Modelagem, Controle e avaliação de desempenho de restaurador dinâmico de tensão

SOUZA JUNIOR, Roberto Carlos de 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:36:14Z (GMT). No. of bitstreams: 2 arquivo2561_1.pdf: 2780969 bytes, checksum: 6db63775fe8c3a06f9aa836ed7dc2d8c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Neste trabalho são abordadas as topologias básicas do Restaurador Dinâmico de Tensão (DVR), um compensador série empregado para a mitigação de afundamentos momentâneos de tensão equilibrados ou desequilibrados, podendo também compensar harmônicos de tensão da rede. É descrito cada um de seus componentes e seu funcionamento, assim como as características deste compensador série. Também é desenvolvida a modelagem e estudos de sua topologia utilizando um inversor de quatro braços, com o intuito de possibilitar a compensação de componentes de sequência zero. Propõe-se um algoritmo simplificado de modulação por largura de pulso (PWM), que apresentou excelentes resultados. Um algoritmo de simulação digital detalhado, representando todos os principais componentes DVR, é desenvolvido em MATLAB/Simulink. Dessa forma, avalia-se o desempenho das topologias estudadas, assim como algumas vantagens e desvantagens das mesmas
2

Topologia para Restaurador Dinâmico de Tensão de Baixo Custo

BRITO, Márcio Evaristo da Cruz 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:38:19Z (GMT). No. of bitstreams: 2 arquivo6377_1.pdf: 2107854 bytes, checksum: 8bd2c5984bbc4c3898686257c332c3c8 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Este trabalho apresenta uma topologia alternativa para a implementação de um restaurador dinâmico de tensão (DVR) de baixo custo. A topologia proposta possui várias características interessantes, tais como a ausência de harmônicos durante a operação em regime permanente, redução das perdas por chaveamento, dispensa o uso de grandes capacitores, não utiliza etapa CC e não exige um controle sofisticado. Adicionalmente, a topologia proposta pode ser dimensionada de acordo com as exigências do projeto onde o DVR será utilizado, proporcionando acoplamento entre os recursos utilizados e os requisitos de custo e desempenho exigidos pela aplicação. Durante o desenvolvimento deste trabalho, a topologia proposta foi modelada digitalmente utilizando-se o software MATLAB, para avaliação de seu desempenho em relação às topologias tradicionais. Foi realizado um estudo comparativo de custos do DVR tradicional, em relação ao proposto, o que evidenciou uma vantagem expressiva a favor da topologia proposta. A construção do protótipo permitiu a obtenção de dados que corroboram os resultados obtidos nas simulações, evidenciando a aplicabilidade da proposta, o que a torna interessante para utilização em sistemas de distribuição onde o fator custo é quase sempre imperativo
3

Afundamentos de tensão em consumidores industriais : uma análise baseada no fator de impacto e na severidade dos eventos considerando os efeitos de faltas elétricas em sistemas de potência

Oliveira, Roger Alves de January 2018 (has links)
The present work deals with a comparative analysis of IEEE 1564 standardization and Module 8 of Distribution Procedures of the Brazilian Agency of Electrical Regulation, within the scope of voltage sags. For such comparison, a case study of monitoring is performed on an industrial consumer sensitive to the disturbance during 24 months. Additionally, since the main causes of the voltage sags are the electrical faults of the system to which the industry is inserted, the relations between both events are analyzed. From the simultaneity of these contingencies, a unique set of data was obtained through MATLAB R , which allowed the clustering of variables with K-means algorithm through WEKA software. Simultaneous events were also convenient for the validation of a simulation model in ANAFAS software. The results obtained with the application of such methodology allowed to know the impact of the events, to analyze the vulnerability area, to propose mitigations in the power system under study, as well as to validate a simulation model of sags with relative error less than 10 % to more than 70 % of cases.
4

Estimativa de indicadores de afundamentos de tensão em sistemas de distribuição de energia elétrica

