• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 31
  • 8
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 70
  • 70
  • 15
  • 10
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Control and awareness of digital blood volume pulse : a comparison of headache and non-headache subjects

Gainer, John. January 1986 (has links)
No description available.
2

A study of changes in the blood volume and in certain blood components during cold adaptation in the rat.

Wang, Shi-fu. January 1973 (has links)
Thesis--M. Phil., University of Hong Kong.
3

Control and awareness of digital blood volume pulse : a comparison of headache and non-headache subjects

Gainer, John. January 1986 (has links)
No description available.
4

A neurogenic component in the capacitance vessel pressure-volume response of the dog

Drees, John Allen January 1972 (has links)
This document only includes an excerpt of the corresponding thesis or dissertation. To request a digital scan of the full text, please contact the Ruth Lilly Medical Library's Interlibrary Loan Department (rlmlill@iu.edu).
5

A study of changes in the blood volume and in certain blood componentsduring cold adaptation in the rat

王士孚, Wang, Shih-fu. January 1973 (has links)
published_or_final_version / Physiology / Master / Master of Philosophy
6

Can Hematocrit Levels at Estrus in Dairy Cows and Sheep Be an Indicator for Pregnancy Success?

Kelany, Khaled Elaraby January 2019 (has links)
Despite the major reproductive advances in the livestock industry, prenatal embryonic loss is still one of the major issues that causes substantial economic loss. While there are many tests available to determine pregnancy soon after maternal recognition of pregnancy, most of the prenatal losses are undetectable because it occurs before then. Based on previous research we hypothesized that increased plasma volume around the time of estrus will increase the survivability of the embryo at early stages of gestation. However, our findings indicate that hematocrit levels are not a consistent measurement in determining successful pregnancies.
7

Blood volume distribution in and bioenergetics of swimming and diving ducks

Heieis, Mark Rudolf Alois January 1987 (has links)
Blood flow distribution during forced and voluntary diving in ducks, and the energetic cost of diving was investigated. It has been suggested that in order for the leg muscles to generate enough power for ducks to dive, blood flow to those tissues must be maintained. A technique to determine blood flow distribution which could be used during voluntary diving was first developed and tested during forced laboratory dives of ducks. This technique was then used to determine the blood flow distribution during voluntary diving. Regional blood flow distribution was visualized by utilizing a radioactive tracer technique (macro aggregated albumin labelled with ⁹⁹ⅿ technetium). The tracer when injected into an animal is trapped and held by capillaries. During forced dives in dabbling (Anas platyrhynchos) and diving (Aythya affinis) ducks the blood flow distribution was found to be restricted to the thoracic and head areas. Whereas during a voluntary dive in A. affinis blood flow distribution was shown to be preferentially directed towards three tissue areas, the heart, brain, and active leg muscles. The work required to dive was determined from the measurement of subsurface drag forces and buoyancy in A. affinis. Subsurface drag increased as a nonlinear function of swimming velocity. At a velocity of 1 m•s⁻¹, the drag force was approximately 1.067 N. The average measured buoyant force of 11 ducks was 0.953 N. The calculated mechanical work done by ducks during a 14.4 s unrestrained dive was 9.34 J. The power output during voluntary was estimated to be 0.751 W (0.0374 ml 0₂•s⁻¹). During diving buoyancy is clearly the dominant force (8.8 J) against which ducks have to work while drag (0.54 J) adds little (~6%) to the energetic cost of diving. / Science, Faculty of / Zoology, Department of / Graduate
8

Optoelectronic Neural Implant Sensors for Cerebral Blood Volume Monitoring

Choi, Christopher Samuel January 2018 (has links)
Nearly 50 million people are afflicted with epilepsy, worldwide. These patients suffer from unprovoked seizures, where neurons in the cerebral cortex under go uncontrolled, hypersynchronous firing of neurons. 30\% of patients with epilepsy do not respond to drug treatments. For these patients, surgical treatment involving the removal or disconnection of brain matter is one of the only alternatives. Such surgical treatments often rely on long-term monitoring of neuronal activity in the brain using subdurally implanted surface electrodes to locate the epileptic focus, but these clinical methods for mapping neuronal activity suffer from low spatial resolutions and poor noise, which can limit the success of surgical treatments where an error of even 1 mm can be critical. The work described here involves the development of an implantable system for performing optical recordings of intrinsic signal (ORIS) on the surface of the brain. By taking advantage of the unique absorption spectrum of hemoglobin, cerebral blood volume (CBV) can be measured via reflectivity changes in the brain at at specific wavelengths of light. Due to the metabolic demands of the brain, the exaggerated neuronal activity and spiking associated with epileptic seizures can be detected indirectly through changes in CBV. While high resolution ORIS measurements have been recorded using externally mounted CCD sensors, this work presents some of the first developments in producing a fully implantable ORIS sensor. Progress in the development of an implantable ORIS sensor described here includes: an implantable organic light emitting diode (OLED) and organic photodetector (OPD) integrated on a highly flexible parylene-c substrate, an implantable sensor using a microLED array embedded on a flexible polyimide substrate, and the application of quantum dots to microLEDs for optical down-conversion. Successful in vivo detection of seizures is achieved with high signal-to-noise using these methods. Additionally, spatial localization of seizure activity is performed using the microLED array. These developments represent crucial first steps in the development of a full 2D neuronal mapping system using implantable ORIS devices.
9

The contribution of the lymph hearts in compensation for acute hypovolemic stress in the toad Bufo marinus

Baustian, Mark 01 January 1986 (has links)
Currently published data on the role of the lymphatic system in amphibians are inadequate and contradictory. Estimates of the rate of formation of lymph and the role of the lymph hearts in returning this fluid to the circulation are not based on actual volume determinations but rather estimates derived from changes in hematocrit using published values of plasma and blood volume. The lymph hearts are known to be vital to the maintenance of normal fluid compartment physiology and to increase their rate of activity during episodes of hypovolemic stress. Yet, significant redistribution of body fluids following hemorrage appears to occur in animals without lymph hearts. In this study, plasma and blood volumes were determined by the dye dilution technique using injected Evan's blue dye to label the plasma. Eight intact and 6 animals with their lymph hearts destroyed were hemorrhaged to 78% and 75% of their initial blood volumes, respectively. Changes in blood volume were measured following the hemorrhage by analysis of Evan's blue washout and hemodilution.
10

Admittance measurement for early detection of congestive heart failure

Porterfield, John Edward 02 August 2011 (has links)
Impedance has been used as a tool for cardiac research since the early 1940’s. Recently there have been many advances in this field in the diagnosis of human heart failure through the measurement of pacemaker and ICD coupled impedance detection to determine the state of pulmonary edema in patients through drops in lung impedance. These new detection methods are far downstream of the initial changes in physiology, which signify heart failure risk, namely, an increased left ventricular (LV) end-diastolic volume (also known as preload). This dissertation presents the first formal validation of the complex admittance technique for more accurate blood volume measurement in vivo in mice. It aims to determine a new configuration of admittance measurement in a large scale animal model (pigs). It also aims to prove that “piggybacking” an admittance measurement system onto previously implanted AICD and bi-ventricular pacemakers is a feasible and practical measurement that will serve as an early warning system for impending heart failure through the measurement of LV preload, which appears before the currently measured drop in lung impedance using previous techniques. / text

Page generated in 0.0399 seconds