• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise biomêcanica de diferentes locais de bloqueio em haste intramedular utilizando corpos de prova com falha crítica /

Malta, Caio Afonso dos Santos January 2020 (has links)
Orientador: Luís Gustavo Gosuen Gonçalves Dias Gosuen / Resumo: O presente trabalho teve como objetivo avaliar biomecanicamente por meio de teste de compressão axial, diferentes posicionamentos e quantidade de bolts em haste intramedular bloqueada de ângulo estável (HIB-AE), em simulação de fratura diafisária irredutível em corpos de prova (CP). Os CPs, produzidos a partir do ácido polilático por impressora 3D, foram projetados e manufaturados com bloco de apoio na extremidade para a preensão na máquina de ensaios. A haste utilizada no experimento apresentava 6 orifícios (denominados de 1 a 6, de proximal para distal), com roscas internas, sendo 3 em cada extremidade (proximal e distal). Um aparato específico (bancada gabarito) foi desenvolvido para total padronização e precisa inserção da haste intramedular e bloqueios nos corpos de prova. Foram usadas 28 amostras divididas em 4 Grupos. No Grupo 1 (G1) a haste foi bloqueada nos orifícios 1 e 6. No Grupo 2 (G2) o bloqueio aconteceu nos orifícios proximais 1 e 2, e nos orifícios distais 5 e 6. Para o Grupo 3 (G3) foram fixados os orifícios 2 e 3 (segmento proximal) e 4 e 5 (segmento distal). Já no Grupo 4 (G4) todos os 6 orifícios foram bloqueados. Os referidos orifícios foram bloqueados utilizando-se bolts especialmente desenvolvidos para esse modelo de HIB-AE. Os testes de compressão axial foram realizados por máquina de ensaios universal a uma velocidade e 5 mm/minuto. Os dados foram avaliados entre os quatro Grupos (G1, G2, G3 e G4), resultando em sete repetições a cada combinação. O t... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present study aims to evaluate biomechanically (axial compression test) different positions and number of bolts locked to a new model of stable-angle intramedullary interlocking nail (ILN) in a simulation of complex diaphyseal fracture in synthetic bone models. The specimens were designed with end support for gripping on testing machines and were manufactured from polylactic acid (PLA) by 3D printer. The interlocking nail used in the experiment was developed with 6 holes (called 1 to 6 from proximal to distal) with internal threads, 3 at each end (proximal and distal). A specific apparatus (template stand) has been developed for full standardization and precise insertion of the interlocking nail and locking in the specimens. Twenty-eight samples were used, divided into four groups. In Group 1 (G1) the ILN was blocked in holes 1 and 6. In Group 2 (G2) the locking occurred in proximal holes 1 and 2, and distal holes 5 and 6. Group 3 (G3) fixed holes 2 and 3 (proximal segment) and 4 and 5 (distal segment). In Group 4 (G4), all 6 holes were locked by specific bolts. Axial compression tests were performed by a universal testing machine at a speed of 5 mm / minute. Data were evaluated between the four groups (G1, G2, G3 and G4), resulting in seven repetitions for each combination. The Shapiro-Wilk test was applied and concluded that the data presented normal distribution (p = 0.070). Among the average loads the highest value was recorded in G4 (9420.34N ± 4081.37N) followed by ... (Complete abstract click electronic access below) / Mestre

Page generated in 0.0772 seconds