• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do comportamento de agressividade em ratos expostos ao cádmio e submetidos ao estresse por imobilização /

Terçariol, Simone Galbiati. January 2008 (has links)
Resumo: O objetivo do presente trabalho foi avaliar a agressividade de ratos expostos concomitantemente ao cádmio (Cd) e ao estresse por imobilização (EI). Ratos Wistar, machos, provenientes do Biotério Central da Unesp, foram divididos em 2 grupos experimentais: A- animais intrusos (sem tratamento) e B- animais residentes, os quais receberam um dos seguintes tratamentos: acetato de sódio (controle); acetato de cádmio (solução a 50 ppm de Cd na água de beber); submetidos ao estresse por imobilização (30 minutos, 3 vezes ao dia, 5 dias por semana, durante 4 semanas); expostos ao Cd e concomitantemente submetidos ao estresse por imobilização. O comportamento de agressividade dos animais residentes foi avaliado ao final da última semana do experimento, baseando-se no paradigma do animal intruso/residente, segundo os seguintes parâmetros: número total de ataques (NTA), tempo de latência para a 1º mordida (TLM), tempo total de manifestações de ataques (TTMA) e escore de agressão composta (EAC). Após a avaliação do comportamento de agressividade, o sangue e o cérebro dos animais foram coletados para dosagem de Cd por espectrometria de absorção atômica. O nível de cádmio no sangue não se alterou, mas no cérebro foi aumentado. Observou-se que exposição ao Cd ou estresse por imobilização sozinhos, não modificaram o NTA, TLM, TTMA ou EAC, porém, exposição ao Cd e EI concomitantemente aumentou significantemente o NTA, TTMA e o EAC. Esses resultados sugerem que exposição dos ratos à baixa dose de Cd associado ao estresse por imobilização pode causar interação e provocar aumento da agressividade dos animais. Um possível papel da serotonina (5-HT) e nível aumentado de cádmio no cérebro, como mecanismos responsáveis pela agressividade anormal observada, é discutido. / Abstract: The aim of this study was to assess the aggressiveness in rats concomitantly exposed to cadmium (Cd) and stress by immobilization (EI). Male Wistar rats, 70 days old, from the Biotério Central - UNESP, Botucatu - SP, were allocated into 2 experimental groups: A-intruder animals (without treatment) and B-resident animals, which received one of the following treatments: sodium acetate (control); Cadmium acetate (50 ppm Cd in drinking water); stress by immobilization (30 min, three times per day, five days per week, during four weeks); Cd exposure and concomitant stress by immobilization. The aggressive behavior of resident rats was evaluated at the end of the last experimental week based on the intruder/resident animal paradigm, according to the following parameters: total number of attacks (TNA), latent time for the first bite (LTB), total time of attack manifestations (TTAM), and composed aggression score (CAS). After aggressive behavior assessement, blood and brains were collected to determine Cd through atomic absorption spectrometry. Cd level was not altered in the blood but increased in the brain. Cd exposure or EI, alone, did not modify TNA, LTB, TTAM or CAS but Cd exposure and EI, concomitantly, increased significantly TNA, TTAM and CAS. These results suggest that rat exposure to low Cd level associated with stress by immobilization may lead to interaction with consequent increased animal aggressiveness. A possible paper of serotonin (5-HT) and increased brain Cd levels as responsible mechanisms by the observed abnormal aggressiveness is discussed. / Orientador: José Ricardo de Arruda Miranda / Coorientador: Antonio Francisco Godinho / Banca: Ethel Lourenzi Novelli / Banca: João Lauro Viana de Camargo / Mestre
2

Desgaste abrasivo e dureza de seis resinas compostas expostas a diferentes tempos de fotopolimerização com aparelhos de LED e lâmpada incandescente /

