Spelling suggestions: "subject:"bioelectrical impedance analysis"" "subject:"mioelectrical impedance analysis""
1 |
BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
|
2 |
BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
|
3 |
BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
|
4 |
BIOELECTRICAL IMPEDANCE ANALYSIS OF MUSCLE FUNCTION AND ACTIVITY: (BIODYNAMIC ANALYSIS)William Mccullagh Unknown Date (has links)
Abstract There is a need in medicine and research for noninvasive, painless, safe and simple bed-side techniques to measure physiological processes associated with muscle function and activity. Bioelectrical Impedance Analysis (BIA) is a widely used, noninvasive, painless, safe and simple procedure for the measurement of body composition. However, although capable of producing accurate and reproducible data, it is known to be prone to movement artifacts. This poses the interesting question “Could impedance changes be used to monitor movement and, consequently, be related to muscle function or activity?” This project investigated the utility of impedance change as a monitoring technique for physiological processes that involve movement such as muscular contraction, the calf muscle pump, and swallowing. The impedance of leg muscle segments during locomotion, whilst riding a stationary exercise cycle, was measured at discrete frequencies and by bioimpedance spectroscopy to monitor muscle function or activity. Impedance traces were compared to information obtained by electromyography (EMG). Impedance, at a discrete frequency, was able to measure the cadence of cycling and its magnitude was related to the position of the pedal during the pedal cycle. When the cycling action was measured by bioimpedance spectroscopy, R0 and Zc showed a statistically significant difference, (p<0.05), between all angles of the pedal crank cycle while R∞ showed a statistically significant difference between angles in the lower hemisphere of the pedal crank cycle. The cyclical changes in impedance during cycling may be attributed to changes in shape and volume of the muscle during contraction as well as a volume change due to blood and lymph being pumped from the limb by the action of the calf muscle pump. Based on procedures used in the cycling studies, an impedance-based method for the measurement of calf muscle pump function during an exercise protocol, originally designed for use with air plethysmography, was developed. It was shown that impedance measured at 5 kHz provides a simple, non-invasive method for the measurement of the ejection fraction and ejection volume of the calf muscle pump as well as other haemodynamic variables. The impedance-based method was less technically challenging than accepted volumetric methods, such as air plethysmography and strain gauge plethysmography, and non-invasive c.f. ambulatory venous pressure, enabling it to be used repeatedly. Muscle function and activity is not confined to the legs so impedance changes in the arm and forearm during exercise were measured. Impedance measurements, at discrete frequencies and using bioimpedance spectroscopy, of the forearm during contractions of the hand were able to distinguish the difference between a ramp and a pulse contraction. When the impedance of the arm and forearm were plotted against the angle of the forearm to the horizontal during a bicep curl, there was an hysteresis effect. Impedance traces of a bicep curl were compared to an EMG trace of the same action. The larynx is a hollow muscular organ situated in the front of the neck above the trachea consisting of a framework of cartilages bound together by muscles and ligaments. The two major functions of the larynx are deglutition and phonation. Dysphagia, which is becoming more prevalent as the population ages, is defined as difficulty in swallowing thin liquids such as water or juices which splash into the trachea because the patient is unable to control the thin liquid bolus. Aspiration pneumonia and dehydration can be prevented by using thickened liquids which allow patients to achieve a safer swallowing response, but it is difficult to assess this response without interfering with the swallowing process. Impedance pharynography (IPG) is a technique using BIA to monitor an impedance waveform of the swallowing process that presents no radiation hazard to the patient, is non-invasive and does not require specialist trained personnel to operate it. Resistance changes across the neck were measured while subjects swallowed solutions of different viscosities. The resistance changes were distinctive and reproducible for each of the solutions of different viscosities which were swallowed. Measuring the function of the larynx by this method could be useful in the diagnosis and treatment of dysphagia. In conclusion, the studies described in this thesis demonstrate the potential usefulness of the measurement of change in impedance as a measure of muscle activity. Impedance-based methods can measure volume changes associated with changes in cross-sectional area of the muscles involved in contraction as well as compartmental fluid changes caused by the force of the contraction on the surrounding tissues including the vasculature. In particular, measuring the ejection fraction and other haemodynamic variables of the calf muscle pump by impedance has the potential to become the method of choice in the future because it is easy to use, inexpensive, non-invasive, safe, and hygenic. Measuring resistance changes across the neck during swallowing yields distinctive waveforms with features corresponding to the physiological phases of the swallowing process as well as identifying distinctive swallowing patterns associated with the different viscosities of liquids swallowed. Function of the larynx and the associated diseases of the larynx will potentially be easier to diagnose and treat with a safe, non-invasive, inexpensive, portable bed-side method of assessment such as BIA.
