1

Aplicação da transformada Wavelet na análise da qualidade de energia em fornos elétricos a arco. / Application of wavelet transform for power quality analysis in electric arc furnace.

Cândido, Marcos Rogério 10 November 2008 (has links)
Neste trabalho, desenvolveu-se um novo método para a detecção e classificação dos distúrbios que afetam a qualidade de energia elétrica em sistemas elétricos industriais na presença de fornos elétricos a arco. Durante o processo de fusão dos fornos elétricos a arco, ocorrem diversos eventos que afetam o sistema elétrico ao qual estão inseridos, tendo como características: forma de onda do sinal de corrente altamente desequilibradas e com grande distorção devido aos harmônicos, efeitos de cintilação; bem como afundamento e elevação nos sinais de tensão. O método ora proposto foi aplicado a sinais reais, permitindo a detecção e classificação dos distúrbios múltiplos na forma de onda do sinal de tensão, proveniente da operação dos fornos elétricos a arco. Para tal, foi usada como base do algoritmo, uma técnica baseada na Transformada Wavelet, aplicada aos sinais não-estacionários de uma instalação industrial com três fornos elétricos a arco. / A new method for the detection and classification of the disturbances that affect the electric power quality in industrial electric systems with electric arc furnaces was developed in this work. During the fusion process of the electric arc furnaces, may occur several events that affect the electric system to which it is inserted may occur, having as characteristic: waveform of the signal of current highly unbalanced and with great distortion due to the harmonic, scintillation effects; as well as sag and swell in the voltage signals.The method proposed was applied to real signals, allowing the detection and classification of the multiple disturbances in the waveform of the voltage signal originating from the operation of the electric arc furnace. For this purpose, a technique based on Wavelet Transform will be used and applied to the not-stationary signals of an industrial installation with three electric arc furnaces.
2

Aplicação da transformada Wavelet na análise da qualidade de energia em fornos elétricos a arco. / Application of wavelet transform for power quality analysis in electric arc furnace.

Marcos Rogério Cândido 10 November 2008 (has links)
Neste trabalho, desenvolveu-se um novo método para a detecção e classificação dos distúrbios que afetam a qualidade de energia elétrica em sistemas elétricos industriais na presença de fornos elétricos a arco. Durante o processo de fusão dos fornos elétricos a arco, ocorrem diversos eventos que afetam o sistema elétrico ao qual estão inseridos, tendo como características: forma de onda do sinal de corrente altamente desequilibradas e com grande distorção devido aos harmônicos, efeitos de cintilação; bem como afundamento e elevação nos sinais de tensão. O método ora proposto foi aplicado a sinais reais, permitindo a detecção e classificação dos distúrbios múltiplos na forma de onda do sinal de tensão, proveniente da operação dos fornos elétricos a arco. Para tal, foi usada como base do algoritmo, uma técnica baseada na Transformada Wavelet, aplicada aos sinais não-estacionários de uma instalação industrial com três fornos elétricos a arco. / A new method for the detection and classification of the disturbances that affect the electric power quality in industrial electric systems with electric arc furnaces was developed in this work. During the fusion process of the electric arc furnaces, may occur several events that affect the electric system to which it is inserted may occur, having as characteristic: waveform of the signal of current highly unbalanced and with great distortion due to the harmonic, scintillation effects; as well as sag and swell in the voltage signals.The method proposed was applied to real signals, allowing the detection and classification of the multiple disturbances in the waveform of the voltage signal originating from the operation of the electric arc furnace. For this purpose, a technique based on Wavelet Transform will be used and applied to the not-stationary signals of an industrial installation with three electric arc furnaces.
3

Estruturas de memória longa em variáveis econômicas : da análise de integração e co-integração fracionária à análise de ondaletas / Long memory structures in economic variables

