Spelling suggestions: "subject:"automated perimetry"" "subject:"utomated perimetry""
1 |
Evidence for a learning effect in short-wavelength automated perimetry.Wild, J.M., Kim, L.S,, Pacey, Ian E., Cunliffe, I.A. January 2006 (has links)
No / Purpose
To document the magnitude of any learning effect for short-wavelength automated perimetry (SWAP) in patients with either ocular hypertension (OHT) or open-angle glaucoma (OAG) who are experienced in standard automated perimetry (SAP).
Participants
Thirty-five patients (22 with OHT and 13 with OAG) who had previously undergone at least 3 threshold SAP visual field examinations with the Humphrey Field Analyzer (HFA; Carl Zeiss Meditech Inc., Dublin, CA), and 9 patients with OHT who had not previously undertaken any form of perimetry.
Methods
Each patient attended for SWAP on 5 occasions, each separated by 1 week. At each visit, both eyes were examined using Program 24-2 of the HFA; the right eye was always examined before the left eye.
Main Outcome Measures
(1) Change over the 5 examinations, in each eye, of the visual field indices Mean Deviation (MD), Short-term Fluctuation (SF), Pattern Standard Deviation (PSD), and Corrected Pattern Standard Deviation. (2) Change in each eye between Visits 1 and 5 in proportionate Mean Sensitivity (pMS) for the central annulus of stimulus locations compared with that for the peripheral annulus thereby determining the influence of stimulus eccentricity on any alteration in sensitivity. (3) Change between Visits 1 and 5 in the number and magnitude of the Pattern Deviation (PD) probability levels associated with any alteration in sensitivity.
Results
The MD, SF, and PSD each improved over the 5 examinations (each at P<0.001). The improvement in pMS between Visits 1 and 5 was greater for the peripheral annulus than for the central annulus by approximately twofold for the patients with OAG. Considerable variation was present between patients, within and between groups, in the number of locations exhibiting an improving sensitivity between Visits 1 and 5 by 1 or more PD probability levels.
Conclusions
Care should be taken to ensure that, during the initial examinations, apparent field loss with SWAP in patients exhibiting a normal field by SAP is not the result of inexperience in SWAP. Apparently deeper or wider field loss in the initial examinations with SWAP compared with that exhibited by SAP in OAG also may arise from inexperience in SWAP.
|
2 |
Towards patient-tailored perimetry: automated perimetry can be improved by seeding procedures with patient-specific structural informationDenniss, Jonathan, McKendrick, A.M., Turpin, A. 31 May 2013 (has links)
No / To explore the performance of patient-specific prior information, for example, from structural imaging, in improving perimetric procedures.
Computer simulation was used to determine the error distribution and presentation count for Structure–Zippy Estimation by Sequential Testing (ZEST), a Bayesian procedure with prior distribution centered on a threshold prediction from structure. Structure-ZEST (SZEST) was trialled for single locations with combinations of true and predicted thresholds between 1 to 35 dB, and compared with a standard procedure with variability similar to Swedish Interactive Thresholding Algorithm (SITA) (Full-Threshold, FT). Clinical tests of glaucomatous visual fields (n = 163, median mean deviation −1.8 dB, 90% range +2.1 to −22.6 dB) were also compared between techniques.
For single locations, SZEST typically outperformed FT when structural predictions were within ± 9 dB of true sensitivity, depending on response errors. In damaged locations, mean absolute error was 0.5 to 1.8 dB lower, SD of threshold estimates was 1.2 to 1.5 dB lower, and 2 to 4 (29%–41%) fewer presentations were made for SZEST. Gains were smaller across whole visual fields (SZEST, mean absolute error: 0.5 to 1.2 dB lower, threshold estimate SD: 0.3 to 0.8 dB lower, 1 [17%] fewer presentation). The 90% retest limits of SZEST were median 1 to 3 dB narrower and more consistent (interquartile range 2–8 dB narrower) across the dynamic range than those for FT.
Seeding Bayesian perimetric procedures with structural measurements can reduce test variability of perimetry in glaucoma, despite imprecise structural predictions of threshold.
Structural data can reduce the variability of current perimetric techniques. A strong structure–function relationship is not necessary, however, structure must predict function within ±9 dB for gains to be realized.
|
3 |
Functional Monitoring after Trabeculectomy or XEN Microstent Implantation Using Spectral Domain Optical Coherence Tomography and Visual Field Indices—A Retrospective Comparative Cohort StudySchargus, Marc, Busch, Catharina, Rehak, Matus, Meng, Jie, Schmidt, Manuela, Bormann, Caroline, Unterlauft, Jan Darius 27 April 2023 (has links)
The aim of this study was to compare the efficacy of trabeculectomy (TE), single XEN microstent implantation (solo XEN) or combined XEN implantation and cataract surgery (combined XEN) in primary open-angle glaucoma cases, naïve to prior surgical treatment, using a monocentric retrospective comparative cohort study. Intraocular pressure (IOP) and the number of IOP-lowering drugs (Meds) were monitored during the first 24 months after surgery. Further disease progression was monitored using peripapillary retinal nerve fiber layer (RNFL) thickness examinations using spectral domain optical coherence tomography (OCT) as well as visual acuity (VA) and visual field (VF) tests. In the TE group (52 eyes), the mean IOP decreased from 24.9 ± 5.9 to 13.9 ± 4.2 mmHg (p < 0.001) and Meds decreased from 3.2 ± 1.2 to 0.5 ± 1.1 (p < 0.001). In the solo XEN (38 eyes) and the combined XEN groups, the mean IOP decreased from 24.1 ± 4.7 to 15.7 ± 3.0 mmHg (p < 0.001) and 25.4 ± 5.6 to 14.7 ± 3.2 mmHg (p < 0.001), while Meds decreased from 3.3 ± 0.8 to 0.8 ± 1.2 (p < 0.001) and 2.7 ± 1.2 to 0.4 ± 1.0 (p < 0.001), respectively. The VF and VA indices showed no sign of further deterioration, the RNFL thickness further decreased in all treatment groups after surgery. TE and XEN led to comparable reductions in IOP and Meds. Although the VA and VF indices remained unaltered, the RNFL thickness continuously decreased in all treatment groups during the 24-month follow-up.
|
Page generated in 0.0947 seconds