• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • Tagged with
  • 11
  • 11
  • 11
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelo de análise econômica de projetos de investimento em shopping centers:aplicação do método de Monte Carlo e a proposição de um método para dimensionamento das áreas do shopping/

Cassas, M. P. January 2015 (has links) (PDF)
Dissertação (Mestrado em Engenharia Mecânica) - Centro Universitário FEI, São Bernardo do Campo, 2015
2

Blocos de ancoragem : metodologia dedimensionamento

Germer, Alex de Araujo 22 July 2018 (has links)
Orientador: Gilson B. Fernandes / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-22T02:34:43Z (GMT). No. of bitstreams: 1 Germer_AlexdeAraujo.pdf: 7897871 bytes, checksum: 70ce778ff07d0e0c7140bd4034bb5e29 (MD5) Previous issue date: 1996 / Resumo: Este trabalho apresenta uma metodologia de dimensionamento de blocos de ancoragem. Os blocos de ancoragem são estruturas em concreto armado, utilizadas principalmente em obras de usinas hidrelétricas, e que, apesar de sua importância como elemento estrutural responsável pela estabilidade dos condutos, onde será conduzida a água para as turbinas, não dispõe de um modelo de cálculo conhecido e difundido no meio técnico. Mesmo na literatura disponível sobre o assunto, os autores restringem-se a parte do problema que envolve o dimensionamento desta estrutura, limitando-se somente a apresentação das forças atuantes. Buscou-se aqui transmitir de forma detalhada, qual a função desta estrutura, quais são suas particularidades, onde devem ser previstos e principalmente, como devem ser dimensionadas / Abstract: This work proposes a design methodology for anchor blocks. The anchor blocks are reinforced concrete structures. They are mainlyused in hidro-electric power stations, and despite oftheir importance as structural elements for the pipe stability, there is not a known model for designo In the technical literature, the authors are limited to the structure design' s problem, presenting only the acting loads. The aim of this study was to describe in details the function of this kind of structure, which are their particularties, where they are conviníent and, the most important, how they must be designed. / Universidade Estadual de Campi / Estruturas / Mestre em Engenharia Civil
3

Avaliação experimental dos metodos de prevenção de fissuras na interface alvenaria de vedação e pilar de concreto / Experimental analysis of methods of prevention of splitting in the fair-faced masonry and concrete column

Tramontin, Andre Penteado 07 August 2005 (has links)
Orientador: Armando Lopes Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenhaira Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-05T00:18:16Z (GMT). No. of bitstreams: 1 Tramontin_AndrePenteado_M.pdf: 3029877 bytes, checksum: d1ddf2e0086571a9cb41c8abef993f75 (MD5) Previous issue date: 2005 / Resumo: As fissuras na interface alvenaria-estrutura são comuns e pouco se conhece a respeito da sua ocorrência, embora sejam freqüentes, especialmente as que aparecem na ligação alvenaria-pilar de concreto. O objetivo deste trabalho foi estudar a melhor técnica de ancoragem entre alvenaria-estrutura, avaliando sua eficiência no combate a esse tipo de fissura. Foram utilizados para a elaboração dos ensaios, além dos materiais usados na alvenaria de vedação (bloco cerâmico, argamassa etc), diferentes materiais de ancoragem (tela metálica eletrosoldada e barras de aço) e dispositivos de ligação (adesivo epóxi, pinos, arruelas e cantoneira), analisando-se assim o melhor conjunto do ponto de vista técnico. Foram feitos ensaios de caracterização dos materiais e de arrancamento à tração direta, até a ocorrência da primeira fissura visível a olho nu. Concluiu-se finalmente que a tela metálica eletrosoldada galvanizada malha 15 x 15 mm e diâmetro do fio 1,65 mm, sem cantoneira e com tratamento de chapisco com adesivo acrílico no pilarete foi a melhor técnica de ancoragem para a prevenção do aparecimento de fissuras na interface alvenaria de vedação e pilar de concreto / Abstract: The splitting of the fair-faced masonry-structure are very usual but it is not wellknown the reason of its occurrence, although they are frequent, specially the ones that appear in the linking of the masonry-concrete column. The purpouse of this work was to study the best anchorage technique between masonrystructure, being evaluated its efficiency to prevent this type of splitting. Beyond the materials that are usually used for masonry (ceramic block, mortar etc), changeable materials of anchorage (stell welded tie and steel wire) and apparatus of linking (adhesive epoxy, bolts, washers and angle-steel) were used, analyzing the best combination for the technical view. Tests of characterization of the materials and the pullout test were made, until the occurrence of the first splitting visible by naked eye. Finally, it was concluded that the metallic wall tie, 15 x 15 mm and the diameter of wire 1,65 mm, without angle-steel and with mortar with acrylic adhesive in the concrete column was the best anchorage technique for to prevent occurrence of splitting in the fair-faced masonry-concrete structure / Mestrado / Edificações / Mestre em Engenharia Civil
4

