• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Variação da temperatura no interior da câmara pulpar em função de diferentes fontes de luz e camadas de resina composta. In vitro / In vitro temperature variation inside the pulp chamber regard different light sources and composite layers

Andreatta, Ligia Maria Lima 31 March 2015 (has links)
Este estudo in vitro avaliou a variação da temperatura no interior da câmara pulpar durante a fotoativação do sistema adesivo e incrementos de resina composta em função de diferentes fontes de luz, testando as hipóteses nulas de que estes fatores não interferem na temperatura intra câmara pulpar. Foram selecionados 10 incisivos bovinos, seccionados na região radicular 3 mm além da junção amelocementária. Uma cavidade retangular (10X8mm) foi confeccionada no centro da face vestibular, com espessura padronizada do remanescente dentinário da parede axial em 1 mm. A câmara pulpar foi preenchida com pasta térmica e o sensor termopar tipo K foi introduzido na câmara em contato com o remanescente dentinário. A elevação da temperatura foi aferida durante 40s de fotoativação do sistema adesivo (SBMP) e dos 3 incrementos consecutivos de 1mm de resina composta (Z250), com diferentes fontes de luz. As fontes utilizadas foram: Luz Halógena 755mW/cm2 (Curing Light XL 3000 3M), Luz emitida de diodo (LED) de baixa densidade de potência 400 mW/cm2 (OptiLight LD Max - Gnatus), e LED de alta densidade de potência 1500mW/cm2 (VALO Ultradent). O LED de alta densidade de potência proporcionou os maiores aumentos de temperatura, seguido da luz halógena e do LED de baixa densidade de energia. A polimerização do sistema adesivo seguido do primeiro incremento de resina determinou os maiores aumentos de temperatura. A partir do segundo incremento da resina composta, o material restaurador atuou como isolante térmico reduzindo o aumento de temperatura. Independente da fonte de luz e etapa restauradora, o aumento no tempo de polimerização foi determinante no aumento de temperatura, rejeitando as hipóteses nulas testadas. / This In vitro study evaluated the temperature variation inside the pulp chamber during the curing of the adhesive and composite layers with different light sources, testing the null hypothesis that these factors do not affect the temperature of the intra pulp chamber. Ten bovine incisors were selected and sectioned beyond the root region at 3 mm of the cementoenamel junction. A rectangular cavity (10x8mm) was made in the center of the buccal surface, with the remaining 1mm dentin thickness standardized at the axial wall. The pulp chamber was filled with thermal paste and a type K thermocouple sensor was introduced into the chamber in contact with the remaining dentin. The temperature was measured for 40s during the curing of the adhesive system (SBMP) and 3 consecutive layers of 1mm composite resin (Z250) was applied with three different light sources. The sources used were: Halogen Light 755mW/cm2 (Curing Light XL 3000 - 3M), Light emitted diode (LED) low power density 400 mW/cm2 (Optilight LD Max - Gnatus), and high power density LED 1500mW/cm2 (VALO Ultradent). For all light sources, the temperature readings decreased as the cavity was filled, with statistically significant differences until the second layer of composite resin. The high power density LED showed a significantly higher temperature average (42.78+1.56oC) than the other light sources, and the lowest was the average of the low power density LED (37.81+0.12oC). It could be concluded that both the light source, and the number of layers interfered with the temperature variation, rejecting the null hypotheses tested.
2

Avaliação in vitro da influencia de substancias quimicas auxiliares ao tratamento endodontico na nanoinfiltração, na resistencia de união e coesiva da dentina da camara pulpar / In vitro evaluation of the influence of chemical substances auxiliary to the endodontic treatment on the nanoleakage, bond strengths and cohesive strengths of the pulp chamber dentin

