• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ultrafiltração modificada em pacientes submetidos a revascularização cirúrgica do miocárdio = avaliação de parâmetros clinicos e inflamatórios / Modified ultrafiltration in patients undergoing coronary artery bypass grafting : evaluation of clinical and inflammatory

Torina, Anali Galluce, 1981- 16 August 2018 (has links)
Orientador: Orlando Petrucci Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-16T03:58:56Z (GMT). No. of bitstreams: 1 Torina_AnaliGalluce_M.pdf: 3740234 bytes, checksum: f37f64e7d0f1526a0fef521a621823f0 (MD5) Previous issue date: 2010 / Resumo:Introdução: A resposta inflamatória após a circulação extracorpórea (CEC) em cirurgia cardíaca colabora para o aumento de mortalidade e morbidade pós-operatória. A ultrafiltração modificada (UFM) foi descri ta como capaz de melhorar a função pulmonar, hemodinâmica e inflamatória na população pediátrica submetida a cirurgia cardíaca. Entretanto, isto não está bem documentado e definido em pacientes adultos. Objetivo: Avaliar o efeito da ultrafiltração modificada em pacientes adultos submetidos a revascularização cirúrgica do miocárdio sob o aspecto inflamatório e clínico com uso de CEC. Material e Método: Foram estudados 37 pacientes divididos em dois grupos: 17 pacientes no grupo controle e 20 pacientes no grupo UFM. Analisamos variáveis demográficas, hemodinâmicas, pulmonares e mediadores inflamatórios na indução anestésica, durante a operação e até 48 horas de pós-operatório em ambos os grupos. Resultados: Não houve diferença significativa entre os dois grupos quanto aos dados demográficos e nas variáveis hemodinâmicas estudadas. Observamos aumento do hematócrito no grupo UFM imediatamente após a ultrafiltração quando comparado com o grupo controle (P<0,05), contudo, esta diferença não se manteve até o final do período de observação. A resistência das vias aéreas diminuiu no grupo UFM durante o intraoperatório. Observamos menor sangramento pós-operatório (P<0,01) e menor necessidade de transfusão (P=0,01) no grupo UFM. Não foi observado diferença entre os grupos para a IL6, P-selectina, E-selectina. A I-CAM apresentou aumento no grupo UFM logo após a ultrafiltração (P< 0,01). O receptor do fator de necrose tumoral alfa II (receptor TNF-? II) mostrou elevação dos níveis séricos ao final de 48 horas de observação no grupo UFM. Conclusão: A UFM não demonstrou diferença entre os grupos em relação aos parâmetros hemodinâmicos, respiratórios e inflamatórios estudados. O UFM proporcionou menor sangramento pós-operatório e menor necessidade de transfusão de concentrado de hemáceas. A UFM demonstrou ser segura e sem complicações relacionadas, podendo ser útil para o manejo da volemia intraoperatória / Abstract: Introduction: The systemic inflammatory response after cardiopulmonary bypass in cardiac surgery increases mortality and postoperative morbidity. The modified ultrafiltration (MUF) has been described in children and has been shown improvements on pulmonary function, hemodynamics, and inflammatory response. However, in adults, the same benefits were not well documented. Objective: Assess the inflammatory response and clinical outcomes of the modified ultrafiltration in adults underwent elective coronary artery bypass graft surgery. Material and Methods: Thirty-seven patients were evaluated either into two groups: Control group without MUF (N=17) and MUF group (N=20) submitted to 15 minutes of modified ultrafiltration. The demographics, hemodynamics, pulmonary and inflammatory mediators at the induction of anesthesia, during operation and up to 48 hours postoperatively were evaluated. Results: The demographics data and hemodynamic variables were comparable in both groups. The hematocrit was higher in the MUF group immediately after ultrafiltration when compared the the control group (P <0.05). However, this difference was not steady by the end of the observation period. The airway resistance decreased in the MUF group right after the ultrafiltration. The MUF group showed lower postoperative bleeding (P <0.01) and lower requirements of blood units transfusion (P = 0.01). The IL-6, P-selectin, and Eselectin, were comparable in both groups. The I-CAM showed an increase in the MUF group after ultrafiltration (P <0.01). The tumor necrosis factor receptor II was higher by 48 hours of postoperative time in the MUF group. Conclusion: The MUF showed no differences between groups regarding hemodynamic, respiratory function, and inflammatory mediators. The MUF provided lower postoperative bleeding and lower requirements for red blood cells units transfusion. The MUF showed to be safe and without complications, and might be useful for the fluid management during the cardiac surgeries. We were unable to demonstrate a significant impact of MUF on the outcome of adults after coronary artery bypass grafting surgeries / Mestrado / Pesquisa Experimental / Mestre em Cirurgia
2

