Spelling suggestions: "subject:"biocapteurs."" "subject:"biocapteur.""
11 |
Apport du forceps instrumenté dans la sécurité de l'extraction instrumentaleDupuis, Olivier Dittmar, André January 2006 (has links)
Thèse doctorat : Images et Systèmes : Villeurbanne, INSA : 2005. / Titre provenant de l'écran-titre. Bibliogr. p. 225-234.
|
12 |
Elaboration et caractérisations de nouvelles membranes enzymatiques pour l'application "biocapteur" en hémodialyse rénaleBarhoumi, Houcine Martelet, Claude. January 2006 (has links) (PDF)
Thèse de doctorat : sciences. Chimie : Ecully, Ecole centrale de Lyon : 2006. Thèse de doctorat : sciences. Chimie : Faculté des sciences de Monastir : 2006. / 338 réf.
|
13 |
Elaboration et caractérisations de nouvelles membranes enzymatiques pour l'application "biocapteur" en hémodialyse rénaleBarhoumi, Houcine Martelet, Claude. January 2006 (has links) (PDF)
Thèse de doctorat : sciences. Chimie : Ecully, Ecole centrale de Lyon : 2006. Thèse de doctorat : sciences. Chimie : Faculté des sciences de Monastir : 2006. / Titre provenant de l'écran-titre. 338 réf.
|
14 |
Conception et réalisation de matériaux biofonctionnels pour des dispositifs capteurs impédimétriquesHelali, Saloua Martelet, Claude. January 2005 (has links) (PDF)
Thèse de doctorat : sciences. Physique quantique : Ecully, Ecole centrale de Lyon : 2005. / 118 réf.
|
15 |
Etude et caractérisation de biocapteurs bactériens luminescents pour la détection de molécules et de microorganismesBendriaa, Loubna Daniel, Philippe January 2005 (has links) (PDF)
Reproduction de : Thèse de doctorat : Physique : Le Mans : 2005. / Titre provenant de l'écran-titre. Bibliogr. p. 133-135.
|
16 |
Irradiations localisées pour des greffages convalents sur supportsEvenou, Fanny Carré, Marie-Christiane January 2006 (has links) (PDF)
Thèse de doctorat : Génie des procédés et des produits : INPL : 2006. / Titre provenant de l'écran-titre. Bibliogr.
|
17 |
Détection électronique d'une interaction biomoléculaire entre des électrodes nanostructuréesHaguet, Vincent. Stievenard, Didier January 2002 (has links) (PDF)
Thèse de doctorat : Sciences des matériaux : Lille 1 : 2002. / N° d'ordre (Lille) : 3216. Résumé en français et en anglais. Bibliogr. en fin de chapitres.
|
18 |
Design and implementation of microelectronic sensor to measure microorganism's growth in diverse environmentsHosseini, Seyedeh Nazila 13 December 2023 (has links)
Titre de l'écran-titre (visionné le 15 mai 2023) / Cette recherche est financée par le programme CREATE du SMAART-CRSNG et la stratégie Sentinelle Nord de l'Université Laval. Ce projet vise à mettre au point un prototype de biocapteur multi détection utilisé pour surveiller la croissance des bactéries ainsi que les paramètres de croissance de leur environnement, notamment le pH et la température, dans divers environnements et dans des endroits éloignés comme le Grand-Nord canadien. La mesure de l'activité des micro-organismes, comme les bactéries, à très basse température peut être extrêmement difficile en raison de leur faible métabolisme et de leur taux de croissance beaucoup plus lent. En effet, la surveillance de leurs fonctions nécessite des outils de haute précision. En outre, lorsque la température ou le pH du milieu de croissance dépasse la plage optimale, la croissance du micro-organisme est entravée. Par conséquent, il est essentiel de surveiller les paramètres environnementaux et les facteurs écologiques, tels que le pH et la température, car ils ont un impact direct sur la croissance bactérienne. Un autre élément essentiel pour améliorer la sensibilité des mesures est la conception et le dimensionnement optimaux des électrodes de détection. La réduction de la taille des électrodes de détection peut permettre une détection à haut débit dans les applications microbiologiques, et permettre des mesures avec un échantillonnage de volume minuscule. Enfin, un système à micro-échelle léger et peu coûteux permet un transport facile dans les régions éloignées. Nous avons donc conçu et fabriqué un nouveau biocapteur multimodal de haute précision, de faible puissance et de poids léger, afin de mesurer la croissance les colonies de bactéries sur le terrain, tout en relevant tous les défis critiques mentionnés ci-dessus. Comme première contribution, pour augmenter la sensibilité des mesures, non