|
5 |
Anthropometric measurements versus computed tomography for the assessment of metabolic syndrome in the Bellville South mixed ancestry community, South AfricaIsmail, Saaiga January 2017 (has links)
Thesis (MSc (Radiography))--Cape Peninsula University of Technology, 2017. / Background: Metabolic syndrome (MetS) is a clustering of cardiovascular disease (CVD) risk factors which include abdominal obesity, hyperglycaemia, hyper-triglyceridaemia, low HDL-cholesterol and hypertension. This cluster of metabolic deviations is believed to be the primary driver of the double global epidemic of diabetes (DM) and CVD, conditions which account for much of the social and economic global burden of disease. Similar to the global trend, a high prevalence of MetS (62%) and type 2 Diabetes Mellitus (T2DM) (28.2%) has been reported for the South African mixed ancestry population, with CVD risk significantly higher in subjects with DM. The increase in MetS prevalence is driven by the obesity epidemic and anthropometric cut-off values to define MetS for this particular component of the disease has been reported to differ widely between different populations and ethnicities. Currently the waist circumference (WC) cut-off value for MetS diagnosis needs to be determined and validated per ethnic group as opposed to the previously used European derived cut-off values (Alberti et al., 2006; 2009). Validation of the WC cut-off value needs to be against one of the so called gold standards of central obesity measurement, such as Computer Tomography (CT). This technique can measure subcutaneous fat (SAT) and visceral fat (VAT) individually, which is important because VAT has been reported to be associated with MetS and CVD. The current study forms part of a large research group, investigating the prevalence and risk factors for MetS and T2DM in the South African mixed ancestry population.
|
6 |
The use of bioelectrical impedance analysis for estimating the body composition of various fish speciesDuncan, Michael Bennett 15 June 2009 (has links)
The reliable measurement of growth and condition is vital for effective fisheries assessments. Biologists have long attempted to estimate condition for their assessments, but a reliable method to nonlethally estimate body composition is lacking. Proximate analysis is the most dependable and accurate method for estimating internal composition, but it is lethal, time consuming, and expensive. Recent research has shown bioelectrical impedance analysis (BIA) to be an effective method for estimating proximate composition in some fishes. The technique is quick, inexpensive, and, most importantly, nonlethal, which is vital when examining endangered species or cultured fish. My research focused on developing BIA indices for several new species of fish, using those indices to evaluate the body composition of fish in the field, and determining whether water temperature influenced resistance and reactance measurements. I found that BIA accurately estimated the body composition of bluegill Lepomis macrochirus, redear sunfish Lepomis microlophus, brook trout Salvelinus fontinalis, and northern logperch Percina caprodes (r2 ≥ 0.71, p < 0.0001). I also determined that bluegill and redear regressions were not significantly different (P ≥ 0.10) suggesting they can be used interchangeably during future studies. Laboratory studies revealed that water temperature did not significantly influence resistance and reactance measurements of bluegill, redear, and largemouth bass Micropterus salmoides (P ≥ 0.18). These results, along with previous literature, indicate that BIA may be an accurate and reliable assessment tool for fisheries biologists. / Master of Science
|
7 |
Markers of nutritional assessment in children with gastrointestinal illnessesAurangzeb, Brekhna, Women's & Children's Health, Faculty of Medicine, UNSW January 2008 (has links)
Abstract Nutritional status affects every aspect of a child?s health. Thorough nutritional assessment is hampered by the lack of a single comprehensive tool, which can cover all aspects of nutritional assessment. In three distinct studies, this thesis investigated the nutritional status of hospitalised children, children with coeliac disease and children with inflammatory bowel disease. Study 1 The objectives of this study were to assess prevalence of malnutrition and nutritional risk, and define demographic and anthropometric factors associated with nutritional risk among hospitalized children. In this cross sectional study, 157 hospitalised children were assessed for nutritional status using nutritional risk score (NRS) and anthropometric measurements. We found that 4.5%, 8.9%, 15.1% and 10.4% children were wasted, stunted, overweight and obese respectively. However, with the NRS, 47.8% of the children were at high nutritional risk. These children at high risk had lower weight for age (p=0.02), lower BMI percentiles for age (p=0.001) and longer hospitalization (p=0.001) than children