Influencia do comprimento de transpasse e do confinamento na emenda da armadura em vigas de concreto de alta resistencia

Lintz, Flavio Henrique 26 February 2003 (has links)
Orientador: Vitor Antonio Ducatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T17:23:35Z (GMT). No. of bitstreams: 1 Lintz_FlavioHenrique_M.pdf: 5548645 bytes, checksum: b08c319a5e800db3dc593a74c6b76398 (MD5) Previous issue date: 2003 / Resumo: O presente trabalho trata do estudo do comportamento da emenda por traspasse da armadura longitudinal em vigas sub-armadas de concreto de alta resistência submetidas à flexão. As emendas foram posicionadas na região de momento constante da viga onde não existe a influência das tensões de cisalhamento. Foi observado o comportamento dos mecanismos de aderência que fornecem os tipos de ruptura do cobrimento de concreto e as resistências de ancoragem e de emenda das barras. Os fatores que afetam a emenda por traspasse são apresentados numa extensa revisão bibliográfica. Esta revisão abrange os principais trabalhos, sobre a resistência de aderência, publicados desde o início do século vinte até os dias de hoje. Este imenso banco de dados (cerca de mil resultados de ensaios de vigas) contribuiu para a formulação e, conseqüente evolução, das equações das emendas e das ancoragens nos concretos armados de resistência normal e de alta resistência, as quais vem sendo adaptadas e utilizadas nas normas e códigos internacionais de dimensionamento do concreto. Neste trabalho são ensaiadas dez vigas com emenda por traspasse. Procurou-se constatar a influência do comprimento de emenda e da presença da armadura transversal de confinamento sobre a resistência da emenda. Os resultados de ensaios foram comparados com os valores fornecidos pelas equações empíricas apresentadas na literatura internacional e pelas equações constantes nas diversas normas sobre o assunto. Desta comparação chegou-se à conclusão que os resultados obtidos nos ensaios desta dissertação ficaram próximos daqueles fornecidos pelas referidas equações / Abstract: This dissertation deals with the study of the behavior of lap splices of the longitudinal reinforcement in under-reinforced high strength concrete beams subjected to plain bending. The splices are positioned in the region of constant moment of the beam span where there is no influence of the shear stresses. It was observed the bond mechanisms performance that provide for the concrete cover rupture patterns and the development and lap splice strengths. The last developed equations and factors that affect the anchorage and lap splice strengths are discussed in a comprehensive previous studies report. This report comprises the major publications on bond strength from the seventies to nowadays. This large data bank (about thousand beam test results) has contributed to the formulation and, consequently to evolution of the anchorage and splice length equations in ordinary and high strength reinforced concrete, which have been adapted and utilized in the international building codes. This dissertation reports and discusses ten beam splice test results. The objectives were verifying the influences of splice length and of the transversal reinforcement (stirrups) on bond strength. The test results were compared with the values predicted by empirical equations reached in the international literature and the equations in several codes. From these comparisons one concluded that the results obtained through the experimental part of this work rested close to the values provided by the mentioned equations / Mestrado / Edificações / Mestre em Engenharia Civil
5

Emenda por traspasse de barras de nucleo octogonal em vigas a flexão

Sartori, Marcos 03 August 2018 (has links)
Orientador: Vitor Antonio Ducatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T18:05:29Z (GMT). No. of bitstreams: 1 Sartori_Marcos_M.pdf: 2010421 bytes, checksum: 73e14f04533e1a739a2508bacf449852 (MD5) Previous issue date: 2003 / Mestrado
6

Comprimento de emenda por traspasse da armadura de flexão em vigas de concreto de alta resistencia

Carvalho, Marcos Funchal Nunes de 03 August 2018 (has links)
Orientador : Vitor Antonio Ducatti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T14:46:39Z (GMT). No. of bitstreams: 1 Carvalho_MarcosFunchalNunesde_M.pdf: 1775244 bytes, checksum: 77625ceb20a2ebf36c4fe249582ac08a (MD5) Previous issue date: 2002 / Mestrado
7

