Spelling suggestions: "subject:"águas residual - eliminação"" "subject:"águas residual - deliminação""
1 |
Tratamento de águas residuárias de indústria de fécula de mandioca através de biodigestor anaeróbio com separação de fases em escala pilotoFeiden, Armin [UNESP] 10 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:37Z (GMT). No. of bitstreams: 0
Previous issue date: 2001-10Bitstream added on 2014-06-13T20:42:04Z : No. of bitstreams: 1
feiden_a_dr_botfca.pdf: 724227 bytes, checksum: f44b6abe5350bcc2ba61563cb10eb26b (MD5) / As fecularias são indústrias que processam mandioca para obtenção de amido. São inúmeras as unidades reunidas, principalmente, na região oeste do Estado do Paraná, gerando uma grande quantidade de águas residuárias poluentes. A solução usual é o tratamento em lagoas de estabilização o que, porém, apresenta problemas como emissão de gases poluentes e ocupação de grandes áreas. Os resultados obtidos neste trabalho referem-se ao tratamento de águas residuárias do processamento de uma indústria de fécula de mandioca, através de um sistema contínuo de biodigestão anaeróbia, com separação de fases, em escala piloto. Os biodigestores com separação de fases comprendem um reator acidogênico, cuja função é transformar o substrato bruto em ácidos orgânicos e um reator metanogênico que transforma estes ácidos em biogás e materiais orgânicos estabilizados. A separação de fases aumenta a estabilidade e a capacidade de trabalhar com materiais altamente solúveis, como os resíduos das indústrias de amido. A pesquisa foi conduzida junto a empresa M.C.R. Alimentos Ltda, uma fecularia com capacidade de processar 250 toneladas de mandioca por dia, localizada no município de Mercedes, região Oeste do Estado do Paraná. Está situada no paralelo 24°09'18'' de Latitude Sul e meridiano 54°09'26'' de Longitude... / It was used a pilot scale two-stage anaerobic reactor to study the biological treatment of cassava wastewater. The research was carried at a Cassava processing factory, with a capacity of 250 metric tons day-1. It is located in West Paraná, South of Brazil, near the border of the Paraná River, at the parallel 24°09'18'' South latitude and meridian 54°09'26'' West longitude of Grw. The system consisted of two settling tanks with 500 L each, connected in series, followed by a two-stage anaerobic biodigester. The acidogenic reactor had a capacity of 1,000 L and the metanogenic had a capacity of 3,000 L. The experiment was conducted at ambient temperature, without nutrients and pH correction. The best result were obtained at a flow rate of 901 L d-1, with a TOC (total organic carbon) loading rate of 0.565 g L-1 d-1 (around a COD (chemical oxigen demand) of 2.49 g L-1 d-1) and a hidraulic residence time of 4.4 days. At this loading rate, the system achieved the following removal efficiencies: 77% of TOC and COD removal; 66% of Total Solids removal; 78% of Volatile Solids removal; 98% of Total Cyanide...(Complete abstract, click electronic access below)
|
2 |
Estudo da eficiência da desinfecção solar de águas residuárias domésticas em reatores de diferentes colorações /Queluz, João Gabriel Thomaz, 1985- January 2013 (has links)
Orientador: Rodrigo Máximo Sánchez Román / Banca: Raimundo Leite Cruz / Banca: Marcos Vinicius Folegatti / Resumo: A utilização de água residuária doméstica (ARD) na agricultura irrigada exige medidas de desinfecção para garantir padrões de qualidade e proteger a saúde humana dos patógenos presentes. Raios UV são eficientes para esta finalidade e há diversos relatos de sistemas de desinfecção solar (SODIS - solar disinfection), tanto para a desinfecção de água para consumo humano quanto para a desinfecção de ARD. Não há estudos sobre a eficiência da desinfecção de ARDs utilizando-se diferentes revestimentos nos reatores solares de concreto. O objetivo do presente trabalho foi avaliar a eficiência da desinfecção solar de ARD para reúso na agricultura em reatores solares com diferentes colorações: preta, branca e concreto. A ARD, após passar pelo tanque séptico, era conduzida aos reatores, formando lâminas de água residuária com 10 cm de profundidade, que ficavam expostas à radiação solar durante três dias consecutivos. A eficiência da desinfecção foi avaliada pela concentração de coliformes fecais (CF), demanda química de oxigênio (DQO), temperatura do efluente, radiação global, radiação UV, pH e sólidos suspensos totais (SST). Os dados foram analisados utilizando-se análise de regressão propondo-se um modelo matemático que representa a inativação de patógenos. O efluente do tanque séptico utilizado na desinfecção solar apresentou em média os seguintes padrões de qualidade: 1,29 x 106 NMP 100mL-1 (Número mais provável a cada 100ml), 654,96 mgDQO L-1, 180,33 mgSST L-1 e 6,17 de pH. Durante o processo constataram-se melhorias nos padrões DQO e SST nos reatores. / Abstract: The use of domestic wastewater (DWW) in irrigated agriculture requires disinfection