• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização do filtro de Kalman para sinais de ECG em desfibriladores externos automáticos

Cardoso, Yang Medeiros 19 December 2016 (has links)
Submitted by Jean Medeiros (jeanletras@uepb.edu.br) on 2017-04-06T14:46:22Z No. of bitstreams: 1 PDF - Yang Medeiros Cardoso.pdf: 13425632 bytes, checksum: 72b354ab3844ba38f7747c1b7a2f9948 (MD5) / Approved for entry into archive by Secta BC (secta.csu.bc@uepb.edu.br) on 2017-07-20T11:33:31Z (GMT) No. of bitstreams: 1 PDF - Yang Medeiros Cardoso.pdf: 13425632 bytes, checksum: 72b354ab3844ba38f7747c1b7a2f9948 (MD5) / Made available in DSpace on 2017-07-20T11:33:31Z (GMT). No. of bitstreams: 1 PDF - Yang Medeiros Cardoso.pdf: 13425632 bytes, checksum: 72b354ab3844ba38f7747c1b7a2f9948 (MD5) Previous issue date: 2016-12-19 / Cardiac arrest is one of the most common causes of death in the world. Among the people who can be saved from this condition, most are in Ventricular Fibrillation or Pulseless Ventricular Tachycardia. Electrical defibrillation is the simplest and most important therapy in the treatment of these patients. The Automatic External Defibrillator is the device that can be used by laypersons with a minimum of training to perform defibrillation, reducing the waiting time of the first pulse application, which directly influenciate the success rate of this therapy. This work describes a way of using the Extended Kalman Filter (FKE) to correct ECG signals used by an Automatic External Defibrillator in the decision making of the defibrillatory pulse application in patients, as well as a proposed Defibrillator model describing the aspects of its operation. / A parada cardíaca é uma das causas mais comuns de morte no mundo. Dentre as pessoas que podem ser salvas dessa condição, a maioria encontra-se em Fibrilação Ventricular ou Taquicardia Ventricular sem pulso. A Desfibrilação Elétrica é a terapia mais simples e importante no tratamento desses pacientes. O Desfibrilador Externo Automático é o aparelho que pode ser utilizado por leigos com um mínimo de treinamento para efetuar a Desfibrilação, diminuindo o tempo de espera da aplicação do primeiro pulso, o que influencia diretamente na taxa de sucesso dessa terapia. Neste trabalho descreve-se uma forma de utilização do Filtro de Kalman Estendido (FKE) para corrigir sinais de ECG utilizados por um Desfibrilador Externo Automático na tomada de decisão da aplicação do pulso desfibrilatório em pacientes, bem como uma proposta modelo de Desfibrilador que descreve os aspectos principais do seu funcionamento.

Page generated in 0.122 seconds