• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 3
  • 3
  • Tagged with
  • 15
  • 15
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Low-energy block of apartments / Low-energy block of apartments

Reiter, Michal January 2015 (has links)
Diploma thesis is aimed on solution of project documentation design of a four-storey low-energy block of apartments with a flat roof in the degree of project realization. The object has a collective garage on first floor and no basement. The structure is designed with the emphasis on overall energy saving, which was documented by detailed calculation of the energy performance of the building under Decree No.78 / 2013 Coll. and ČSN 73 0540-2.
12

Modélisation dynamique tridimensionnelle avec tache solaire pour la simulation du comportement thermique d’un bâtiment basse consommation / A three dimensional thermal room and sun patch model to simulate the transient behaviour of an energy efficient building

Rodler, Auline 25 November 2014 (has links)
Cette thèse s’inscrit dans le contexte du développement de Bâtiments Basse Consommation. La conception de telles constructions les rend sensibles aux sollicitations internes. Aussi, les outils de thermique du bâtiment existants ne sont pas adaptés pour simuler assez fidèlement ce type de bâtiments, si bien qu’un modèle tridimensionnel et dynamique a été développé ici. Celui-ci présente plusieurs particularités : il s’appuie sur une discrétisation spatiale optimisée des parois, la tache solaire y est localisée et l’intégration des dynamiques des conditions environnementales est assurée par un solveur numérique à pas de temps adaptatif et un seul nœud d’air est considéré. La validation du modèle s’est suivant une confrontation avec des mesures en conditions réelles réalisées dans une cellule de BESTlab d’EDF R&D. Un suivi visuel de la tache solaire a permis de confirmer sa bonne localisation par notre modèle. Des mesures de température en surface complétées par des cartographies thermographiques ont été comparées aux champs de températures simulés, montrant une bonne concordance. Les comparaisons de températures d’air mesurées et simulées ont montré des résidus ne dépassant pas 1,5 ˚C, pour des erreurs moyennes de 0,5 ˚C. La pertinence des deux principales innovations du modèle a été ensuite démontrée : l’utilisation d’entrées échantillonnées à la minute associées à un solveur à pas de temps adaptatif permet de minimiser les erreurs de simulation : en mi-saison, les résidus maximaux sont respectivement de 1 ˚C et 2 ˚C pour des entrées à la minute et à l’heure. En hiver, les températures d’air simulées tendent à plus osciller autour de la consigne quand le pas d’échantillonnage des entrées s’allonge. Deux modèles unidimensionnels, représentatifs de modèles courants, M1D,sol diluant le rayonnement solaire sur le sol seul et M1D,parois le distribuant de façon homogène sur les parois au prorata de la taille de la tache solaire censée les frappées, ne dégradent que légèrement la précision des calculs de température d’air. Cependant, ces modèles 1D ne permettent pas de calcul des champs de températures sur les parois si bien qu’ils présentent des erreurs locales dépassant 20 ˚C aux endroits touchés par la tache solaire. Enfin en hiver, le modèle 3D permet de prédire des consommations de chauffage surestimées de 6,5 % quand M 1D,parois les surestime de 11 % et M1D,sol de 22 %. Les améliorations apportées par notre modèle ont été confirmées pour d’autres types de cellules. D’ailleurs des écarts plus importants entre M1D,sol et le modèle 3D ont été observés pour une cellule dont parois et sol ont des compositions très différentes, alors que l’orientation a aussi un impact. Ce travail confirme la nécessité de représenter plus finement les phénomènes physiques pour des locaux fortement isolés. Des améliorations sont à intégrer, comme la description de l’anisothermie de l’air. / Low energy building constructions become sensitive to internal gains : any internal heating source has an impact on the envelope. Therefore, it is important to evaluate the performance of current transient thermal models when adapted to low energy buildings. This work describes a numerical model to simulate a single room, using a refined spatial three-dimensional description of heat conduction in the envelope but a single air node is considered. The model has been developed for environmental conditions that vary over short time-steps and has integrated the projection of solar radiation through a window onto interior walls : the sun patch. The validation of the model has been done through a detailed comparison between model and measurements. The in situ experiment has been carried out in one of the BESTlab cells (EDF R&D). The sun patch has been followed by a camera to validate its calculated position and surface. Temperature measurements by thermocouples and by thermal cameras have been compared to the models outputs. Differences between air and surface temperatures measured and simulated were never above 1.5 ˚C and mean errors reached 0.5 ˚C. The two innovations of the model have then be proven. Using minute wise weather data and inputs associated to an adaptative solver, enabled to pull down simulation errors : in May maximal differences rised from 1 ˚C to 2 ˚C for respectivelly one minute and hourly wise inputs. More important errors are seen in summer whereas in winter, air temperatures simulated tend to more fluctuate around the set up temperature when the sampling step gets longer. Two one dimensional models, close to traditional taken simulation tools, were used. Model M 1D,sol supposed the incoming radiation to reach only the floor. A 1D model with sun patch movement, called 1D,parois , was also used. These two models evaluated the air temperature with an acceptable error. However, their surface temperatures were still subject to important errors. Thus, for temperature surfaces evaluation, both 1D model presented differences up to 20 ˚C for surfaces touched by the sun patch. In winter, the 3D model can predict heating energy consumptions overestimated by 6.5 % when M 1D,parois overestimated them by 11 % and M1D,sol by 22 %. The improvements brought by our model have been proven also for other cells with different thermal masses. For these cells, differences between M1D,sol and the 3D model could reach 4.5 ˚C. Differences seemed to be more important for low thermal mass cells, and the orientation of the building had a strong impact. This work has confirmed the necessity of representing more accuratelly the descriptions of the enveloppe for strongly insulated rooms. To improve the model, the anisothermal hypotheses of the air should be considered.
13

