• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance of Large Diameter Residential Drinking Water Wells - Biofilm Growth: Laboratory and Field Testing

Ruiz Salazar, Hector Fabio 21 November 2011 (has links)
In the first phase of this project three enhanced large diameter (> 60 cm) residential wells were constructed at a study site in Lindsay, Ontario. Two wells were constructed using concrete tile casing while the other well was constructed using galvanized steel casing. Javor (2010) evaluated various aspects of drinking water well construction and design to determine the susceptibility of residential large diameter drinking water wells to surface water and airborne contamination. One of the purposes of these new installations was to remove the uncertainty with respect to construction methods, age and maintenance that is characteristic of residential drinking water well performance studies. Javor (2010) conducted a field and laboratory study to assess the performance of several design changes that were thought to improve the integrity of large diameter drinking water wells. These experiments were also used to determine whether one design was more prone to atmospheric and/or surface water contamination than another. During the second phase of this project routine monitoring was continued and data pertinent to assess the performance of the test wells were collected using the same instrumentation. This routine monitoring involved the visual inspection of the wells, collection of well water elevation, collection of soil temperature profile data, collection and analysis of water samples, and collection of cumulative water volumes extracted from the test wells. In addition to the routine monitoring, a ground penetrating radar (GPR) survey was performed in October 2010 to complement the previous data collected during February 2010. Smoke tracer tests were performed under non-frozen and frozen conditions to re-assess the potential pathways of contaminants between the atmosphere and the interior of the test wells. Bacteriological indicators and high concentrations of two dissolved ions were detected in all test and monitoring wells. The smoke tracer tests demonstrated that pathways for airborne contaminants to enter the test wells exist with similar pathways observed in the winter and the summer. GPR surveys indicated that the bentonite slurry annular sealant was the most homogeneous media. A baseline characterization of the microbial nature of the biofilm performed in three of the test wells (CTH1, ETH1 and ETH3) indicated that the sessile bacteria are more metabolically diverse than suspended bacteria, and that this diversity is even higher in the concrete cased wells. Biofilm characterization performed on concrete, fibreglass and galvanized steel coupons incubated in two of the test wells (concrete and galvanized steel) showed that bacteria in the concrete cased wells barely colonized on fiberglass and galvanized steel, while bacteria in the galvanized steel cased well did not have difficulty colonizing on any of the casing materials. The results of the biofilm cleaning study indicated that the use of pressure washing combined with chlorination effectively removed biofilm grown on galvanized steel and fibreglass casing materials. This study investigated various factors that could affect the performance of large diameter drinking water wells. Since the test wells used in this study were under the direct influence of surface water a comparison between the various annular sealants was problematic. However, the three enhanced test wells outperformed the conventional test well. The observations from the smoke tracer tests performed under non-frozen and frozen conditions indicate that the Poly-Lok lid seam is the most prevalent pathway for airborne contaminants to enter a well. Fibreglass may be the preferred choice for large diameter well casing material since fibreglass is corrosion resistant, lightweight, easy to install, has a high strength to weight ratio, and a greater degree of biofilm was able to be removed from fibreglass casing material than from galvanized steel casing material.
2

Design and Development of an Anti-fouling Urinary Catheter Utilizing Active Surface Deformation