Dametto, Fabio Roberto 23 January 2006 (has links)
Orientador: Caio Cezar Randi Ferraz / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-05T21:19:10Z (GMT). No. of bitstreams: 1 Dametto_FabioRoberto_D.pdf: 5792903 bytes, checksum: e96494d5cbd4bb4a015b8039b5411709 (MD5) Previous issue date: 2006 / Resumo: Grande parte dos insucessos da terapia endodôntica está diretamente relacionada com a ausência ou confecção de uma inadequada restauração, propiciando assim, microinfiltração coronária e recontaminção do sistema de canais radiculares. Desta forma, este trabalho teve como objetivo avaliar a influência de substâncias químicas auxiliares ao tratamento endodôntico na resistência de união de um sistema adesivo à dentina profunda da câmara pulpar. Molares íntegros tiveram as coroas dentais seccionadas transversalmente 3mm acima da junção cemento-esmalte, expondo o assoalho da câmara pulpar. Os dentes foram divididos em 6 grupos e submetidos ao tratamento variando-se as substâncias químicas auxiliares, G1- Soro fisiológico, G2- EDTA 17%, G3- NaOCl 5,25%, G4- NaOCl 5,25% + EDTA 17%, G5- Clorexidina gel 2% e G6- Clorexidina líquida 2%, nas quais os espécimes foram mantidos imersos pelo período de 30 minutos. Posteriormente, 4mm da câmara pulpar foram preenchidos utilizando o sistema adesivo Single BondÒ (3M, St. Paul, MN, USA) e a resina composta Z250Ò cor B2 (3M, St. Paul, MN, USA). Vinte dentes de cada grupo foram submetidos a cortes seriados no sentido mésio-distal obtendo-se fatias de 1,0mm. Estas fatias foram divididas para confecção de entalhes na dentina do assoalho da câmara pulpar ou na interface de união dentina-resina do assoalho, obtendo-se uma constrição em forma de ampulheta, com área de aproximadamente 1,0mm2. Os espécimes foram submetidos ao ensaio de microtração para avaliação da alteração na resistência coesiva em dentina e resistência de união dentina-resina. Dez dentes foram submetidos ao teste de nanoinfiltração coronária com nitrato de prata. Os resultados foram avaliados estatisticamente e demonstraram não haver diferença significativa entre os grupos quanto a resistência coesiva da dentina. No entanto, a resistência de união dentina-resina foi menor (p<0,05) para os grupos que utilizaram EDTA 17%. Todos os grupos apresentaram um padrão de fratura tipicamente mista. O teste de nanoinfiltração não apresentou padrões diferentes entre os grupos avaliados em MEV, tendo a infiltração ocorrida apenas no trajeto dos túbulos que ficaram expostos ao agente traçador, não havendo também uma correlação entre a resistência de união e a nanoinfiltração. Conclui-se assim, que as substâncias químicas auxiliares testadas, com exceção do EDTA 17%, não promoveram alterações na resistência de união dentina-resina no assoalho da câmara pulpar / Abstract: Most of the endodontic treatment failure cases are directly related to inadequate or absent restoration, which leads to coronal microleakage and root canal system recontamination. Hence, the aim of this research was to evaluate the influence of chemical substances auxiliary to the endodontic treatment on the adhesive system adherence to the deep pulp chamber dentin. Crowns of intact molars were transversally sectioned at 3 mm above the enamel-cement junction, so that the pulp chamber floor was exposed. The teeth were divided in 6 groups according to the auxiliary chemical substance used during the treatment, G1- physiologic solution, G2 17% EDTA, G3 5.25%NaOCl, G4- 5.25% NaOCl + 17% EDTA, G5- 2% Chlorhexidine gel and G6- 2% Chlorhexidine solution. All specimens of all groups were immersed in the respective chemical substance for 30 minutes. Afterwards, 4 mm of the pulp chamber were filled with adhesive system Single Bond® (3M, St. Paul, MN, USA) and the compound resin Z250® B2 shade (3M, St. Paul, MN, USA). Twenty teeth of each group were serially cut from mesial to distal into 1.0 mm slices. These slices were trimmed to an hourglass shape cuts with a cross-sectional area of 1.0 mm2 on the dentin of the pulp chamber floor or in the dentin-resin bond interface of the pulp chamber floor. Microtensile tests were used on the slices to evaluate cohesive resistance alterations on dentin and resistanc e of the dentin-resin bond. Ten teeth were submitted to coronary nanoleakage tests with silver nitrate. The results were statistically analyzed and showed that there are no statistical significant differences between groups regarding the cohesive resistance of the dentin. However, the dentinresin bond was lower (p<0.05) in the 17% EDTA group. All groups showed a typically mixed fracture pattern. The nanoleakage test did not show different patterns between groups evaluated on the SEM, as the infiltration occurred only on the pathways of tubules exposed to the marker. Moreover, there was no correlation between union resistance and nanoleakage. In conclusion, the auxiliary chemical substances tested, except the 17% EDTA, did not influence the dentin-resin bond mechanism on the pulp chamber floor / Doutorado / Endodontia / Doutor em Clínica Odontológica
3