Telles, Priscila January 2017 (has links)
Os afundamentos de tensão são distúrbios que afetam grandemente a qualidade da energia fornecida aos consumidores, se mostrando especialmente danosos para os consumidores industriais que dependem de tensões em níveis adequados para a continuidade de seus processos de fabricação. O desempenho das redes elétricas frente aos afundamentos de tensão é usualmente mensurado através de indicadores, que dentre outros propósitos, fornecem as informações necessárias ao planejamento de ações voltadas à mitigação dos efeitos dos afundamentos de tensão causados por faltas. Em geral, as regiões da rede vulneráveis a este tipo de distúrbio são identificadas através de medições em pontos de interesse ao longo da rede. No entanto, esta abordagem se mostra restritiva, pois abrange áreas pontuais e intervalos de tempo pouco representativos. Neste contexto, o presente trabalho propõe uma metodologia para estimar os indicadores de afundamentos de tensão, utilizando medições em um único terminal da rede. A técnica é baseada na determinação da localização das faltas para estimar as magnitudes dos afundamentos em todos os nós da rede. Estas informações são utilizadas para caracterizar o desempenho dos sistemas de distribuição em relação aos afundamentos de tensão que ocorrem em um dado período de estudo. A validação da metodologia foi efetuada a partir de simulações de faltas nos sistemas testes IEEE 13 nós e 34 nós. Os testes incluem a análise da sensibilidade da técnica frente a variações no carregamento da rede, considerando diversos cenários de faltas. / Voltage sags are disturbances that greatly affect the power quality supplied to customers and are especially damaging to industrial customers which rely on adequate voltage levels for the continuity of manufacturing processes. Electrical networks’ performance against voltage sags is usually measured by indices that among other purposes, provide the necessary information for planning actions aiming to mitigate the effects of voltage sags caused by faults. In general, areas vulnerable to this type of disturbance are identified by measurements at points of interest along the network. However, this approach is restrictive, since it covers punctual areas and reduced time intervals. In this context, this work proposes a methodology for estimating voltage sags indices using measurements at a single terminal. The technique is based on the fault location to estimate the magnitudes of voltage sags in all network nodes. This information is used to evaluate the performance of distribution systems in relation to the occurrence of voltage sags in a given period of study. The method’s validation was performed by fault simulations in the IEEE 13 node and 34 node test systems. The tests include a sensitivity analysis considering load variation and several fault scenarios.
5

Estimativa de indicadores de afundamentos de tensão em sistemas de distribuição de energia elétrica

Telles, Priscila January 2017 (has links)
Os afundamentos de tensão são distúrbios que afetam grandemente a qualidade da energia fornecida aos consumidores, se mostrando especialmente danosos para os consumidores industriais que dependem de tensões em níveis adequados para a continuidade de seus processos de fabricação. O desempenho das redes elétricas frente aos afundamentos de tensão é usualmente mensurado através de indicadores, que dentre outros propósitos, fornecem as informações necessárias ao planejamento de ações voltadas à mitigação dos efeitos dos afundamentos de tensão causados por faltas. Em geral, as regiões da rede vulneráveis a este tipo de distúrbio são identificadas através de medições em pontos de interesse ao longo da rede. No entanto, esta abordagem se mostra restritiva, pois abrange áreas pontuais e intervalos de tempo pouco representativos. Neste contexto, o presente trabalho propõe uma metodologia para estimar os indicadores de afundamentos de tensão, utilizando medições em um único terminal da rede. A técnica é baseada na determinação da localização das faltas para estimar as magnitudes dos afundamentos em todos os nós da rede. Estas informações são utilizadas para caracterizar o desempenho dos sistemas de distribuição em relação aos afundamentos de tensão que ocorrem em um dado período de estudo. A validação da metodologia foi efetuada a partir de simulações de faltas nos sistemas testes IEEE 13 nós e 34 nós. Os testes incluem a análise da sensibilidade da técnica frente a variações no carregamento da rede, considerando diversos cenários de faltas. / Voltage sags are disturbances that greatly affect the power quality supplied to customers and are especially damaging to industrial customers which rely on adequate voltage levels for the continuity of manufacturing processes. Electrical networks’ performance against voltage sags is usually measured by indices that among other purposes, provide the necessary information for planning actions aiming to mitigate the effects of voltage sags caused by faults. In general, areas vulnerable to this type of disturbance are identified by measurements at points of interest along the network. However, this approach is restrictive, since it covers punctual areas and reduced time intervals. In this context, this work proposes a methodology for estimating voltage sags indices using measurements at a single terminal. The technique is based on the fault location to estimate the magnitudes of voltage sags in all network nodes. This information is used to evaluate the performance of distribution systems in relation to the occurrence of voltage sags in a given period of study. The method’s validation was performed by fault simulations in the IEEE 13 node and 34 node test systems. The tests include a sensitivity analysis considering load variation and several fault scenarios.
6

Estudo da influência da conexão e aterramento de transformadores trifásicos em variações de tensão de curta duração

