• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 8
  • 8
  • 8
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A crise de água e sua possível relação com os parcos remanescentes florestais na Região Oeste do Estado de Santa Catarina /

Doubrawa, Amanda, Sevegnani, Lúcia, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2007 (has links) (PDF)
Orientadora: Lúcia Sevegnani. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação de Engenharia Ambiental.
2

Aprimoramento estatístico da regionalização de vazões máximas e médias. Aplicação a bacias hidrográficas do Rio Grande do Sul e Santa Catarina

Brusa, Luis Carlos January 2004 (has links)
Os registros de vazões líquidas obtidos das estações fluviométricas são válidos, unicamente, para o local de onde foram coletados ou muito próximo a ele. Na maioria das vezes, a região de influência deste não inclui o local de interesse para o desenvolvimento de projetos de recursos hídricos. Este inconveniente, geralmente, pode ser resolvido através do uso de métodos de regionalização hidrológica. Para determinar os coeficientes da equação de regionalização, o procedimento mais usado consiste em: i) estabelecer uma relação do tipo exponencial multivariada entre a variável dependente (vazão média de longo prazo ou média anual de cheia) e as covariáveis (variáveis climáticas e fisiográficas da bacia hidrográfica); ii) linearizar a equação anterior mediante a transformação logarítmica de ambos os membros; iii) utilizar modelos lineares de regressão para estimar os coeficientes, geralmente, o método dos mínimos quadrados ordinários; e iv) aplicar a transformação inversa para definir a equação. A aplicação deste procedimento implica assumir certas propriedades dos dados (assimetria positiva, registros da mesma extensão e que os mesmos possuem o mesmo período de início e fim, entre outros) que dificilmente podem ser atendidas, prejudicando a verificação das hipóteses nas quais estão baseados os métodos lineares de regressão e, em conseqüência, seu adequado uso, bem como a confiabilidade dos resultados obtidos. Esta pesquisa apresenta um aprimoramento dos métodos de regionalização de vazões geralmente empregados, incluindo-se técnicas que levam em consideração as limitações anteriores. Estas técnicas foram: i) uso da transformada de Box-Cox na linearização da equação exponencial multivariada; ii) determinação dos coeficientes da equação de regionalização usando mínimos quadrados ponderados; e iii) verificação se os resíduos da regressão estão correlacionados ou não. Para o desenvolvimento e verificação da metodologia proposta foram usados somente registros fluviométricos de Bacias Hidrográficas Brasileiras, que drenam suas águas para o Rio Grande do Sul e/ou que estejam localizadas dentro dele. Geograficamente, a área de estudo inclui a totalidade do estado do Rio Grande do Sul e parte de Santa Catarina. As equações de regionalização foram definidas usando dados de vazões médias de longo prazo e média de cheia, para tempo de retorno de 2,33 e 50 anos. Neste último caso, as freqüências foram estimadas através do método dos momentos-L.Comparando os resultados obtidos utilizando o modelo de regionalização hidrológica proposto neste trabalho (transformada de Box-Cox / mínimos quadrados ponderados) junto a seus similares gerados usando a metodologia convencional (transformada logarítmica / mínimos quadrados ordinários) e de modelos intermediários (transformada logarítmica / mínimos quadrados ponderados e transformada de Box-Cox / mínimos quadrados ordinários), os mesmos podem ser considerados satisfatórios, visto que em todas as simulações realizadas o modelo proposto forneceu melhores resultados que aqueles obtidos com os outros modelos, sendo utilizado como padrão de comparação: 1) a qualidade do ajuste, 2) o grau de verificação das hipóteses dos métodos lineares de regressão e 3) os erros na estimativa das descargas, em termos de vazão específica. Nas simulações realizadas usando os modelos intermediários, observou-se que: i) na regionalização de vazões médias, o ganho de considerar a heterogeneidade temporal dos dados é maior do que corrigir a assimetria dos mesmos; ii) quando são usadas séries de descargas máximas, ocorre o efeito contrário, visto que o ganho de corrigir a assimetria das séries é maior do que o efeito da heterogeneidade temporal dos dados. Com relação aos resíduos da regressão, contrariamente ao esperado, os mesmos não sugerem estar correlacionados; isto pode ser conseqüência de utilizar como variável dependente um único registro por estação (vazão média de longo prazo ou média anual de cheia).
3

