• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

L'influence de l'immersion complète dans l'eau sur la variabilité du rythme cardiaque

Duceppe, Virginie January 2006 (has links) (PDF)
L'impesanteur est un environnement qui induit un stress physiologique aux systèmes circulatoire et respiratoire. En dehors des missions spatiales, les effets physiologiques de l'impesanteur doivent être étudiés par l'entremise de modèles simulant cet environnement. Parmi ces modèles, on compte les vols paraboliques, la position inclinée de -7 degrés tête vers le bas par rapport à l'horizontale et l'immersion dans l'eau jusqu'au cou. Par contre, bien que ces modèles aient été validés, certains d'entre eux présentent des limites importantes. Par exemple, les vols paraboliques sont d'une durée d'environ 25-35 secondes ce qui permet seulement d'étudier les effets de très courte durée de l'impesanteur. L'immersion dans l'eau jusqu'au cou ne tient pas compte du gradient hydrostatique du cou à la tête. La présente étude a pour objectif de comparer la position inclinée de -7 degrés tête vers le bas par rapport à l'horizontale à l'immersion complète dans l'eau. Les variables considérées sont: le volume courant (VC), le débit ventilatoire (VE), l'intervalle RR moyen, le pNN50, le SDNN, les basses fréquences (BF) et hautes fréquences (HF) et l'équilibre sympathovagal (BF/HF). L'hypothèse expérimentale était que la variabilité du rythme cardiaque soit atténuée lors de l'immersion complète dans l'eau par rapport à celle enregistrée en position inclinée -7 degrés par rapport à l'horizontale tête vers le bas. Les résultats de la présente étude démontrent qu'il n'y a pas de différences significatives entre l'immersion complète dans l'eau et la position inclinée de -7 degrés tête vers le bas par rapport à l'horizontale à p < 0,10 lorsque l'on considère les variables énoncées ci-dessus. Ces résultats ont mené au rejet par analyse statistique de l'hypothèse expérimentale ce qui permet de conclure que l'immersion complète dans l'eau induit un stress physiologique équivalent à celui de la position inclinée de -7 degrés tête vers le bas par rapport à l'horizontale. ______________________________________________________________________________ MOTS-CLÉS DE L’AUTEUR : Immersion dans l'eau, Position inclinée, Variabilité du rythme cardiaque, Arythmie sinusale respiratoire, Impesanteur.
2

Mesures atraumatiques de débit sanguin : applications à la circulation cérébrale de l'Homme dans l'espace.

Braak, Laurent, January 1900 (has links)
Th. doct.-ing.--Autom.--Toulouse--I.N.P., 1980. N°: 120.
3

Contribution à l'analyse des signaux cérébraux liés à la navigation virtuelle en microgravité

Leroy, Axelle January 2006 (has links)
Doctorat en Sciences de la motricité / info:eu-repo/semantics/nonPublished
4

Instabilités d'interfaces fluides en apesanteur spatiale lors d'un changement brutal ou périodique d'accélération / Instabilities of fluid interfaces in microgravity under sudden or periodic change of acceleration