at no risk. Study 2 The objectives of this study were to determine nutritional parameters in children with coeliac disease. Twenty-five children with coeliac disease and an equal number of age and gender matched controls were enrolled and anthropometric measurements, BIA and leptin levels were analysed in all. No significant differences were found between the children with coeliac disease and controls in these parameters. BMI percentile correlated with leptin levels in children with coeliac disease. Study 3 The objectives of this study were to determine anthropometric parameters and leptin levels in children with IBD and ascertain if BMI correlates with leptin levels in these children. Thirty children with IBD and 60 age and gender matched controls were enrolled. Anthropometric measurements and leptin levels were analysed and compared with controls. IBD children had significantly low weight for age (p=0.002), BMI percentiles (p=0.001) and leptin levels (p=0.009) compared to controls. There was a correlation between BMI and leptin levels in IBD children. In conclusion, this thesis has shown that one quarter of hospitalized children were overweight or obese, and further, that half of the hospitalised children were at high risk of nutritional deterioration and these children had longer hospital stay than children at no risk. Children with coeliac disease had similar anthropometric measurements, body compartments and leptin levels to controls. However, children with IBD had lower anthropometric measurements and leptin levels, indicating under-nutrition. Nutritional assessment should be a mandatory part of clinical management with nutritional status assessed by various tools including NRS, anthropometry, BIA and leptin levels.
|
8 |
Physical activity and obesity in children: measurement, associations, and recommendationsDuncan, Scott January 2007 (has links)
Widespread increases in the prevalence of childhood obesity have raised the prospect of serious public health consequences in many countries. New Zealand is no exception; according to the most recent national estimates, approximately one in three children is overweight or obese. As a consequence, an understanding of the specific risk factors that predict this condition in children is becoming increasingly important. It is generally accepted that the promotion of physical activity is a key strategy for reducing the risk of childhood obesity. However, there is limited information describing physical activity and its relationship with body fatness in young New Zealanders. The overall aim of this thesis was to gain insight into the associations between excess fatness and physical activity in New Zealand children from a diverse range of socio-demographic groups. Three related studies were conducted to achieve this aim: a large descriptive survey of obesity and physical activity patterns in primary-aged children, and two preceding studies which develop the methodology for objective assessment of physical activity in this population. The first study provided the only validation data for the NL-2000 multiday memory (MDM) pedometer in children. In a sample of 85 participants aged 5-7 and 9-11 years, the NL-2000 offered similar accuracy and better precision than the widely used SW-200 pedometer (NL-2000: mean bias = -8.5 ± 13.3%; SW-200: mean bias = -8.6 ± 14.7%). The second study investigated reactivity to wearing pedometers over four 24-hour testing periods in 62 children aged 5-11 years. The sample was divided into two groups: one was given a full explanation of the function of the pedometer, while the other received no information prior to testing. The absence of significant differences in step counts between the first and last test periods indicated that there was no evidence of reactivity to this device for either preparation procedure. The central study presented in this thesis was the measurement of physical activity, body composition, and dietary patterns in 1,226 children aged 5-12 years, from which four chapters (4-7) were derived. The sample was ethnically diverse, with 46.8% European, 33.1% Polynesian, 15.9% Asian, and 4.1% from other ethnicities. Physical activity levels over three weekdays and two weekend days were assessed using NL 2000 pedometers. Percentage body fat (%BF) was determined using hand-to-foot bioelectrical impedance analysis with a prediction equation previously developed for New Zealand children. Waist and hip girths, height, and weight were measured using standard anthropometric techniques. Parent proxy questionnaires were used to assess demographic and lifestyle factors and pedometer compliance. The first reported analyses of this dataset (Chapter 4) examined the effect of weather conditions on children’s activity levels. In boys, a 10ºC rise in ambient temperature was associated with a 10.5% increase in weekday steps and a 26.4% increase in weekend steps. Equivalent temperature changes affected girls’ step counts on weekdays only (16.2% increase). Precipitation also had a substantial impact, with decreases in weekday and weekend step counts during moderate rainfall ranging from 8.3% to 16.3% across all sex, age, and socioeconomic (SES) groups. The aim of Chapter 5 was to understand the relationship between children’s step counts and their body mass index (BMI), waist circumference (WC), and %BF. Mean step counts for this sample were 16,133 ± 3,864 (boys) and 14,124 ± 3,286 (girls) on weekdays, and 12,702 ± 5,048 (boys) and 11,158 ± 4,309 (girls) on weekends. Significant associations were detected between steps.day-1 and both WC and %BF, but not between steps.day-1 and BMI. The findings in Chapter 6 extended these results by estimating the number of steps required to reduce the risk of excess adiposity in children (16,000 and 13,000 steps.day-1 for boys and girls, respectively). Finally, the study described in Chapter 7 examined the associations between excess adiposity and a series of demographic and lifestyle variables, providing the first assessment of body fat correlates in young New Zealanders. Our results indicated that children aged 11-12 years were 15.4 times more likely to be overfat (boys, %BF ≥ 25%; girls, %BF ≥ 30%) than those aged 5-6 years. In addition, the odds of overfat were 1.8 times greater in Asian children than in European children, and 2.7 times greater in the low SES group when compared with the high SES group. Three modifiable behaviours related to fat status were also identified: low physical activity, skipping breakfast, and insufficient sleep on weekdays. Clustering of these risk factors resulted in a cumulative increase in the prevalence of overfat.
|
9 |
Use of bioelectrical impedance analysis (BIA) to predict water and energy content of juvenile Rainbow Trout (Oncorhynchus mykiss)Bourdages, Christopher 01 August 2011 (has links)
Accurate measurements of energy content and body composition are essential to effectively assess the well-being of fish. Bomb calorimetry and proximate analysis are currently the most dependable and accurate methods to estimate energy content and body composition. However, bioenergetic studies that employ the traditional methodology necessitate the killing of fish to determine physiological composition and energy content in a target tissue. The killing of the individual negates the ability for repeated measures on the same individual, and also suppresses compositional studies involving endangered or threatened species. Recent research has shown Bioelectrical Impedance Analysis (BIA), a quick, easy-to-use, non-invasive, and most importantly, non lethal technique to be an effective method for estimating the proximate composition and energy content of fish. The focus of this research is to evaluate the capability of BIA to accurately assess the bioenergetics of juvenile rainbow trout (Oncorhynchus mykiss), and to develop species-specific indices to predict energy content, total body water and dry mass. To do this, juvenile rainbow trout were subjected to one of three ration regimes: maintenance (0.4 % bw/day), optimum (1.9 % bw/day) and satiation (3.4 % bw/day) for 90 days. Subsamples from each treatment were taken every 30 days to be subjected to BIA testing. Tissue samples were collected from the subsampled trout for future caloric and compositional analysis via bomb calorimetry and proximate analysis. It was found that BIA demonstrated a strong predictive relationship with regard to energy content (r2 = 0.90), total body water (r2 = 0.89) and dry mass (r2 = 0.80). BIA was also able to successfully reflect a notable statistical difference between treatments with regard to total energy content, energy density, total body water, dry mass. These results, along with much of the existing literature, indicate that BIA may be an accurate and reliable tool to estimate the bioenergetics and proximate composition of fish. / UOIT
|
10 |
Body Mass Index as a Parameter to Evaluate the Prevalence of Hypertension in NH White, NH Black, and Hispanic AmericansNewsome, Shaun 07 August 2012 (has links)
Over the past 30 years, obesity has been primarily identified by the body mass index (BMI). Due to its ease of calculation, the BMI has become the most widely used diagnostic tool to identify weight problems. This study examined the association between hypertension and BMI in White, Black, and Hispanics in the United States. The study’s hypothesis was that this relationship was weaker in Blacks than in the other groups. Data for the study came from the 2007-2008 and 2009-2010 National Health and Nutrition Examination Surveys. The association was weaker in Black men than in Whites or Hispanics on a univariate basis, and at most BMI levels on a multivariate basis. For females, it was also weaker in Blacks at most BMI levels on a univariate basis. However, multivariate logistic regression analysis did not indicate that the hypothesis held for Black women when adding covariates to the models.
|
Page generated in 0.0723 seconds