Aprimoramento estatístico da regionalização de vazões máximas e médias. Aplicação a bacias hidrográficas do Rio Grande do Sul e Santa Catarina

Brusa, Luis Carlos January 2004 (has links)
Os registros de vazões líquidas obtidos das estações fluviométricas são válidos, unicamente, para o local de onde foram coletados ou muito próximo a ele. Na maioria das vezes, a região de influência deste não inclui o local de interesse para o desenvolvimento de projetos de recursos hídricos. Este inconveniente, geralmente, pode ser resolvido através do uso de métodos de regionalização hidrológica. Para determinar os coeficientes da equação de regionalização, o procedimento mais usado consiste em: i) estabelecer uma relação do tipo exponencial multivariada entre a variável dependente (vazão média de longo prazo ou média anual de cheia) e as covariáveis (variáveis climáticas e fisiográficas da bacia hidrográfica); ii) linearizar a equação anterior mediante a transformação logarítmica de ambos os membros; iii) utilizar modelos lineares de regressão para estimar os coeficientes, geralmente, o método dos mínimos quadrados ordinários; e iv) aplicar a transformação inversa para definir a equação. A aplicação deste procedimento implica assumir certas propriedades dos dados (assimetria positiva, registros da mesma extensão e que os mesmos possuem o mesmo período de início e fim, entre outros) que dificilmente podem ser atendidas, prejudicando a verificação das hipóteses nas quais estão baseados os métodos lineares de regressão e, em conseqüência, seu adequado uso, bem como a confiabilidade dos resultados obtidos. Esta pesquisa apresenta um aprimoramento dos métodos de regionalização de vazões geralmente empregados, incluindo-se técnicas que levam em consideração as limitações anteriores. Estas técnicas foram: i) uso da transformada de Box-Cox na linearização da equação exponencial multivariada; ii) determinação dos coeficientes da equação de regionalização usando mínimos quadrados ponderados; e iii) verificação se os resíduos da regressão estão correlacionados ou não. Para o desenvolvimento e verificação da metodologia proposta foram usados somente registros fluviométricos de Bacias Hidrográficas Brasileiras, que drenam suas águas para o Rio Grande do Sul e/ou que estejam localizadas dentro dele. Geograficamente, a área de estudo inclui a totalidade do estado do Rio Grande do Sul e parte de Santa Catarina. As equações de regionalização foram definidas usando dados de vazões médias de longo prazo e média de cheia, para tempo de retorno de 2,33 e 50 anos. Neste último caso, as freqüências foram estimadas através do método dos momentos-L.Comparando os resultados obtidos utilizando o modelo de regionalização hidrológica proposto neste trabalho (transformada de Box-Cox / mínimos quadrados ponderados) junto a seus similares gerados usando a metodologia convencional (transformada logarítmica / mínimos quadrados ordinários) e de modelos intermediários (transformada logarítmica / mínimos quadrados ponderados e transformada de Box-Cox / mínimos quadrados ordinários), os mesmos podem ser considerados satisfatórios, visto que em todas as simulações realizadas o modelo proposto forneceu melhores resultados que aqueles obtidos com os outros modelos, sendo utilizado como padrão de comparação: 1) a qualidade do ajuste, 2) o grau de verificação das hipóteses dos métodos lineares de regressão e 3) os erros na estimativa das descargas, em termos de vazão específica. Nas simulações realizadas usando os modelos intermediários, observou-se que: i) na regionalização de vazões médias, o ganho de considerar a heterogeneidade temporal dos dados é maior do que corrigir a assimetria dos mesmos; ii) quando são usadas séries de descargas máximas, ocorre o efeito contrário, visto que o ganho de corrigir a assimetria das séries é maior do que o efeito da heterogeneidade temporal dos dados. Com relação aos resíduos da regressão, contrariamente ao esperado, os mesmos não sugerem estar correlacionados; isto pode ser conseqüência de utilizar como variável dependente um único registro por estação (vazão média de longo prazo ou média anual de cheia).
4

