• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Validação do infravermelho médio para leite de cabras em equipamento calibrado para leite de vacas

SILVA, Laís Marinho de Melo Marques da 26 February 2016 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2017-06-14T13:27:25Z No. of bitstreams: 1 Lais Marinho de Melo Marques da Silva.pdf: 556632 bytes, checksum: a93b208014fc7d482c6a82b220e42d79 (MD5) / Made available in DSpace on 2017-06-14T13:27:25Z (GMT). No. of bitstreams: 1 Lais Marinho de Melo Marques da Silva.pdf: 556632 bytes, checksum: a93b208014fc7d482c6a82b220e42d79 (MD5) Previous issue date: 2016-02-26 / This study aimed to evaluate the use of electronic equipment based on mid-infrared calibrated with cow's milk, to analyze the protein, fat, total solids and non-fatty solids parameters from goat’s milk. We have collected 95 samples of raw goat's milk from two different dairy shops, of which the protein, fat, total solids and non-fatty solids components were analyzed under standard and electronic method. The obtained data were submitted to variance analysis and further performed the correlation and regression analysis, being the standard method considered as dependent variable and the electronic method as independent variable. The results showed that there was no significant difference between the averages of the two treatments in the analysis of fat, total solids and non-fatty solids (P> 0.01). However, there was significant difference in protein analysis between both methods (P <0.01). High, positive and significant correlation was found (P <0.0001) between the two methods for protein, fat, total solids and non-fatty solids. After regression analysis, equations were obtained for the different parameters tested, which showed high coefficient of determination. The R2 was 0.8530, 0.8574, 0.9486 and 0,6679 for protein, fat, total solids and non-fatty solids, respectively. Thus, the use of electronic equipment calibrated with cow's milk can be used in the analysis of fat, total solids and non-fatty solids from goat milk, although a correction equation for the analysis of protein is required. / O presente estudo teve como objetivo validar o uso de equipamento eletrônico baseado no infravermelho médio calibrado com leite de vaca, para análise dos parâmetros proteína, gordura, extrato seco total (EST) e extrato seco desengordurado (ESD) do leite de cabra. Foram coletadas 95 amostras de leite de cabra cru de dois laticínios distintos, onde os componentes proteína, gordura, EST e ESD foram analisados sob o método padrão e o eletrônico. Os dados obtidos foram submetidos à análise de variância e realizadas análises de correlação e regressão, sendo o método padrão considerado como variável dependente e o método eletrônico como variável independente. Os resultados obtidos demonstraram que não houve diferença significativa entre as médias dos dois tratamentos na análise de gordura, EST e ESD (P>0,01). Porém, houve diferença significativa na análise de proteína entre os dois métodos (P<0,01). Foi verificado correlação alta, positiva e significativa (P<0,0001) entre os dois métodos para proteína, gordura, EST e ESD. Após a análise de regressão, foram obtidas equações para os diferentes parâmetros analisados, que demonstraram coeficiente de determinação alto. O valor do R2 obtido para proteína, gordura, EST e ESD foram 0,8530, 0,8574, 0,9486 e 0,6679, respectivamente. Concluiu-se que a utilização do equipamento eletrônico calibrado com leite de vaca, pode ser utilizado na análise de gordura, EST e ESD do leite de cabra, havendo necessidade de uma equação de correção para a análise da proteína.

Page generated in 0.0423 seconds