• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de uma planta piloto para a combustão em leito fluidizado borbulhante de carvões minerais brasileiros com altos teores de cinzas e enxofre / not availalbe

Tureso, João Paulo 12 November 2004 (has links)
O carvão mineral nacional representa uma alternativa atraente para a solução do problema energético do Brasil. Os maiores problemas técnicos associados à queima dos carvões minerais brasileiros referem-se à emissões de gases poluentes de enxofre e nitrogênio e a problemas causados por fusão de cinzas. Por outro lado, a queima eficiente e limpa de biomassa e resíduos industriais entre outros materiais combustíveis, pode trazer benefícios ambientais consideráveis. O processo de combustão em leito fluidizado é reconhecidamente flexível quanto ao uso de combustível, trabalha com baixas temperaturas que evitam a fusão de cinzas e diminuem a emissão de NOx e permite a remoção de SOx ainda dentro do leito, por meio da adição de calcário o que dispensa tratamento adicional para este gás. Considerando o exposto acima, uma planta piloto de combustão em leito fluidizado foi projetada e construída no NETeF da EESC/USP e utilizada inicialmente para testes de remoção de SO2 durante a queima de carvão. A concepção e construção do reator e de seus periféricos são discutidas e os resultados são apresentados. Na absorção de SO2 duas variáveis foram consideradas; a relação molar Ca/S e o excesso de ar de combustão. Os resultados mostram eficiência de remoção de SO2 de até 94% para relação Ca/S = 4 e excesso de ar de 21%. Para a relação Ca/S = 1, a mais baixa utilizada neste trabalho e que representa a condição estequiométrica, este valor cai para 55%. O excesso de ar mostrou um papel claro, porém mais modesto. A redução do excesso de ar de 21% para a condição estequiométrica levou a eficiência de 94 para 84%. / The utilization of coal is an attractive way to reduce some of the energy problems in Brazil. Major problems associated with coal combustion are polutant emissions, mainly SOx and NOx and ash fusion. Additionally, the efficient combustion of biomass and industrial hazardous wastes, among other fuels, can bring a significant environmental benefit. Fluidized bed combustion is recognized to be flexible in the use of fuel, produce low temperature that avoid ash fusion and reduce NOx emissions, and allow SOx absorption by limestone inside the bed, what makes unnecessary additional gas treatment for this pollutant. Considering that, a fluidized bed combustion pilot plant was projected and built in NETeF at EESC/USP and initially used for investigations of the SO2 absorption by limestone during coal combustion. The concept and construction of the plant are presented and discussed and the results are shown. Regarding the absorption of SO2, two variables were investigated, namely the molar ratio Ca/S and the excess of combustion air. An absorption efficiency of up to 94% was achieved with Ca/S = 4 and excess air of 21%. When Ca/S = 1 was used - what represents the stoichiometric ratio and was the lowest used in this work, this efficiency dropped to 55%. Excess air showed a clear but more modest role. The decrease of excess air from 21% to the stoichiometric condition decreased the efficiency from 94 to 84%.
2

Estudo de uma planta piloto para a combustão em leito fluidizado borbulhante de carvões minerais brasileiros com altos teores de cinzas e enxofre / not availalbe

João Paulo Tureso 12 November 2004 (has links)
O carvão mineral nacional representa uma alternativa atraente para a solução do problema energético do Brasil. Os maiores problemas técnicos associados à queima dos carvões minerais brasileiros referem-se à emissões de gases poluentes de enxofre e nitrogênio e a problemas causados por fusão de cinzas. Por outro lado, a queima eficiente e limpa de biomassa e resíduos industriais entre outros materiais combustíveis, pode trazer benefícios ambientais consideráveis. O processo de combustão em leito fluidizado é reconhecidamente flexível quanto ao uso de combustível, trabalha com baixas temperaturas que evitam a fusão de cinzas e diminuem a emissão de NOx e permite a remoção de SOx ainda dentro do leito, por meio da adição de calcário o que dispensa tratamento adicional para este gás. Considerando o exposto acima, uma planta piloto de combustão em leito fluidizado foi projetada e construída no NETeF da EESC/USP e utilizada inicialmente para testes de remoção de SO2 durante a queima de carvão. A concepção e construção do reator e de seus periféricos são discutidas e os resultados são apresentados. Na absorção de SO2 duas variáveis foram consideradas; a relação molar Ca/S e o excesso de ar de combustão. Os resultados mostram eficiência de remoção de SO2 de até 94% para relação Ca/S = 4 e excesso de ar de 21%. Para a relação Ca/S = 1, a mais baixa utilizada neste trabalho e que representa a condição estequiométrica, este valor cai para 55%. O excesso de ar mostrou um papel claro, porém mais modesto. A redução do excesso de ar de 21% para a condição estequiométrica levou a eficiência de 94 para 84%. / The utilization of coal is an attractive way to reduce some of the energy problems in Brazil. Major problems associated with coal combustion are polutant emissions, mainly SOx and NOx and ash fusion. Additionally, the efficient combustion of biomass and industrial hazardous wastes, among other fuels, can bring a significant environmental benefit. Fluidized bed combustion is recognized to be flexible in the use of fuel, produce low temperature that avoid ash fusion and reduce NOx emissions, and allow SOx absorption by limestone inside the bed, what makes unnecessary additional gas treatment for this pollutant. Considering that, a fluidized bed combustion pilot plant was projected and built in NETeF at EESC/USP and initially used for investigations of the SO2 absorption by limestone during coal combustion. The concept and construction of the plant are presented and discussed and the results are shown. Regarding the absorption of SO2, two variables were investigated, namely the molar ratio Ca/S and the excess of combustion air. An absorption efficiency of up to 94% was achieved with Ca/S = 4 and excess air of 21%. When Ca/S = 1 was used - what represents the stoichiometric ratio and was the lowest used in this work, this efficiency dropped to 55%. Excess air showed a clear but more modest role. The decrease of excess air from 21% to the stoichiometric condition decreased the efficiency from 94 to 84%.
3

Integração do tratamento microbiológico com células imobilizadas e tecnologias emergentes (Processos Oxidativos Avançados) para o tratamento de efluentes gerados na indústria têxtil. / Integration of microbiological treatment with immobilized cells and emerging (Advanced Oxidation Process) technologies for wastewater treatment generated in the textile industry.