Aprimoramento estatístico da regionalização de vazões máximas e médias. Aplicação a bacias hidrográficas do Rio Grande do Sul e Santa Catarina

Brusa, Luis Carlos January 2004 (has links)
Os registros de vazões líquidas obtidos das estações fluviométricas são válidos, unicamente, para o local de onde foram coletados ou muito próximo a ele. Na maioria das vezes, a região de influência deste não inclui o local de interesse para o desenvolvimento de projetos de recursos hídricos. Este inconveniente, geralmente, pode ser resolvido através do uso de métodos de regionalização hidrológica. Para determinar os coeficientes da equação de regionalização, o procedimento mais usado consiste em: i) estabelecer uma relação do tipo exponencial multivariada entre a variável dependente (vazão média de longo prazo ou média anual de cheia) e as covariáveis (variáveis climáticas e fisiográficas da bacia hidrográfica); ii) linearizar a equação anterior mediante a transformação logarítmica de ambos os membros; iii) utilizar modelos lineares de regressão para estimar os coeficientes, geralmente, o método dos mínimos quadrados ordinários; e iv) aplicar a transformação inversa para definir a equação. A aplicação deste procedimento implica assumir certas propriedades dos dados (assimetria positiva, registros da mesma extensão e que os mesmos possuem o mesmo período de início e fim, entre outros) que dificilmente podem ser atendidas, prejudicando a verificação das hipóteses nas quais estão baseados os métodos lineares de regressão e, em conseqüência, seu adequado uso, bem como a confiabilidade dos resultados obtidos. Esta pesquisa apresenta um aprimoramento dos métodos de regionalização de vazões geralmente empregados, incluindo-se técnicas que levam em consideração as limitações anteriores. Estas técnicas foram: i) uso da transformada de Box-Cox na linearização da equação exponencial multivariada; ii) determinação dos coeficientes da equação de regionalização usando mínimos quadrados ponderados; e iii) verificação se os resíduos da regressão estão correlacionados ou não. Para o desenvolvimento e verificação da metodologia proposta foram usados somente registros fluviométricos de Bacias Hidrográficas Brasileiras, que drenam suas águas para o Rio Grande do Sul e/ou que estejam localizadas dentro dele. Geograficamente, a área de estudo inclui a totalidade do estado do Rio Grande do Sul e parte de Santa Catarina. As equações de regionalização foram definidas usando dados de vazões médias de longo prazo e média de cheia, para tempo de retorno de 2,33 e 50 anos. Neste último caso, as freqüências foram estimadas através do método dos momentos-L.Comparando os resultados obtidos utilizando o modelo de regionalização hidrológica proposto neste trabalho (transformada de Box-Cox / mínimos quadrados ponderados) junto a seus similares gerados usando a metodologia convencional (transformada logarítmica / mínimos quadrados ordinários) e de modelos intermediários (transformada logarítmica / mínimos quadrados ponderados e transformada de Box-Cox / mínimos quadrados ordinários), os mesmos podem ser considerados satisfatórios, visto que em todas as simulações realizadas o modelo proposto forneceu melhores resultados que aqueles obtidos com os outros modelos, sendo utilizado como padrão de comparação: 1) a qualidade do ajuste, 2) o grau de verificação das hipóteses dos métodos lineares de regressão e 3) os erros na estimativa das descargas, em termos de vazão específica. Nas simulações realizadas usando os modelos intermediários, observou-se que: i) na regionalização de vazões médias, o ganho de considerar a heterogeneidade temporal dos dados é maior do que corrigir a assimetria dos mesmos; ii) quando são usadas séries de descargas máximas, ocorre o efeito contrário, visto que o ganho de corrigir a assimetria das séries é maior do que o efeito da heterogeneidade temporal dos dados. Com relação aos resíduos da regressão, contrariamente ao esperado, os mesmos não sugerem estar correlacionados; isto pode ser conseqüência de utilizar como variável dependente um único registro por estação (vazão média de longo prazo ou média anual de cheia).
5

