Short-term variation during asbestos abatement activities

Jones, Erle Baxter, 1953- January 1987 (has links)
The fibrous aerosol monitor (FAM) was designed to count fibrous particulates as accurately as the standard method, P & CAM 239, now NIOSH 7400. The Hi-Vol (HV) method, a modification of the standard method, was developed to collect fibers over a shorter time interval (i.e., 10-minutes) with the same accuracy as the standard method. The current study sought to compare the HV method with the FAM to assess its validity in measuring airborne asbestos levels and to assess the importance of short-term variation in asbestos levels in determining appropriate respiratory protection. Correlation between the FAM and HV showed a poor linear relationship in all comparison studies. However, there was good correlation between the average of short-term HV samples and long-term time-weighted average (TWA) samples at reported low levels of airborne asbestos. All membrane filter techniques showed strong correlation with each other, but were weakly correlated with the FAM. (Abstract shortened with permission of author.)