• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Eficiência energética em edificações: aplicação do RTQ-C – requisitos técnicos da qualidade para o nível de eficiência energética de edifícios comerciais, de serviços e públicos - na cidade de Uberlândia-MG

Tavares, Laura Resende 28 March 2012 (has links)
Dissertação (mestrado)—Universidade Brasília, Faculdade de Arquitetura e Urbanismo, 2012. / Submitted by Gabriela Botelho (gabrielabotelho@bce.unb.br) on 2012-07-16T12:30:50Z No. of bitstreams: 1 2012_LauraResendeTavares.pdf: 13326176 bytes, checksum: fba58ad5516711bbadf17629f5b5d45f (MD5) / Rejected by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com), reason: Documento não está bloqueado on 2012-07-16T13:53:35Z (GMT) / Submitted by Gabriela Botelho (gabrielabotelho@bce.unb.br) on 2012-07-16T14:29:43Z No. of bitstreams: 1 2012_LauraResendeTavares.pdf: 13273067 bytes, checksum: 1b215fcd6ace29a6c44c5dafabdfff0e (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2012-07-17T13:39:19Z (GMT) No. of bitstreams: 1 2012_LauraResendeTavares.pdf: 13273067 bytes, checksum: 1b215fcd6ace29a6c44c5dafabdfff0e (MD5) / Made available in DSpace on 2012-07-17T13:39:19Z (GMT). No. of bitstreams: 1 2012_LauraResendeTavares.pdf: 13273067 bytes, checksum: 1b215fcd6ace29a6c44c5dafabdfff0e (MD5) / As edificações consomem 45% de toda energia gerada no Brasil, considerando os edifícios residenciais, comerciais, de serviços e públicos (MINISTÉRIO DE MINAS E ENERGIA, 2009). No entanto, há um expressivo potencial de conservação neste setor, avaliado em 30% para edificações existentes, através de retrofit (reforma) podendo chegar a 50% nas novas edificações (ELETROBRÁS-PROCEL, 2010). No Brasil, em 2001, após uma crise energética local, iniciaram-se os estudos que deram origem ao primeiro regulamento brasileiro de eficiência energética de edificações. Neste contexto, o objetivo principal deste trabalho é avaliar a aplicabilidade da metodologia brasileira de avaliação da eficiência energética de edifícios comerciais, de serviços e públicos, RTQ-C (INMETRO, 2010), para as condições em que a simulação é indicada e não há arquivo climático horário de simulação disponível para cidade. A avaliação será realizada através de um estudo de caso no Campus Santa Mônica da UFU - Universidade Federal de Uberlândia-MG. O edifício escolhido reflete a preocupação dos novos projetos da UFU, no que se refere às questões de conforto ambiental e eficiência energética, e seu projeto está sendo repetido no mesmo campus e no Campus de Ituiutaba. Os procedimentos metodológicos aplicados foram: seleção, análise e tratamento dos dados climáticos da cidade de Uberlândia para identificação do ano climático de referência (TRY); formatação de um arquivo climático horário para simulação termoenergética e a elaboração da carta bioclimática de Uberlândia; aplicação dos métodos prescritivo e simulação do RTQ-C no edifício estudo de caso e comparação dos resultados obtidos em cada um destes métodos. Os resultados obtidos foram: a identificação do ano de 2006 como ano TRY; o arquivo climático horário em extensão *epw e um arquivo com dados estatísticos em extensão *stat, que classificou o clima da cidade de acordo com a classificação de Köppen como “Aw”, tropical de savana; a carta bioclimática de Uberlândia, indicando 63,2% das horas na zona de conforto, sendo 36,8% em desconforto, 18,6% por frio e 18,1% por calor; obtenção da etiqueta A para o edifício estudo de caso, pelos métodos prescritivo e simulação. Algumas divergências foram encontradas na comparação entre os métodos, relacionadas diretamente à simulação da ventilação natural para obtenção do POC (percentual de horas ocupadas em conforto), uma vez que as áreas