Variação da temperatura no interior da câmara pulpar em função de diferentes fontes de luz e camadas de resina composta. In vitro / In vitro temperature variation inside the pulp chamber regard different light sources and composite layers

Ligia Maria Lima Andreatta 31 March 2015 (has links)
Este estudo in vitro avaliou a variação da temperatura no interior da câmara pulpar durante a fotoativação do sistema adesivo e incrementos de resina composta em função de diferentes fontes de luz, testando as hipóteses nulas de que estes fatores não interferem na temperatura intra câmara pulpar. Foram selecionados 10 incisivos bovinos, seccionados na região radicular 3 mm além da junção amelocementária. Uma cavidade retangular (10X8mm) foi confeccionada no centro da face vestibular, com espessura padronizada do remanescente dentinário da parede axial em 1 mm. A câmara pulpar foi preenchida com pasta térmica e o sensor termopar tipo K foi introduzido na câmara em contato com o remanescente dentinário. A elevação da temperatura foi aferida durante 40s de fotoativação do sistema adesivo (SBMP) e dos 3 incrementos consecutivos de 1mm de resina composta (Z250), com diferentes fontes de luz. As fontes utilizadas foram: Luz Halógena 755mW/cm2 (Curing Light XL 3000 3M), Luz emitida de diodo (LED) de baixa densidade de potência 400 mW/cm2 (OptiLight LD Max - Gnatus), e LED de alta densidade de potência 1500mW/cm2 (VALO Ultradent). O LED de alta densidade de potência proporcionou os maiores aumentos de temperatura, seguido da luz halógena e do LED de baixa densidade de energia. A polimerização do sistema adesivo seguido do primeiro incremento de resina determinou os maiores aumentos de temperatura. A partir do segundo incremento da resina composta, o material restaurador atuou como isolante térmico reduzindo o aumento de temperatura. Independente da fonte de luz e etapa restauradora, o aumento no tempo de polimerização foi determinante no aumento de temperatura, rejeitando as hipóteses nulas testadas. / This In vitro study evaluated the temperature variation inside the pulp chamber during the curing of the adhesive and composite layers with different light sources, testing the null hypothesis that these factors do not affect the temperature of the intra pulp chamber. Ten bovine incisors were selected and sectioned beyond the root region at 3 mm of the cementoenamel junction. A rectangular cavity (10x8mm) was made in the center of the buccal surface, with the remaining 1mm dentin thickness standardized at the axial wall. The pulp chamber was filled with thermal paste and a type K thermocouple sensor was introduced into the chamber in contact with the remaining dentin. The temperature was measured for 40s during the curing of the adhesive system (SBMP) and 3 consecutive layers of 1mm composite resin (Z250) was applied with three different light sources. The sources used were: Halogen Light 755mW/cm2 (Curing Light XL 3000 - 3M), Light emitted diode (LED) low power density 400 mW/cm2 (Optilight LD Max - Gnatus), and high power density LED 1500mW/cm2 (VALO Ultradent). For all light sources, the temperature readings decreased as the cavity was filled, with statistically significant differences until the second layer of composite resin. The high power density LED showed a significantly higher temperature average (42.78+1.56oC) than the other light sources, and the lowest was the average of the low power density LED (37.81+0.12oC). It could be concluded that both the light source, and the number of layers interfered with the temperature variation, rejecting the null hypotheses tested.
4

Imagem in vitro do remanescente dentinário e da cavidade pulpar através da tomografia por coerência óptica

Daniella Diniz Fonsêca, Déborah 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T22:57:02Z (GMT). No. of bitstreams: 2 arquivo4004_1.pdf: 1487294 bytes, checksum: 3fbd062a21c117a323cad46d8f30d86c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Este trabalho reporta a aplicação da tomografia por coerência óptica (TCO) em gerar imagens do remanescente dentinário e da câmara pulpar, in vitro, de dentes humanos. Imagens bi-dimensionais do remanescente dentinário e da câmara pulpar, paralelas ao longo eixo do dente, foram obtidas através de dois sistemas de TCO operando em 1280nm e 850nm. Imagens geradas por tomografia de feixe cônico usando o i-CAT® foram utilizadas como padrão ouro. Os resultados demonstraram a eficácia das duas técnicas em visualizar os componentes do complexo dentinopulpar, porém o sistema com comprimento de onda em 1280nm apresentou maior profundidade de penetração em dentina quando comparado ao de 850nm, como era esperado devido às diferenças do coeficiente de espalhamento e de absorção neste tecido. A tomografia por coerência óptica apresenta grande potencial de utilização na prática clínica, prevenindo exposição acidental da polpa e promovendo tratamento restaurador preventivo
5