Costa, Lucas Araujo da January 2018 (has links)
Sendo as interrupções, os afundamentos de tensão e as sobretensões distúrbios de Qualidade de Energia Elétrica (QEE) com potencial de grande impacto econômico, estudos que procuram alternativas de mitigação de seus efeitos ou prevenção de sua ocorrência têm sido amplamente realizados nas últimas décadas. Uma das metodologias de avaliação de sua ocorrência é realizada pela predição, que geralmente se concentra em simulações de faltas em parcelas de sistemas elétricos de potência. Nos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST), encontra-se a denominação geral de Variações de Tensão de Curta Duração (VTCD) para estes três tipos de distúrbios, os quais podem ser classificados tanto por sua magnitude quanto por sua duração. Nesse contexto, este trabalho avalia pela predição a influência exercida pela conexão e o aterramento do neutro de transformadores trifásicos nas quantidades de VTCD, especialmente de afundamentos de tensão, e no valor do índice Fator de Impacto (FI) do PRODIST, que são observados em um nó com conexão a um consumidor industrial Realizam-se estudos de caso sobre um sistema de potência simulado no software Alternative Transients Program (ATP), o qual possui dois transformadores em sua rede: um transformador da subestação e outro na entrada do nó do consumidor industrial. Consideram-se duas conexões possíveis para o transformador de entrada, e aplica-se uma resistência de aterramento para o neutro de ambos os transformadores em cada caso, alteram-se o seu valor. Verificam-se as tensões no nó do consumidor industrial de duas formas diferentes: tensões fase-terra e tensões fase-fase. Observa-se, assim, que há diferenças para estas quantidades e para o valor do FI devidas à forma de conexão do transformador de entrada, valor da resistência de aterramento de neutro de ambos os transformadores e formas de verificação das tensões. / Since interruptions, voltage sags and overvoltages are Power Quality (PQ) disturbances with great economic impact potential, studies that seek alternatives to mitigate its effects or to prevent its occurrence have been done widely in the last decades. One of the methodologies to assess its occurrence is performed by prediction, which usually focuses on power systems fault simulations. In the Brazilian norm of PQ, there is the general designation short duration voltage variation (VTCD) for these three types of disturbances, which are classified both in terms of magnitude and duration. In this context, this work assess by the prediction the influence of three-phase transformers winding connection and neutral grounding in the quantities of VTCD, especially voltage sags, and in the index value Impact Factor (FI) of the Brazilian regulation standard, which are observed in a node with connection to an industrial consumer. The case studies are performed on a simulated power system in the Alternative Transients Program (ATP), which has two transformers in its network: one substation transformer and another at entrance of the industrial consumer node. Two possible winding connections are considered for the entrance transformer, and a ground resistance is applied to the neutral of both transformers in each case, being changed their value. Voltages in the industrial consumer node are verified by two different ways: phase-to-ground voltages and phase-to-phase voltages. It is observed that there are differences for these quantities and for the value of the FI due to the winding connection of the entrance transformer, the value of the neutral ground resistance of both transformers and the ways of voltage verification.
7

Estimativa de indicadores de afundamentos de tensão em sistemas de distribuição de energia elétrica

Telles, Priscila January 2017 (has links)
Os afundamentos de tensão são distúrbios que afetam grandemente a qualidade da energia fornecida aos consumidores, se mostrando especialmente danosos para os consumidores industriais que dependem de tensões em níveis adequados para a continuidade de seus processos de fabricação. O desempenho das redes elétricas frente aos afundamentos de tensão é usualmente mensurado através de indicadores, que dentre outros propósitos, fornecem as informações necessárias ao planejamento de ações voltadas à mitigação dos efeitos dos afundamentos de tensão causados por faltas. Em geral, as regiões da rede vulneráveis a este tipo de distúrbio são identificadas através de medições em pontos de interesse ao longo da rede. No entanto, esta abordagem se mostra restritiva, pois abrange áreas pontuais e intervalos de tempo pouco representativos. Neste contexto, o presente trabalho propõe uma metodologia para estimar os indicadores de afundamentos de tensão, utilizando medições em um único terminal da rede. A técnica é baseada na determinação da localização das faltas para estimar as magnitudes dos afundamentos em todos os nós da rede. Estas informações são utilizadas para caracterizar o desempenho dos sistemas de distribuição em relação aos afundamentos de tensão que ocorrem em um dado período de estudo. A validação da metodologia foi efetuada a partir de simulações de faltas nos sistemas testes IEEE 13 nós e 34 nós. Os testes incluem a análise da sensibilidade da técnica frente a variações no carregamento da rede, considerando diversos cenários de faltas. / Voltage sags are disturbances that greatly affect the power quality supplied to customers and are especially damaging to industrial customers which rely on adequate voltage levels for the continuity of manufacturing processes. Electrical networks’ performance against voltage sags is usually measured by indices that among other purposes, provide the necessary information for planning actions aiming to mitigate the effects of voltage sags caused by faults. In general, areas vulnerable to this type of disturbance are identified by measurements at points of interest along the network. However, this approach is restrictive, since it covers punctual areas and reduced time intervals. In this context, this work proposes a methodology for estimating voltage sags indices using measurements at a single terminal. The technique is based on the fault location to estimate the magnitudes of voltage sags in all network nodes. This information is used to evaluate the performance of distribution systems in relation to the occurrence of voltage sags in a given period of study. The method’s validation was performed by fault simulations in the IEEE 13 node and 34 node test systems. The tests include a sensitivity analysis considering load variation and several fault scenarios.
8