não condicionadas, bem maiores que as áreas condicionadas, a simulação separada para cada ambiente não-condicionado e a exclusão dos cobogós pode ter prejudicado os resultados. Conclui-se que uma base de dados horários organizada para aplicação em simulações termoenergéticas de edifícios, uma metodologia precisa para obtenção do arquivo climático e investigações quanto ao desempenho dos programas de simulação quando se simula edifícios com ambientes condicionados e nãocondicionados, permitiria um maior avanço nas pesquisas relacionadas à eficiência energética das edificações e cidades, permitindo que regulamentações como o RTQ-C sejam aplicadas em um número cada vez maior de cidades. _________________________________________________________________________ ABSTRACT / Buildings consume 45% of all energy generated in Brazil, considering the residential, commercial, services and public buildings (Ministry of Mines and Energy, 2009). However, there is a significant potential for conservation in this sector, estimated at 30% for existing buildings through retrofit (renovation) that could reach 50% in new buildings (ELETROBRÁS-PROCEL, 2010). In 2001 in Brazil, after a local energy crisis, the first regulations for energy efficiency of buildings where created based on several researches. In this context, the aim of research is to evaluate the applicability of a Brazilian methodology for evaluating energy efficiency of commerce, services and public buildings, that so called RTQ-C (INMETRO 2010). In this research, this methodology was used in conditions that the simulation was indicated and when the city didn’t have previous weather file available. The valuation will be apply through a case study on the campus of Santa Monica UFU - Federal University of Uberlândia- MG. The chosen building reflects the concern of UFU’s new projects, with regards to environmental comfort and energy efficiency issues, and its design is repeated on the same campus and the Campus of Ituiutaba. The methodological procedures used were: selection, analysis and processing of weather data from the city of Uberlândia to identify the Test reference year (TRY), formatting of a weather file simulation and the development of bioclimatic chart of Uberlândia; application of two methods of RTQ-C - prescriptive and simulation - the building case study and comparison of results obtained in each of these methods. The results were: the identification of 2006 as -TRY year, the time weather file in *epw extension and a file with statistical data in * stat extension, which classified the city's climate according to Köppen's classification as "Aw”, tropical savanna; the bioclimatic chart of Uberlândia indicating 63.2% of the hours in the comfort zone, and 36.8% in discomfort, 18.6% by cold and 18.1% by hot, obtaining the label A for the case study building, by the prescriptive and simulation methods. Some differences were found when comparing the methods, directly related to the simulation of natural ventilation to obtain POC (percentage of occupied hours in comfort), since the non-conditioned areas, much larger than the conditioned areas, a separate simulation for each non-conditioned environment and the exclusion of the cobogós may have impaired the results. It is concluded that an organized time database for use in thermal energy simulations of buildings, a precise methodology for obtaining weather file and investigations on the performance of simulation programs when simulating buildings with conditioned and non-conditioned environments, would allow a major advance in research related to energy efficiency of buildings and cities, enabling regulations like the RTQ-C to be applied in an increasing number of cities.
