• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de estruturas porosas de polietileno de ultra alto peso molecular (PEUAPM) recobertas com apatitas para substituição e regeneração óssea /

Thomazini, Anahi Herrera Aparecida. January 2009 (has links)
Orientador: Antonio Carlos Guastaldi / Banca: José Augusto Marcondes Agnelli / Banca: José Carlos Bressiani / Banca: Cecília Amélia de Carvalho Zavaglia / Banca: Eliana Cristina da Silva Rigo / Resumo: Neste trabalho, estruturas porosas de Polietileno de Ultra Alto Peso Molecular (PEUAPM) recobertas com diferentes fases de apatita de importância biológica foram desenvolvidas com o objetivo de se obter um biomaterial adequado para a substituição e regeneração óssea, com a combinação das propriedades mecânicas do polímero, da bioatividade das biocerâmicas de apatita e do comportamento favorável dos materiais porosos. Devido às dificuldades de obtenção de recobrimentos de apatita sobre o PEUAPM relatadas na literatura, realizou-se inicialmente um Estudo Preliminar para avaliar a utilização de solução de peróxido de hidrogênio (H2O2) 30% para a modificação química da superfície do polímero, analisando a influência dos períodos de modificação de 24 e 48 horas na variação das propriedades mecânicas do PEUAPM e na obtenção das diferentes fases de apatita de importância biológica empregando-se o método biomimético. Os resultados obtidos, analisados por Microscopia Eletrônica de Varredura - MEV, Microanálise Semi-quantitativa por Energia Dispersiva de Raios X - EDX, Difratometria de Raios X - DRX, Espectroscopia no Infravermelho com Transformada de Fourier - FTIR, medidas de ângulo de contato e ensaio mecânico de resistência à tração, indicaram que a utilização de solução de H2O2 30% pelo período de 48 horas mostrou-se adequada como método de modificação da superfície do PEUAPM, pois possibilitou a formação de grupos funcionais hidrofílicos na superfície do polímero e resultou em menores alterações das propriedades mecânicas e elásticas do polímero. Constatou-se também que o emprego do método biomimético para o recobrimento da superfície do PEUAPM somente foi adequado com a utilização de soluções SBF com composições modificadas. Para o desenvolvimento das estruturas porosas de PEUAPM recobertas com ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work, porous samples of Ultra High Molecular Weight Polyethylene (UHMWPE) coated with different apatite phases of biological importance were developed, aiming to obtain a suitable biomaterial for bone replacement and regeneration, balancing the mechanical properties of the polymer, the bioactivity of apatite bioceramics and the favorable behavior of the porous materials. Due to the difficulties in obtaining apatite coatings on UHMWPE in the literature, a Preliminary Study was conducted to evaluate the use of a 30% solution of hydrogen peroxide (H2O2) for the chemical modification of the polymer surface, analyzing the influence of the modification periods of 24 and 48 hours on the variation of the mechanical properties of UHMWPE and in obtaining the different apatite phases of biological importance using the biomimetic method. The results obtained, analyzed by Scanning Electron Microscopy - SEM, Semi-quantitative microanalysis by Energy Dispersive X-ray - EDX, X-Ray Diffractometry - XRD, Fourier Transform Infrared Spectroscopy - FTIR, contact angle measurements and tensile strength mechanical tests, indicated that the use of a 30% solution of H2O2 for a period of 48 hours proved adequate as a surface modification method of UHMWPE, since it allowed the formation of hydrophilic functional groups on the surface of the polymer, resulting in lower changes of the mechanical and elastic properties of the polymer. It was also found that the use of the biomimetic method for the surface coating of UHMWPE was only appropriate with the use of SBF solutions with modified compositions. For the development of porous samples of UHMWPE coated with apatites, UHMWPE porous supports were obtained using NaCl as a pore-forming agent in proportions of 50, 60 and 70% (m/m) with particle size in the range of 175-350µm, 350-500µm and 175- 500µm. The apatite coatings were ... (Complete abstract click electronic access below) / Doutor
2

Termocronologia e história denudacional da Serra do Mar e implicações no controle deposicional da Bacia de Santos /

Ribeiro, Marli Carina Siqueira. January 2007 (has links)
Orientador: Peter Christian Hackspacher / Banca: Norberto Morales / Banca: Sandro Guedes / Banca: Cláudio Riccomini / Banca: Pedro José Nunes / Resumo: Neste trabalho são apresentados os resultados obtidos por meio de análises geomorfológicas (Mapa de Níveis de Paleosuperfícies) e termocronológicos (traços de fissão em apatitas e U-Th/He em apatitas) ao longo da Serra do Mar nos setores (1), (2), (3) e (4). As correlações entre as analises geomorfológicas e termocronológicas evidenciaram uma geológica e geomorfológica compreendida entre o Cretáceo Superior e Paleoceno, demonstrando que a evolução das morfologias que compõem a área de estudo estiveram associadas a eventos tectônicos e sucedidos por uma intensa atividade erosiva. De acordo com as datações realizadas utilizando termocronômetros com temperatura de fechamento distintas, estes indicaram que as configurações dos relevos que compõem a Serra do Mar não podem ser associadas apenas aos efeitos das atividades erosivas (recuo de escarpa) e isostáticas, para poderem explicar a homogeneidade entre as idades de traços de fissão e (U-Th)/He em apatitas, sem a presença da atuação tectônica soerguendo e desnivelando parte destes relevos. / Abstract: In this paper the results obtained geomorphological analysis (Map of levels of Palaeosurfaces) and thermochronogical analysis (apatite fission-track and UTh/ He). The correlation between the geomorphologica and the thermochronological analysis evidenced a geological and geomorphological evolution from the Upper Cretaceous to the Palaeocene, showing that the evolution of the morpholoies composing the study area were associated to tectonics events and preceded by intense erosive activity. According to the datings done using thermocronometers with distinct closing temperatures the configuration of the relieves that compose the Serra do Mar can not be associated only to the effects of the erosive (escarpment retreate) and isostatic activities but also to the tectonic motion uplifting and unlevelling part such morphologies, in order to explain the homogeneity between the ages of the fission-track and U-Th/He of apatites. / Doutor

Page generated in 0.0693 seconds