúbicas de espuma de poliuretano. Neste trabalho, são apresentados os principais resultados obtidos na operação contínua do reator BF, durante 93 dias consecutivos, divididos em duas fases, devido à variação da carga orgânica volumétrica aplicada (Fase I: 0,99 - 1,87 kg DQO/m3. dia; Fase II: 0,26 - 0,88kg DQO/m3. dia). Durante a fase I de operação, o BF alcançou eficiências médias de remoção de DQO e DBO5 da amostra bruta de 82 e 86%, respectivamente, e de conversão do nitrogênio amoniacal de 81%, com concentração média efluente de 7,5 mg N-amoniacal/L. Na fase final de operação, para remoções médias de 70% de DQOB e 57% de DBO5, o efluente produzido pelo BF apresentava concentrações médias de 30 mg DQOB e 21 mg DBO5/L. Entretanto, o processo de nitrificação nessa fase foi instável, com concentração média de efluente de 25,3 mg N-amoniacal/L. O BF produziu efluente clarificado alcançando valores médios de 3,46 e 2,58 mg/L para SST e SSV, para segunda fase de operação. Este efluente atendeu ao padrão de lançamento do Estado de São Paulo em 100% dos resultados de DBO5, durante todo o período experimental, apresentando bom desempenho na remoção de matéria orgânica, tanto para altas como para baixas cargas orgânicas volumétricas aplicadas. A espuma de poliuretano mostrou-se um suporte adequado para imobilização da biomassa aeróbia e remoção de sólidos suspensos, devida a sua grande capacidade de absorção. Constatou-se, portanto, que o emprego do biofiltro aerado submerso apresenta-se como uma alternativa vantajosa como pós-tratamento de efluentes de reatores anaeróbios, produzindo efluente com excelente quantidade e parcialmente nitrificado. / The potential of application of the submerged aerated biofilter (BF) for post-treatment of effluents of an anaerobic baffed reactor was evaIuated through an experiment on Iaboratory scale to adapt the treated effluent to the established quality standards required by the environmental legislation. The removal of organic matter and suspended solids in BF, and aIso the possibility of nitrification in the reactor were studied. The reactor was a column of acrylic with 1,30 m of height, 100 mm diameter and with a useful volume of 7,2 L, being operated with hydraulic detention time of 5 hours. As a support for celluIar immobilization, cubic matrices of polyurethane foam. In this work, the main results were obtained in the continuous operation of the BF reactor, for 93 consecutive days, divided in two phases due to the variation of the applied organic volumetric loading rate (phase I: 0,99-1,87 kg COD/m3.day; Phase II: 0,26-0,88 kg COD/m3.day). During phase I of the operation, BF reached average removal efficiencies of COD and BOD5 of the raw samples of 82 and 86%, respectively, and of conversion of the ammonia nitrogen of 81%, with average effluent concentration of 7,5 mg N-ammonia/L. In the final phase of operation, for removals of 70% of COD and 57% of BOD5, the effluent produced by BF presented average concentrations of 30 mg COD/L and 21 mg BOD5/L. However, the nitrification process in that phase was unstable, with effluent concentrations of 25,3 mg N-ammonia/L. BF produced a very clarified effluent reaching average values of 3,46 and 2,58 mg/L for SST and SSV, for the second operation phase. This effluent satisfied the qualify standards for its discharge in a stream in the State of São Paulo in 100% of the results of BOD5, during the whole experimental period, presenting good performance in the removaI of organic matter, for high as well as for low organic volumetric loading applied. The polyurethane foam demonstrate to be an appropriate support for immobilization of the aerobic biomass and removaI of suspended solids, due to its great absorption capacity. It was found that the employment of the submerged aerated biofilter offers as an advantageous aIternative as anaerobic eftluent post-treatment, producing effluent with excellent quality and partially nitrified.
10

Potencialidade da célula combustível microbiana para geração de energia elétrica a partir de esgoto sanitário / Potential microbial fuel cell to generate electricity from wastewater

Marcon, Lucas Ricardo Cardoso 25 March 2011 (has links)
O presente projeto avaliou uma célula combustível microbiana (CCM) composta de um reator combinado (anaeróbio e aeróbio), operada em fluxo contínuo com tempo de detenção hidráulico de 12 horas, alimentada com esgoto sintético (487 \'+ OU -\' 115 mg DQO/L) e esgoto sanitário (631 \'+ OU -\' 213 mg DQO/L). A estabilidade da CCM variou conforme as características do substrato aplicado. A eficiência de remoção de DQO ficou em 61 \'+ OU -\' 17; 67 \'+ OU -\' 26%, para esgoto sintético e sanitário respectivamente. Em média tensão obtida com o esgoto sintético foi de 76 mV com picos - 112,5 e 409 mV, enquanto que com o esgoto sanitário foi possível obter 52,1 mV na média e pico de geração em 325 mV. A potência variou de 10-150 mW/\'M POT.2\' com resistências entre 50-650 \'ômega\'. A geração de energia elétrica não apresentou relação linear com a DQO consumida em nenhum dos casos. A aplicação de barras de grafite como eletrodos se mostrou satisfatória na condução da corrente elétrica, o fator limitante foi a transferência de massa, principalmente a transferência de prótons do anodo para o catodo e a difusão de oxigênio para o anodo. Contudo os resultados obtidos demonstraram que é possível gerar eletricidade e, simultaneamente, tratar esgoto sanitário. / This project evaluated a microbial fuel cell (MFC) consisting of combined reactor (anaerobic and aerobic), operated in continuous flow with hydraulic detention time of 12 hours, fed with synthetic wastewater (487 \'+ OR -\' 115 mg COD/L) and wastewater (631 \'+ OR -\' 213 mg COD/L). The stability of the CCM varied according to the characteristics of the substrate applied. The efficiency of COD removal was at 61 \'+ OR -\' 17; 67 \'+ OR -\' 26 for synthetic wastewater and sawage respectively. On a average voltage obtained with synthetic wastewater was 76 mV with peaks - 112.5 and 409 mV, while the wastewater was obtained 52.1 mV on average peaks generation at 325 power was varied from 10-150 mW/\'M POT.2\' with resistances between 50-650 \'ômega\'. The power generation showed no liner relationship with the COD consumed in any case. The application of graphite rods as electrodes were satisfactory in the conduction of electrical of protons from the anode to the cathode and the diffusion of oxygen to the anode. However the results showed that it is possible to generate electricity while simultaneously treating sewage.

Page generated in 0.4389 seconds