seulement le matériau des électrodes mais aussi leur mise à l'échelle et leur miniaturisation sont abordés et évalués. Le prototype utilise plusieurs électrodes à l'échelle microscopique intégrées dans une seule zone de détection pour mesurer avec précision les changements d'impédance, de pH et de température ambiante causés par les activités microbiennes. Cette conception unique comprend des électrodes interdigitées plaquées or (AuIDE), des électrodes de pH à base d'oxyde d'iridium (IrO₂) et des électrodes de détecteur de résistance-température (RTD) en or en forme de serpent sur une seule zone de détection. Plusieurs géométries d'électrodes sont conçues et mises en œuvre de manière optimale sur un circuit imprimé flexible standard, et sont comparées pour évaluer l'effet d'une zone de détection donnée sur la sensibilité du biocapteur à l'aide de diverses techniques de mesure et de circuits personnalisés. Le circuit imprimé de l'électrode est connecté à un circuit imprimé personnalisé contenant les circuits de détection pour la mesure de l'impédance, du pH et de la température. Dans la deuxième contribution, pour une détection d'impédance entièrement intégrée, un amplificateur à verrouillage CMOS (LIA) personnalisé est conçu et fabriqué dans une technologie CMOS de 0,18 µm pour surveiller la croissance bactérienne dans divers environnements à l'aide d'une technique de mesure d'impédance multifréquence. En termes de conception de circuit, un nouvel amplificateur de transimpédance capacitif (CTIA) entièrement différentiel, à faible bruit, avec Chopper stabilisation et S/H dans l'étage de sortie pour maximiser le SNR, est inclus dans la conception LIA proposée. Les autres composants principaux du LIA sont un filtre passe-bande avec des fréquences centrales sélectionnables de 1, 2, 4 et 10 kHz, un amplificateur de gain programmable (PGA) qui offre six gains variables allant de 6 dB à 67 dB pour ajuster le gain dans une plage raisonnable pour détecter le signal d'entrée sans saturer le système, un mélangeur, et un filtre passe-bas avec une largeur de bande de 40 Hz. La sensibilité globale du LIA est de 240 mV/nA avec un courant détectable minimal de 1 pA, un bruit référencé à l'entrée de 58 pA/Hz et une consommation d'énergie totale de 817,56 µW. Comparé à d'autres solutions de la littérature, ce nouveau système donne un dispositif très précis, à faible bruit et à faible consommation d'énergie pour surveiller l'activité microbienne à de faibles concentrations en mesurant l'impédance résultant des métabolites ioniques libérés. Pour relever le troisième défi critique, les circuits de lecture des capteurs de pH et de température sont fabriqués à l'aide de composants disponibles dans le commerce. Un circuit de mesure du pH est conçu en utilisant un amplificateur opérationnel avec un courant de polarisation d'entrée très faible. De plus, un circuit en pont de Wheatstone avec un réseau de résistances est conçu pour mesurer la température en se reliant à l'électrode de température RTD comme une valeur de résistance inconnue. Le microcontrôleur 8 bits reçoit le signal filtré, amplifié et numérise et traite les données du capteur. Le prototype a été utilisé avec succès pour effectuer des mesures de croissance bactérienne in vitro. Dans l'ensemble, il s'agit du premier système qui fournit un biocapteur multimodal de haute précision, à faible consommation d'énergie, à faible coût, à faible bruit, léger et non invasif pour la surveillance de la culture bactérienne. Ce système peut faire des mesures dans un très petit volume grâce à un microsystème de mesure d'impédance intégré. Ainsi, il peut être utilisé pour la surveillance des paramètres environnementaux, y compris le pH et la température, en utilisant des électrodes et des capteurs de haute précision conçus et fabriqués de manière optimale. / This research is funded by the SMAART-NSERC CREATE Program and the Sentinel North Strategy at Université Laval. This project aimed to develop a multi-sensing biosensor prototype used for monitoring bacterial growth as well as their environmental growth parameters, including pH and temperature, in diverse environments and remote locations such as Canada's north. Measuring the activity of microorganisms, such as bacteria, at very low temperatures can be extremely challenging due to their low metabolism and