2

Eficiência energética e conforto ambiental na escolha de edificações para agências do Banco do Brasil : proposta de critérios para o Distrito Federal

Pedreira, João Carlos Simão 30 August 2010 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2010. / Submitted by Allan Wanick Motta (allan_wanick@hotmail.com) on 2011-01-19T18:12:58Z No. of bitstreams: 1 2010_JoaoCarlosSimaoPedreira.pdf: 8934820 bytes, checksum: 01ebdb59454cc54151d5417a09c359bc (MD5) / Approved for entry into archive by Gomes Neide(nagomes2005@gmail.com) on 2011-01-20T17:41:32Z (GMT) No. of bitstreams: 1 2010_JoaoCarlosSimaoPedreira.pdf: 8934820 bytes, checksum: 01ebdb59454cc54151d5417a09c359bc (MD5) / Made available in DSpace on 2011-01-20T17:41:32Z (GMT). No. of bitstreams: 1 2010_JoaoCarlosSimaoPedreira.pdf: 8934820 bytes, checksum: 01ebdb59454cc54151d5417a09c359bc (MD5) Previous issue date: 2010 / As agências bancárias do Banco do Brasil, em todo o país, há muito tempo vêm sendo instaladas em edificações alugadas e adaptadas para essa atividade. O atual processo de escolha destas edificações ainda não possui critérios objetivos em relação aos conceitos de eficiência energética e conforto ambiental (térmico e luminoso). Este fato pode contribuir para uma escolha equivocada, considerando-se que a envoltória das edificações pode ser avaliada em diferentes níveis de eficiência, tendo suas características como a grande responsável pelo conforto ambiental dos usuários. Sendo assim, esse estudo tem como principal objetivo delimitar critérios para a escolha de edificações comerciais no Distrito Federal com características de conforto ambiental e eficiência energética visando à instalação das agências bancárias. Inicialmente, a Metodologia utilizada compreendeu a revisão bibliográfica sobre o tema (arquitetura de agência bancária; eficiência energética na arquitetura; conforto térmico e luminoso e metodologias de análise ambiental). Posteriormente, foi realizada uma pesquisa das principais características físicas da envoltória dessa tipologia mediante levantamento fotográfico e os projetos arquitetônicos de 40 edificações de agência bancária do Banco do Brasil no DF. Com os dados obtidos foi possível analisar a envoltória de 10 edificações utilizando-se as ferramentas: Diagrama Morfológico e método prescritivo do Regulamento Técnico da Qualidade do Nível de Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos – RTQ-C (INMETRO, 2009). Na terceira fase do estudo foram realizadas simulações computacionais com o Software Relux para análise dos níveis de iluminância de 6 edificações. O resultado do estudo é uma Planilha para Escolha de Edificações Energeticamente Eficientes (P4E) que visa auxiliar o corpo técnico (arquitetos e engenheiros) do Banco do Brasil na escolha de edificações comerciais no Distrito Federal. Essa planilha foi validada após sua aplicação em 10 edificações de agência bancária do DF e poderá ser utilizada para servir de base para futuras planilhas para as demais Zonas Bioclimáticas do Brasil, contribuindo assim, na escolha das edificações em todo país. _______________________________________________________________________________ ABSTRACT / Bank branches of Banco do Brasil throughout the country have long leased building spaces which have been adapted for banking activities. The current process of choosing such buildings lacks objective criteria regarding energy efficiency and environmental comfort (thermal and lighting). This may lead to mistaken choices as the building envelopes may be evaluated at different levels of efficiency and their characteristics are a major factor in the environmental comfort of the users. The aim of this study is to define criteria for the selection of commercial buildings with environmental comfort and energy efficiency features for the installation of bank branches in Distrito Federal. The methodology consists of a review of the literature on the subject (bank branch architecture; energy efficiency in architecture; thermal and lighting comfort; and environmental analysis methodologies), followed by a study of the main physical characteristics of this envelope typology through a photographic survey and the architectural plans of 40 buildings used for branches of Banco do Brasil in Distrito Federal. From the data obtained, it was possible to analyze the envelopes of ten buildings using the following tools: Morphological Chart and the prescriptive method of the Technical Regulation for the Quality of the Energy Efficiency Level of Commercial, Service and Public Buildings – RTQ-C (INMETRO, 2009). In the third phase of the study, computer simulations using Relux software for the analysis of the levels of lighting of six buildings were carried out. The result of the study is a Worksheet for Selecting Energy Efficient Buildings (P4E), which aims to assist the technical staff (architects and engineers) of Banco do Brasil in their choice of commercial buildings in Distrito Federal. This worksheet was validated after its application to ten bank branch buildings in Distrito Federal and can be used as a basis for further worksheets in the other bioclimatic zones of Brazil, therefore contributing to better building selection throughout the country.