Ulhôa, Michele Paoline de Marins. January 2006 (has links)
Orientador: Eduardo Carlos Bianchi / Banca: Cesar Antunes de Freitas / Banca: Paulo Noronha Lisboa Filho / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: A Humanidade, ao buscar as melhoras nas suas condições de vida, vem desenvolvendo materiais capazes de reparar e melhorar imperfeições naturais e acidentais. Encontra nas resinas compostas, constantemente utilizadas por dentistas, uma maneira de reparar imperfeições e perdas de materiais dentários no ser humano. A escolha de resinas compostas em substituição aos antigos materiais de restauração, como o amálgama, se dá pelo fato de serem fáceis de preparar, apresentarem menor desgaste, serem praticamente imperceptíveis após sua aplicação devido à grande quantidade de cores fornecidas pelos fabricantes. Porém não apresentam desgaste semelhante ao do esmalte dentário, sendo necessária substituição com o passar do tempo, devido ao desgaste abrasivo. Dentre os vários fatores determinantes do processo de desgaste abrasivo, encontram-se, genericamente, as características da própria resina e do preparo cavitário, assim como da restauração confeccionada e das condições das agressões a que ela for submetida. Para fazer a medição da resistência ao desgaste abrasivo, utilizou-se o método do disco retificado aperfeiçoado para Odontologia (COELHO, 1991; BIANCHI et al., 2002). É utilizado um banco de ensaios onde um disco dinâmico revestido com porcelana desgasta um disco estático revetido com a resina polimerizada em um tempo pré-estabelecido... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Humanity, when searching for a better life conditions, is developing materials capable to repair and to improve natural and accidental imperfections. It finds in composite resins, constantly used for dentists, a way to repair imperfections and losses of human dental material. The composed resin choice in substituion to the old restoration materials, as the amalgamates, it is for the fact of being easy to prepare, to present less wear, to be practically invisible after its application due to great amount of colors supplied for the manufacturers. However they do not show similar wear as the dental enamel, being necessary the substitution after a while, due to the abrasive wear. Among some determinative factors of the process of abrasive wear, there are, generically, the characteristics of the resin and the cavitary preparation, as well as the confectioned restoration and the conditions of the aggressions that it is submitted. To make the measurement of the resistance to the abrasive wear, the method of the rectified circular surface improved for odontology was used (COELHO, 1991; BIANCHI et al., 2002). A Test bench is used where a dynamic circular surface covered with porcelain consumes a static circular surface covered with the polymerized resin in a pre-established time... (Complete abstract, click electronic address below) / Mestre
3

Monitoramento da dressagem na retificação através do sinal puro de emissão acústica /

Hellmeister, Carmen Francisca Lourenço Pinto. January 2004 (has links)
Orientador: Paulo Roberto de Aguiar / Banca: Wisley Falco Sales / Banca: Eduardo Carlos Bianchi / Resumo: No processo de retificação com rebolo convencional, a operação de dressagem é preocupante, pois é geradora de tempo improdutivo, consumindo capacidade de máquinas e mão-de-obra normalmente especializada, além de consumo de energia elétrica, de rebolo e do próprio dressador. As indústrias brasileiras que trabalham com retificação, não controlam de maneira criteriosa os parâmetros de dressagem dos rebolos, uma vez que seriam necessários projetor de perfis, controle de rotação do rebolo e do passo de dressagem. Assim, este trabalho teve como objetivo monitorar a dressagem na retificação, propondo um conceito alternativo para esta operação, onde técnicas de monitoramento e processamento de sinais foram utilizadas sobre o sinal puro de emissão acústica captado durante a dressagem. Para isso, foi... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In grinding process with aluminum oxide grindign wheel the dressing operation brings preocupation since it is a time-unproductive source, consuming machining capability and usually specialized operator work as well as electrical energy consumption and the wear of the grinding wheel and dresser itself. The Brazilian industries that employ grinding processes do not control the dressing parameters efficiently due to the need of profile measurement equipament, control of grinding wheel speed and dressing passes control. Thus, this work aims to monitor the dressing operation and present and alternative concept for such operation, where digital signal processing and signal monitoring techniques were employed in the raw acoustic emission signal collected during the dressing operation. Dedicated software... (Complete abstract click electronic access below) / Mestre
4

Efeito da privação de ninho sobre a agressividade e o sucesso de acasalamento em machos de tilápia do Nilo /