Marques, Guilherme de Oliveira Lima Cagliari 09 April 2008 (has links)
Os modelos ARFIMA de memória longa mostraram-se nesse trabalho mais versáteis à análise da persistência em séries temporais em comparação aos modelos ARIMA. As funções impulso-resposta dos modelos de integração fracionária indicam que essa classe de modelos capta mais adequadamente as informações contidas nas baixas freqüências das séries e, portanto, estes modelos são mais capacitados para avaliar como os choques econômicos são acomodados no médio e longo prazo. Os estudos simulatórios mostraram que os testes de raiz unitária aplicados a processos com memória longa possuem baixo poder, e que os estimadores por máxima verossimilhança e os baseados no espectro de ondaletas são eficientes para estimar o parâmetro de integração fracionária. Os estudos empíricos encontraram componentes altamente persistentes nas séries brasileiras do produto, desemprego e consumo. A análise de co-integração fracionária refutou os resultados do arcabouço I(1)-I(0) que sugerem a não co-integração entre as séries consumo das famílias e renda disponível. A variabilidade relativa dessas séries foi analisada por meio da análise em multiresolução de ondaletas. Concluiu-se que, nas baixas escalas, a variabilidade entre as séries varia em função da escala temporal envolvida. A doutrina da paridade do poder de compra com dados brasileiros foi revisitada por meio da análise de co-integração fracionária. / The long-memory ARFIMA models proved to be more versatile in this study to the analysis of endurance in time series compare to the ARIMA models. The impulse-response functions of the fractionally integrated models indicate that this class of models more adequately gathers the data enclosed in the low frequencies of the series and thus these models are more befitted to evaluate how economic shocks are settled in the medium and long terms. Simulation studies unveiled that the unit root tests applied to long-memory processes have low power, and that the maximum likelihood estimators as well as those based on wavelet spectrum are efficient in estimating the fractional difference parameter. Empirical studies have found highly persistent components in the Brazilian series of the product, unemployment and consumption. The fractional co-integration analysis rebutted the results of the I(1)-I(0) framework, which suggest the non co-integration between the series of families\' consumption and the disposable income. The relative variability of these series was investigated through a wavelet multiresolution analysis. It was concluded that, in small scales, the variability between the series changes according to the time scale involved. The Purchasing Power Parity doctrine with Brazilian data has been revisited through the fractional co-integration analysis.
4

Estruturas de memória longa em variáveis econômicas : da análise de integração e co-integração fracionária à análise de ondaletas / Long memory structures in economic variables

Guilherme de Oliveira Lima Cagliari Marques 09 April 2008 (has links)
Os modelos ARFIMA de memória longa mostraram-se nesse trabalho mais versáteis à análise da persistência em séries temporais em comparação aos modelos ARIMA. As funções impulso-resposta dos modelos de integração fracionária indicam que essa classe de modelos capta mais adequadamente as informações contidas nas baixas freqüências das séries e, portanto, estes modelos são mais capacitados para avaliar como os choques econômicos são acomodados no médio e longo prazo. Os estudos simulatórios mostraram que os testes de raiz unitária aplicados a processos com memória longa possuem baixo poder, e que os estimadores por máxima verossimilhança e os baseados no espectro de ondaletas são eficientes para estimar o parâmetro de integração fracionária. Os estudos empíricos encontraram componentes altamente persistentes nas séries brasileiras do produto, desemprego e consumo. A análise de co-integração fracionária refutou os resultados do arcabouço I(1)-I(0) que sugerem a não co-integração entre as séries consumo das famílias e renda disponível. A variabilidade relativa dessas séries foi analisada por meio da análise em multiresolução de ondaletas. Concluiu-se que, nas baixas escalas, a variabilidade entre as séries varia em função da escala temporal envolvida. A doutrina da paridade do poder de compra com dados brasileiros foi revisitada por meio da análise de co-integração fracionária. / The long-memory ARFIMA models proved to be more versatile in this study to the analysis of endurance in time series compare to the ARIMA models. The impulse-response functions of the fractionally integrated models indicate that this class of models more adequately gathers the data enclosed in the low frequencies of the series and thus these models are more befitted to evaluate how economic shocks are settled in the medium and long terms. Simulation studies unveiled that the unit root tests applied to long-memory processes have low power, and that the maximum likelihood estimators as well as those based on wavelet spectrum are efficient in estimating the fractional difference parameter. Empirical studies have found highly persistent components in the Brazilian series of the product, unemployment and consumption. The fractional co-integration analysis rebutted the results of the I(1)-I(0) framework, which suggest the non co-integration between the series of families\' consumption and the disposable income. The relative variability of these series was investigated through a wavelet multiresolution analysis. It was concluded that, in small scales, the variability between the series changes according to the time scale involved. The Purchasing Power Parity doctrine with Brazilian data has been revisited through the fractional co-integration analysis.
5

