• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Évolution de la qualité microbienne de l'air circulant dans les centrales de traitement de l'air (CTA) d'un centre hospitalier

Morissette, Pamela 28 January 2021 (has links)
Dans les hôpitaux, les bioaérosols en suspension dans l’air peuvent contenir des cellules bactériennes ou fongiques provenant des patients, des visiteurs, du personnel et de l’environnement extérieur. Les centrales de traitement de l’air (CTA) sont des unités permettant de filtrer, de conditionner et d’assurer une bonne qualité de l’air aux occupants et sont présentes dans certains hôpitaux. Dans la littérature, il n’y a pas de consensus sur le choix des échantillonneurs d’air et les méthodes d’analyse lorsqu’on désire évaluer la qualité de l’air qui est traité dans ces centrales. Le principal défi consiste à éviter la perturbation des soins aux patients lors de l’échantillonnage de l’air dans les CTA. Le présent projet a permis de développer un protocole permettant l’échantillonnage des bioaérosols dans les CTA en utilisant des cannes d’échantillonnage sans perturber les activités qui se déroulent dans l’hôpital. L’objectif de cette étude longitudinale était d’analyser la qualité microbiologique de l’air lors de dix campagnes s’échelonnant sur une période d’un an. Les résultats de cette étude ont démontré que les saisons affectaient significativement les concentrations de microorganismes cultivables et totaux dans l’air intérieur et extérieur d’un hôpital, mais l’effet saisonnier n’influençait pas les concentrations de particules. Le traitement de l’air réalisé avec plusieurs filtres s’est avéré efficace afin de réduire les charges microbiennes et les particules. L'utilisation des méthodes de séquençage Sanger pour l’identification des colonies isolées et de séquençage à haut débit de gènes universels a permis d'obtenir un aperçu de la diversité des espèces bactériennes et fongiques et de valider l’utilisation de marqueurs d’air biologiques. Ce projet a permis d’élaborer des méthodes d’échantillonnage en air dynamique et à haut débit. Il permettra de proposer une stratégie assurant le suivi à long terme de la qualité de l’air à l'intérieur d’un hôpital sans perturber les activités qui s’y déroulent. / Air contains bioaerosols, which are airborne particles of biological origin, including bacterial or fungal cells. Bioaerosols in hospitals may contain microorganisms from patients, visitors, staff, and the outdoor environment. Air treatment units (ATU) are present in certain hospitals and aim to ensure the best air quality for occupants. The literature is scarce when it comes to the choice of air samplers and the method of analyses to assess the air quality in these ATUs. The main challenge is to avoid disruption of patient care during air sampling. The present project developed a protocol allowing the sampling of bioaerosols in ATU using sampling rods and, therefore, without disturbing the activities taking place in the hospital. The objective of this longitudinal study was to analyze the microbiological quality of the air during ten campaigns over one year. The results of this study demonstrated that the seasons significantly affect the concentrations of culturable and total microorganisms in the indoor and outdoor air of a hospital. Airborne particle concentrations were not affected by these seasonal changes. Air treatment with several filters was proven to be effective in reducing microbial loads and particles. The use of Sanger sequencing to identify isolated colonies and next-generation sequencing methods provided insight into the diversity of bacterial and fungal species. This project developed high-velocity dynamic air sampling methods. The study proposes a strategy ensuring long-term monitoring of air quality inside a hospital without disturbing the activities that are taking place inside and to validate the use of biological markers for contaminants in the air in a normal situation.
2

Quantification et visualisation des conditions ambiantes intérieures par thermographie infrarouge

Djupkep Dizeu, Frank Billy 23 April 2018 (has links)
Le niveau de confort thermique est devenu un important critère à considérer durant la conception des habitations contemporaines. Dans certaines régions du monde, la ventilation naturelle ne permet pas de maintenir un environnement confortable à l'intérieur des habitations. On a recours aux systèmes de climatisation pour créer un microclimat intérieur artificiel confortable. Le microclimat intérieur est une combinaison de la température de l'air, de la vitesse de l'air, de l'humidité de l'air et de la température moyenne de rayonnement. Dans cette thèse, nous développons une instrumentation qui utilise la thermographie infrarouge pour mesurer et visualiser les paramètres du microclimat intérieur. Nous entamons nos investigations par la conception d'un capteur et procédons à la validation théorique de son modèle thermique. Ce capteur est l'élément intermédiaire qui permet de quantifier et de visualiser les paramètres du microclimat intérieur à l'aide d'une caméra infrarouge. La quantification de ces paramètres est possible après qu'un problème de transfert thermique inverse ait été résolu. La visualisation de ces paramètres est possible après que les coordonnées 3D d'un ensemble de capteurs disposés dans le champ de vision de la caméra aient été déterminées. Des outils de traitement d'images sont présentés et permettent la mesure précise de la température des capteurs et la localisation 3D de ces capteurs dans l'espace réel. Une validation expérimentale est finalement effectuée. Il en ressort que le système de mesure développé est précis, fiable, et robuste. Une caméra infrarouge et un ensemble de capteurs judicieusement disposés dans l'espace peuvent permettre de quantifier et de cartographier le microclimat intérieur. / The level of thermal comfort has become an important criterion to consider during the design of contemporary buildings. In some parts of the world, natural ventilation is not adequate to maintain a comfortable indoor environment. Air conditioning systems are used in order to create a comfortable artificial indoor microclimate. The indoor microclimate is a combination of air temperature, air speed, humidity and mean radiant temperature. In this thesis, we develop a measuring system that uses infrared thermography to measure and visualize the parameters of the indoor microclimate. We begin our investigations by designing a sensor and we proceed to the theoretical validation of its thermal model. This sensor is the auxiliary element which allows the quantification and the visualization of the parameters of the indoor microclimate with an infrared camera. The quantification of these parameters is possible after that an inverse heat transfer problem has been solved. The visualization of these parameters is possible after that the 3D coordinates of a set of sensors placed in the field of view of the camera have been determined. Image processing tools are presented and allow the accurate measurement of sensors temperature and the 3D location of the sensors in real space. Finally, an experimental validation is realized. The results show that the system developed is accurate, reliable, and robust. An infrared camera and a set of sensors wisely arranged in space can be used to quantify and map the indoor microclimate.
3

