• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 3
  • 3
  • 2
  • 1
  • 1
  • Tagged with
  • 29
  • 22
  • 9
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Grön ammoniak i Norra Sverige : Konceptstudie kring förutsättningar för grön ammoniakproduktion i Norra Sverige / Green ammonia in northern Sweden

Hägglund, Fredrik January 2022 (has links)
Europeiska Unionen presenterade den 8 juni 2020 sin vätgasstrategi i syfte för att minska koldioxidutsläppen. Det unionen vill uppnå med sin vätgasstrategi är att uttnytja konceptet Power-to-X där elektricitet omvandlas till energi. Om elektricitetkällan kommer från förnyelsebar energi kommer grön vätgas produceras. Problemet med vätgas idag är lagring, transport och hanteringstrukturen för ämnet men vätgas kan lagras i flertal applikationer. En av de mest lovande lagringsalternativen är ammoniak som bildas när vätgas med kvävgas reagerar med varandra via ammoniaksyntes. Eftersom vätgasproduktionen idag använder fossila bränslen kommer även dess applikation göra det, men med grön vätgas kommer dess applikation även att bli grön. Idag står ammoniakproduktion för 2 % av fossilbränsleanvändning globalt och frigör mer än 400 miljoner ton CO2 årligen. Dessa utsläpp skulle försvinna om produktionen av ammoniak gjordes med Power-to-X konceptet. Syftet med detta examensarbete är att undersöka förutsättningarna ur ett ekonomiskt, tekniskt och säkerhetsmässigt hållbart Power-to-X koncept i form av en Grön Ammoniakanläggning i Norra Sverige. Det innebär att processer för en ammoniakproduktion skall analyseras ur ett teknisk synvinkel där fokus på funktion mot grön ammoniak är i fokus. Den ekonomiska synvinkeln innebär vad kapitalkostnaden (CAPEX) blir för anläggningen samt driftkostnaden (OPEX) som processen får. Arbetet innehåller först en analys av de processer som krävs för att kunna producera ammoniak. Därefter en analys över möjliga tekniker för dessa processer, hur väl de fungerar mot grön ammoniak och vilka antaganden som är i detta arbete. Anläggningen skulle vara storskalig vilket innebär en produktion på 500 ton NH3 $/dag. Det är även antaget en kontinuerlig eltillförsel samt att elnät redan är tillgänglig. Detta gav att vätgasproduktionen gjordes med en PEM-elektrolys, där kvävgas fås från kryogen destillation och ammoniak produceras med HB-processen. Resultatet visades att anläggningens CAPEX och OPEX blev 2 820 MSEK respektive 1 272 MSEK/år. Den dominerande faktorn för kapitalkostnaden var för vätgasproduktion som utgjorde 60 % av CAPEX. Den höga kostnaden för PEM-elektrolys är dels för att utvecklingen av processen inte är fullbordad, där utvecklingen för tekniken skulle kunna ge en stor kostnadsreducering. Det elbehov som anläggningen kräver är 1,6 TWh och och utgör en påverkan på OPEX är 55,4 %. Den process som kräver mest energi är vätgasproduktionen vilket omfattar 94 % av hela anläggningens totala elbehov. En stor anledning till de dyra driftkostnaderna är elpriset. I detta arbete valdes elpriset till ett medelvärde för SE1 i Sverige under en 10 års period. I ett verkligt scenario hade vätgasproduktionen kunnat optimeras för uppnå billigare drift.
12