much slower growth rate. Indeed, monitoring their functions requires high-precision tools. Furthermore, when the temperature or pH of the growth medium goes beyond the optimal range, the microorganism's growth is hindered. As a result, monitoring the environmental parameters and ecological factors, such as pH and temperature, is critical because they directly impact bacterial growth. Another critical component for improving measurement sensitivity is the optimal design and scaling of sensing electrodes. Sensing electrode downsizing can enable high-throughput sensing in microbiology applications, and enable measurements with tiny volume sampling. Finally, a light-weight and inexpensive microscale system would allow easy transportation in remote areas. We, therefore, designed and fabricated a novel multimodal high-precision, low-power, and light-weight biosensor to interface with bacteria colonies while addressing all the critical challenges mentioned above. As the first contribution, to increase the sensitivity of measurements, not only the material of the electrodes but also their scaling and miniaturization are addressed and evaluated. The prototype uses multiple microscale electrodes integrated into a single sensing area to precisely measure impedance, pH, and ambient temperature changes caused by microbial activities. This unique design includes the optimally designed gold-plated interdigitated electrodes (AuIDEs), Iridium oxide (IrO₂)-based pH electrodes, and the snaked-shape gold resistance-temperature detector (RTD) electrodes on a single sensing area. Multiple electrode geometries are optimally designed and implemented on a standard flexible PCB and are compared to evaluate the effect of a given sensing area on the sensitivity of the biosensor employing various measurement techniques and customized circuits. The electrode's PCB is connected to a custom-designed PCB containing the sensing circuits for impedance, pH, and temperature measurement. As the second contribution, for fully integrated impedance sensing, a custom CMOS lock-in amplifier (LIA) is designed and fabricated in a 0.18 µm CMOS technology to perform bacterial growth monitoring in diverse environments using a multi-frequency impedance measurement technique. In terms of circuit design, a novel fully differential, low-noise capacitive transimpedance amplifier (CTIA) with chopper stabilization and S/H in the output stage to maximize SNR is included in the proposed LIA design. The other major components of the LIA are a band-pass filter with selectable center frequencies of 1, 2, 4, and 10 kHz, a programmable gain amplifier (PGA) that offers six variable gains ranging from 6 dB to 67 dB to adjust the gain within a reasonable range to detect the input signal without saturating the system, a mixer, and a low-pass filter with a bandwidth of 40 Hz. The overall sensitivity of the LIA is 240 mV/nA with a minimum detectable current of 1 pA, input-referred noise of 58 pA/Hz, and a total power consumption of 817.56 µW. Compared to other solutions in the literature, this novel system results in a highly precise, low-noise, and low-power consumption device for monitoring microbial activity at low concentrations by measuring the impedance as a result of released ionic metabolites. To address the third critical challenge, the reading circuits of the pH and temperature sensors are fabricated using off-the-shelf components. A pH measuring circuit is designed using an operational amplifier with a very low input-bias-current. Furthermore, a Wheatstone bridge circuit with a network of resistors is designed to measure temperature by linking to the RTD temperature electrode as an unknown resistor value. The 12-bit microcontroller receives the filtered and boosted signal and digitizes and processes the sensor's data. The prototype was successfully used to perform bacterial growth measurements in vitro. Overall, this is the novel system that provides a high-precision, low-power consumption, low-cost, low-noise, lightweight, and non-invasive multimodal biosensor for bacterial culture monitoring at very small volume through a custom integrated impedance measurement microsystem, as well as environmental parameter monitoring, including pH and temperature, employing optimally designed and fabricated electrodes and high-precision sensors.