O papel dos comitês de bacias de Santa Catarina no sistema nacional e estadual de gerenciamento de recursos hídricos

Madruga, Flávia do Nascimento [UNESP] 17 October 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-10-17Bitstream added on 2014-06-13T19:26:28Z : No. of bitstreams: 1 madruga_fn_me_rcla.pdf: 602399 bytes, checksum: d87f99c9718cfb1252754ffad0a1b32e (MD5) / Os Comitês de Gerenciamento de Bacias Hidrograticas têm sido objeto de uma série de estudos de caso, que apresentam as particularidades da formação, representação e atuação destes Comitês sem situá-Ios em um contexto maior. Neste trabalho procura-se mostrar uma visão geral da importância dada aos problemas ambientais a partir das últimas décadas do século XX, e, em especial, a importância assumida pelas questões de manejo, recuperação e conservação dos recursos hídricos no Brasil. São apresentados de modo detalhado o Sistema de Gerenciamento de Recursos Hídricos do Brasil, de 1997, e de Santa Catarina, de 1994, a fim de mostrar o papel dos Comitês de Gerenciamento de Bacias Hidrográficas nestes Sistemas. Tratando de modo mais específico, foram apresentadas as potencialidades e as dificuldades da atuação e o trabalho dos 16 Comitês de Gerenciamento de Bacias Hidrográficas no Estado de Santa Catarina, dentro da metodologia do Sistema de Gerenciamento de Recursos Hídricos que as idealizou. Por fim, são apontadas as contribuições que a Geografia pode dar ao processo de gestão de recursos hídricos no Brasil. / The Committees of Hydrographic Basins Management have been object of many case studies, witch show the particularities of formation, representation and actuation of these Committees, without pointing out them in a bigger context. In this work the aim is to display a general view of the importance concerning to the enviromental questions from the last decades of the XX century and, specially, the value assumed by the hydrical resources' management, recovering and conservation issues in Brazil. It's detailed Brazil's (1997) and Santa Catarina's (1994) Hydric Resource Management Systems, intending to reveal the role of the committees of hydrographic basins in those Systems. More specifically, have been presented potentialities and difficulties in the actuation and the work of the 16 Committees of Management of Hydrographic Basins in the State of Santa Catarina, within the methodology of the Hydric Resources Management System that idealized them. To conclude, have been pointed out the contributions with which Geography can suply the process of hydrical resources management in Brazil.
6

Desenvolvimento de um índice de umidade do solo derivado da versão distribuída do Tank Model