measures to protect human health from pathogens. UV rays are effective for this purpose and there are many reports of solar disinfection (SODIS) systems, for both disinfection of drinking water and disinfection of DWW. The literature does not present any studies on the disinfection efficiency of DWW using different colors in concrete solar reactors. The aim of this study was to evaluate the efficiency of DWW solar disinfection for agriculture reuse in solar reactors with different colors: black, white and concrete. DWW, after passing through the septic tank was conducted to the reactors until the water depth reach 10 cm that was exposed to sunlight for three consecutive days. The disinfection efficiency was evaluated by the concentration of fecal coliforms (FC), chemical oxygen demand (COD), effluent temperature, global radiation, UV radiation, pH and total suspended solids (TSS). The data were analyzed using regression analysis and a mathematical model that represents the inactivation of pathogens was proposed. The effluent from the septic tank used for solar disinfection had the following mean quality standards: 1.29 x 106 MPN 100mL-1 654.96 mgCOD L-1, 180.33 mgSST L-1 and pH 6.17. During the process it was noticed improvement in COD as well as TSS concentration in the reactors. Furthermore, the results show that the effluent in different reactors had distinct temperatures: the highest rates were observed in the black reactor ... / Mestre
|
3 |
Estudo da eficiência da desinfecção solar de águas residuárias domésticas em reatores de diferentes coloraçõesQueluz, João Gabriel Thomaz [UNESP] 19 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-07-19Bitstream added on 2014-06-13T20:55:19Z : No. of bitstreams: 1
queluz_jgt_me_botfca.pdf: 1104809 bytes, checksum: 3566202d2ec1ce904f94f9952a25c713 (MD5) / A utilização de água residuária doméstica (ARD) na agricultura irrigada exige medidas de desinfecção para garantir padrões de qualidade e proteger a saúde humana dos patógenos presentes. Raios UV são eficientes para esta finalidade e há diversos relatos de sistemas de desinfecção solar (SODIS – solar disinfection), tanto para a desinfecção de água para consumo humano quanto para a desinfecção de ARD. Não há estudos sobre a eficiência da desinfecção de ARDs utilizando-se diferentes revestimentos nos reatores solares de concreto. O objetivo do presente trabalho foi avaliar a eficiência da desinfecção solar de ARD para reúso na agricultura em reatores solares com diferentes colorações: preta, branca e concreto. A ARD, após passar pelo tanque séptico, era conduzida aos reatores, formando lâminas de água residuária com 10 cm de profundidade, que ficavam expostas à radiação solar durante três dias consecutivos. A eficiência da desinfecção foi avaliada pela concentração de coliformes fecais (CF), demanda química de oxigênio (DQO), temperatura do efluente, radiação global, radiação UV, pH e sólidos suspensos totais (SST). Os dados foram analisados utilizando-se análise de regressão propondo-se um modelo matemático que representa a inativação de patógenos. O efluente do tanque séptico utilizado na desinfecção solar apresentou em média os seguintes padrões de qualidade: 1,29 x 106 NMP 100mL-1 (Número mais provável a cada 100ml), 654,96 mgDQO L-1, 180,33 mgSST L-1 e 6,17 de pH. Durante o processo constataram-se melhorias nos padrões DQO e SST nos reatores. / The use of domestic wastewater (DWW) in irrigated agriculture requires disinfection measures to protect human health from pathogens. UV rays are effective for this purpose and there are many reports of solar disinfection (SODIS) systems, for both disinfection of drinking water and disinfection of DWW. The literature does not present any studies on the disinfection efficiency of DWW using different colors in concrete solar reactors. The aim of this study was to evaluate the efficiency of DWW solar disinfection for agriculture reuse in solar reactors with different colors: black, white and concrete. DWW, after passing through the septic tank was conducted to the reactors until the water depth reach 10 cm that was exposed to sunlight for three consecutive days. The disinfection efficiency was evaluated by the concentration of fecal coliforms (FC), chemical oxygen demand (COD), effluent temperature, global radiation, UV radiation, pH and total suspended solids (TSS). The data were analyzed using regression analysis and a mathematical model that represents the inactivation of pathogens was proposed. The effluent from the septic tank used for solar disinfection had the following mean quality standards: 1.29 x 106 MPN 100mL-1 654.96 mgCOD L-1, 180.33 mgSST L-1 and pH 6.17. During the process it was noticed improvement in COD as well as TSS concentration in the reactors. Furthermore, the results show that the effluent in different reactors had distinct temperatures: the highest rates were observed in the black reactor ...
|
Page generated in 0.0641 seconds