Estruturas portuárias: distribuição de esforços na infraestrutura devidos à amarração e atracação de embarcações

COMIN, Cristiano 26 March 2015 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T12:25:52Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstruturasPortuariasDistribuicao.pdf: 4967384 bytes, checksum: eb4c928c4c4bdabdcc2b47345e650682 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-17T16:36:15Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstruturasPortuariasDistribuicao.pdf: 4967384 bytes, checksum: eb4c928c4c4bdabdcc2b47345e650682 (MD5) / Made available in DSpace on 2017-03-17T16:36:15Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstruturasPortuariasDistribuicao.pdf: 4967384 bytes, checksum: eb4c928c4c4bdabdcc2b47345e650682 (MD5) Previous issue date: 2015-03-26 / O presente trabalho apresenta um estudo sobre as ações de projeto a serem consideradas no dimensionamento e análise de estruturas portuárias, no tocante às solicitações devidas à amarração e atracação de embarcações. O estudo buscou fazer um levantamento sobre o assunto na literatura nacional e internacional, com ênfase nas normas técnicas, em especial a NBR 9782/1987, a norma inglesa BS 6349 e a norma alemã EAU 2004, além das recomendações da Permanent International Association of Navigation Congresses (PIANC 2002) e de Mason (Jayme, 1982) em sua publicação Obras Portuárias. Foram estudados os métodos de cálculo dos esforços devido à amarração e atracação de embarcações segundo as diversas referências. Posteriormente realizou-se uma análise comparativa entre os resultados dos esforços obtidos com cada método de cálculo em um estudo de caso de uma estrutura, para o qual é analisada a sua infraestrutura. Os resultados demostraram uma notável dispersão entre os métodos utilizados nos cálculos, evidenciando uma grande influência do código normativo utilizado para as análises no dimensionamento de estruturas portuárias. / This work presents a study on the design loads due to mooring and berthing of vessels, regarding the design and analysis of port structures. A literature review was conducted, with emphasis on technical standards and codes, encompassing both national and international publications. More specifically, this study considered design recommendations of the Brazilian Standard NBR 9782/1987, the British Standard BS 6349 and the German Standard EAU 2004, in addition to the recommendations of the Permanent International Association of Navigation Congresses (PIANC 2002) and the analysis procedure proposed on the book “Port Works” by Jayme Mason (1982). The design procedures proposed by these different references regarding the computation of forces due to mooring and berthing of vessels where evaluated in this work. Later, a case study of a port’s substructure was carried on, and a comparative analysis of the results, obtained with each recommendation of the aforementioned publications, was performed. Results showed a remarkable dispersion, revealing a strong influence of the standard to be used in the design loads of port structures.
8

Estudo da interação solo-muro em concreto convencional, com resíduo de construção e demolição (RCD) e alvenaria de pedra / Study of the interaction soil-wall in conventional concrete, with residue of construction and demolition (RCD) and rock