Vasconcellos, Sofia Melo January 2017 (has links)
Soil moisture can be a determining factor in hydrological processes. However, the monitoring of soil water content is difficult to perform because of its spatio-temporal variability and because field measurements are expensive and time-consuming. Thus, the use of the Tank Model and also a moisture index derived from this model can be very useful in hydrological studies and in the management of natural disasters. In addition, the evaluation of this index in a distributed form in the river basin allows a more detailed analysis of the water content of the soil, considering its spatial variability. The objective of this study was to develop a distributed version of the Tank Model (D-Tank Model) to determine a soil moisture content (IUS), dividing the basin into cells with a resolution of 2 meters. The study area was the Araponga River basin (5.26 ha), located in the north of Santa Catarina, and with hydro-meteorological and tensiometric data available. In the study, data were used every 5 minutes of rainfall, evapotranspiration and flow, and soil water tension every 10 minutes, measured from March 2011 to December 2015. Initially the Tank Model was used, Aiming only at the rain-flow process of the basin for five short-duration events aiming at the calibration of the parameters, which were also used in the D-Tank Model cells. The validation of this transfer of parameters was done using the average of the parameters found in the calibration, applying it in two other short duration events. After validation, the water storage in the soil of each of the basin cells generated for the D-Tank Model was calculated. With the D-Tank Model, the IUS values were obtained, which were compared with the soil water tension values measured by the tensiometers. The individual storage values of the two reservoirs S1, and S2, were also compared with the water tension values. The comparison was made through the linear correlation coefficient, seeking negative correlations between the variables, which occurred in a satisfactory way, both between the IUS and the tension values, as well as the storage values of the reservoirs and the water tension values. The present work showed that IUS may be an applicable measure for soil moisture representation. / A umidade do solo pode ser um fator determinante nos processos hidrológicos. No entanto, o monitoramento do conteúdo de água no solo é difícil de ser realizado, devido à sua variabilidade espaço-temporal e porque as medições de campo são dispendiosas e demoradas. Assim, a utilização do Tank Model e também de um índice de umidade, derivado deste modelo, podem ser muito úteis nos estudos hidrológicos. Além disso, a avaliação desse índice de forma distribuída na bacia hidrográfica permite uma análise mais detalhada do conteúdo de água do solo, uma vez que considera a sua variabilidade espacial. O objetivo deste estudo foi desenvolver uma versão distribuída do Tank Model (D-Tank Model), para determinar um índice de umidade do solo (IUS), dividindo a bacia em células com resolução de 2 metros. A área de estudo foi a bacia hidrográfica do Rio Araponga (5,26 ha), localizada no norte de Santa Catarina, e com disponibilidade de dados hidro-meteorológicos e tensiométricos. No estudo foram utilizados dados a cada 5 minutos de precipitação, evapotranspiração e vazão, e de tensão de água no solo a cada 10 minutos, medidos no período de março de 2011 a dezembro de 2015. Inicialmente foi utilizado o Tank Model (concentrado), visando somente o processo chuva-vazão da bacia para cinco eventos de curta-duração visando a calibração dos parâmetros, que foram também utilizados nas células do D-Tank Model. A validação desta transferência de parâmetros se deu utilizando a média dos parâmetros encontrados na calibração, aplicando-a em outros dois eventos de curta duração. Após a validação, foi calculado o armazenamento de água no solo, de cada uma das células da bacia, geradas para o D-Tank Model. Com o D-Tank Model obteve-se os valores de IUS, que foram comparados com os valores de tensão da água no solo, medidos pelos tensiômetros. Os valores de armazenamento individuais dos dois reservatórios S1, e S2, também foram comparados com os valores de tensão. A comparação foi feita através do coeficiente de correlação linear, buscando correlações negativas entre as variáveis, o que ocorreu de forma satisfatória, tanto entre o IUS e os valores de tensão, como para os valores de armazenamento dos reservatórios e os valores de tensão da água no solo. O presente trabalho mostrou que o IUS pode ser uma medida aplicável para representação da umidade do solo.
7

Desenvolvimento de um índice de umidade do solo derivado da versão distribuída do Tank Model