Oliveira, Ivy dos Santos 13 November 2009 (has links)
A integração de diferentes processos de tratamento na degradação de efluente têxtil foi avaliada utilizando-se a técnica de precipitação, processos oxidativos avançados (POA) e tratamento biológico aeróbio. Os POAs (Ozônio/UV e reagente de Fenton/UV) foram avaliados com experimentos em bateladas de acordo com um planejamento fatorial L18 (Método Tagushi) em função da vazão de ozônio, concentração de reagente Fenton, radiação UV, pH e temperatura. No tratamento microbiológico por processo contínuo, foi utilizado um reator de leito fluidizado com células imobilizadas de zeólitas e avaliados parâmetros como pré-tratamento com POAs, vazão de aeração, taxa de diluição. Concluiu-se que com o pré-tratamento físico-químico obteve-se resultados bastante satisfatórios na redução da DQO e COT, porém gerou uma quantidade desnecessária de lodo. A integração lodo ativado/Reagente Fenton mostrou-se bastante adequada, principalmente na remoção da cor e turbidez; a variedade e freqüência dos microrganismos observados durante o monitoramento biológico foram condizentes com os sistemas de lodo ativado operando eficientemente e o emprego de zeólitas como suporte mostrou-se significativo, alcançando 63,3 % de imobilização do microrganismo no suporte. / The integration of different treatment processes in the degradation of textile wastewater was evaluated using precipitation technique, advanced oxidation processes (AOP) and aerobic biological treatment. AOPs (Ozone/UV and reagent of Fenton/UV) were evaluated in batch experiments according to a factorial planning L18 (Tagushi Method) in function of the flow of ozone, concentration of reagent Fenton, UV radiation, pH and temperature. In the microbiological treatment for continuous process, a reactor of bed fluidized was used with immobilized cells of zeolites some parameters were evaluated such as pre-treatment with AOPs, aeration flow, diluition rate. Satisfactory results were obtained with the physical-chemistry pre-treatment in the reduction of COD and TOC, however it generated an unnecessary amount of sludge. The integration activated sludge/Reagent Fenton was shown quite appropriate, mainly in the removal of the color and turbidity; the variety and frequency of the microorganisms observed during the biological monitorament were suitable with the systems of activated sludge operating efficiently and the use of zeolites as support was shown significant, reaching 63,3 % of immobilization of the microorganism in the support.
4

Integração do tratamento microbiológico com células imobilizadas e tecnologias emergentes (Processos Oxidativos Avançados) para o tratamento de efluentes gerados na indústria têxtil. / Integration of microbiological treatment with immobilized cells and emerging (Advanced Oxidation Process) technologies for wastewater treatment generated in the textile industry.

Ivy dos Santos Oliveira 13 November 2009 (has links)
A integração de diferentes processos de tratamento na degradação de efluente têxtil foi avaliada utilizando-se a técnica de precipitação, processos oxidativos avançados (POA) e tratamento biológico aeróbio. Os POAs (Ozônio/UV e reagente de Fenton/UV) foram avaliados com experimentos em bateladas de acordo com um planejamento fatorial L18 (Método Tagushi) em função da vazão de ozônio, concentração de reagente Fenton, radiação UV, pH e temperatura. No tratamento microbiológico por processo contínuo, foi utilizado um reator de leito fluidizado com células imobilizadas de zeólitas e avaliados parâmetros como pré-tratamento com POAs, vazão de aeração, taxa de diluição. Concluiu-se que com o pré-tratamento físico-químico obteve-se resultados bastante satisfatórios na redução da DQO e COT, porém gerou uma quantidade desnecessária de lodo. A integração lodo ativado/Reagente Fenton mostrou-se bastante adequada, principalmente na remoção da cor e turbidez; a variedade e freqüência dos microrganismos observados durante o monitoramento biológico foram condizentes com os sistemas de lodo ativado operando eficientemente e o emprego de zeólitas como suporte mostrou-se significativo, alcançando 63,3 % de imobilização do microrganismo no suporte. / The integration of different treatment processes in the degradation of textile wastewater was evaluated using precipitation technique, advanced oxidation processes (AOP) and aerobic biological treatment. AOPs (Ozone/UV and reagent of Fenton/UV) were evaluated in batch experiments according to a factorial planning L18 (Tagushi Method) in function of the flow of ozone, concentration of reagent Fenton, UV radiation, pH and temperature. In the microbiological treatment for continuous process, a reactor of bed fluidized was used with immobilized cells of zeolites some parameters were evaluated such as pre-treatment with AOPs, aeration flow, diluition rate. Satisfactory results were obtained with the physical-chemistry pre-treatment in the reduction of COD and TOC, however it generated an unnecessary amount of sludge. The integration activated sludge/Reagent Fenton was shown quite appropriate, mainly in the removal of the color and turbidity; the variety and frequency of the microorganisms observed during the biological monitorament were suitable with the systems of activated sludge operating efficiently and the use of zeolites as support was shown significant, reaching 63,3 % of immobilization of the microorganism in the support.

Page generated in 0.0596 seconds