Espessura do assoalho da câmara pulpar de molares decíduos inferiores tratados pelo TRA, pulpotomia e pulpectomia

Santos, Vanessa Aparecida Carvalho [UNESP] 13 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-13Bitstream added on 2014-06-13T19:15:12Z : No. of bitstreams: 1 santos_vac_me_araca.pdf: 189502 bytes, checksum: 8bb16c4dcf6706b3fd4ec9c0545b725c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O assoalho da câmara pulpar de molares decíduos apresenta tecido dentinário permeável podendo conter também canais acessórios que conectam a polpa com a área de furca, estabelecendo uma via de transmissão de toxinas bacterianas. O resultado deste processo culmina com danos no assoalho da câmara pulpar, chegando a ocasionar a sua redução. O objetivo deste estudo é o de verificar a espessura do assoalho da câmara pulpar de molares decíduos inferiores, através de imagens radiográficas, relacionando-a com os seguintes tratamentos dentários: TRA (tratamento restaurador atraumático), pulpotomia e pulpectomia. A amostra foi constituída por 160 radiografias periapicais de crianças assistidos na Faculdade de Odontologia de Araçatuba-UNESP. Os prontuários foram analisados com o objetivo de obter e registrar dados clínicos e informações sobre o tratamento instituído a cada dente. As radiografias selecionadas foram escaneadas e analisadas pelo programa Digora for Windows 1.51. Os dados finais foram submetidos aos testes estatísticos T-Student e análise de variância ANOVA (1%), onde constatamos: dentes do grupo com tratamento apresentaram menor medida de espessura do assoalho da câmara pulpar; os segundos molares apresentaram medidas de espessura do assoalho da câmara pulpar maiores que os primeiros molares; quanto mais invasivo o tratamento, menor a espessura do assoalho. / The pulpal chamber floor of the deciduous molars presents permeable dentinal tissue may also contain accessories canals that connect the pulp with the furcation area, establishing a transmission way of bacterial toxins. The result of this procedure leads with damages of the pulpal chamber floor, causing its reduction. The objective of this study is to verify the pulpal chamber floor thickness of lower deciduous molars through periapical radiographies, relating it with the following dental treatments: ART (atraumatic restorative treatment), pulpotomy and pulpectomy. The sample consisted of 160 periapical radiographies of children treated in Dental School in Araçatuba- UNESP-Brazil. The records were analyzed in order to obtain and to register clinical data and information about the treatment of each tooth. The radiographies were scanned and analyzed by Digora program for Windows 1.51. The final data were submitted to statistical T-Student test and one-way ANOVA test with a significance level of 1%. The teeth that received treatment presented thinner pulp chamber floor when compared to untreated teeth. The pulp chamber floor thickness of the second molars was greater than the first molars. Therefore, within the limitations of this study it can reduces the pulp floor thickness.
6

Influencia da irrigação endodontica sobre a microdureza, morfologia e rugosidade de dentes deciduos e permanentes / Endodontic irrigation effect on microhardness, morphology and roughness in primary and permanent teeth

