• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sobre a instabilidade local de perfis \"I\" de aço em situação de incêndio. / On the local buckling of steel \"I\" profiles in a fire situation.

Calobrezi, Gian Carlo 13 February 2019 (has links)
No que se refere as estruturas, apesar de os esforços resistentes de cálculo (força axial de compressão e momento fletor) em situação de incêndio estarem previstos nas prescrições normativas da ABNT, Eurocode, AISC e outros documentos pertinentes ao tipo de análise, o efeito da instabilidade local no esforço resistente das seções dos perfis \"I\" de aço soldados e laminados ainda não se encontra bem delineado em função da elevação de temperatura, sendo que as normas técnicas acabam superestimando o referido efeito, conduzindo a um dimensionamento antieconômico. Devido às vantagens associadas ao pequeno peso próprio e à eficiência de perfis \"I\" de aço, esbeltos, esses elementos são amplamente utilizados na construção civil. Entretanto, as regras atuais de dimensionamento em situação de incêndio das normas técnicas são imprecisas, podendo inviabilizar a utilização de perfis esbeltos para essa finalidade. A presente pesquisa teve como objetivo o estudo aprofundado do efeito da instabilidade local em perfis \"I\" de aço no dimensionamento em situação de incêndio. Foi realizada modelagem computacional via SAFIR, programa de computador de análise termestrutural, com base no Método dos Elementos Finitos (MEF), prospecção de resultados e comparação dos esforços resistentes advindos da aplicação das prescrições normativas àqueles obtidos via MEF. Para perfis de catálogos comerciais ou normatizados, os resultados obtidos permitem identificar que as normas técnicas ABNT NBR 14.323:2013 e Eurocode 3 Parte 1-2 são conservadoras para pilares na faixa de temperatura entre 600,00 ºC e 800,00 ºC e vigas na faixa de temperatura entre 400,00 ºC e 800,00 ºC, subestimando os resultados. Ademais, foi possível verificar que as normas técnicas não são conservadoras em geral, sendo que para algumas circunstâncias os resultados são satisfatórios ou até mesmo contra a segurança. Neste trabalho, mostrou-se a necessidade de aprimoramentos em termos de precisão nas normas técnicas vigentes no que se refere à instabilidade local em situação de incêndio. / Regarding structures, although fire resistance efforts (axial compression and bending moment) are predicted according to the ABNT, Eurocode, AISC and other documents related to that kind of analysis, the local buckling effect on resistance of steel \"I\" welded and hot rolled cross sections in function of temperature requires further studies, being that the technical references overestimate its value leading to a non-economical design. Considering slender \"I\"-shaped profiles advantages linked to its lightweight and effectiveness, those materials are widely used in civil construction. However, actual design rules in fire situation are imprecise, being able to make unfeasible the usage of slender cross sections. The present research aimed a comprehensive study of the local buckling effect on steel \"I\" cross sections in fire situation. It has been conducted computational modeling through SAFIR, specific software of thermostructural analysis, based on the Finite Element Method (FEM), prospection of results and comparison of the resistance efforts obtained from the application of the normative prescriptions and the ones obtained through FEM. For commercial and standardized catalog profiles, obtained results allow to identify that ABNT NBR 14.323:2013 and Eurocode 3 Part 1-2 are conservative for temperature range between 600,00 ºC and 800,00 ºC for columns and for temperature range between 400,00 ºC to 800,00 ºC for beams, underestimating the results. In addition, it was possible to verify that the standards are not conservative at all, being that for some circumnstances results are satisfactory or even against safety. In the present work, it was exhibited the need of enhancements in terms of precision on current standards regarding local buckling at elevated temperatures.
2

Análise de vigas mistas de aço e concreto semicontí­nuas em situação de incêndio. / Composite steel and concrete semicontinuous beams analysis under fire.