|
19 |
Portable impedance-sensing device for microparticle characterizationBouzid, Karim 13 December 2023 (has links)
À ce jour, quelques biocapteurs ont été proposés pour mesurer rapidement et facilement les caractéristiques et les propriétés des microrganismes individuels membres d'une population hétérogène, mais aucune de ces approches ne s'est avérée être adéquate pour effectuer des mesures directement sur le terrain. Les biocapteurs pour les organismes microscopiques nécessitent généralement une sensibilité ou une spécificité extrême, qui sont difficiles à combiner avec un dispositif général portatif. Cette étude propose un dispositif portatif basé sur la cytométrie de flux d'impédance qui peut détecter et quantifier le diamètre de microbilles de tailles supérieure à 50 µm directement sur le terrain, tout en présentant un faible coût, une taille réduite, une basse consommation de puissance, et une simplicité de conception et d'opération qui maximise le potentiel de l'impression 3D et de la fabrication industrielle de circuits imprimés. Un exemple est offert afin de démontrer les capacités du capteurs pour de larges échantillons, avec un jeu de données contenant 2380 microbilles détectées de tailles entre 50 µm et 90 µm. / To this day, a couple of biosensors have been proposed to quickly and easily measure the features and properties of individual microorganisms member of an heterogeneous population, but none of these approaches were adequate candidates to perform measurements directly in the field. Biosensors for micron-scale organisms generally require extreme sensitivity or specificity, which are difficult to combine with a portable general device. This study proposes a portable device based on Impedance Flow-Cytometry that can detect and quantify directly in the fields the size and velocity of microbeads of size bigger than 50 µm, while boasting a low cost, low size, low power, and simplicity of design and operation utilizing the potential of 3D-printing and industrial PCB fabrication. An example is provided for a Big Data application from a sampled dataset containing 2380 successfully detected microbeads of sizes between 50 µm and 90 µm.
|
20 |
Développement de nanosondes ultraluminescentes pour la détection de métabolites du microbiote intestinalFontaine, Nicolas 13 December 2023 (has links)
Une augmentation de la prévalence des maladies cardiométaboliques (CMD) et mentales est observée au sein des populations autochtones du Nord du Canada. Le passage d'une alimentation traditionnelle à une diète de type occidental pourrait être responsable d'une déstabilisation du microbiote intestinal, un ensemble de microorganismes participants à des processus physiologiques clé incluant la régulation du système immunitaire. Le suivi de l'évolution de biomarqueurs du tractus gastrointestinal en temps réel et de manière longitudinale permettrait de supporter l'élucidation des liens entre les habitudes alimentaires de l'hôte et sa diète. Cependant, cela est entravé par les méthodes d'analyse classiques relativement longues qui reposent sur le prélèvement d'échantillons sanguins ou de fèces, acheminés ensuite vers des laboratoires spécialisés. L'objectif général de ce projet consiste à développer une sonde permettant l'analyse des processus microbiens du tractus gastrointestinal en temps réel en se basant sur l'utilisation d'une fibre optique fonctionnalisée avec des nanoparticules fluorescentes. Dans le cadre de ce projet de thèse, nous avons démontré la possibilité d'utiliser l'agrégation de fluorophores avec des nanoparticules plasmoniques pour la détection d'acides lysophosphatidiques (LPA), des métabolites d'intérêt étant donné leur implication dans de nombreux processus, incluant la signalisation cellulaire, et dont une dysbiose est reliée à certains cancers. Tout d'abord, des sondes possédant une portion styrylpyridinium à titre de tête fluorescente ont été synthétisées afin d'optimiser l'interaction complémentaire avec les LPA tout en permettant leur immobilisation sur des particules plasmoniques. Une architecture cœur-coquille a été produite en combinant la croissance de germes pour l'obtention de particules d'argent, suivie d'un procédé Stöber modifié pour y déposer une fine coquille de silice d'épaisseur contrôlée. Leur fonctionnalisation avec les sondes moléculaires a été réalisée