Análise da assinatura magnética resultante de faltas em sistemas elétricos via wavelets. / Electrical system fault based on the resulting magnetic signature by Wavelet.

Sevegnani, Francisco Xavier 21 August 2009 (has links)
Apresenta-se uma metodologia que tem como base a análise de campos magnéticos no monitoramento da qualidade da energia de sistemas elétricos. Em particular, são avaliados os aspectos referentes à detecção de faltas em sistemas elétricos. Diferente do processo de monitoração tradicional, cujos sensores precisam estar fisicamente conectados aos circuitos analisados, propõe-se estudar a viabilidade da utilização dos sinais provenientes da assinatura magnética resultante no exame do desempenho dos sistemas elétricos. Ressalta-se, assim, a característica não invasiva deste processo. Em uma primeira instância, simulações numéricas e medidas experimentais são usadas para estimar a validade deste método. Com base em valores das correntes de falta fase-terra, relacionados a configurações reais de sistemas de distribuição, provenientes de simulações numéricas e disponibilizadas na literatura, são calculados os campos magnéticos em regiões pré-selecionadas próximas às linhas. A seguir, aplicam-se os conceitos relacionados a wavelets no tratamento dos sinais resultantes. É nesta etapa que, por meio da decomposição da assinatura magnética correspondente, serão obtidos os dados necessários para se correlacionar os componentes dos sinais ao diagnóstico das faltas, nos sistemas elétricos. A Análise de múltirresolução é aplicada. Além destes resultados teóricos, aqueles provenientes de uma bancada experimental são examinados. Algumas configurações canônicas foram pré-selecionadas, visando estudar a eventual influência dos aspectos geométricos nos resultados relacionados à decomposição do sinal em análise. Embora métodos analíticos pudessem ser empregados na determinação da assinatura magnética resultante, os métodos numéricos, tais como o método dos elementos finitos, foram utilizados visando agilizar a obtenção de resultados teóricos a serem avaliados. Da mesma forma, aplicativos já disponibilizados comercialmente foram utilizados na decomposição dos sinais. Esta metodologia foi aplicada, também, para identificar faltas, aplicando-se a análise da variância para os diversos níveis do detalhe wavelet. A validação da metodologia foi feita pela comparação entre os resultados simulados e obtidos experimentalmente. / A methodology based on the analysis of magnetic fields for monitoring the quality of energy in electrical systems is presented herein. Aspects referring to fault detection in electrical systems in particular are evaluated. Contrary to the traditional monitoring process, in which sensors must be physically linked to the circuits under analysis, the results are presented from a feasibility study on the use of signals arising from the resulting magnetic signature by means of the electrical systems analysis. Thus the non-invasive characteristic of this process should be pointed out. First, numerical simulations and experimental measures were used to estimate the validity of this method. Based on values of the current of phase-earth fault related to actual features of the distribution systems and derived from numeric simulations found in the literature, the magnetic fields, in pre-established regions, were calculated. Following this, the concepts related to wavelets in the treatment of resulting signals were applied. It is in this phase that, by means of the decomposition of the corresponding magnetic signature, the data necessary to correlate the signal components for the diagnosis of faults in electrical systems were obtained. A Multiresolution Analysis (MRA) was applied. In addition to these theoretical results, the results from a laboratory workbench were also examined. Some canonical features were pre-selected, aiming to study the influence of geometric aspects on the results related to the signal decomposition analyzed. Although analytical methods could be employed to determine the resulting magnetic signature, numerical methods, such as the finite element method, were used to expedite obtaining the theoretical results to be analyzed. Likewise, commercial software was also used for the decomposition of signals. This methodology was validated by comparing the measured and simulated magnetic flux density. This methodology was also applied to identify and classify faults by means of the variance curve towards the wavelet detail.
6

Análise da assinatura magnética resultante de faltas em sistemas elétricos via wavelets. / Electrical system fault based on the resulting magnetic signature by Wavelet.