Gandikota Vs, Gurunath 16 December 2013 (has links)
L'étude du comportement d'un fluide proche de son point critique et soumis à des vibrations ou une variation rapide de gravité/acceleration est un sujet extrêmement intéressant. Les phénomènes physiques impliqués sont d'un grand intérêt non seulement pour la physique fondamentale mais aussi pour l'industrie spatiale. Dans cette thèse, trois problèmes sont principalement trait&s: (i) Etude de l'interaction de vibrations harmoniques avec une couche limite thermique dans un fluide supercritique en absence de gravité, (ii) Etude de l'interaction de vibrations avec une interface liquide/vapeur d'un fluide sous−critique sous plusieurs niveaux de gravité (les instabilités de Faraday et d'onde gelée, l'équilibre dynamique d'une interface) et (iii) Etude du phénomène de geyser à l'intérieur d'un réservoir partiellement rempli d'oxygène lorsqu'il est soumis à une variation rapide de la gravité (ou accélération). La thèse comporte une partie expérimentale et une partie numérique. Des expériences ont été réalisées sur les installations HYLDE et OLGA du CEA Grenoble utilisant respectivement les fluides H2 et O2 dans la zone sous−critique. Des simulations numériques sont réalisées pour étudier la stabilité d'une couche limite thermique et la dynamique d'une interface fluide soumise à une variation rapide de la gravité en utilisant des codes numériques basées sur le méthode volumes finis utilisant les algorithmes SIMPLER et VOF−PLIC respectivement. Plusieurs résultats intéressants ont été obtenus. Différents phénomènes ont été étudiés et quantifiés, comme l'instabilité de Faraday et l'instabilité d'onde gelée dans le domaine sous−critique et l'instabilité parametrique et l'instabilité Rayleigh−vibrationnelle dans le domaine supercritique. Les expériences ont permis de bien comprendre les raisons de la transition de l'instabilité de Faraday vers une structuration en bandes verticales très près du point critique. Les expériences et les simulations numériques sur le phénomène de geyser ont aidé à développer des corrélations empiriques pour les vitesses de la bulle et du geyser en prenant en compte les effets des parois. / The behavior of a near-critical fluid subjected to vibration or a rapid variation of acceleration is an extremely interesting topic of research. The resulting physical phenomena are of great interest in view of the fundamental physics involved and have great relevance to the space industry. The thesis addresses mainly three problems: (i) study of the interaction of harmonic vibration with a thermal boundary layer of a supercritical fluid under the absence of gravity, (ii) study of the inter- action of vibration with the liquid−vapor interface of a near−critical fluid under various gravity levels (Faraday and frozen wave instabili- ties, dynamic equilibrium of the interface) (iii) study of the geysering phenomenon inside a reservoir partially filled with a liquid when it is subjected to a rapid variation of gravity. Experiments are conducted onboard the zero−g installations HYLDE and OLGA developed by CEA Grenoble using H2 and O2 as the work- ing fluids. Numerical simulations are carried out using finite volume codes based on SIMPLER (for the problem involving the supercriti- cal fluid) and VOF−PLIC (for the interface dynamics problem under rapid variation of gravity). New and interesting results have been obtained. Various phenom- ena like the Faraday instability and the frozen wave instability in the sub−critical region and the parametric instability and the Rayleigh−vibrational instability in the supercritical region have been quantified. The experiments have successfully explained the reason behind the transition of the Faraday instability into vertical band pattern very close to the critical point. Experiments and numerical simulation of the geysering phenomenon have helped to evolve empir- ical correlations for the bubble rise and geyser edge velocities taking into account the effect of walls on these velocities.
5

A study of the efficacy of therapeutic electrical stimulation in minimizing disuse muscle atrophy and dysfunction of the quadriceps femoris muscle following knee surgery : a model for microgravity-induced disuse atrophy

