Boiler feed pump low load – leak off recirculation studyvan Tonder, Daniël 26 November 2021 (has links)
For power plants that make use of high energy boiler feed pumps, there is a risk that the boiler feed pump may experience cavitation and overheating at low load and start-up conditions. These plants make use of a leak off or recirculation system that diverts some of the flow back to the feed water tank, ensuring that a minimum flow through the pump is maintained at low load and start-up operating conditions. The recirculation valve, also known as a leak off valve, experiences a very high pressure difference and cavitation pitting is common due to the water being close to saturation. There are various ways in which the recirculation flow is controlled in the industry such as open orifice, on/off binary type control valves, automatic recirculation valves (ARC) or modern modulating leak off systems. The valves themselves can also be simple plug type or make use of pressure staging to reduce the risk of cavitation. This project involves modelling the flow system around the boiler feed pump and its control for the various architectures employed in Eskom. This is to assist in understanding the reasons for cavitation damage that is found in some recirculation valves as well as the low load capability of the system. Single stage components with extremely high pressure drops are singled out as components with the highest risk of cavitation in the systems. Although extremely high pressure drops are found across the leak off valves themselves, the majority of the valves are multistage valves which are specifically designed to accommodate cavitation development and are therefore not of major concern. Some of the findings of the study are: The rule of thumb used within Eskom to determine the amount of pressure reducing stages on leak off valves could be more conservative. The specification of new valves and components for the leak off systems requires accurate specification based on detailed process models, such as the ones developed for this study. The full range of all possible operational cases must also be considered during the design.
|
2 |
Low load operation of turbine-driven boiler feed pumpsClark, John Shaun 12 March 2020 (has links)
Boiler feed pump turbines (BFPTs) are in use at a number of Eskom power stations. They utilise bled steam extracted from the main turbine in order to drive multistage centrifugal pumps which supply the boilers with feedwater. With an increase of renewables in the energy mix, the need for Eskom’s coal-fired power stations to run for extended periods at very low loads has arguably never been this great. Various systems affect the ability of these generation units to run economically at low loads. One such system is the boiler feed pump turbine and its associated pumps. A station was selected from Eskom’s fleet based on access to information and the station being a relatively typical plant. The Unit (a boiler and turbogenerator set) selected for study was one with the most thorough instrumentation available for remote monitoring. The BFPT system of this Unit was modelled in Flownex, a one-dimensional thermofluid process modelling package. The model included individual pump stages, steam admission valves and a stage-by-stage turbine model utilising custom stage components. These turbine stage components represent each stage with nozzles and other standard Flownex components. The boundary conditions of the system were set as functions of generator load in order to represent typical values for use in case studies. The relationships between load and boundary conditions were based on large samples of data from the station’s data capture system (DCS). A corresponding standby electric feed pump system was also modelled in Flownex for a comparative case study. After model validation, a number of case studies were performed, demonstrating the functionality of the model and also providing specific results of value to the station in question. These results include the minimum generator load possible with different steam supplies; maximum condenser back pressure before plant availability is affected; the viability of changing the pump leak-off philosophy; and the effect of electric feed pump use on power consumption. The main recommendations from the case studies were as follows: i. to stroke the steam admission valves as per the design charts, ii. to test the operation of the BFPT down to 40 % generator load, iii. to keep the pump leak-off philosophy unchanged, iv. to maintain the cooling water system and condensers sufficiently to avoid poor condenser vacuum, v. to reconsider the decommissioning of the “cold reheat” steam supply, vi. and, to favour use of the BFPT over the electric feed pumps at all generator loads.
|
Page generated in 0.0815 seconds