Levering, Vrad Wilson 1 January 2015 (has links)
<p>There are over 30 million Foley urinary catheters used annually, and the greatest problem with Foley catheters is catheter-associated urinary tract infections (CAUTIs). CAUTIs are the number one cause of hospital-acquired infections and make up to 40% of nosocomial infections. Biofilms on urinary catheters are critical to the progression of symptomatic CAUTIs, but are difficult to treat due to the protective effect of the biofilm matrix against antibiotics. The anti-fouling catheter technology proposed and demonstrated herein uses a mechanical, non-antibiotic approach to physically remove biofilms and thereby provide an appealing option for potentially stopping the progression of symptomatic infections. Additionally, because the anti-fouling technology is mechanical, it can circumvent the persistent failings of chemical and biological approaches that have failed to address catheter-associated urinary tract infections for the last 50+ years since Foley catheters were introduced. </p><p>We designed and optimized urinary catheter prototypes capable of on-demand removal of biofilms from the previously-inaccessible main drainage lumen of catheters. The concept uses pressure-actuated chambers in elastomer constructs to generate regio-selective strain and thereby remove biofilms. We first grew mature Proteus mirabilis crystalline biofilms on flat silicone elastomer substrates, and showed that application of strain to the substrate debonded the biofilm, and that increasing the strain rate increased biofilm detachment. A quantitative relationship between the applied strain rate and biofilm debonding was found through an analysis of the biofilm segment length and the calculated driving force for debonding. We then constructed proof-of-concept prototypes of sections of anti-fouling catheter shafts using silicone and 3D printed reverse molding in methods akin to those used for soft robotics. The proof-of-concept prototypes demonstrated release of mature P. mirabilis crystalline biofilms from their strained surfaces, and prompted our development of more advanced multi-lumen prototypes. The multi-lumen prototypes were designed and optimized using successive rounds of finite element modeling to adjust the number and postion of intra-wall inflation lumens. We then constructed prototypes based on the optimized design with clinically relevant dimensions and showed they were able to generate greater than 30% strain on the majority of the luminal surface, and along their full length. Those catheter prototypes were able to on-demand, and repeatedly, remove greater than 80% of a mixed community biofilm of P. mirabilis and E. coli. In summary, this study shows (1) strain in the elastomeric substrate actively debonds crystalline biofilms in vitro (2) modeling based on characterization of biofilm properties and understanding of substrate strain informs and facilitates prototype catheter design (3) urinary catheter prototypes utilizing inflation-induced substrate strain are capable of on-demand and repeatedly removing biofilms in vitro.</p> / Dissertation
3

Performance of Large Diameter Residential Drinking Water Wells - Biofilm Growth: Laboratory and Field Testing

Ruiz Salazar, Hector Fabio 21 November 2011 (has links)
In the first phase of this project three enhanced large diameter (> 60 cm) residential wells were constructed at a study site in Lindsay, Ontario. Two wells were constructed using concrete tile casing while the other well was constructed using galvanized steel casing. Javor (2010) evaluated various aspects of drinking water well construction and design to determine the susceptibility of residential large diameter drinking water wells to surface water and airborne contamination. One of the purposes of these new installations was to remove the uncertainty with respect to construction methods, age and maintenance that is characteristic of residential drinking water well performance studies. Javor (2010) conducted a field and laboratory study to assess the performance of several design changes that were thought to improve the integrity of large diameter drinking water wells. These experiments were also used to determine whether one design was more prone to atmospheric and/or surface water contamination than another. During the second phase of this project routine monitoring was continued and data pertinent to assess the performance of the test wells were collected using the same instrumentation. This routine monitoring involved the visual inspection of the wells, collection of well water elevation, collection of soil temperature profile data, collection and analysis of water samples, and collection of cumulative water volumes extracted from the test wells. In addition to the routine monitoring, a ground penetrating radar (GPR) survey was performed in October 2010 to complement the previous data collected during February 2010. Smoke tracer tests were performed under non-frozen and frozen conditions to re-assess the potential pathways of contaminants between the atmosphere and the interior of the test wells. Bacteriological indicators and high concentrations of two dissolved ions were detected in all test and monitoring wells. The smoke tracer tests demonstrated that pathways for airborne contaminants to enter the test wells exist with similar pathways observed in the winter and the summer. GPR surveys indicated that the bentonite slurry annular sealant was the most homogeneous media. A baseline characterization of the microbial nature of the biofilm performed in three of the test wells (CTH1, ETH1 and ETH3) indicated that the sessile bacteria are more metabolically diverse than suspended bacteria, and that this diversity is even higher in the concrete cased wells. Biofilm characterization performed on concrete, fibreglass and galvanized steel coupons incubated in two of the test wells (concrete and galvanized steel) showed that bacteria in the concrete cased wells barely colonized on fiberglass and galvanized steel, while bacteria in the galvanized steel cased well did not have difficulty colonizing on any of the casing materials. The results of the biofilm cleaning study indicated that the use of pressure washing combined with chlorination effectively removed biofilm grown on galvanized steel and fibreglass casing materials. This study investigated various factors that could affect the performance of large diameter drinking water wells. Since the test wells used in this study were under the direct influence of surface water a comparison between the various annular sealants was problematic. However, the three enhanced test wells outperformed the conventional test well. The observations from the smoke tracer tests performed under non-frozen and frozen conditions indicate that the Poly-Lok lid seam is the most prevalent pathway for airborne contaminants to enter a well. Fibreglass may be the preferred choice for large diameter well casing material since fibreglass is corrosion resistant, lightweight, easy to install, has a high strength to weight ratio, and a greater degree of biofilm was able to be removed from fibreglass casing material than from galvanized steel casing material.

Page generated in 0.0432 seconds