A framework for economic analysis of network architectures

Karakus, Murat 12 1900 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / This thesis firstly surveys and summarizes the state-of-the-art studies from two research areas in Software De fined Networking (SDN) architecture: (i) control plane scalability and (ii) Quality of Service (QoS)-related problems. It also outlines the potential challenges and open problems that need to be addressed further for more scalable SDN control planes and better and complete QoS abilities in SDN networks. The thesis secondly presents a hierarchical SDN design along with an inter-AS QoS-guaranteed routing approach. This design addresses the scalability problems of control plane and privacy concerns of inter-AS QoS routing philosophies in SDN. After exploring the roots of control plane scalability problems in SDN, the thesis then proposes a metric to quantitatively evaluate the control plane scalability in SDN. Later, the thesis presents a general framework for economic analysis of network architectures and designs. To this end, the thesis defines and utilizes two metrics, Unit Service Cost Scalability and Cost-to-Service, to evaluate how SDN architecture performs compared to MPLS architecture in terms of unit cost for a service and cost of introducing a new service along with giving mathematical models to calculate Capital Expenditures (CAPEX) and Operational Expenditures (OPEX) of a network. Moreover, the thesis studies the problem of optimal final pricing for services by proposing an optimal pricing scheme for a service request with QoS in SDN environment while aiming to maximize benefits of both service providers and customers. Finally, the thesis investigates how programmable network architectures, i.e. SDN, affect the network economics compared to traditional network architectures, i.e. MPLS, in case of failures along with exploring the economic impact of failures in different SDN control plane models.
13

A FRAMEWORK FOR ECONOMIC ANALYSIS OF NETWORK ARCHITECTURES

Murat Karakus (5931083) 17 January 2019 (has links)
<div>This thesis firstly surveys and summarizes the state-of-the-art studies from two research areas in Software Defined Networking (SDN) architecture: (i) control plane scalability and (ii) Quality of Service (QoS)-related problems. It also outlines the potential challenges and open problems that need to be addressed further for more scalable SDN control planes and better and complete QoS abilities in SDN networks. The thesis secondly presents a hierarchical SDN design along with an inter-AS QoS-guaranteed routing approach. This design addresses the scalability problems of control plane and privacy concerns of inter-AS QoS routing philosophies in SDN. After exploring the roots of control plane scalability problems in SDN, the thesis then proposes a metric to quantitatively evaluate the control plane scalability in SDN. Later, the thesis presents a general framework for economic analysis of network architectures and designs. To this end, the thesis defines and utilizes two metrics, Unit Service Cost Scalability and Cost-to-Service, to evaluate how SDN architecture performs compared to MPLS architecture in terms of unit cost for a service and cost of introducing a new service along with giving mathematical models to calculate Capital Expenditures (CAPEX) and Operational Expenditures (OPEX) of a network. Moreover, the thesis studies the problem of optimal final pricing for services by proposing an optimal pricing scheme for a service request with QoS in SDN environment while aiming to maximize benefits of both service providers and customers. Finally, the thesis investigates how programmable network architectures, i.e. SDN, affect the network economics compared to traditional network architectures, i.e. MPLS, in case of failures along with exploring the economic impact of failures in different SDN control plane models. </div>
14

Réseaux de Transport WDM: Planification de Réseaux Translucides et Economie d'Energie

Youssef, Mayssa 16 December 2011 (has links) (PDF)
Les réseaux d'opérateurs sont actuellement confrontés à multiples défis dont les coûts de réseaux, la disponibility, l'éco-durabilité et la qualité de service. Dans les réseaux "opaques", le signal optique est soumis à une régénération systématique à chaque passage par un noeud. Les réseaux "transparents" (ou tout-optiques) présentent une détérioration de la qualité du signal, due aux effets de dégradation par la couche physique s'accumulant depuis la source jusqu'à la destination. Les réseaux "translucides" offrent un compromis entre les deux types précédents. Dans de tels réseaux, une fraction des noeuds du réseau sont équipés de régénérateurs électriques, tandis que les autres sont complètement transparents aux signaux optiques. Dans un premier temps, nous avons proposé une technique d'optimisation pour la planification de réseaux translucides reposant sur une optimisation croisée entre les coûts CapEx et OpEx du réseau. L'algorithme développé fournit une solution pour le problème de routage et d'affectation de longueur d'onde tout en plaçant stratégiquement les régénérateurs. Dans un deuxième temps, nous avons étudié la planification de réseaux WDM tenant compte de la consommation énergétique, dans un contexte de trafic pré-planifié. Les cartes client servant d'interface entre le routeur IP et le switch optique présentent une opportunité pour réduire la consommation énergétique. Dans ce cadre, nous avons proposé une approche pour optimiser le nombre et l'utilisation de ces équipements en profitant de la corrélation spatio-temporelle entre les requêtes.
15