3

Eficiência energética de edificações residenciais no Plano Piloto de Brasília : uma análise comparativa com utilização do RTQ-R

Meira, Ana Ceres Belmont Sabino January 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2014. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2014-12-30T11:06:49Z No. of bitstreams: 1 2014_AnaCeresBelmontSabinoMeira.pdf: 4991387 bytes, checksum: e09182c6db10bbf8d4aed8bf468d2e6c (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2014-12-30T12:06:09Z (GMT) No. of bitstreams: 1 2014_AnaCeresBelmontSabinoMeira.pdf: 4991387 bytes, checksum: e09182c6db10bbf8d4aed8bf468d2e6c (MD5) / Made available in DSpace on 2014-12-30T12:06:09Z (GMT). No. of bitstreams: 1 2014_AnaCeresBelmontSabinoMeira.pdf: 4991387 bytes, checksum: e09182c6db10bbf8d4aed8bf468d2e6c (MD5) / Eficiência energética é uma das estratégias para mitigar os problemas ambientais no mundo. Conservar energia significa diminuir o consumo e reduzir custos, sem perder a eficiência e a qualidade dos serviços. No Brasil após a crise energética de 2001 surgiu a necessidade de elaboração de projetos arquitetônicos energeticamente eficientes para o setor residencial, sem comprometer a qualidade de vida de seus usuários. Visando a redução no consumo energético das edificações foram desenvolvidas regulamentos de eficiência energética. A etiquetagem do nível de eficiência energética de edifícios residenciais foi criada através do Regulamento Técnico da Qualidade para Edifícios Residenciais (RTQ–R) que especifica os requisitos técnicos, bem como os métodos para a classificação de edifícios residenciais através da Etiqueta Nacional de Conservação de Energia (ENCE), de ―A‖ (mais eficiente) até ―E‖ (menos eficiente). O RTQ–R pode ser utilizado para avaliar diferentes tipos arquitetônicos, comparando sua eficiência energética no contexto das cidades contemporâneas, ou avaliando a evolução da arquitetura, para orientar a tomada de decisões quanto a novos projetos. Em Brasília, a expansão imobiliária forçou as transformações da arquitetura e o surgimento de novos bairros residenciais. Neste contexto, este trabalho tem como objetivo analisar comparativamente o nível de eficiência energética de edificações residenciais construídas em diferentes períodos, no Plano Piloto da cidade de Brasília. Os edifícios de Brasília podem ser divididos três grandes grupos: o Grupo 1 inclui os edifícios construídos de1960 até fins de 1970, o Grupo 2 de 1980 até 2004 e o Grupo 3 de 2004 até o presente, incluindo aquelas do novo bairro Noroeste, candidato a uma certificação de sustentabilidade. Os procedimentos metodológicos desta pesquisa incluíram o levantamento de edificações correspondentes aos três grupos, com base em características tipológicas e construtivas e a classificação do nível de eficiência energética da envoltória desses edifícios. O método utilizado para obtenção da classificação do nível de eficiência energética foi o prescritivo, apresentado pelo RTQ-R através da avaliação da envoltória. Os principais resultados desta pesquisa foram a avaliação comparativa dos edifícios a partir do diagnóstico do desempenho termoenergético da envoltória e a identificação das variáveis com influência mais significativa. Foi verificado que a edificação do Grupo 1 obteve nível de eficiência ―B‖ (EqNumEnv de 4,43 a 3,86 para todas UH), a do Grupo 2 obteve nível de eficiência ―A‖ (EqNumEnv = 4,68 para 20 UH e de 4,10 a 3,32 para 8 UH) e a do Grupo 3 nível de eficiência ―C‖ (EqNumEnv de 3,87 a 3,71 para 20 UH e de 3,00 a 2,86 para 16 UH). Os resultados apontam a edificação do Grupo 2 como as mais eficientes, e que o edifício do Grupo 3 (Bairro Noroeste) atingiu níveis de eficiência energética inferiores aos dos construídos nas décadas anteriores. Nota-se a influência da forma das edificações, da presença das proteções solares e da compartimentação interna das unidades habitacionais, assim como das aberturas (forma/posição e quantidade) para ventilação e iluminação natural. _________________________________________________________________________________ ABSTRACT / Energetic efficiency is one of the strategies to mitigate environmental problems in the world. Energy conservation means reducing both consumption and costs without losing