• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

ComparaÃÃo da insuflaÃÃo sustentada do balÃo intra-retal com insuflaÃÃo e desinsuflaÃÃo rÃpidas em indivÃduo assintomÃticos / Effects of two rapid inflation/deflation manometry techniques upon parameters of anorectal inhibition reflex

Fernando Jose do Rego Monteiro 18 August 2006 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / As maiores limitaÃÃes da manometria anorretal à a carÃncia de definiÃÃes uniformes de alguns parÃmetros e a padronizaÃÃo de tÃcnicas. Diferentes tÃcnicas tÃm sido utilizadas para induÃÃo do RIRA, justificando resultados discrepantes entre os diversos centros de pesquisa. O objetivo desse estudo foi identificar alteraÃÃes nos parÃmetros do RIRA quando comparado a insuflaÃÃo rÃpida (30ml/s), sustentada por 60 segundos do balÃo intra-retal com volumes de 30 e 60 ml de ar seguida de desinsuflaÃÃo rÃpida com a insuflaÃÃo e desinsuflaÃÃo rÃpidas nas mesmas condiÃÃes. Foram utilizados 40 indivÃduos voluntÃrios saudÃveis para estudo do RIRA, distribuÃdos igualmente entre os sexos, na faixa etÃria de 20 a 40 anos. Foi utilizado um sistema de perfusÃo pneumohidrÃulico com 4 canais e cateter radial. Os parÃmetros foram avaliados cerca de 2 cm da margem anal, utilizando a tÃcnica de traÃÃo estacionÃria. Foram avaliados: O comprimento do canal anal funcional, a zona de alta pressÃo (ZAP) com localizaÃÃo do ponto de maior pressÃo em relaÃÃo à margem anal, a sensibilidade retal mÃnima e a da urgÃncia inicial evacuatÃria, a pressÃo basal anal mÃdia, a pressÃo de contraÃÃo voluntÃria mÃxima, a resposta ao esforÃo evacuatÃrio e parÃmetros relacionados ao RIRA. Os resultados constataram elevaÃÃo significante no comprimento do canal anal funcional no sexo masculino, porÃm uma zona de alta pressÃo sem diferenÃa significante entre os sexos. A maior pressÃo ocorreu em mÃdia 1,7cm (1-2 cm) da margem anal. A sensibilidade retal mÃnima, a sensibilidade de urgÃncia inicial evacuatÃria, a pressÃo basal anal mÃdia prÃ-reflexos nÃo apresentaram diferenÃas significantes entre os sexos. A pressÃo de contraÃÃo voluntÃria mÃxima obteve elevaÃÃo significante no sexo masculino. A resposta normal de relaxamento do EAE ao esforÃo evacuatÃrio ocorreu em 90,9% e o padrÃo de defecaÃÃo dissinÃrgica ocorreu em 9,09%. A insuflaÃÃo rÃpida sustentada por 60 segundos elevou com significÃncia estatÃstica o tempo de relaxamento mÃximo do EAI, o tempo de recuperaÃÃo do tÃnus do EAI e a duraÃÃo do reflexo, mas nÃo alterou a amplitude de mÃximo relaxamento do EAI, quando comparado com a insuflaÃÃo e desinsuflaÃÃo rÃpidas. Os resultados demonstram que o padrÃo de insuflaÃÃo altera parÃmetros do RIRA, e que nÃo à possÃvel a comparaÃÃo de diferentes centros de pesquisa sem a padronizaÃÃo da tÃcnica. / Anorectal manometry is limited mainly by the lack of standardized parameters and techniques. A number of different techniques have been used to induce the anorectal inhibition reflex (AIR), but results have been inconsistent. The objective of the present study was to identify differences in AIR parameters between two different manometry techniques: a) rapid inflation (30ml/s) of intrarectal balloon with 30 and 60 ml air, maintained during 60 seconds and followed by rapid deflation, and b) fast inflation and deflation under similar circumstances. The study included 40 healthy volunteers aged 20-40 years and used a 4-channel pneumohydraulic perfusion system and radial catheter. The parameters, which were measured at approximately 2 cm from the anal margin by the stationary pull-through method, included: length of functional anal canal, high-pressure zone (HPZ) and highest pressure point in relation to anal margin, minimum rectal sensitivity, initial voiding urgency sensitivity, average basal anal pressure, maximum voluntary contraction pressure, response to voiding contraction and AIR-related parameters. The length of the functional anal canal was found to be significantly increased in males, but no significant difference in HPZ was observed between the sexes. On the average, the highest pressure was located 1.7cm (1-2 cm) from the anal margin. No significant difference was found between the sexes with regard to pre-reflex minimum rectal sensitivity, initial voiding urgency sensitivity and average basal anal pressure. The maximum voluntary contraction pressure was significantly increased in males. A normal response of internal anal sphincter (IAS) relaxation to voiding contraction was observed in 90.9% of the subjects while unsynergistic voiding patterns were found in 9.09%. Rapid inflation maintained for 60 seconds significantly increased the maximum IAS relaxation time, the recovery time of the IAS tone and the duration of the reflex, but did not affect the amplitude of the maximum IAS relaxation compared to rapid inflation and deflation. Our findings indicate that AIR parameters depend on inflation technique and that results from different centers will only be comparable after techniques have been stadardized.

Page generated in 0.0671 seconds