Francisco Xavier Sevegnani 21 August 2009 (has links)
Apresenta-se uma metodologia que tem como base a análise de campos magnéticos no monitoramento da qualidade da energia de sistemas elétricos. Em particular, são avaliados os aspectos referentes à detecção de faltas em sistemas elétricos. Diferente do processo de monitoração tradicional, cujos sensores precisam estar fisicamente conectados aos circuitos analisados, propõe-se estudar a viabilidade da utilização dos sinais provenientes da assinatura magnética resultante no exame do desempenho dos sistemas elétricos. Ressalta-se, assim, a característica não invasiva deste processo. Em uma primeira instância, simulações numéricas e medidas experimentais são usadas para estimar a validade deste método. Com base em valores das correntes de falta fase-terra, relacionados a configurações reais de sistemas de distribuição, provenientes de simulações numéricas e disponibilizadas na literatura, são calculados os campos magnéticos em regiões pré-selecionadas próximas às linhas. A seguir, aplicam-se os conceitos relacionados a wavelets no tratamento dos sinais resultantes. É nesta etapa que, por meio da decomposição da assinatura magnética correspondente, serão obtidos os dados necessários para se correlacionar os componentes dos sinais ao diagnóstico das faltas, nos sistemas elétricos. A Análise de múltirresolução é aplicada. Além destes resultados teóricos, aqueles provenientes de uma bancada experimental são examinados. Algumas configurações canônicas foram pré-selecionadas, visando estudar a eventual influência dos aspectos geométricos nos resultados relacionados à decomposição do sinal em análise. Embora métodos analíticos pudessem ser empregados na determinação da assinatura magnética resultante, os métodos numéricos, tais como o método dos elementos finitos, foram utilizados visando agilizar a obtenção de resultados teóricos a serem avaliados. Da mesma forma, aplicativos já disponibilizados comercialmente foram utilizados na decomposição dos sinais. Esta metodologia foi aplicada, também, para identificar faltas, aplicando-se a análise da variância para os diversos níveis do detalhe wavelet. A validação da metodologia foi feita pela comparação entre os resultados simulados e obtidos experimentalmente. / A methodology based on the analysis of magnetic fields for monitoring the quality of energy in electrical systems is presented herein. Aspects referring to fault detection in electrical systems in particular are evaluated. Contrary to the traditional monitoring process, in which sensors must be physically linked to the circuits under analysis, the results are presented from a feasibility study on the use of signals arising from the resulting magnetic signature by means of the electrical systems analysis. Thus the non-invasive characteristic of this process should be pointed out. First, numerical simulations and experimental measures were used to estimate the validity of this method. Based on values of the current of phase-earth fault related to actual features of the distribution systems and derived from numeric simulations found in the literature, the magnetic fields, in pre-established regions, were calculated. Following this, the concepts related to wavelets in the treatment of resulting signals were applied. It is in this phase that, by means of the decomposition of the corresponding magnetic signature, the data necessary to correlate the signal components for the diagnosis of faults in electrical systems were obtained. A Multiresolution Analysis (MRA) was applied. In addition to these theoretical results, the results from a laboratory workbench were also examined. Some canonical features were pre-selected, aiming to study the influence of geometric aspects on the results related to the signal decomposition analyzed. Although analytical methods could be employed to determine the resulting magnetic signature, numerical methods, such as the finite element method, were used to expedite obtaining the theoretical results to be analyzed. Likewise, commercial software was also used for the decomposition of signals. This methodology was validated by comparing the measured and simulated magnetic flux density. This methodology was also applied to identify and classify faults by means of the variance curve towards the wavelet detail.