Pascon, Fernanda Miori, 1977- 12 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Tese (doutorado) - Universidade Estadual de Campina, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T09:08:02Z (GMT). No. of bitstreams: 1 Pascon_FernandaMiori_D.pdf: 20418378 bytes, checksum: 123cef34dc5e16d51cd9c6553ae586c5 (MD5) Previous issue date: 2008 / Resumo: A utilização de substâncias químicas auxiliares, durante o tratamento endodôntico, pode alterar a composição química e as propriedades físicas da estrutura dentinária corono-radicular. Além disso, pode interferir no processo de união do material restaurador às estruturas dentinárias da câmara pulpar. Dessa maneira, pesquisas devem ser realizadas possibilitando a indicação de uma substância, que apresente o mínimo efeito nas propriedades mecânicas dentinárias, enquanto exerce o efeito de debridamento desejado. No intuito de facilitar a apresentação desta Tese, a mesma foi dividida em três capítulos, como descrito nas proposições seguintes. Capítulo 1: revisar sistematicamente a literatura a respeito dos efeitos da solução de hipoclorito de sódio nas propriedades mecânicas da dentina do canal radicular quando a mesma é utilizada durante o tratamento endodôntico. Capítulo 2: verificar os efeitos de diferentes substâncias químicas auxiliares (soro fisiológico, hipoclorito de sódio, clorexidina gel, peróxido de uréia - Endo-PTC® e EDTA) na microdureza (realizada por meio do teste de microdureza Vickers) e morfologia (realizada por meio de análise em Microscopia Eletrônica de Varredura) da dentina da câmara pulpar de dentes anteriores decíduos e permanentes. Capítulo 3: avaliar o efeito de substâncias químicas auxiliares (soro fisiológico, hipoclorito de sódio, clorexidina gel, peróxido de uréia - Endo-PTC® e EDTA) na rugosidade superficial da dentina da câmara pulpar de dentes decíduos e permanentes. Baseando-se na revisão de literatura pôde-se concluir que há forte evidência de que o hipoclorito de sódio altera as propriedades mecânicas da dentina radicular, quando o mesmo é utilizado como solução irrigadora durante o tratamento endodôntico. O uso de substâncias químicas auxiliares diminuiu os valores de microdureza dentinária Vickers tanto para dentes decíduos quanto para os permanentes. Observaram-se resultados não conclusivos com o uso do EDTA 17% na dentina da câmara pulpar dos dentes decíduos e permanentes uma vez que a microdureza superficial não pôde ser mensurada. A solução de hipoclorito de sódio 1% e 5,25% produziu os menores valores de microdureza Vickers para dentes decíduos e permanentes, comparados à clorexidina gel 2% e grupo controle (soro fisiológico). Alterações morfológicas foram observadas quando a dentina da câmara pulpar foi irrigada com solução de hipoclorito de sódio 1% ou 5,25% associados ao EDTA 17%, EDTA 17% utilizado isoladamente e clorexidina gel 2% associada ou não ao EDTA 17%. Em relação à rugosidade superficial pôde-se concluir que a irrigação da dentina da câmara pulpar aumentou a rugosidade superficial dos dentes permanentes e decíduos tratados com hipoclorito de sódio 1% e 5,25% associados ao EDTA 17%. / Abstract: Irrigation solutions, endodontic auxiliary chemical substance, and chelating agents used on root canal treatment might yield changes in the chemical composition and physical properties of dentin surface, and affect its interaction with materials used for coronal sealing. Thus, studies are required to select a suitable chemical agent, which has minimal effects on the mechanical properties of the tooth whilst achieving the desired debridement effect. In order to facilitate the accomplishment of this Thesis, it was divided into three chapters, as described on the following descriptions. Chapter 1: to present a systematic review on the effect of sodium hypochlorite on the mechanical properties of root canal dentin, considering its use as an irrigation solution. Chapter 2: to verify the effects of endodontic irrigants, auxiliaries chemicals substances and chelating agent on the microhardness (Vickers Hardness test) and morphology (Scanning Electron Microscopy) of the pulp chamber dentin in primary and permanent teeth. Chapter 3: to evaluate the effect of endodontic irrigants, auxiliaries chemicals substances and chelating agent on the roughness of the pulp chamber dentin of primary and permanent teeth. Based on literature review it could be concluded that there is strong evidence showing that sodium hypochlorite alters the mechanical properties of root canal dentin, when used as an endodontic irrigant. The use of irrigation solutions decreased the Vickers Hardness Number values for both permanent and primary teeth. Inconclusive results were observed when 17% EDTA was used, since it could not be measured. Sodium hypochlorite provides lower Vickers Hardness Number for primary and permanent teeth, compared with 2% chlorhexidine and control group (saline solution). Morphological alterations were observed when pulp chamber irrigation was performed by 1% or 5.25% sodium hypochlorite associated with 17% EDTA, 17% EDTA, and 2% chlorhexidine gel associated or no with 17% EDTA. Regarding surface roughness, it was concluded that pulp chamber irrigation with 1% and 5.25% sodium hypochlorite associated with 17% EDTA increases pulp chamber roughness of primary and permanent teeth. / Doutorado / Odontopediatria / Doutor em Odontologia

Page generated in 0.0499 seconds