Primary school buildings renovation in cold climates : optimizing window size and opening for thermal comfort, indoor air quality and energy performance

Darvishi Alamdari, Pourya 30 November 2022 (has links)
Dans les bâtiments scolaires existants, la ventilation naturelle constitue souvent l'unique solution pour le contrôle de la qualité de l'air intérieur et le confort thermique. Cependant, de nombreuses études montrent que les salles de classe sont insuffisamment ventilées et entrainent des problèmes de qualité de l'environnement intérieur. Plusieurs études ont été menées sous différents climats, mais peu dans des climats très froids où l'usage de la ventilation naturelle peut entraîner une surconsommation énergétique. Cette recherche vise à étudier l'impact de la ventilation naturelle sur le confort thermique, la qualité de l'air intérieur et l'efficacité énergétique des bâtiments scolaires dans les climats froids. Divers paramètres architecturaux associés aux fenêtres ont été analysés pour une classe type du corpus Schola. Dans cette recherche, l'orientation des fenêtres, leur taille, leur position, la taille et la position de l'ouverture des fenêtres, le programme de ventilation naturelle et les méthodes de ventilation naturelle (unilatérale et transversale) ont été simulés numériquement avec le logiciel Ladybug Tools. Les résultats des simulations produisent données numériques annuelles de température, humidité, température radiante moyenne, concentration de CO₂, pour traiter les conditions thermiques et de Qualité de l'Air Intérieur QAI dans les bâtiments scolaires et de leur impact sur la performance énergétique. L'analyse des résultats utilise les modèles standards 55 ASHRAE, Predicted Mean Vote PMV et extended Adaptive Thermal Comfort ATC pour l'analyse du confort thermique, la Santé Canada et le Centre de collaboration nationale en santé environnementale, la Federation of European Heating, Ventilation and Air Conditioning Associations REHVA pour le contrôle de la COVID-19. Les résultats montrent que l'ouverture répétitive des fenêtres de courte durée pourrait être une solution optimale en termes de confort thermique, de qualité de l'air intérieur et d'efficacité énergétique. Étant donné que la plupart de ces bâtiments scolaires ne sont pas équipés de systèmes CVC et qu'ils ne disposent que de systèmes de chauffage classiques, le manque de qualité de l'air intérieur est un problème inévitable. La solution de la ventilation naturelle pourrait compenser le manque de qualité de l'air intérieur et le coût de la rénovation du système CVC ; cependant, elle devrait être appliquée avec précision pendant les périodes hivernales pour éviter un inconfort thermique et une surconsommation énergétique. / In existing school buildings in Quebec, natural ventilation is often the only solution for thermal comfort and indoor air quality control. However, many studies show insufficiently ventilated classrooms, leading to indoor environment quality problems. Where the arbitrary use of natural ventilation can lead to energy over consumption, several studies have been conducted on the role of natural ventilation on this issue, but few of them are addressed in very cold climates. This research investigates the impact of natural ventilation on thermal comfort, indoor air quality, and energy efficiency of school buildings in cold climates. Various architectural parameters associated with windows were analyzed for a typical classroom in the Schola.ca corpus. Since most of these school buildings are not equipped with HVAC systems and have only infrastructures for conventional heating systems, the lack of indoor air quality is an inevitable problem. In this research, the windows' orientation, position, opening size, and opening position, natural ventilation program, and window-opening modes (single-sided and cross-window openings) were numerically simulated with the Ladybug Tools software. The software outputs consist of annual numerical data (temperature, humidity, mean radiant temperature, CO₂ concentration, energy, and thermal) representing thermal comfort and IAQ performances in school buildings and their impacts on energy consumption efficiency. In analyzing the result, several standards and guidelines were used, including ASHRAE 55 standard models (Predicted Mean Vote PMV and Adaptive Thermal Comfort models ATC for thermal performance), the Health Canada and National Collaboration Centre for Environmental Health guideline, and the Federation of European Heating, Ventilation and Air Conditioning Associations REHVA to evaluate the building thermal and IAQ performances compared to there commended benchmark models. The results show that repetitive short-term opening of the windows could be an optimal solution in terms of thermal comfort, indoor air quality, and heating energy consumption efficiency. Natural ventilation solutions could retrieve the lack of indoor air quality and the cost of HVAC system renovation; however, they should be only applied during cold seasons to avoid thermal discomfort and energy over consumption.

Page generated in 0.0866 seconds