Influencia da ultrafiltração na remoção de mediadores inflamatorios durante circulação extracorporea e alterações da função organica monitorada pelo "Sequencial Organ Failure Assessment Score - SOFA" em pacientes submetidos a revascularização do miocar / Inflammatory mediators and sequencial organ failure assessment score - SOFA outcomes after conventional ultrafiltration during circulatory bypass in patients underwent coronary artery bypass graft

Antunes, Nilson 14 August 2018 (has links)
Orientador: Desanka Dragosavac, Luis Alberto Magna / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-14T08:33:07Z (GMT). No. of bitstreams: 1 Antunes_Nilson.pdf: 1392711 bytes, checksum: 89e9cd241a2037104655c013c2724bfc (MD5) Previous issue date: 2009 / Resumo: Objetivo: Investigar a eficácia da ultrafiltração na remoção de mediadores inflamatórios liberados pela circulação extracorpórea e correlacionar ultrafiltração com alterações da função orgânica de acordo com o "Seqüential Organ Failure Assessment Score". Métodos: Quarenta pacientes foram incluídos e randomizados em dois grupos: "sem ultrafiltração" (n=20; Grupo I) e "ultrafiltração" (n=20; Grupo II). Complementos 3 e 4 ativados, interleucina 1beta, 6, 8 e fator de necrose tumoral alfa foram dosados antes da indução anestésica (T1), 5 minutos antes da circulação extracorpórea (T2), no líquido ultrafiltrado (T3), 30 minutos (T4), 6 (T5), 12 (T6), 24 (T7), 36 (T8) e 48 (T9) horas após término da circulação extracorpórea. "Sequential Organ Failure Assessment Score" foi avaliado nos tempos 1, 6 e 9. Significância estatística foi estabelecida com p = 0,05. Resultados: No líquido ultrafiltrado, apenas níveis de fator de necrose tumoral alfa foram detectados. Níveis de complemento 3 ativado, nos tempos 5 e 7, e complemento 4 ativado, nos tempos 5 e 6, foram significativamente elevados no grupo sem ultrafiltração, e níveis de interleucina 6 foram elevados no grupo ultrafiltrado, nos tempos 7 e 8. Interleucina 1beta, 8, fator de necrose tumoral alfa, e "Sequential Organ Failure Assessment Score" não tiveram diferenças significantes entre os grupos. Conclusões: Ultrafiltração retira significativamente fator de necrose tumoral alfa, mas isto não influencia nos níveis séricos desta citocina. Ultrafiltração com o tipo de filtro usado neste estudo não filtra outros mediadores inflamatórios estudados e não diminui a disfunção orgânica no pós-operatório. Deverá ser usada apenas para controle volêmico nos pacientes submetidos à circulação extracorpórea. / Abstract: Objective: To investigate the effectiveness of ultrafiltration in removing inflammatory mediators released by cardiopulmonary bypass and to correlate ultrafiltration with alterations in organic function according to the Sequential Organ Failure Assessment Score. Methods: Forty patients were included and randomized into two groups: "no ultrafiltration" (n=20; Group I) and "ultrafiltration" (n=20; Group II). Activated complement 3 and 4, interleukins 1beta, 6, 8 and tumor necrosis factor alfa were measured prior to anesthesia induction (Time 1), 5 minutes before cardiopulmonary bypass (Time 2), in the ultrafiltrated fluid (Time 3), 30 minutes (Time 4), and 6 (Time 5), 12 (Time 6), 24 (Time 7), 36 (Time 8) and 48 (Time 9) hours following cardiopulmonary bypass. Sequential Organ Failure Assessment Score was evaluated at Time 1, 6 and 9. Statistical significance was established at p = 0.05. Results: In the ultrafiltrated fluid, only tumor necrosis factor alfa levels were detected. Levels of activated complement 3 at Times 5 and 7 and activated complement 4 at Times 5 and 6 were significantly higher in the unfiltered Group, and levels of interleukin 6 were higher in the filtered Group at Times 7 and 8. Interleukins 1beta, 8, tumor necrosis factor alfa, and the Sequential Organ Failure Assessment score were not significantly different between the groups. Conclusions: Ultrafiltration significantly filtered tumor necrosis factor alfa but did not influences serum levels of this cytokine. Ultrafiltration with the type of filter used in this study had no effect in organic dysfunction and should be used only for volemic control in patients undergoing cardiopulmonary bypass. / Universidade Estadual de Campi / Pesquisa Experimental / Doutor em Cirurgia
3

Desenvolvimento de um dispositivo auxiliar para calibração de bombas de roletes utilizadas em circulação extracorpórea / Development of an auxiliary device for calibration of roller pumps used in extracorporeal circulation