efficiency and quality of services. In Brazil after the energetic crisis of 2001 the need for energetic efficient architectural designs for the residential sector has emerged, without compromising the quality of life of its residents. In order to reduce the energy consumption of buildings regulation on energy efficiency were developed. The labeling of the level of energy efficiency of residential buildings was created through the Technical Quality Regulations for Residential Buildings (RTQ-R) that specifies the technical requirements as well as the methods for the classification of residential buildings through the National Energy Conservation Label (ENCE) , from "A" (most efficient) to "E" (least efficient). The RTQ-R can be used for benchmarking different architectural types, either comparing their energetic efficiency in the context of contemporary cities, or evaluating the evolution of architecture, in order to making decisions on new projects. In Brasilia, the housing boom has forced the emergence of new neighborhoods and the transformation of architecture. In this context, this work aims the comparison of energetic efficiency level of residential buildings constructed at different periods, in the Master Plan of the city of Brasilia. The buildings of Brasilia can be classified into three groups: Group 1 includes buildings built in the 1960s up to the end of the 1970s, Group 2 those built from 1980 up to 2004 and Group 3 including those built from 2004 until the present date, in the new Noroeste neighborhood, candidates to sustainability certification. The methodological procedures of this research included a survey of representative buildings of the three groups, based on typological and constructive characteristics and classification of the level of the envelope energetic efficiency of these buildings. The method used to obtain the classification of the level of energetic efficiency was the prescriptive one set by RTQ -R through the evaluation of the envelope. The main results of this research were the benchmarking of buildings from the envelope thermoenergetic performance diagnosis and the identification of variables with energetic significant influences. It was verified that the representative building of Group 1 received level of efficiency "B" (EqNumEnv from 4.43 down to 3.86 for all housing units), the representative of Group 2 received level of efficiency "A" (EqNumEnv = 4.68 for 20 housing units and 4.10 down to 3.32 for 8 housing units) and the representative of Group 3 the level of efficiency "C" (EqNumEnv from 3.87 down to 3.71 for 20 housing units and from 3.00 down to 2.86 for 16 housing units). Results show building of Group 2 as the most efficient, and building of Group 3 (Norwest neighborhood) reached levels of energetic efficiency lower than those built in previous decades. It is remarkable the influence of the shape of the buildings, presence of sun protection systems and the internal divisions of the housing units as well as the openings (shape/position and amount) for natural ventilation and illumination.
4

Eficiência energética em um ministério da Esplanada em Brasília : propostas para retrofit de envoltória

Nicoletti, Ana Maria Abrahão 15 December 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2009. / Submitted by Shayane Marques Zica (marquacizh@uol.com.br) on 2011-02-21T18:17:05Z No. of bitstreams: 1 2009_AnaMariaAbrahaoNocoletti.pdf: 10424668 bytes, checksum: d44bb5c260562a5a67bcfaa57cb3cdf9 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2011-03-11T00:25:13Z (GMT) No. of bitstreams: 1 2009_AnaMariaAbrahaoNocoletti.pdf: 10424668 bytes, checksum: d44bb5c260562a5a67bcfaa57cb3cdf9 (MD5) / Made available in DSpace on 2011-03-11T00:25:13Z (GMT). No. of bitstreams: 1 2009_AnaMariaAbrahaoNocoletti.pdf: 10424668 bytes, checksum: d44bb5c260562a5a67bcfaa57cb3cdf9 (MD5) / Esta dissertação apresenta uma análise da viabilidade técnica e financeira da proposição de retrofit de envoltória, em tipologias representativas de edifícios públicos de escritórios, para otimizar o seu desempenho térmico e energético. O trabalho foi desenvolvido por meio da avaliação de componentes construtivos industrializados disponíveis no mercado nacional que se apresentaram