Poskytování ERP v "Cloudu" / ERP IN CLOUD

Michel, Milan January 2013 (has links)
This diploma thesis focuses on the problematics of providing ERP in Cloud. The main objectives of this thesis lie in either identification of the situation in the ERP market, provision of an outline of particular deployment models, evaluation of strong and weak parts of ERP in cloud in contractor's and customer's point of view and in charting of potential risks and chances for the area. Obtained theoretical findings are utilized in the practical part of the thesis. Its significant portion is dedicated to proposition of methodology for the selection of right ERP model supply. This is then used for the particular choice of Oracle JD Edwards implementation. To achieve these objectives author realizes an analysis of electronic and printed resources as well as consultations with experts and also uses his own practical experiencies from Algotech Corporation. The main contribution of this thesis is in the creation of comprehensive sum of problematics and in the formation of methodology for the right type of deployment selection. This is all considering the further application and verification on the example. Thesis is divided into five theme parts -- ERP, Cloud, ERP in Cloud, methodology and practical setting of the presented methodology.
16

Optimisation of a hollow fibre membrane bioreactor for water reuse

Verrecht, Bart January 2010 (has links)
Over the last two decades, implementation of membrane bioreactors (MBRs) has increased due to their superior effluent quality and low plant footprint. However, they are still viewed as a high-cost option, both with regards to capital and operating expenditure (capex and opex). The present thesis extends the understanding of the impact of design and operational parameters of membrane bioreactors on energy demand, and ultimately whole life cost. A simple heuristic aeration model based on a general algorithm for flux vs. aeration shows the benefits of adjusting the membrane aeration intensity to the hydraulic load. It is experimentally demonstrated that a lower aeration demand is required for sustainable operation when comparing 10:30 to continuous aeration, with associated energy savings of up to 75%, without being penalised in terms of the fouling rate. The applicability of activated sludge modelling (ASM) to MBRs is verified on a community-scale MBR, resulting in accurate predictions of the dynamic nutrient profile. Lastly, a methodology is proposed to optimise the energy consumption by linking the biological model with empirical correlations for energy demand, taking into account of the impact of high MLSS concentrations on oxygen transfer. The determining factors for costing of MBRs differ significantly depending on the size of the plant. Operational cost reduction in small MBRs relies on process robustness with minimal manual intervention to suppress labour costs, while energy consumption, mainly for aeration, is the major contributor to opex for a large MBR. A cost sensitivity analysis shows that other main factors influencing the cost of a large MBR, both in terms of capex and opex, are membrane costs and replacement interval, future trends in energy prices, sustainable flux, and the average plant utilisation which depends on the amount of contingency built in to cope with changes in the feed flow.
17

Quantitative Risk Assessment of Wave Energy Technology

Ericsson, Emil, Gregorson, Eric January 2018 (has links)
European Commission (2011) aims to reduce the greenhouse gas emission sby 85-95% by 2050 in comparison to 1990’s levels. Wave energy could be an important step to archiving this goal. This report aims to develop a quantitative risk assessment for the Uppsala University's wave energy converter. Failure rates have been collected from various databases and reports and have been processed accordingly in order to implement them in the risk analysis. CAPEX, OPEX and possible downtime windows have been estimated. A fault tree analysis (FTA) has estimated the total unavailability, unreliability and downtime. Furthermore an economical assessment model using Monte Carlo and the unreliability data from the FTA has been developed, estimating the expected LCOE and OPEX/WEC for parks consisting of 20, 100, and 200 WECs (wave energy converters). The result show that the O-ring seal has the largest impact on both the unavailability, and the economy of the OPEX/WEC. Second biggest contributor is the translator bearing failure. The study also shows that the CAPEX cost has to be reduced to make the LCOE competitive in comparison to other renewable sources. A comparison between the system unavailability and unreliability has also been done in terms of different component parameters.
18

Cost-effective Communication and Control Architectures for Active Low Voltage Grids