Contribution à l'étude des échanges convectifs à l'interface fluide paroi en présence de matériaux à changement de phase : Application au bâtiment / Contribution to the study of convective heat transfer at the wall-fluid interface in the presence of phase change materials : Application at the building scale

Bykalyuk, Anna 12 December 2014 (has links)
De récentes études expérimentales ont montré que les valeurs usuelles du coefficient d’échange convectif sont différentes en présence de matériaux à changement de phase. Cette thèse de doctorat porte sur l'étude numérique des échanges convectifs fluide/paroi dans une cavité ouverte en régime dynamique. Plus précisément, les parois étudiées sont une paroi avec une capacité thermique et une paroi qui contient des matériaux à changement de phase. Trois modèles distincts ont été développés. Dans un premier temps un modèle (modèle 1) qui concerne l’interaction fluide-paroi à la surface d’une paroi résistive (temperature imposée) en régime laminaire stationnaire a été développé et validé. Les résultats ont été confrontés avec la littérature. Ensuite, les échanges convectifs à la surface d’une plaque capacitive (modèle 2) soumise à une rampe de température d’air ont été étudiés. Finalement, un troisième modèle (modèle 3) a été développé, à la suite du modèle 2. Ce dernier modèle concerne l’interaction fluide-paroi à la surface d’une paroi contenant des matériaux à changement de phase en régime dynamique. Les résultats obtenus révèlent des pics locaux du flux de chaleur au cours du temps. Ce fait témoigne du changement d’état à l’intérieur de la paroi qui contient le materiau à changement de phase. De plus, les courbes des coefficients d’échanges convectifs moyens révèlent la dépendance du coefficient d’echange convectif à la capacité thermique du materiau. Par conséquent, la présence des matériaux à changement de phase à l’intérieur d'une paroi influence l’évolution et la forme de la couche limite thermique. / Recent experimental studies have shown that the usual values ​​of the convective heat transfer coefficient h are no longer valid in the presence of phase change materials. Three separate models were developed. Initially a model 1 which treats the fluid-wall (constant temperature) interaction in steady laminar flow has been developed and validated. Then, the wall with heat capacity (model 2) subjected to an air temperature ramp were studied. Finally, a third model (3) has been developed which treats the interaction fluid-wall which contains a phase change material. The results show local peaks of heat flow over time. This fact reflects the phase change inside the wall. Moreover, the curves of the convective heat transfer coefficient indicate the dependence of the coefficient h to the wall’s energy storage capacity. Therefore, the presence of the phase change materials within a wall effect and changes the shape of the thermal boundary layer.
14

Polyfunkční dům v Litovli / Multifunctional building in Litovel

Obrátil, Pavel January 2015 (has links)
The diploma thesis was elaborated for as part of design documentation for new multifunctional building in Litovel. The building will be used for purposes of bus and train station, another way for administration purposes. The building contains the second and a third floor with a modern look suitably fits into the surrounding countryside. The significant emphasis was on both nice appearance of the building, so the correct process engineering and dispositional solution. The building is designed so that in terms of design and implementation easily accomplishable. Furthermore, to meet all the requirements for building physics and fire safety. During seminar work was solved problems of summer overheating of the room situated on the south side of the building. For the preparation of project documentation for construction was used CAD software and specialized software for structural calculations of statics and construction.
15

Polyfunkční dům ve Strakonicích / Multifunctional house in Strakonice

Kolesa, Jiří January 2017 (has links)
The subject of this thesis is the design and project documentation of a new multifunctional house in Strakonice. The building has four floors, without basement, and is located on a slightly sloping land in the suburban part of the town of Strakonice. It is based on shallow foundations and covered with a flat roof. It is a transverse wall structural system, build with clay block masonry, with the semi-assembled ceiling structures of ceramic and concrete beams and inserts. It is conceived as a double-aisle layout. The ground floor of each wing consists of the establishment of shops and house facilities. The overground floors are designed as six residential units of varying size category. Both tracts have separate entrances to both the residential portion and to individual businesses. The building is designed from traditional building materials. In addition to the architectural construction and civil-engineering design, a part of this project is also a fire safety design and an assessment from the perspective of building physics.

Page generated in 0.0498 seconds