Estudo da influência da conexão e aterramento de transformadores trifásicos em variações de tensão de curta duração

Costa, Lucas Araujo da January 2018 (has links)
Sendo as interrupções, os afundamentos de tensão e as sobretensões distúrbios de Qualidade de Energia Elétrica (QEE) com potencial de grande impacto econômico, estudos que procuram alternativas de mitigação de seus efeitos ou prevenção de sua ocorrência têm sido amplamente realizados nas últimas décadas. Uma das metodologias de avaliação de sua ocorrência é realizada pela predição, que geralmente se concentra em simulações de faltas em parcelas de sistemas elétricos de potência. Nos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST), encontra-se a denominação geral de Variações de Tensão de Curta Duração (VTCD) para estes três tipos de distúrbios, os quais podem ser classificados tanto por sua magnitude quanto por sua duração. Nesse contexto, este trabalho avalia pela predição a influência exercida pela conexão e o aterramento do neutro de transformadores trifásicos nas quantidades de VTCD, especialmente de afundamentos de tensão, e no valor do índice Fator de Impacto (FI) do PRODIST, que são observados em um nó com conexão a um consumidor industrial Realizam-se estudos de caso sobre um sistema de potência simulado no software Alternative Transients Program (ATP), o qual possui dois transformadores em sua rede: um transformador da subestação e outro na entrada do nó do consumidor industrial. Consideram-se duas conexões possíveis para o transformador de entrada, e aplica-se uma resistência de aterramento para o neutro de ambos os transformadores em cada caso, alteram-se o seu valor. Verificam-se as tensões no nó do consumidor industrial de duas formas diferentes: tensões fase-terra e tensões fase-fase. Observa-se, assim, que há diferenças para estas quantidades e para o valor do FI devidas à forma de conexão do transformador de entrada, valor da resistência de aterramento de neutro de ambos os transformadores e formas de verificação das tensões. / Since interruptions, voltage sags and overvoltages are Power Quality (PQ) disturbances with great economic impact potential, studies that seek alternatives to mitigate its effects or to prevent its occurrence have been done widely in the last decades. One of the methodologies to assess its occurrence is performed by prediction, which usually focuses on power systems fault simulations. In the Brazilian norm of PQ, there is the general designation short duration voltage variation (VTCD) for these three types of disturbances, which are classified both in terms of magnitude and duration. In this context, this work assess by the prediction the influence of three-phase transformers winding connection and neutral grounding in the quantities of VTCD, especially voltage sags, and in the index value Impact Factor (FI) of the Brazilian regulation standard, which are observed in a node with connection to an industrial consumer. The case studies are performed on a simulated power system in the Alternative Transients Program (ATP), which has two transformers in its network: one substation transformer and another at entrance of the industrial consumer node. Two possible winding connections are considered for the entrance transformer, and a ground resistance is applied to the neutral of both transformers in each case, being changed their value. Voltages in the industrial consumer node are verified by two different ways: phase-to-ground voltages and phase-to-phase voltages. It is observed that there are differences for these quantities and for the value of the FI due to the winding connection of the entrance transformer, the value of the neutral ground resistance of both transformers and the ways of voltage verification.
9

Estudo da influência da conexão e aterramento de transformadores trifásicos em variações de tensão de curta duração