Romagnoli, Lucas Coscia 21 June 2018 (has links)
Na Dissertação de Mestrado foi realizado um estudo sobre o comportamento de vigas mistas de aço e concreto biapoiadas sob iteração completa, compostas por perfis classificados como compactos em situação de incêndio. Apesar de ditas biapoiadas, a ideia principal da Dissertação é considerar, na análise em situação de incêndio, a reserva de capacidade existente nas extremidades dessas vigas, usualmente desprezada no dimensionamento à temperatura ambiente, provinda da continuidade da armadura longitudinal negativa presente na laje de concreto, sendo possível dispensar o revestimento contra fogo nesses elementos. Serão abordados, de início, os métodos de dimensionamento ao Estado-Limite Último de vigas mistas à temperatura ambiente, a fim de explicar o comportamento estrutural desse tipo de elemento, dando base para a posterior análise térmica. A análise térmica foi realizada, em uma primeira etapa, por métodos simplificados segundo normas vigentes e tomando hipóteses simplificadoras em que se desprezam esforços indiretos provocados pela dilatação térmica e gradiente térmico, sendo possível aplicar os conceitos no dia a dia de projeto. Numa segunda etapa foi realizada análise termestrutural com modelos numéricos para estudar o comportamento e colapso da viga, sendo os resultados suficientes para validar os valores de TRF encontrados por análise simplificada seguindo métodos normativos. Como conclusão, o ganho de capacidade estrutural da viga, proporcionado pela adoção da ligação mista no apoio, foi suficiente para situações de TRRFs entre 15 min e 21 min, no caso de perfis mais leves, com geometria própria para serem utilizados como vigas de piso de edifícios. Análises mostraram que não é possível justificar a ausência de revestimento contra incêndio para TRRFs de 30 min ou superiores. Tempos inferiores podem ser adotados de acordo com o denominado método do tempo equivalente, limitado a 15 min e são mais usuais para edificações de pequeno porte. / A study will be carried out on the behavior of simply supported, full interaction composite steel and concrete beams composed by compact profiles in fire situation. Despite being designed as simply supported, the main idea is to consider, in the fire situation analysis, the moment resistance capacity reserve on the beam supports, usually neglected during room temperature design, due to the upper longitudinal reinforcement present in the concrete slab, being possible to dispense fireproof coating in these elements. First, room temperature design procedures of composite beams will be approached in order to explain the structural behavior of this type of elements, providing a basis for subsequent thermal analysis. The thermal analysis will be carried out, in a first stage, by simplified methods according to design procedures and adopting simplifying hypotheses in which indirect stresses caused by thermal expansion and thermal gradient are neglected, being possible to apply those concepts in structural design offices. In a second step, thermal stress analyses were performed with aid of numerical models to study the structural behavior and collapse time of the beam. The results were sufficient to validate the fire resistance time values found by the simplified analysis following design methods. As a conclusion, the structural capacity increase of the beam, provided by the adoption of the composite connection at the support in case of lighter steel profiles usually chosen to be used as buildings floor beams, was sufficient for situations of standard fire resistance requirements between 15 min and 21 min. Analyzes have shown that it is not possible to justify the absence of fire resistant coating for standard fire resistance requirements of 30 min or higher. Lower times can be adopted according to the so-called equivalent time method, limited to 15 min, which are more common for small buildings.
3

Análise de vigas mistas de aço e concreto semicontí­nuas em situação de incêndio. / Composite steel and concrete semicontinuous beams analysis under fire.

Lucas Coscia Romagnoli 21 June 2018 (has links)
Na Dissertação de Mestrado foi realizado um estudo sobre o comportamento de vigas mistas de aço e concreto biapoiadas sob iteração completa, compostas por perfis classificados como compactos em situação de incêndio. Apesar de ditas biapoiadas, a ideia principal da Dissertação é considerar, na análise em situação de incêndio, a reserva de capacidade existente nas extremidades dessas vigas, usualmente desprezada no dimensionamento à temperatura ambiente, provinda da continuidade da armadura longitudinal negativa presente na laje de concreto, sendo possível dispensar o revestimento contra fogo nesses elementos. Serão abordados, de início, os métodos de dimensionamento ao Estado-Limite Último de vigas mistas à temperatura ambiente, a fim de explicar o comportamento estrutural desse tipo de elemento, dando base para a posterior análise térmica. A análise térmica foi realizada, em uma primeira etapa, por métodos simplificados segundo normas vigentes e tomando hipóteses simplificadoras em que se desprezam esforços indiretos provocados pela dilatação térmica e gradiente térmico, sendo possível aplicar os conceitos no dia a dia de projeto. Numa segunda etapa foi realizada análise termestrutural com modelos numéricos para estudar o comportamento e colapso da viga, sendo os resultados suficientes para validar os valores de TRF encontrados por análise simplificada seguindo métodos normativos. Como conclusão, o ganho de capacidade estrutural da viga, proporcionado pela adoção da ligação mista no apoio, foi suficiente para situações de TRRFs entre 15 min e 21 min, no caso de perfis mais leves, com geometria própria para serem utilizados como vigas de piso de edifícios. Análises mostraram que não é possível justificar a ausência de revestimento contra incêndio para TRRFs de 30 min ou superiores. Tempos inferiores podem ser adotados de acordo com o denominado método do tempo equivalente, limitado a 15 min e são mais usuais para edificações de pequeno porte. / A study will be carried out on the behavior of simply supported, full interaction composite steel and concrete beams composed by compact profiles in fire situation. Despite being designed as simply supported, the main idea is to consider, in the fire situation analysis, the moment resistance capacity reserve on the beam supports, usually neglected during room temperature design, due to the upper longitudinal reinforcement present in the concrete slab, being possible to dispense fireproof coating in these elements. First, room temperature design procedures of composite beams will be approached in order to explain the structural behavior of this type of elements, providing a basis for subsequent thermal analysis. The thermal analysis will be carried out, in a first stage, by simplified methods according to design procedures and adopting simplifying hypotheses in which indirect stresses caused by thermal expansion and thermal gradient are neglected, being possible to apply those concepts in structural design offices. In a second step, thermal stress analyses were performed with aid of numerical models to study the structural behavior and collapse time of the beam. The results were sufficient to validate the fire resistance time values found by the simplified analysis following design methods. As a conclusion, the structural capacity increase of the beam, provided by the adoption of the composite connection at the support in case of lighter steel profiles usually chosen to be used as buildings floor beams, was sufficient for situations of standard fire resistance requirements between 15 min and 21 min. Analyzes have shown that it is not possible to justify the absence of fire resistant coating for standard fire resistance requirements of 30 min or higher. Lower times can be adopted according to the so-called equivalent time method, limited to 15 min, which are more common for small buildings.

Page generated in 0.0915 seconds