Spelling suggestions: "subject:"blood coagulation tests"" "subject:"flood coagulation tests""
1 |
Screening dental patients for hematologic disordersLaturno, Donald E. January 1975 (has links)
Thesis (M.S)--University of Michigan, 1975. / Typescript (photocopy). Includes bibliographical references (leaves 46-50). Also issued in print.
|
2 |
Screening dental patients for hematologic disordersLaturno, Donald E. January 1975 (has links)
Thesis (M.S)--University of Michigan, 1975. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 46-50).
|
3 |
Ground-glass clotting time for dental patientsGobetti, John Paul. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971. / Typescript (photocopy). Includes bibliographical references (leaves 32-34). Also issued in print.
|
4 |
Ground-glass clotting time for dental patientsGobetti, John Paul. January 1971 (has links)
Thesis (M.S.)--University of Michigan, 1971. / Typescript (photocopy). eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 32-34).
|
5 |
A COMPARISON OF ACTIVATED PARTIAL THROMBOPLASTIN TIME OBTAINED BY TWO TECHNIQUES IN PATIENTS FOLLOWING PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTYHobby, Deanna Jeanne January 1987 (has links)
A descriptive study was conducted to test the null hypothesis: There will be no statistically significant difference between serum activated partial thromboplastin time (aPTT) obtained by two methods; venipuncture and large bore femoral arterial catheter. The convenience sample consisted of seventeen adults who had undergone percutaneous transluminal coronary angioplasty (PTCA) for the treatment of coronary artery disease. After the PTCA procedure, patients returned to an intensive care unit with a femoral intra-arterial catheter in place. Seventeen pairs of serum samples were obtained; one by venipuncture and one through the femoral intra-arterial catheter. Prior to obtaining the sample from the femoral intra-arterial catheter, 6.0 milliliters (3 times the deadspace of the catheter) of blood was withdrawn and discarded. aPTT samples were analyzed. T-tests were used to compare the results. Findings revealed that there was no statistically significant difference in the aPTT value when drawn from venipuncture versus the femoral intra-arterial catheter.
|
6 |
Development of the clot formation and lysis (CloFAL) global assay and its application to the investigation of bleeding disorders in children and adults /Goldenberg, Neil A. January 2008 (has links)
Thesis (Ph.D. in Clinical Science) -- University of Colorado Denver, 2008. / Typescript. Includes bibliographical references (leaves 136-146). Free to UCD Anschutz Medical Campus. Online version available via ProQuest Digital Dissertations;
|
7 |
Pre-coagulation of solid organsDaniel, Steven A., School of Medicine, UNSW January 2007 (has links)
Coagulation has and continues to be one of the most important elements in medicine. Issues from a lack of hemostasis range from poorer clinical outcomes to sudden death. The evolution of treatments for hemostasis have evolved from the use of Tamponade with direct pressure and bandages, the use of materials such as cobwebs and dust, the use of heat with hot oil or heated irons, to the use of suture, glues, plasmas, staplers, and electricity. This evolution has continued to bring about the prophylactic use of technology in an effort to prevent blood loss. This change from reactive treatments to proactive continue to be on a localized or superficial basis. One of the largest opportunities to proactively reduce blood loss in surgical patients is during the resection of solid organs such as the liver, kidney, and spleen. Few options have existed to help improve hemostasis short of the complete occlusion of blood supplying the tissue such as in the Pringle Maneuver. Recent studies have begun to show that practices such as this may have a significant detrimental effect on morbidity. It has been found that by applying radio frequency electrical energy in a particular way that large amounts of tissue can be pre-coagulated prior to resection. A series of animal and human clinical work has been completed to help evolve and confirm the method and the device that was created and refined during this effort. During the course of this work fifty-three patients were treated at four institutions on three continents. Average blood loss for liver resections performed with this pre-coagulation technique using the developed device in a multicenter control trail was 3.35 ml/cm2 as compared to 6.09 ml/cm2 (p < 0.05) for resections performed using standard surgical techniques alone. Additionally, the transection time necessary was also reduced from mean value of 27 minutes (2 -- 219 minutes) to 35 minutes (5 -- 65 minutes). Patients treated included those suffering from liver cirrhosis, fatty liver disease, and post chemotherapy fibrosis. From this work the use of pre-coagulation with methods and device developed was shown to be safe and effective for reducing the amount of blood loss and transection time during liver resections.
|
8 |
Pre-coagulation of solid organsDaniel, Steven A., School of Medicine, UNSW January 2007 (has links)
Coagulation has and continues to be one of the most important elements in medicine. Issues from a lack of hemostasis range from poorer clinical outcomes to sudden death. The evolution of treatments for hemostasis have evolved from the use of Tamponade with direct pressure and bandages, the use of materials such as cobwebs and dust, the use of heat with hot oil or heated irons, to the use of suture, glues, plasmas, staplers, and electricity. This evolution has continued to bring about the prophylactic use of technology in an effort to prevent blood loss. This change from reactive treatments to proactive continue to be on a localized or superficial basis. One of the largest opportunities to proactively reduce blood loss in surgical patients is during the resection of solid organs such as the liver, kidney, and spleen. Few options have existed to help improve hemostasis short of the complete occlusion of blood supplying the tissue such as in the Pringle Maneuver. Recent studies have begun to show that practices such as this may have a significant detrimental effect on morbidity. It has been found that by applying radio frequency electrical energy in a particular way that large amounts of tissue can be pre-coagulated prior to resection. A series of animal and human clinical work has been completed to help evolve and confirm the method and the device that was created and refined during this effort. During the course of this work fifty-three patients were treated at four institutions on three continents. Average blood loss for liver resections performed with this pre-coagulation technique using the developed device in a multicenter control trail was 3.35 ml/cm2 as compared to 6.09 ml/cm2 (p < 0.05) for resections performed using standard surgical techniques alone. Additionally, the transection time necessary was also reduced from mean value of 27 minutes (2 -- 219 minutes) to 35 minutes (5 -- 65 minutes). Patients treated included those suffering from liver cirrhosis, fatty liver disease, and post chemotherapy fibrosis. From this work the use of pre-coagulation with methods and device developed was shown to be safe and effective for reducing the amount of blood loss and transection time during liver resections.
|
9 |
Graphical and Bayesian analysis of unbalanced patient management data /Righter, Emily Stewart, January 2007 (has links) (PDF)
Project (M.S.)--Brigham Young University. Dept. of Statistics, 2007. / Includes bibliographical references (p. 60-61).
|
10 |
Coagulation and inflammation in experimental endotoxemia in vitro and in vivo : monitoring method and effects of nicotinamide /Ungerstedt, Johanna S. , January 2003 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2003. / Härtill 5 uppsatser.
|
Page generated in 0.0909 seconds