Design of an impedance guided intra-arterial catheter

Schwartz, Paul 03 1900 (has links)
Thesis (MScEng)--Stellenbosch University, 2013. / ENGLISH ABSTRACT: This thesis entails the stages of the development of an arterial catheter capable of being guided by the impedance of human tissue. Such a device would be desired in cases where it is not possible to locate the artery of a patient using anatomical landmarks. This design thus aims to improve the accuracy of first time placement of arterial catheters. The thesis entails the literature study done in order to initiate the development of said device, followed by preliminary concept design and evaluation. The thesis also contains a description of all experimental phases, done on in vitro tissue samples, in vivo samples in living porcine subjects and in vivo samples in living human patients. Experiments were performed to determine if any repeatable noticeable difference in tissue impedance could be identified and utilized in the hope of guiding this device using acquired differences in tissue impedance. The different stages of development for the prototype used in these tests are also described in detail. In addition, the results of the different tests are presented, which prove that there is a significant difference between blood tissue impedance and the surrounding tissue types encountered, allowing for guidance of the proximal tip of the arterial catheter, based on the tissue impedance measured. Finally, the thesis entails a description of further work which could be performed if this concept were to be considered as a marketable product. / AFRIKAANSE OPSOMMING: Hierdie tesis behels die verskillende stappe in die ontwerp van 'n kateter wat deur middel van die verskillende impedansie vlakke van biologiese weefsel gelei kan word in die menslikke liggaam. Sò ‘n toestel sal behulpsaam wees in gevalle waar plasing nie gedoen kan word met die behulp van anatomiese landmerke nie. Hierdie ontwerp mik dus om die akkuraatheid van die plasing van kateters te verbeter. Die tesis behels die literatuur studies benodig om sò 'n toestel te ontwerp, gevolg deur voorlopige konsep ontwerpe en die evaluasie van hierdie konsepte. Die tesis behels ook die verskillende eksperimentele fases van die projek; eksperimente op in vitro weefsel monsters, in vivo diere toetse en in vivo kliniese toetse op menslike weefsel. Al hierdie eksperimente is gedoen om te bepaal of enige herhaalbare, waarneembare verskil in weefsel impedansie geidentifiseer kan word en dus gebruik word met die hoop om diè teoretiese kateter te lei met behulp van diè verskil in weefsel impedansie. Die verskillende stappe van die ontwerp van die prototipes gebruik in hierdie eksperimente word ook in detail beskryf. Die resultate van die verskillende eksperimente word ook aangebied, wat bewys dat daar 'n beduidende verskil is tussen die impedansie van bloed weefsel en die impedansie van die aanliggende weefsel tipes, wat dus impliseer dat die proksimale punt van die kateter gelei kan word deur die gemete impedansie by die punt van die toestel, gebaseer op die resultate wat gevind is. Laastens behels die tesis ook 'n beskrywing van toekomstige werk wat gedoen kan word indien die konsep ontwikkel word tot 'n bemarkbare produk.
32

Sítio de inserção do cateter venoso no paciente queimado e ocorrência de infecção: revisão sistemática de literatura / Sites of venous catheter insertion in burn patients and occurrence of infection: systematic review of the literature.