Armendáriz, Mikel January 2017 (has links)
The monitoring and control of low voltage distribution grids has historically been disregarded due to the unidirectional flow of power. However, nowadays the massive integration of distributed energy resources into distribution grids, such as solar photovoltaics, distributed storage, electric vehicles and demand response programs, presents some challenges. For instance, the unidirectional top-down power flow is being replaced by power flows in any direction: top-down and bottom-up. This paradigm shift adds extra regulatory, economic, and technical complexity for the Distribution System Operators (DSO). Thus to overcome the possible operational constraints, thermal limits, or voltage problems in the grid, an update of the existing electricity infrastructures is required. In response to this new situation, this thesis investigates the cost-effective communication and control architectures that are required for active low voltage grid monitoring and control applications, considering the regulatory constraints and the efficient utilization of the assets from a DSO’s perspective. The solutions include: i) optimal sensor placement configuration to perform low voltage state estimation, ii) optimal metering infrastructure designs for active low voltage monitoring applications, iii) coordinated control strategies to allow the integration of microgrid-like structures into the distribution grids, iv) optimal placement of actuators for operating the control strategies, v) a multiagent-based control solution for self-healing and feeder reconfiguration applications, and vi) a framework model and simulations to assess the reliability of the ICT infrastructure that enables the monitoring and control applications. As concluding remark, since the deployment of technology at low voltage grids is restricted to assets owned by the DSO, the operability of the grid is limited. This condition makes it so that the required communication and control enhancement solutions shall prioritize cost-effectiveness over comprehensiveness and complexity. Thus, the results from the presented studies show that it is essential to perform thorough cost-benefit analyses of the potential improvement solutions for each grid, because this will allow deploying the right technology only at the necessary locations. / <p>QC 20171106</p><p></p>
19

Theoretical and experimental investigation of liquid droplets flashing for low cost seawater desalination

Alrowais, Raid 04 1900 (has links)
The high specific energy consumption from all existing seawater desalination methods has heightened the motivation for having more efficient and greener desalination processes to meet the future goals of sustainable seawater desalination. One of the promising thermally-driven desalination methods is the direct-contact spray evaporation and condensation (DCSEC) where the excess enthalpy between feed and equilibrium states of evaporator chambers is exploited with reasonably high flashing efficiency. Further improvements in energy efficacy of DCSEC are boosted by firstly the incorporation of micro/nano-bubbles (M/NB) where micro or nano size subcooled vapor are embedded in the sprayed liquid droplets of evaporator, thereby lowering the temperature brine in evaporator and minimizing the thermal equilibrium effect of brine. The presence of subcooled bubbles increased the available surface area for heat transfer. Secondly, the concept of an evaporator-condenser pair of DCSEC could be extended to a multi-stage arrangement where the latent heat of vapor condensing on the water droplets sprayed within the condenser is recovered. From the experiments, the effect of incorporating the (M/NB) in the DCSEC at optimum feed flow rate yields more than 34% increase in distillate production at feed temperatures greater 47oC and the cooling inlet temperature set at 35oC. The other salient improvement found from the experiments is the increase in performance ratio (PR) up to 3.3 for a 6-stage configuration. This quantum jump in the PR is attributed to the heat recovery effect by as much as 70% of the total heat input. Arising from the DCSEC design, the implicit benefits are the low capital and operational cost, i.e., low CAPEX and OPEX. The former savings is attributed zero physical interfaces such as tube-based heat exchangers or membranes, whilst the latter savings is contributed by significant lesser use of chemicals in the pre-treatment of seawater feed. Lastly, the accompanied benefit is the robustness of the DCSEC processes where it could within stand high salinity of the brine, typically as high as 200,000 ppm.
20

Pořizovací a provozní náklady (efektivnost) různých typů vedení VN / The acquisition and operating costs (efficiency) of different types of HV lines

Veselý, Tomáš January 2018 (has links)
The master´s thesis deals with the evaluation of the efficiency of investment of various types of high voltage lines in terms of capital expenditures and operating expenses. The thesis describes the issue of the regulated environment in the field of electricity, the analysis of the pricing for ensuring the distribution of electricity and the analysis of the capital expenditures and operating expenses of the authorized returns of the distribution company operator. Subsequently, an analysis of the capital expenditures and operating expenses of the overhead and cable lines is processed. The particular components of the operating costs are determined either by annual energy loss per unit of length, an annual hourly labor demand, or an annual cost per unit of length. Another point is the evaluation of the investment efficiency for two different model lines, evaluation of capital expenditures and operating expenses, allowed investment returns and economic evaluation. The conclusion of this pursuit is the comparison of both types of lines, both with the view of capital expenditures and operating expenses, as well as with the view of economic appreciation.

Page generated in 0.024 seconds