Mendonça, Francine Zocoler de. January 2006 (has links)
Orientador: Eliane Gonçalves de Freitas / Banca: Rosana Mattioli / Banca: Mateus José Rodrigues Paranhos da Costa / Resumo: Machos dominantes de Oreochromis niloticus defendem território no substrato, onde escavam ninhos para a reprodução. Alguns sistemas de criação de tilápia do Nilo utilizam tanques sem substrato, assim, testamos se a privação da construção de ninho aumenta a agressividade e interfere no sucesso de acasalamento dos machos dominantes. Foram utilizados dois grupos formados por 2 machos e 3 fêmeas: um com substrato (COM: n = 9), onde o aquário (~140L) continha uma camada de 3 cm de substrato de pedrisco, e um grupo sem substrato (SEM: n = 11) onde os animais foram privados da construção de ninho. Os animais permaneceram agrupados por 10 dias e o comportamento agonístico do macho dominante foi registrado através de quatro sessões de filmagens (20 min cada), sendo a primeira, 24 horas após o agrupamento e as outras três, a cada 72 horas. A agressividade foi inferida pela freqüência total de unidades de alta intensidade (frontal, lateral, paralelo e ondulação) emitidas pelo macho dominante para o submisso e para as fêmeas. A agressividade foi maior no grupo SEM (97.73 l 31.77. 80 min-1) do que no COM (61.75 l 13.24. 80 min-1; Mann-Withney, p = 0.008). Foram analisados a Taxa de Crescimento Específico (TCE) e o Índice Hepatossomático (IHS) dos dominantes como indicador de gasto energético. A TCE e o IHS foram menores para os dominantes que construíram ninhos (TCE: COM 0.86 l 0.44%.10 dia-1; SEM 1.48 l 0.52% .10 dia-1; teste t, p = 0.10; IHS: COM 1.39 l 0.42% .10 dia-1; SEM 2.16 l 0.82% .10 dia-1; teste t, p = 0.10), o que é indicativo de que os machos dominantes gastam energia escavando ninho, diminuindo a energia disponível para os ataques de alta intensidade. Além disso, foram registrados a latência e a porcentagem de desova, sendo esses similares nos grupos COM e SEM. O índice gonadossomático foi também analisado e maior nos dominantes... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Dominant males of Nile tilapia, Oreochromis niloticus, defend territory on substrates where they dig mating nests. Because some kinds of rearing systems of Nile tilapia use tanks with no substrate inside, our aim was to test whether nest digging privation increases aggressiveness in that species. As we have observed spawning in such conditions, we also tested the effect of nesting privation on dominant’s mating success. Two groups formed by 2 males and 3 females each were used: a substrate inside-group (INS; n = 9), whose glass aquaria (~140L) had a 3 cm-layer of gravel, and a non substrate-group (NOS; n = 11) where animals were unable to dig nests. Groups were kept by 10 days and the agonistic behavior of dominant male was video-recorded in 4 sessions (20 min each), the first after 24 hours from grouping and the other 3, every 72 hours. Aggressiveness was inferred by the total frequency of high aggression intensity units (nip, mouthfight, lateral fight and undulation) given by the dominant male in contests with females and subordinate males. The aggressiveness was higher in the NOS (97.73 l 31.77. 80 min-1) than in the INS group (61.75 l 13.24. 80 min-1; Mann-Withney, p = 0.008). We analyzed the Specific Growth Rate and Hepatosomatic Index of dominants as indicators of energy expenditure, whose were higher for dominants that dig nests (SGR: INS 0.86 l 0.44% .10 day-1; NOS 1.48 l 0.52% .10 day- 1; t test, p = 0.10; HIS: INS 1.39 l 0.42% .10 day-1; NOS 2.16 l 0.82% .10 day-1; t test, p = 0.10). Dominant males seem to spend much energy digging nests and deviate energy from high aggressive contests. Moreover, we registered the latency to spawn and the percentage of spawning, whose was similar among INS and NOS groups. Gonadosomatic Index was also analyzed and it was higher in dominant... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0814 seconds