potencialmente viáveis para aplicação no objeto de estudo, um dos edifícios dos Ministérios, em Brasília. Neste caso, as propostas mantem as características essenciais da envoltória, devido à necessidade de preservação do edifício pelo seu caráter representativo e também pelas restrições advindas com a necessidade de preservação de sua arquitetura. A metodologia utilizada é a proposta pelo Regulamento Técnico da Qualidade para Eficiência Energética de Edifícios Comerciais, de Serviços e Públicos -RTQ -C (INMETRO, 2009), a partir da classificação e etiquetagem da envoltória do edifício, objeto de estudo, comparando os resultados da metodologia prescritiva e da simulação, a fim de investigar o potencial de melhoria da eficiência energética, a partir dos critérios de classificação propostos pela regulamentação. Para subsidiar estas iniciativas com o estudo de viabilidade financeira foi utilizado o indicador RCB (Relação Custo-Benefício) para a avaliação comparativa de custos relacionados à eficiência da envoltória visando a delimitação da melhor solução em eficiência energética. O resultado deste trabalho apresenta uma comparação de alternativas para melhoria da eficiência energética da envoltória em tipologias de edifícios de escritórios existentes. A análise de sensibilidade dos parâmetros da equação do Índice de Consumo da envoltória (metodologia prescritiva/ RTQ-C) e da calibração do modelo (metodologia da simulação/ RTQ-C) apontam que variações no percentual de abertura das fachadas (PAFt) e no fator solar (FS) dos vidros provocam alterações consideráveis nos resultados, sendo que a redução destes valores repercute em melhores níveis de eficiência energética. Os resultados indicam como possibilidade para a reabilitação do edifício analisado o uso de painéis EPS TI acoplados internamente às fachadas, reduzindo o PAFt, o uso de película de controle solar, reduzindo o fator solar (FS) dos vidros e o isolamento térmico da cobertura. _________________________________________________________________________________ ABSTRACT / This dissertation presents an analysis of technical and financial feasibility of the proposition retrofit envelope in representative types of public buildings for offices, to optimize its performance and thermal energy. The study was conducted through the evaluation of industrialized building components available on the domestic market that had potentially useful for application in the object of study, one of the buildings of the Ministries, in Brasilia. In this case, the proposals keep the essential characteristics of the envelope because of the need to preserve the building by its representative character, and also by restrictions arising with the need for preservation of its architecture. The methodology used is that proposed by the Technical Regulation for Energy Efficiency for Commercial Buildings, and Public Service-RTQ-C (INMETRO, 2009), based on the classification and labeling of the envelope of the building, object of study, comparing the results of the prescriptive methodology and simulation to investigate the potential for improving energy efficiency, from the classification criteria proposed by the regulations. To complement these initiatives with the financial feasibility study was provided using the RCB (Cost-Benefit) for the comparative assessment of costs related to the efficiency of the envelope to delineate the ultimate in energy efficiency. The result of this work presents a comparison of alternatives for improving the efficiency of the envelope in types of existing office buildings. The sensitivity analysis of parameters of the Index of Consumer envelope (prescriptive methodology / RTQ-C) and calibration of the model (methodology of simulation / RTQ-C) indicate that variations in the percentage of openness of the facades (TFAP) and the solar factor (FS) of glasses cause significant changes in the results, and the reduction of these values reflected in improved levels of efficiency. The results indicate a possibility for rehabilitation of the building analyzed the use of EPS panels IT internally coupled to the facades, reducing the TFAP, the use of solar control film, reducing the solar factor (SF) of glass and thermal insulation of the roof.