Vasconcellos, Sofia Melo January 2017 (has links)
Soil moisture can be a determining factor in hydrological processes. However, the monitoring of soil water content is difficult to perform because of its spatio-temporal variability and because field measurements are expensive and time-consuming. Thus, the use of the Tank Model and also a moisture index derived from this model can be very useful in hydrological studies and in the management of natural disasters. In addition, the evaluation of this index in a distributed form in the river basin allows a more detailed analysis of the water content of the soil, considering its spatial variability. The objective of this study was to develop a distributed version of the Tank Model (D-Tank Model) to determine a soil moisture content (IUS), dividing the basin into cells with a resolution of 2 meters. The study area was the Araponga River basin (5.26 ha), located in the north of Santa Catarina, and with hydro-meteorological and tensiometric data available. In the study, data were used every 5 minutes of rainfall, evapotranspiration and flow, and soil water tension every 10 minutes, measured from March 2011 to December 2015. Initially the Tank Model was used, Aiming only at the rain-flow process of the basin for five short-duration events aiming at the calibration of the parameters, which were also used in the D-Tank Model cells. The validation of this transfer of parameters was done using the average of the parameters found in the calibration, applying it in two other short duration events. After validation, the water storage in the soil of each of the basin cells generated for the D-Tank Model was calculated. With the D-Tank Model, the IUS values were obtained, which were compared with the soil water tension values measured by the tensiometers. The individual storage values of the two reservoirs S1, and S2, were also compared with the water tension values. The comparison was made through the linear correlation coefficient, seeking negative correlations between the variables, which occurred in a satisfactory way, both between the IUS and the tension values, as well as the storage values of the reservoirs and the water tension values. The present work showed that IUS may be an applicable measure for soil moisture representation. / A umidade do solo pode ser um fator determinante nos processos hidrológicos. No entanto, o monitoramento do conteúdo de água no solo é difícil de ser realizado, devido à sua variabilidade espaço-temporal e porque as medições de campo são dispendiosas e demoradas. Assim, a utilização do Tank Model e também de um índice de umidade, derivado deste modelo, podem ser muito úteis nos estudos hidrológicos. Além disso, a avaliação desse índice de forma distribuída na bacia hidrográfica permite uma análise mais detalhada do conteúdo de água do solo, uma vez que considera a sua variabilidade espacial. O objetivo deste estudo foi desenvolver uma versão distribuída do Tank Model (D-Tank Model), para determinar um índice de umidade do solo (IUS), dividindo a bacia em células com resolução de 2 metros. A área de estudo foi a bacia hidrográfica do Rio Araponga (5,26 ha), localizada no norte de Santa Catarina, e com disponibilidade de dados hidro-meteorológicos e tensiométricos. No estudo foram utilizados dados a cada 5 minutos de precipitação, evapotranspiração e vazão, e de tensão de água no solo a cada 10 minutos, medidos no período de março de 2011 a dezembro de 2015. Inicialmente foi utilizado o Tank Model (concentrado), visando somente o processo chuva-vazão da bacia para cinco eventos de curta-duração visando a calibração dos parâmetros, que foram também utilizados nas células do D-Tank Model. A validação desta transferência de parâmetros se deu utilizando a média dos parâmetros encontrados na calibração, aplicando-a em outros dois eventos de curta duração. Após a validação, foi calculado o armazenamento de água no solo, de cada uma das células da bacia, geradas para o D-Tank Model. Com o D-Tank Model obteve-se os valores de IUS, que foram comparados com os valores de tensão da água no solo, medidos pelos tensiômetros. Os valores de armazenamento individuais dos dois reservatórios S1, e S2, também foram comparados com os valores de tensão. A comparação foi feita através do coeficiente de correlação linear, buscando correlações negativas entre as variáveis, o que ocorreu de forma satisfatória, tanto entre o IUS e os valores de tensão, como para os valores de armazenamento dos reservatórios e os valores de tensão da água no solo. O presente trabalho mostrou que o IUS pode ser uma medida aplicável para representação da umidade do solo.
8

Desenvolvimento de um índice de umidade do solo derivado da versão distribuída do Tank Model