Costa, Lucas Araujo da January 2018 (has links)
Sendo as interrupções, os afundamentos de tensão e as sobretensões distúrbios de Qualidade de Energia Elétrica (QEE) com potencial de grande impacto econômico, estudos que procuram alternativas de mitigação de seus efeitos ou prevenção de sua ocorrência têm sido amplamente realizados nas últimas décadas. Uma das metodologias de avaliação de sua ocorrência é realizada pela predição, que geralmente se concentra em simulações de faltas em parcelas de sistemas elétricos de potência. Nos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST), encontra-se a denominação geral de Variações de Tensão de Curta Duração (VTCD) para estes três tipos de distúrbios, os quais podem ser classificados tanto por sua magnitude quanto por sua duração. Nesse contexto, este trabalho avalia pela predição a influência exercida pela conexão e o aterramento do neutro de transformadores trifásicos nas quantidades de VTCD, especialmente de afundamentos de tensão, e no valor do índice Fator de Impacto (FI) do PRODIST, que são observados em um nó com conexão a um consumidor industrial Realizam-se estudos de caso sobre um sistema de potência simulado no software Alternative Transients Program (ATP), o qual possui dois transformadores em sua rede: um transformador da subestação e outro na entrada do nó do consumidor industrial. Consideram-se duas conexões possíveis para o transformador de entrada, e aplica-se uma resistência de aterramento para o neutro de ambos os transformadores em cada caso, alteram-se o seu valor. Verificam-se as tensões no nó do consumidor industrial de duas formas diferentes: tensões fase-terra e tensões fase-fase. Observa-se, assim, que há diferenças para estas quantidades e para o valor do FI devidas à forma de conexão do transformador de entrada, valor da resistência de aterramento de neutro de ambos os transformadores e formas de verificação das tensões. / Since interruptions, voltage sags and overvoltages are Power Quality (PQ) disturbances with great economic impact potential, studies that seek alternatives to mitigate its effects or to prevent its occurrence have been done widely in the last decades. One of the methodologies to assess its occurrence is performed by prediction, which usually focuses on power systems fault simulations. In the Brazilian norm of PQ, there is the general designation short duration voltage variation (VTCD) for these three types of disturbances, which are classified both in terms of magnitude and duration. In this context, this work assess by the prediction the influence of three-phase transformers winding connection and neutral grounding in the quantities of VTCD, especially voltage sags, and in the index value Impact Factor (FI) of the Brazilian regulation standard, which are observed in a node with connection to an industrial consumer. The case studies are performed on a simulated power system in the Alternative Transients Program (ATP), which has two transformers in its network: one substation transformer and another at entrance of the industrial consumer node. Two possible winding connections are considered for the entrance transformer, and a ground resistance is applied to the neutral of both transformers in each case, being changed their value. Voltages in the industrial consumer node are verified by two different ways: phase-to-ground voltages and phase-to-phase voltages. It is observed that there are differences for these quantities and for the value of the FI due to the winding connection of the entrance transformer, the value of the neutral ground resistance of both transformers and the ways of voltage verification.
10

Análise do impacto da inserção de novas fontes de energia no nível de afundamentos de tensão utilizando a matriz impedância de barras

Bortolosso, Cassio January 2016 (has links)
Nesta dissertação, é apresentada uma metodologia para cálculo de afundamentos de tensão na presença de fontes alternativas de energia. Um método para determinar o grau de influência da reatância de outras unidades geradoras conectadas ao sistema elétrico no que se refere a afundamentos de tensão é desenvolvido. É utilizada a matriz impedância de barras – Zbus para a obtenção de expressões analíticas para a magnitude de afundamentos de tensão causados por faltas na rede. Uma análise matemática das expressões obtidas e uma análise de sensibilidade são feitas com observações acerca das características propiciadas pela inserção de novas fontes de geração. As expressões analíticas são utilizadas para classificar as barras quanto ao número de afundamentos causados por faltas trifásicas e fase-terra em todas as barras do sistema. De maneira similar, a alocação de uma unidade de geração específica é feita com o objetivo de reduzir o número de afundamentos de tensão observados na rede. As expressões em termos da reatância do gerador são usadas na solução de um conjunto de inequações observando a necessidade da manutenção de níveis mínimos aceitáveis de tensão requisitados por cargas sensíveis, a relação entre a reatância do novo gerador e sua capacidade de mitigação de afundamentos fica evidenciada. / This work presents a methodology for voltage sags analysis in the presence of alternative energy sources. The method determines the degree of influence of the reactance from the new generating units connected to the electrical system with regard to voltage sags magnitudes. The impedance matrix – Zbus is used to obtain analytical expressions voltage sags magnitude caused by faults in the grid. A mathematical analysis of the obtained expressions and a sensitivity analysis are made with observations about the characteristics afforded by the inclusion of new generation sources. The analytical expressions are used to rank the bars as the number of sags caused by three-phase and phase to ground faults on all system buses. Similarly, the allocation of a specific generation unit is done in order to reduce the number of voltage sags over the grid. The expressions in terms of the generator reactance are used on solving a set of inequalities, observing the need to maintain minimum acceptable voltage levels required by sensitive loads, the relationship between the reactance of the new generator and its sag mitigation capability is evidenced.