• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise de sensibilidade através de um modelo implicitamente acoplado para alívio de sobrecargas em redes de transmissão

Hoji, Eduardo Shigueo [UNESP] 23 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:36Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-23Bitstream added on 2014-06-13T20:09:52Z : No. of bitstreams: 1 hoji_es_me_ilha.pdf: 1044314 bytes, checksum: 689b008e9a9531695ae561b63e953e91 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / A reestruturação dos mercados de energia para fornecer livre acesso ao sistema de transmissão e o conseqüente aumento no número de transações de compra e venda de energia tem causado congestionamento nos sistemas de transmissão. Como conseqüência, as redes têm sofrido sobrecargas nas linhas de maneira mais freqüente. Uma maneira prática de se melhorar a capacidade de transferência de potência ativa em uma linha de transmissão é a redução de seu fluxo reativo. Esse controle pode ser feito através de alterações nos controles das fontes de potência reativa e nos taps de transformadores. A definição de quais ações serão tomadas de modo a minimizar o fluxo reativo e aliviar, ou mesmo eliminar, a sobrecarga em uma determinada linha, pode ser realizada através da análise de sensibilidade. Uma vez que se está interessado na resposta do sistema às variações de injeções de reativos, utilizamos a matriz Lc do método CRIC (Calcul de Reseaux Implicitement Couples) de fluxo de potência. Também foi utilizado o modelo constante do método CRIC. A metodologia desenvolvida consiste da manipulação da matriz Lc com outras sensibilidades de primeira ordem, de modo a se obter as sensibilidades entre fluxo reativo nas linhas e injeção de reativos nas barras e fluxo reativo nas linhas e taps dos transformadores. As sensibilidades obtidas fornecem as barras e transformadores mais indicados para alívio de uma determinada sobrecarga e são úteis principalmente em casos emergenciais, nos quais não seja necessária a instalação de novas fontes de reativos. Os resultados obtidos são comparados com os obtidos através de uma metodologia semelhante, que utiliza a matriz jacobiana do método de Newton. Foram utilizados para os testes o sistema Cigré de 32 barras, e o sistema Sul-Sudeste brasileiro em duas configurações de carga diferentes. / The restructuring of energy markets to supply free access to the transmission system and the consequent increase of the number of power transactions has been causing congestions in the transmission systems. As consequence, the networks have been suffering overloads in the lines in a more frequent way. A practice way of improving the transfer capability of active power in a transmission line is to decrease its reactive power flow. That control can be made through changes in the reactive power sources injections and in the transformer ratios of transformers. The definition of which actions will be taken to minimize the reactive flow and to alleviate, or even to eliminate, the overload in a determined line can be accomplished through the sensibility analysis. Once it is interested in the answer of the system to the variations of reactive power injections, we used the matrix Lc from the CRIC (Calcul of Reseaux Implicitement Couples) power flow method. The constant model of CRIC is also used. The developed methodology consists of the manipulation of the matrix Lc with other first order sensibilities, in order to obtain the sensibilities among reactive flow in the lines and reactive power injections in the buses and reactive flow in the lines and transformer ratios of the transformers. The obtained sensibilities indicate the buses and transformers for relieving a certain overload and they are mainly useful in emergency cases, which it is not necessary the installation of new sources of reagents. The obtained results are compared with the obtained through a similar methodology, that uses the of Newton's method jacobian matrix. The methodologies were tested using the 32-bus Cigré network and the South-southeast Brazilian system in two different load configurations.
2

Redespacho de reativos como ação corretiva para alívio de sobrecargas em Redes de transmissão

Hoji, Eduardo Shigueo [UNESP] 25 February 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-02-25Bitstream added on 2014-06-13T19:19:30Z : No. of bitstreams: 1 hoji_es_dr_ilha.pdf: 852924 bytes, checksum: 9b1bcf1d76e563dd1037dc628a5c3e2e (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / PROPG - Programa de Pós-Graduação / Com a necessidade de atender com qualidade a crescente demanda por energia eletrica, com poucas interrupcoes e com níıveis de tensao satisfatorios, e tendo em vista as restricoes ambientais existentes, que dificultam a implantacao de novos recursos aos sistemas de transmissao, como linhas, usinas, subestacoes, etc., as empresas de transmissao tem buscado otimizar os recursos existentes, operando os sistemas com menos folga o que, em alguns casos, pode ocasionar pequenas sobrecargas nas linhas. Nas estruturas atuais de operacao, acoes corretivas usualmente aplicadas ao alıvio dos sistemas de transmissao, como alteracoes nos nıveis de geracao e corte de cargas, fazem parte das atribuicoes do operador do sistema e estao fora do escopo de acao das empresas transmissoras que podem, contudo, alterar as condicoes de operacao de seus dispositivos, como transformadores, compensadores, etc. Neste trabalho e apresentada uma proposta para o alıvio de pequenas sobrecargas em redes de transmissao com base no controle do fluxo reativo das linhas. As acoes corretivas sao determinadas com base na linearizacao dos parametros do sistema em torno de seu ponto de operacao inicial, solucionando-se um problema de programacao linear (PL) cuja funcao objetivo a ser minimizada e o produto entre o custo dos servicos de suporte de reativos prestados pelos dispositivos e o desvio do sistema de seu ponto de operacao inicial. Haja vista a grande quantidade de dispositivos instalados no sistema que podem fornecer servicos de suporte de reativos e que problemas relativos a potencia reativa sao solucionados localmente, e possıvel reduzir a quantidade de dispositivos “candidatos” a realizacao das acoes corretivas e, consequentemente, o numero de variaveis e restricoes no PL a ser solucionado... / The growing demand for electric power associated with the environmental limitations imposed to the expansion of power systems hamper the installation of new facilities, such as transmission lines, substations and power plants, and leads the transmission companies to optimize the existing resources. In consequence, transmission systems operate closer to their boundaries and small overloads may surge. In the deregulated operating environment, the standard overload relief procedures, based on generation redispatch and load shedding, are in charge of the system operator and cannot be performed by the transmission companies, which can, otherwise, modify the control parameters of the transmission system devices, such as transformers, shunt compensators, etc. An overload relief procedure based on reactive power control applicable to small disturbances is presented in this paper. The corrective actions are determined by linearizing the system parameters around the initial operating point and solving a linear problem (LP), that minimizes the product between the total cost of the reactive power support provided by the devices and the deviation of the system from its initial operating point. Considering that reactive sources are spread over the whole system and the solution for reactive power problems can be found locally, the set of devices to be applied for the corrective actions can be reduced and, consequently, the number of variables and constraints to be added to the LP problem. To accomplish that, linear sensitivity factors which relate the reactive flow variation in the overloaded line to the devices’ control parameters are applied and the “n” most effective devices to mitigate the overloads can be determined. In many market structures reactive power support is a mandatory service and, in some cases, it is not remunerated. However, despite the low cost of production of reactive power... (Complete abstract click electronic access below)

Page generated in 0.08 seconds