5

Análise da demanda energética para climatização de fachadas ventiladas para regiões climáticas brasileiras

Maciel, Ana Carolina Fernandes 31 July 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2018. / Atualmente, o consumo energético é item de suma importância na avaliação de edificações, pois estima-se que, no setor de construção civil, ele seja de 45% nos EUA e 42% no Reino Unido, enquanto que a média de 31% é contabilizada nos países da Organização de Cooperação e Desenvolvimento Econômico (OECD) em comparação com o total de consumo de energia de toda a indústria. No Brasil o consumo energético por edificações representa 50% do consumo de eletricidade no país. Edificações que prezam pela eficiência energética necessitam de envoltórias pensadas para a localidade e região climática em que se situam, e é nesse panorama que esta pesquisa está inserida, um estudo acerca da Energia Operacional de Fachadas Ventiladas Opacas comparativamente à Fachadas com revestimento aderido para edificações habitacionais de múltiplos pavimentos, em nove regiões climáticas no Brasil (classificação Köeppen-Geiger). Neste estudo foi quantificada e analisada a Energia Operacional de Fachada Ventilada de Granito e a de Fachada de Revestimento Aderido de Granito para efeito de comparação. Com os resultados dos custos energéticos de cada uma e o levantamento de custo de implantação, foi realizada a análise do custo-benefício de implantação das fachadas ventiladas opacas nas 16 cidades analisadas. Também foram realizadas, nas nove regiões climáticas, três análises paramétricas para verificar o impacto de diferentes revestimentos (granito, porcelanato e cerâmica), diferentes espessuras de câmara de ar (5, 10 e 15cm) e diferentes aberturas para entrada e saída de ar (2, 4 e 6cm). Para obtenção dos dados, foram realizadas simulações no sistema de informação BIM e BES, com o auxílio de dois softwares de mesma empresa, Autodesk Revit 2018 e Green Building Studio. Os resultados encontrados corroboram os resultados de outros autores e conclui-se que a economia energética apresentada pelas fachadas ventiladas em relação às fachadas de revestimento aderido é de grande relevância, principalmente em climas mais quentes, uma vez que os maiores benefícios encontrados neste estudo foram nas regiões climáticas Af, Am, As, Aw e BSh. Para o Brasil é um sistema de impacto significativo, pois a maior parte do território nacional encontra-se nas zonas mais quentes, colaborando para menores impactos ambientais ao longo da vida útil das edificações que o utilizam e onde foi encontrado o melhor custo-benefício. As análises paramétricas mostraram diferenças nas análises em algumas cidades, demonstrando a influência do clima em diferentes quesitos analisados. / Currently, energy consumption is a very important parameter when evaluating building efficiency since it is estimated that of the total energy consumption of the industry sector, the construction sector accounts for 45% and 42% in the USA and United Kingdom, respectively, and for 31% on average in the countries of the Organization for Economic Cooperation and Development (OECD). In Brazil, the energy consumed in buildings accounts for 50% of the electricity consumption in the country. Energy efficient buildings need envelopes designed for the locality and climatic zone where they are located. This research addresses this question by comparing the operational energy consumption between opaque ventilated facade and cladding facades on residential buildings in nine different climatic zones in Brazil (Köeppen-Geiger classification). Therefore, the operational energy of a granite ventilated facade and adherent granite facade were quantified and analyzed for comparison purposes. After obtaining the energy costs and the cost of implantation of each one, the cost-benefit analysis of installing the ventilated facades was carried out in the 16 cities analyzed. In the nine climatic zones, three parametric analyses were performed to verify the impact of different coatings (granite, porcelain and ceramic), different air chamber thicknesses (5, 10 and 15 cm) and different air inlet and outlet openings (2, 4 and 6 cm). Simulations were performed in the BIM and BES information systems to obtain the data, using two software from the same company, Autodesk Revit 2018 and Green Building Studio. The obtained results corroborate previous results by other authors and allowed to conclude that ventilated facades provide a significant energy saving capability compared to adherent facades, especially in warmer climates, since the greatest benefits found in this study were in the Af, Am, As, Aw and BSh climatic zones. In Brazil, since most of the national territory is located in hot climate areas, this system can have a significant effect, contributing to lower environmental impact throughout the life cycle of the buildings using it and the best cost-benefit. Parametric analyzes showed differences in the analyses in some cities, demonstrating the climate influence on the different analyzed questions.