Wallace Borges de Sá 28 March 2006 (has links)
Um dos principais problemas, na Região Metropolitana do Recife (RMR), nas encostas, é a ocupação antrópica desordenada, aumentando o número de moradias em áreas de risco. Uma das soluções para a estabilização das encostas é o uso da construção de estrutura de contenção como muro de arrimo. O ângulo de atrito solo-muro é um parâmetro fundamental para o dimensionamento. O seu valor é utilizado na avaliação dos empuxos ativo e passivo na análise de estabilidade do muro. A prática atual de projetos considera o valor do ângulo de atrito solo-muro como sendo igual ao ângulo de atrito do solo, uma parcela dele ou mesmo nulo a depender do caso. Valores experimentais para solos brasileiros não estão disponíveis na literatura. Desta forma, os projetos de muros de arrimo podem estar sendo dimensionados contra a segurança ou de forma antieconômica. Neste contexto na presente dissertação, foram realizados ensaios de cisalhamento direto em corpos de prova de solo e de outro material representativo de muros de arrimo (concreto convencional, concreto com agregado de resíduos de construção e demolição - RCD e rocha), com o objetivo de obter os ângulos de atrito interno do solo e do contato solomuro. Foram utilizados dois solos das encostas do Recife um arenoso (Ibura) e outro argiloso (Nova Descoberta). Foram avaliadas as rugosidades das superfícies em contato com os solos, para analisar sua influência na interação solo-muro. Os resultados obtidos são comparados com valores sugeridos na literatura, considerando a influência do solo e da rugosidade da superfície de contato. A relação entre o ângulo de atrito solo-muro e o ângulo de atrito do solo (ä/ö) varia de 3/4 a 1, com a Rugosidade Média, para o solo arenoso do Ibura e de 1/3 a 3/4 para o solo argiloso de Nova Descoberta. No solo arenoso, o atrito solo-muro tem menor influência da rugosidade da superfície de contato e tem valor muito próximo do ângulo de atrito interno do solo. No solo argiloso o atrito solo-muro é fortemente influenciado pela rugosidade da superfície de contato, e o seu valor varia de 1/3 a 3/4 do ângulo de atrito do solo / One of the main problems, in the Region Metropolitan of Recife (RMR), in the hillsides it is the disordered occupation, increasing the number of housings in risk areas. One of the solutions for the stabilization of the hillsides is the use of the construction of retained structure as support wall. The friction angle soil-wall is a basic parameter for the design of a support wall. Its value is used in the evaluation of the pushes active and passive in the analysis of stability of the wall. Practical the current one of projects in Brazil considers the value of the friction angle soil-wall as being equal to the angle of friction of the soil, a parcel of it or same zero to depend on the case. The values found in literature also indicate as estimative for this angle values that vary of zero to the angle of friction of the soil. Experimental values for Brazilian soils are not available in literature. Of this form the projects of support walls can be being designed against the security or of uneconomical form. In this context in the present dissertation tests of direct shear in specimens of composites of soil and another representative material of support walls had been carried through (conventional concrete, concrete with recycled aggregate of RCD and rock), with the objective to get the friction angle soil-wall. Two soils of the hillsides of Recife had been used (sandy and a other clayey one). The roughness of the surfaces in contact with soil had been evaluated, to analyze its influence in the interaction soil-wall. The gotten results are compared with values suggested in literature, having considered the influence of the soil and the roughness of the contact surface. The relation enters the friction angle soil-wall and the angle of friction of the ground (ä/ö) varies of 3/4 the 1, with the average roughness for the soil sandy of the Ibura and of 1/3 the 3/4 for the soil clayey of Nova Descoberta. In the soil sandy, the friction soil-wall has minor influence of the roughness of the faying surface and has value very next to the angle of internal friction of the soil. In the soil clayey the friction soil-wall strong is influenced by the roughness of the faying surface, and its value varies of 1/3 the 3/4 of the angle of friction of the soil
9

Estudo da interação solo-muro em concreto convencional, com resíduo de construção e demolição (RCD) e alvenaria de pedra / Study of the interaction soil-wall in conventional concrete, with residue of construction and demolition (RCD) and rock