Silva, Caroline Lopes Ciofi 05 November 2012 (has links)
Pacientes queimados possuem alto risco de infecção e desenvolvimento de sepse relacionado a diversos fatores, entre eles a presença de dispositivos invasivos, como os cateteres venosos indispensáveis para o tratamento desses pacientes. O objetivo desse estudo foi identificar e avaliar as evidências disponíveis na literatura, por meio de revisão sistemática, sobre possível associação entre o sítio de inserção do cateter venoso em pacientes queimados e o aumento da ocorrência de infecção relacionada ao cateter. Analisaram-se as seguintes bases de dados: MEDLINE, LILACS, CINAHL, EMBASE, Web of Science e The Cochrane Library. Utilizaram-se os descritores controlados e não-controlados adaptados para cada base de dados e, para a combinação desses, utilizou-se o operador boleano AND. As buscas ocorreram entre os meses de outubro e dezembro de 2011. Após leitura dos títulos, resumos e textos na íntegra, considerando-se os critérios de inclusão e exclusão previamente definidos, selecionou-se nove estudos. Utilizou-se um roteiro elaborado e validado para coleta dos dados e avaliação crítica dos estudos. A síntese dos dados ocorreu de forma descritiva. Os estudos foram classificados segundo duas categorias temáticas: infecção relacionada ao cateter e inserção do cateter através da queimadura ou em área próxima à queimadura; e infecção relacionada ao cateter e sítios anatômicos de inserção do cateter venoso. Na primeira categoria, foram incluídos quatro estudos que compararam a ocorrência de infecção relacionada ao cateter e a distância entre a área queimada e o sítio de inserção do cateter venoso. Classificaram-se todos os estudos como nível de evidência IV. Em dois deles, os resultados mostraram diferenças não significantes das taxas de infecção. Em outros dois estudos, os resultados mostraram diferenças significantes entre as taxas de infecção, sendo maiores para os cateteres inseridos próximos ou através da lesão. Na segunda categoria temática foram incluídos cinco estudos. Em dois dos estudos (nível de evidência IV), os cateteres inseridos na veia femoral apresentaram maiores taxas de sepse relacionada ao cateter. Em outro estudo (nível de evidência IV), ao analisar pacientes adultos e pediátricos, maiores taxas de infecção estavam associadas aos cateteres inseridos na veia subclávia; porém, na análise entre os pacientes pediátricos, maiores taxas de infecção estavam associadas às inserções na femoral. Em outro estudo (nível IV), não foram identificadas diferenças significantes nas taxas de infecção entre cateteres venosos centrais e cateteres venosos centrais de inserção periférica. Esse tipo de cateter pode ser uma alternativa segura e efetiva para pacientes queimados. O número limitado de estudos selecionados para essa revisão demonstra a necessidade de realização de pesquisas científicas relacionadas ao tema. Na área da enfermagem, investigações futuras sobre técnicas e coberturas para o curativo do sítio de inserção do cateter venoso inserido próximo ou através da queimadura são fundamentais, já que muitas vezes a inserção nesse sítio é inevitável. Novas tecnologias também devem ser avaliadas, como o CCIP, para que seu uso esteja fundamentado cientificamente. / Burn patients are at high risk of infection and development of sepsis related to several factors, including the presence of invasive devices such as venous catheters needed to treat these patients. This study aimed to identify and evaluate the evidence available in the literature through systematic review on the possible association between the sites of venous catheter insertion in burn patients and the increasing of occurrence of catheter-related infection. The following databases were analyzed: MEDLINE, LILACS, CINAHL, EMBASE, Web of Science and The Cochrane Library. It was used controlled and uncontrolled descriptors adapted for each database and, for combining them, the Boolean operator AND. The searches occurred between October and December 2011. After reading the titles, abstracts and full texts, and considering the inclusion and exclusion criteria previously defined, nine studies were selected. A script developed and validated for data collection and critical evaluation of the studies was used. Descriptive data synthesis was performed. Studies were classified according to two thematic categories: catheter-related infection and catheter insertion through burn or near the burn area and catheter- related infection and anatomical sites of venous catheter insertion. In the first category, four studies that compared the occurrence of catheter-related infection and the distance between the burn area and the site of insertion of the venous catheter were included. All studies were classified as evidence level IV. In two of them, the results showed no significant differences in infection rates. In two other studies, the results showed significant differences in infection rates, being higher for catheters inserted near or through the lesion. The second thematic category included five studies. In two of the studies (evidence level IV), the catheters inserted in the femoral vein had higher rates of catheter-related sepsis. In another study (evidence level IV), when analyzing adult and pediatric patients, higher rates of infection were associated to the catheters inserted into the subclavian vein; however, in the analysis among pediatric patients, higher rates of infection were associated with femoral insertions. In another study (level IV), there were no significant differences in infection rates between central venous catheters and central venous catheters peripherally inserted. This type of catheter may be a safe and effective alternative for burn patients. The limited number of studies selected for this review demonstrates the need to conduct scientific researches related to the theme. In the nursing field, future researches on techniques and covers for the dressing of the site of insertion of the venous catheter inserted near or through the burn are essential, as often the insertion in this site is inevitable. New technologies should also be evaluated, such as CCIP, so that its use is scientifically justified.
33

Reprocessamento de cateteres de angiografia cardiovascular após uso clínico e contaminados artificialmente: avaliação da eficácia da limpeza e da esterilização. / Reprocessing of cardiovascular angiography catheter after clinical use and artificial soil: evaluation of the efficaccy of the cleaning and sterilization.