Olha, Carolynn 08 1900 (has links)
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal. / Avec l'émergence des voyages spatiaux, plusieurs adaptations physiologiques ont été recensées en état d'apesanteur. L'apesanteur dans l'espace décroît l'activité et le chargement mécanique des muscles les plus importants pour déplacer et supporter le poids du corps, dans le but de maintenir une posture droite. Ces muscles, principalement les groupes musculaires des membres inférieurs, sont appelés muscles supporteurs du poids ; en réponse à une utilisation réduite, ils s'affaissent et dépérissent, ou s'atrophient. Les changements incluent une réduction de la grosseur du muscle [59, 60], la décomposition des protéines musculaires [61], la réduction de la force [69, 70] et de l'endurance [60] musculaires, de même que des changements dans les types de fibres présentes dans les muscles [61]. La faiblesse et le mauvais fonctionnement musculaire survenant suite à une exposition aux vois spatiaux réfèrent communément à l'atrophie musculaire fonctionnelle induite par microgravité (l'atrophie musculaire fonctionnelle signifie une réduction du volume des muscles liée à l'inactivité). Aucun de ces changements ne présente un problème pour les astronautes tant et aussi longtemps qu'ils n'effectuent que de légers travaux. Pour les astronautes, le problème devient critique lorsqu'ils reviennent sur terre et que les muscles affaiblis sont de nouveau soumis à la force de gravité intégrale. Dans une situation d'urgence, les individus aux muscles affaiblis seraient moins aptes à répondre rapidement ou à utiliser la force musculaire. À présent, l'atrophie musculaire fonctionnelle des muscles des membres inférieurs induite par microgravité demeure un sérieux problème pour les astronautes qui poursuivent un vol spatial prolongé. Des contremesures comme l'exercice physique [91] peuvent aider au maintien de la -force et des fonctions musculaires, toutefois l'exercice seul est insuffisant pour prévenir l'excès en perte musculaire. Ainsi, il est nécessaire de développer des solutions plus efficaces. La présente recherche a été entreprise afin d'évaluer l'efficacité de la stimulation électrique thérapeutique (SET) pour minimiser l'atrophie musculaire fonctionnelle et le mauvais fonctionnement musculaire chez des patients ayant subi une reconstruction du ligament croisé antérieur (LCA). Le LCA est fréquemment lésé au cours de pratiques sportives. Une atrophie et un affaiblissement significatifs du groupe musculaire du quadriceps femoris (GMQF) survient suite à la reconstruction du LCA [131] et s'applique aux adaptations neuromusculaires survenant chez les astronautes suite à une exposition prolongée en état d'apesanteur. L'objectif de cette recherche était d'entreprendre des expériences préliminaires afin de déterminer le paradigme de stimulation le plus efficace pour minimiser l'atrophie musculaire fonctionnelle des membres inférieurs induite par microgravité chez les astronautes. Le recours à des patients ayant subi une reconstruction du LCA fournit un modèle adéquat servant à étudier les traitements pouvant minimiser de tels déficits des fonctions musculaires. Au total, 24 patients ont été assignés au hasard dans deux groupes, soit un groupe expérimental (n=12) ou un groupe contrôle (n=12), suite à la reconstruction du LCA grâce à une greffe du tendon patellaire. Durant les 12 semaines suivant l'opération, tous les patients ont suivi un programme standard de réhabilitation. De plus, le groupe expérimental a reçu un traitement par SET pendant six à huit heures, et ce, cinq soirs par semaine. Le torque maximal isocinétique du GMQF, le travail et la puissance moyenne ont été mesurés dans les deux membres inférieurs à 60°/sec et à 180°/sec, en plus de l'activation neurale (iEMG) et de la fréquence de la puissance -médiane (MED) des muscles vastus medialis et vastus lateralis, avant l'opération et à six et 12 semaines après l'opération. Toutes les mesures ont été standardisées en pourcentage du GMQF sain. Les résultats indiquent qu'après l'opération, le torque maximal isocinétique, le travail et la puissance moyenne étaient significativement réduits (p<0,01) dans le GMQF lésé, et ce pour les deux vitesses, à six et à 12 semaines, comparativement aux valeurs préopératoires. L'activité iEMG du muscle vastus lateralis était significativement réduite à six (p<0,01) et à 12 semaines (p<0,05) suite à l'opération. Toutefois, aucune réduction significative de l'activité iEMG du vastus medialis n'a été observée, et ce pour les deux vitesses, à six et à 12 semâmes après l'opération. Le MED est passé à des fréquences plus basses dans les muscles vastus lateralis (p<0,01) et vastus medialis (p<0,05) lorsque mesurée à six semaines. Cependant, 12 semaines après l'opération, le MED du vastus lateralis était revenu aux valeurs préopératoires, alors que le changement de MED du vastus medialis persistait (p<0,05). Aucune différence significative n'a été observée entre les groupes contrôle et expérimental en terme de mesures du torque maximal isocinétique et d'activation des muscles vastus lateralis et vastus medialis tout au long de l'étude. En conclusion, la SET combinée à la réhabilitation n'a pas fourni de bénéfice supplémentaire en terme d'amélioration de la récupération du GMQF au début de la phase postopératoire chez des patients ayant subi une reconstruction du LCA grâce à une greffe du tendon patellaire.

Page generated in 0.0317 seconds