par l'utilisation de silanes afin de leur conférer une exaltation de fluorescence en plus d'une meilleure photostabilité. Dans le cas des sondes moléculaires, l'ajout de LPA cause une extinction de fluorescence pour de faibles concentrations d'analyte, mais une augmentation subséquente du signal pour des quantités plus élevées. Des analyses mécanistiques, incluant le titrage à calorimétrie isotherme de même que des analyses de temps de vie de fluorescence, ont permis d'investiguer le mécanisme de détection, en particulier la formation d'excimères. Dans le cas des suspensions colloïdales, c'est plutôt une amplification de signal qui est obtenue. Une caractérisation par suivi de nanoparticules a montré une agrégation des particules lors de l'ajout de LPA, indiquant une contribution potentielle du couplage plasmonique sur la tendance obtenue. Les perspectives du projet sont surtout reliées à l'immobilisation des particules fluorescentes sur une lamelle de microscopie ou même l'extrémité d'une fibre optique à titre de cathéter afin d'étudier l'impact de ce confinement sur les performances analytiques. La méthode d'analyse sera ensuite validée dans le but d'obtenir les concentrations métaboliques résolues spatialement et dans le temps. / Cardiometabolic disorders (CMD) and mental illnesses are increasingly prevalent pathologies found among indigenous populations of the northern Canada. Ongoing changes in their nutrition from country food to a western-type diet could give rise to a dysregulation of their gut microbiota, i.e., micro-organisms ongoing key physiological processes such as immune system regulation. Monitoring the longitudinal evolution of gut biomarkers in real-time would help decipher the links between the hosts diet and health. However, this is currently hampered by classical a posteriori analysis of fecal or gut samples. The overarching goal of the project is to develop an optical nanoprobe to monitor microbial processes in the gastrointestinal tract based on the use of an optical fiber functionalized with luminescent nanoparticles. During my thesis, we have demonstrated the possibility to use aggregation-based fluorescent transduction with the combination of plasmonic nanoparticles for lysophosphatidic acid (LPA) detection. LPA constitute targets of significant interest since they are involved in several processes, including cellular signalization, and of which a dysbiosis is related to several cancers. To begin with, molecular probes composed of a styrylpyridinium fluorescent head followed by a hydrophobic chain were synthesized to optimize the complementarity of interactions with LPA and allowing for their further immobilization on plasmonic nanoparticles. A core-shell nanoarchitecture was obtained by combining a seed-growth method for the silver nanoparticles core with a modified Stöber process to generate a silica shell of controlled thickness. Their surface functionalization with the fluorescent probe was achieved through the use of silane chemistry to bestow them with enhanced fluorescence intensity and photostability. In the case of the free molecular probes, adding LPA to the medium induces fluorescence quenching for small target concentrations, whereas a subsequent fluorescence enhancement is observed at higher LPA concentrations. Mechanistic investigations involving isothermal titration calorimetry and time-resolved fluorescence spectroscopy provided information on the potential transduction mechanism which would be related to the formation of excimers of the dyes. In the case of colloidal suspensions, a signal enhancement is obtained during titration with LPA. Nanoparticle tracking analysis revealed an aggregation of the nanoparticles when they interact with LPA, suggesting that plasmonic coupling is one of the contributions to the overall trend; the other mechanism would come from the local environment change at the surface of the particles. For the future works of the project, the fluorescent plasmonic nanoparticles will be immobilized on a glass substrate (microscope glass slide or optical fiber) to determine the impact of this constraint on the analytical performances of the sensor. The analytical method will further be validated in complex matrices to allow real-time and spatially-resolved measurements of gut metabolites in vivo.
|
Page generated in 0.0269 seconds