Vasconcellos, Sofia Melo January 2017 (has links)
Soil moisture can be a determining factor in hydrological processes. However, the monitoring of soil water content is difficult to perform because of its spatio-temporal variability and because field measurements are expensive and time-consuming. Thus, the use of the Tank Model and also a moisture index derived from this model can be very useful in hydrological studies and in the management of natural disasters. In addition, the evaluation of this index in a distributed form in the river basin allows a more detailed analysis of the water content of the soil, considering its spatial variability. The objective of this study was to develop a distributed version of the Tank Model (D-Tank Model) to determine a soil moisture content (IUS), dividing the basin into cells with a resolution of 2 meters. The study area was the Araponga River basin (5.26 ha), located in the north of Santa Catarina, and with hydro-meteorological and tensiometric data available. In the study, data were used every 5 minutes of rainfall, evapotranspiration and flow, and soil water tension every 10 minutes, measured from March 2011 to December 2015. Initially the Tank Model was used, Aiming only at the rain-flow process of the basin for five short-duration events aiming at the calibration of the parameters, which were also used in the D-Tank Model cells. The validation of this transfer of parameters was done using the average of the parameters found in the calibration, applying it in two other short duration events. After validation, the water storage in the soil of each of the basin cells generated for the D-Tank Model was calculated. With the D-Tank Model, the IUS values were obtained, which were compared with the soil water tension values measured by the tensiometers. The individual storage values of the two reservoirs S1, and S2, were also compared with the water tension values. The comparison was made through the linear correlation coefficient, seeking negative correlations between the variables, which occurred in a satisfactory way, both between the IUS and the tension values, as well as the storage values of the reservoirs and the water tension values. The present work showed that IUS may be an applicable measure for soil moisture representation. / A umidade do solo pode ser um fator determinante nos processos hidrológicos. No entanto, o monitoramento do conteúdo de água no solo é difícil de ser realizado, devido à sua variabilidade espaço-temporal e porque as medições de campo são dispendiosas e demoradas. Assim, a utilização do Tank Model e também de um índice de umidade, derivado deste modelo, podem ser muito úteis nos estudos hidrológicos. Além disso, a avaliação desse índice de forma distribuída na bacia hidrográfica permite uma análise mais detalhada do conteúdo de água do solo, uma vez que considera a sua variabilidade espacial. O objetivo deste estudo foi desenvolver uma versão distribuída do Tank Model (D-Tank Model), para determinar um índice de umidade do solo (IUS), dividindo a bacia em células com resolução de 2 metros. A área de estudo foi a bacia hidrográfica do Rio Araponga (5,26 ha), localizada no norte de Santa Catarina, e com disponibilidade de dados hidro-meteorológicos e tensiométricos. No estudo foram utilizados dados a cada 5 minutos de precipitação, evapotranspiração e vazão, e de tensão de água no solo a cada 10 minutos, medidos no período de março de 2011 a dezembro de 2015. Inicialmente foi utilizado o Tank Model (concentrado), visando somente o processo chuva-vazão da bacia para cinco eventos de curta-duração visando a calibração dos parâmetros, que foram também utilizados nas células do D-Tank Model. A validação desta transferência de parâmetros se deu utilizando a média dos parâmetros encontrados na calibração, aplicando-a em outros dois eventos de curta duração. Após a validação, foi calculado o armazenamento de água no solo, de cada uma das células da bacia, geradas para o D-Tank Model. Com o D-Tank Model obteve-se os valores de IUS, que foram comparados com os valores de tensão da água no solo, medidos pelos tensiômetros. Os valores de armazenamento individuais dos dois reservatórios S1, e S2, também foram comparados com os valores de tensão. A comparação foi feita através do coeficiente de correlação linear, buscando correlações negativas entre as variáveis, o que ocorreu de forma satisfatória, tanto entre o IUS e os valores de tensão, como para os valores de armazenamento dos reservatórios e os valores de tensão da água no solo. O presente trabalho mostrou que o IUS pode ser uma medida aplicável para representação da umidade do solo.

Page generated in 0.1207 seconds