Sá, Wallace Borges de 28 March 2006 (has links)
Made available in DSpace on 2017-06-01T17:57:27Z (GMT). No. of bitstreams: 1 wallace de sa.pdf: 2263305 bytes, checksum: a0c0a930c5ab441157930460e793e9b6 (MD5) Previous issue date: 2006-03-28 / One of the main problems, in the Region Metropolitan of Recife (RMR), in the hillsides it is the disordered occupation, increasing the number of housings in risk areas. One of the solutions for the stabilization of the hillsides is the use of the construction of retained structure as support wall. The friction angle soil-wall is a basic parameter for the design of a support wall. Its value is used in the evaluation of the pushes active and passive in the analysis of stability of the wall. Practical the current one of projects in Brazil considers the value of the friction angle soil-wall as being equal to the angle of friction of the soil, a parcel of it or same zero to depend on the case. The values found in literature also indicate as estimative for this angle values that vary of zero to the angle of friction of the soil. Experimental values for Brazilian soils are not available in literature. Of this form the projects of support walls can be being designed against the security or of uneconomical form. In this context in the present dissertation tests of direct shear in specimens of composites of soil and another representative material of support walls had been carried through (conventional concrete, concrete with recycled aggregate of RCD and rock), with the objective to get the friction angle soil-wall. Two soils of the hillsides of Recife had been used (sandy and a other clayey one). The roughness of the surfaces in contact with soil had been evaluated, to analyze its influence in the interaction soil-wall. The gotten results are compared with values suggested in literature, having considered the influence of the soil and the roughness of the contact surface. The relation enters the friction angle soil-wall and the angle of friction of the ground (ä/ö) varies of 3/4 the 1, with the average roughness for the soil sandy of the Ibura and of 1/3 the 3/4 for the soil clayey of Nova Descoberta. In the soil sandy, the friction soil-wall has minor influence of the roughness of the faying surface and has value very next to the angle of internal friction of the soil. In the soil clayey the friction soil-wall strong is influenced by the roughness of the faying surface, and its value varies of 1/3 the 3/4 of the angle of friction of the soil / Um dos principais problemas, na Região Metropolitana do Recife (RMR), nas encostas, é a ocupação antrópica desordenada, aumentando o número de moradias em áreas de risco. Uma das soluções para a estabilização das encostas é o uso da construção de estrutura de contenção como muro de arrimo. O ângulo de atrito solo-muro é um parâmetro fundamental para o dimensionamento. O seu valor é utilizado na avaliação dos empuxos ativo e passivo na análise de estabilidade do muro. A prática atual de projetos considera o valor do ângulo de atrito solo-muro como sendo igual ao ângulo de atrito do solo, uma parcela dele ou mesmo nulo a depender do caso. Valores experimentais para solos brasileiros não estão disponíveis na literatura. Desta forma, os projetos de muros de arrimo podem estar sendo dimensionados contra a segurança ou de forma antieconômica. Neste contexto na presente dissertação, foram realizados ensaios de cisalhamento direto em corpos de prova de solo e de outro material representativo de muros de arrimo (concreto convencional, concreto com agregado de resíduos de construção e demolição - RCD e rocha), com o objetivo de obter os ângulos de atrito interno do solo e do contato solomuro. Foram utilizados dois solos das encostas do Recife um arenoso (Ibura) e outro argiloso (Nova Descoberta). Foram avaliadas as rugosidades das superfícies em contato com os solos, para analisar sua influência na interação solo-muro. Os resultados obtidos são comparados com valores sugeridos na literatura, considerando a influência do solo e da rugosidade da superfície de contato. A relação entre o ângulo de atrito solo-muro e o ângulo de atrito do solo (ä/ö) varia de 3/4 a 1, com a Rugosidade Média, para o solo arenoso do Ibura e de 1/3 a 3/4 para o solo argiloso de Nova Descoberta. No solo arenoso, o atrito solo-muro tem menor influência da rugosidade da superfície de contato e tem valor muito próximo do ângulo de atrito interno do solo. No solo argiloso o atrito solo-muro é fortemente influenciado pela rugosidade da superfície de contato, e o seu valor varia de 1/3 a 3/4 do ângulo de atrito do solo
10

Estudo da aderência de arames da armadura de tração em conectores de dutos flexíveis / Study of adhesion of tensile armor wiles in connectors for flexible pipelines

Marcelo Badini Daflon 08 September 2010 (has links)
Este projeto tem o objetivo de apresentar o estudo dos arames da armadura de tração que são empregados no transporte de óleo, gás e umbilicais hidráulicos na indústria petrolífera. Este estudo foi desenvolvido sob a necessidade de melhor ancoragem dos arames da armadura de tração de modo a garantir que, mesmo após a ruptura do arame dentro do conector não haverá o escorregamento do mesmo provocando a queda do duto flexível. Assim sendo, foi estabelecido o estudo de aderência da interface dos arames da armadura de tração dos dutos flexíveis. Com os ensaios concluídos se estudou um novo procedimento para o melhoramento de aderência mecânica dos arames com a resina epóxi. Após os ensaios de aderência e adesão concluídos foi realizado ensaio de tração em cada arame da armadura de tração sob sua montagem no conector de extremidade para verificação de carregamento que chegam nos ganchos dos arames da armadura de tração. Os estudos realizados no conector de extremidade de 2,5 demonstram que os ganchos dos arames da armadura de tração são de grande importância para a integridade estrutural do duto flexível, visto que o cone de resina formado dentro do conector não está em contato com toda a área dos arames das armaduras de tração. / This project aims to present the study of tensile armor wires usually employed in the transport of oil, gas and hydraulic umbilicals in the petroleum industry. This study was developed as a need for better anchoring of the tensile armor wires in order to guarantee that even after the rupture of the wire within the connector it will not slip causing the fall of the flexible riser. Thus was established the adhesion study of the interface of the tensile armor wires of the flexible risers. After the end of the tests a new procedure for improving mechanical adhesion between the wires and the epoxy resin was studied. After the end of the adhesion tests tensile test was performed on each wire of the tensile armor under its mounting on the end fitting for checking the loading that reaches the hook of the armor wires. The trials performed in the 2.5end fitting show that the tensile armor wire hooks are of great importance for the structural integrity of the flexible riser, as there is no contact between the resin cone formed within the end fitting and the tensile armor wires area.

Page generated in 0.0986 seconds