Spelling suggestions: "subject:"artificial hip joints"" "subject:"aartificial hip joints""
11 |
Perception of body image in elderly persons after total hip replacementGideon, Theresa Maduram January 1979 (has links)
No description available.
|
12 |
The effect of surface roughness and a collar on fixation of cemented femoral stems in vivo / by Scott Andrew Brumby.Brumby, Scott Andrew January 1996 (has links)
Bibliography: leaves 193-206. / xiii, 206 leaves : ill. (chiefly col.) ; 30 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / This thesis investigates the effect of femoral stem surface roughness and a collar on the fixation of cemented hip hemi-arthroplasty femoral stems in an in vivo sheep model up to nine months following implantation. Plain radiography, micromotion between prosthesis and bone during mechanical testing and histology are used. / Thesis (Ph.D.)--University of Adelaide, Dept. of Orthopaedics and Trauma, 1997?
|
13 |
A study of the effect of preoperative instruction by physical therapists on the recovery rate of total hip replacement patients /Quinn, Juanita Cusack. January 1981 (has links)
Thesis (Ed.D.)--University of Tulsa, 1981. / Bibliography: leaves 43-46.
|
14 |
A study of the effect of preoperative instruction by physical therapists on the recovery rate of total hip replacement patients /Quinn, Juanita Cusack. January 1981 (has links)
Thesis (Ed.D.)--University of Tulsa, 1981. / Bibliography: leaves 43-46.
|
15 |
A comparison of modeling techniques using the finite element method to determine local displacements in a human hip /Kinney, Timothy. January 2007 (has links)
Thesis (M.S.)--University of Missouri-Columbia, 2007. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file (viewed on April 14, 2008) Includes bibliographical references.
|
16 |
Numerical and experimental analysis of stress behavior of plasma-sprayed Bioglass on titanium /Park, Hyuen Me (Mia) Park, January 1996 (has links)
Thesis (M.S.)--Oregon Graduate Institute of Science and Technology, 1996.
|
17 |
Failure analysis and materials characterization of hip implantsBastidos, Amanda Marie, January 2009 (has links)
Thesis (M.S.)--University of Texas at El Paso, 2009. / Title from title screen. Vita. CD-ROM. Includes bibliographical references. Also available online.
|
18 |
The effect of particle surface area to volume ratio on ion release from CoCr spheres a thesis /Grandfield, Darin Joseph. Harding, Trevor S. January 1900 (has links)
Thesis (M.S.)--California Polytechnic State University, 2009. / Title from PDF title page; viewed on September 22, 2009. Major professor: Trevor Harding, Ph.D. "Presented to the faculty of California Polytechnic State University, San Luis Obispo." "In partial fulfillment of the requirements for the degree [of] Master of Science in Engineering, with Specialization in Materials Engineering." "June 2009." Includes bibliographical references (p. 80-84). Also available on microfiche.
|
19 |
Failure analysis of ultra-high molecular weight polyethyelene acetabular cupsBurger, Nicolaas Daniel Lombard. January 2005 (has links)
Thesis (PhD.(Mechanical Engineering))--University of Pretoria, 2005. / Includes summary. Includes bibliographical references. Available on the Internet via the World Wide Web.
|
20 |
Pressure distribution on the human hip joint In vivo and selection of hemiarthroplastyHalcomb, Francis Joseph. January 1980 (has links)
Thesis: M.S., Massachusetts Institute of Technology, Department of Mechanical Engineering, 1980 / Bibliography: leaves 216-232. / by Francis Joseph Halcomb, III. / M.S. / M.S. Massachusetts Institute of Technology, Department of Mechanical Engineering
|
Page generated in 0.0548 seconds