6

Código de obras e edificações do DF : inserção de conceitos bioclimáticos, conforto térmico e eficiência energética

Fernandes, Júlia Teixeira 14 December 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2009. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-04-04T21:07:40Z No. of bitstreams: 3 2009_JuliaTeixeiraFernandesTerceiraParte.pdf: 7146694 bytes, checksum: 59acde6d97b9a53da955dc00b0951eb2 (MD5) 2009_JuliaTeixeiraFernandesSegundaParte.pdf: 16605244 bytes, checksum: 40275bb969ba196111f7294c872cb107 (MD5) 2009_JuliaTeixeiraFernandesPrimeiraParte.pdf: 6015314 bytes, checksum: 53bd63fbcbd21aea9341aa5e3a2a9228 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-04-04T21:13:00Z (GMT) No. of bitstreams: 3 2009_JuliaTeixeiraFernandesTerceiraParte.pdf: 7146694 bytes, checksum: 59acde6d97b9a53da955dc00b0951eb2 (MD5) 2009_JuliaTeixeiraFernandesSegundaParte.pdf: 16605244 bytes, checksum: 40275bb969ba196111f7294c872cb107 (MD5) 2009_JuliaTeixeiraFernandesPrimeiraParte.pdf: 6015314 bytes, checksum: 53bd63fbcbd21aea9341aa5e3a2a9228 (MD5) / Made available in DSpace on 2011-04-04T21:13:00Z (GMT). No. of bitstreams: 3 2009_JuliaTeixeiraFernandesTerceiraParte.pdf: 7146694 bytes, checksum: 59acde6d97b9a53da955dc00b0951eb2 (MD5) 2009_JuliaTeixeiraFernandesSegundaParte.pdf: 16605244 bytes, checksum: 40275bb969ba196111f7294c872cb107 (MD5) 2009_JuliaTeixeiraFernandesPrimeiraParte.pdf: 6015314 bytes, checksum: 53bd63fbcbd21aea9341aa5e3a2a9228 (MD5) / Os Códigos de Obra e Edificações são responsáveis por garantir a qualidade mínima das edificações, mas os índices exigidos, em sua maioria, não são adequados aos condicionantes locais. Brasília, projetada por Lúcio Costa, é singular pelo conceito embutido em cada decisão do urbanista na configuração do espaço. A função do código de obra da cidade é preservar o caráter da cidade, a sua identidade como patrimônio, além de ordenar o crescimento de todo o DF. O objetivo geral da pesquisa era diagnosticar o COE-DF quanto aos conceitos bioclimáticos e termo-energéticos como contribuição para a melhoria da qualidade do ambiente construído, a partir de diretrizes para uma nova revisão, pautada na adaptação da legislação aos condicionantes locais. Foram identificadas pesquisas e legislações importantes que poderão ser subsídios para a inserção desses conceitos, assim como sistematizados os principais parâmetros que devem ser analisados na revisão do COE-DF. A análise dos artigos demonstrou que é possível já revisar o código para garantir um mínimo de desempenho bioclimático e termo-energético das edificações, mesmo que a princípio sejam inseridas diretrizes de projeto, pois para a análise de vários parâmetros é necessária a revisão conjunta de outras legislações urbanas e a criação de metodologia específica para avaliação do projeto. Os anexos relativos às diretrizes bioclimáticas e eficiência energética para edificações no DF são medidas positivas, como forma de auxiliar no projeto arquitetônico e incentivar a inserção destes conceitos na prática dos arquitetos. É necessário contribuir para transformar as leis em mecanismos eficientes no processo de construção das edificações. _________________________________________________________________________________ ABSTRACT / The building are a set of rules responsible for ensuring the minimum quality of building, but most of the required patterns are not suited to local conditions. Brasilia, designed by Lucio Costa, has a unique aspect for the embedded concept present in every decision of the urbanist in the space configuration. The purpose of the city’s building code is to preserve the character of the city and its identity as a heritage, as well as to plan the growth of all the Federal District. The Goal of this research is to diagnose the CWB-FD regarding bioclimatic concepts and thermal energy as a contribution to improving the quality of the builit environment considering guidelines for a new revision, based on the adaption of legislation to local conditions. Important researches and legislations were consulted, which may set forth relevant elements for the insertion of these conceptis, besides the systematization of the main parameters thar must be analyzed under the CWB-FD. The analyses of the articles pointed uot that it us already possible to revise the code to ensure a minimum of bioclimatic performance and thermally efficient buildings, even if project guidelines are initially included, as for the analysis of various parameters it is necessary a joint review of other urban laws and the cration of specific methodology for project evaluation. The annexes concerning the bioclimatic and energy efficiency guidelines for buildings in the Federal District are positive measires as an aid in architectural design, besides stimulating the integration of these concepts in architects’ practices. It is fundamental to turn laws into efficient mechanisms in the process of construction of buildings.

Page generated in 0.086 seconds