Medeiros Júnior, Johannes Dantas de 29 June 2016 (has links)
Orientadores: Eduardo Tavares Costa, Francisco Ubaldo Vieira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T00:09:22Z (GMT). No. of bitstreams: 1 MedeirosJunior_JohannesDantasde_M.pdf: 2215491 bytes, checksum: e35d132e2a61efa2d559a4dba08e356e (MD5) Previous issue date: 2011 / Resumo: Circulação extracorpórea é um processo no qual o sangue circula externamente ao corpo com o intuito de manter a oxigenação e o fluxo do sangue adequados durante a realização de determinados procedimentos cirúrgicos; para realizá-la é utilizado um conjunto de técnicas e equipamentos cuja função é substituir temporariamente o coração e os pulmões. Contudo, a circulação extracorpórea é percebida pelo organismo como um agente agressor e um dos principais parâmetros relacionados aos danos que ela provoca é a hemólise. O uso de bombas propulsoras é um dos causadores de hemólise em procedimentos envolvendo circulação extracorpórea e um dos principais tipos de bombas propulsoras é a bomba de roletes. A hemólise provocada pelo uso de bomba de roletes é devida principalmente ao grau de oclusão utilizado. Há dois métodos geralmente utilizados para calibração da bomba de roletes: o método de velocidade de queda e o método de calibração dinâmica. Nesse trabalho é proposto um dispositivo para auxiliar o perfusionista a ajustar bombas de roletes por um método menos oclusivo, a calibração dinâmica. O dispositivo é baseado em um microcontrolador PIC 18F4523 e é utilizado em conjunto com transdutores de pressão descartáveis normalmente utilizados em procedimentos cirúrgicos. Foram determinadas as curvas características de três transdutores de pressão na faixa de 0 a 1000 mmHg. Os resultados das calibrações realizadas com o protótipo desenvolvido foram comparados com os resultados obtidos com uma placa de aquisição de dados comercial. Dois, dos três transdutores, foram submetidos a testes de fadiga e um foi mantido como referência. Para validação do dispositivo, sendo utilizado para realizar calibração dinâmica, foram testados ajustes em 150, 250, 350, 450 e 500 mmHg. Em cada ajuste foram realizadas 8 medições simultâneas de pressão média de calibração dinâmica com o dispositivo e com uma placa de aquisição de dados comercial. Após a realização de todos os testes, os transdutores foram novamente caracterizados. As curvas características dos três transdutores obtidas na caracterização inicial mostraram igualdade estatística (p > 0,05). Após os testes de fadiga não foram observadas alterações nas respostas dos transdutores de pressão no início e após a realização dos testes, nos mesmos pontos de pressão (p > 0,05). As medidas de pressão de calibração dinâmica realizadas com o protótipo apresentaram igualdade estatística (p > 0,05) para toda a faixa de pressão testada, quando comparados com os respectivos resultados obtidos com a placa de aquisição de dados. Conclui-se que os transdutores utilizados atualmente em procedimentos cirúrgicos podem ser utilizados na calibração dinâmica sem perdas de características e que o dispositivo construído pode ser utilizado em ambiente operatório para ajustes de bombas de roletes pelo método de calibração dinâmica / Abstract: Cardiopulmonary bypass is a procedure in which blood circulates outside the body in order to maintain oxygenation and blood flow conditions during the performance of certain surgical procedures; for this procedure, it is used a set of equipments whose function is to temporarily replace the heart and lungs. However, the cardiopulmonary bypass is perceived by the body as an aggressor agent and one of the main parameters related to the damage it causes is hemolysis. The use of driving pumps is a cause of hemolysis in procedures involving cardiopulmonary bypass and one of the main types of driving pumps is the roller pump. Hemolysis caused by the use of roller pump is mainly due to the degree of roller occlusion used. There are two methods commonly used for adjusting the roller pump: the method of drop rate and the dynamic calibration method. In this work, we developed a device to assist the perfusionist adjust roller pumps by a less occlusive method, the dynamic calibration method. The device is based on a PIC 18F4523 microcontroller and is used in conjunction with disposable pressure transducers commonly used in surgical procedures. We have characterized three pressure transducers in the range of 0 to 1000 mmHg. Calibration results obtained with the prototype were compared with those obtained with a data acquisition board. Two of the three transducers were submitted to fatigue tests and one was kept as a reference. To validate the constructed device, being used to perform dynamic calibration, adjustments were at 150, 250, 350, 450 and 500 mmHg, in each set were performed eight simultaneous measurements of dynamic calibration mean pressure with the device and with a data acquisition board. After all tests were conducted, the transducers were re-characterized. The three characteristic curves obtained in the initial characterization showed statistically equivalence (p > 0.05) among themselves. After the fatigue tests no changes were observed in the responses of pressure transducers in the beginning and in the end of the tests, at the same pressure points (p > 0.05). Measurements of dynamic calibration pressure obtained with the prototype showed statistically equivalence (p > 0.05) throughout the tested pressure range, when compared with the results obtained with the data acquisition board. We conclude that the transducers currently used in surgical procedures may be used for dynamic calibration without losing their characteristics and that the constructed device can be used in surgery to adjust the roller pumps by the dynamic calibration method / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica

Page generated in 0.1283 seconds