Ribeiro, Silma Maria Cunha Pinheiro 22 May 2006 (has links)
A prática assistencial na área da saúde implica situações de risco, os quais podem ser maximizados, minimizados ou projetados no julgamento à luz da fundamentação científica. O reprocessamento de materiais de uso único é uma prática que, a cada dia, tem exigido esforços dos profissionais de saúde no sentido de buscar e produzir evidências que auxiliem no processo de tomada de decisão em relação à não-realização ou sob que condições podem ser executadas. O objetivo geral deste estudo foi avaliar a aplicação de diferentes processos de limpeza e a esterilização em óxido de etileno a 100% nos cateteres de angiografia cardiovascular com vista à determinação da capacidade de redução da carga microbiana e do resíduo orgânico neles antes e após a utilização pelo paciente, assim como em situações de simulação com testes desafio. Trata-se de pesquisa experimental, aplicada, comparativa e controlada realizado no Research Centre do Saint Boniface General Hospital filiado à University of Manitoba, localizada em Winnipeg no Canadá. Os cateteres foram utilizados uma única vez por pacientes submetidos a angiografia coronariana e à análise de resíduos orgânicos (hemoglobina, carboidrato, proteína e endotoxina) por meio de testes bioquímicos diretos e indiretos utilizando a técnica de espectrofotometria. A carga microbiana foi avaliada por meio da realização de cultura microbiológica por método indireto. Esses experimentos foram realizados em quatro etapas, sendo a primeira imediatamente após o uso dos cateteres para determinação da sujidade basal; a segunda, após o uso pelo paciente e limpeza do cateter por diferentes métodos; a terceira, após o uso pelo paciente, de inoculação de sujidade artificial e limpeza por diferentes métodos e a quarta, após o uso pelo paciente, teste desafio, limpeza e esterilização simulando-se cinco reusos. Foram utilizadas técnicas de estatística descritiva e analítica por meio de testes estatísticos paramétricos (análise de variância) e, quando necessário, testes não paramétricos (Kruskall-Wallis). Em todas as análises estatísticas, foram considerados testes bilaterais com um nível de significância estatística de 5% ou 0,05 e o intervalo de confiança estabelecido foi de 95%. O resultado positivo em qualquer um dos testes de detecção de resíduo orgânico e microbiológico foi indicativo de ineficácia do método de limpeza testado. As unidades amostrais foram submetidas aos seguintes métodos de limpeza: limpeza manual com detergente enzimático com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada; limpeza manual com detergente contendo peróxido de hidrogênio com enxágüe com água tratada com osmose reversa e esterilizada; limpeza automatizada com detergente enzimático sem enxágüe ou com enxágüe em água tratada com osmose reversa e esterilizada; limpeza sob pressão contínua com detergente contendo peróxido de hidrogênio com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada. Os resultados obtidos neste estudo apontam para a manutenção da carga microbiana antes e após a limpeza dos cateteres. Antes da execução de qualquer método de limpeza dos cateteres, a freqüência de culturas positivas foi de 8,2%, com uma carga microbiana média de 500UFC/unidade. Após a limpeza dos cateteres a freqüência de culturas positivas foi de 8,3% e a carga microbiana média foi de 250UFC/unidade. Os resíduos orgânicos basais detectados nos cateteres apresentavam-se nas seguintes concentrações: 146,3 µg/unidade de hemoglobina, 628,5 µg/unidade de proteína e 7,0 µg/unidade de carboidrato e 38,0 UE/unidade de endotoxina. Após a realização de cinco simulações, a concentração de hemoglobina indireta foi abaixo do limite de detecção do teste, proteína indireta =107,7 µg/unidade, carboidrato indireto= 340,1µg/unidade e endotoxina=5,4UE/unidade. A análise da concentração dos resíduos orgânicos de acordo com os métodos de limpeza demonstrou diferentes níveis de redução. Os métodos de limpeza que utilizaram o detergente contendo peróxido de hidrogênio apresentaram melhor desempenho em relação aos que utilizaram detergentes enzimáticos, sendo que o do método de limpeza sob pressão contínua foi superior aos demais métodos. Os resultados dos resíduos orgânicos dos cateteres que foram submetidos a cinco simulações de reuso mostraram-se inferiores aos valores médios absolutos de uma única simulação, com exceção da concentração média de carboidrato. / The healthy assistance implies in risk, which can be maximized, minimized or projected based on the scientific data. The reprocessing of single used devices is a practice that each day has demanded efforts of the healthcare professionals in order to search and to produce scientific evidences to help them make decision in relation to not reuse or reuse under safety conditions. The objective of this study was to evaluate different cleaning processes and sterilization in ethylene oxide 100% of the angiographic catheters in order to determine the capacity in reducing of the bioburden and the organic residual before and after patient use, as well as in simulated use with soil test. It is an experimental research, comparative and controlled permed in the Research Centre of the Saint Boniface General Hospital affiliated to the University of Manitoba located in Winnipeg, Canada. The catheters had been used only one time for coronariographic exam and submitted to the analysis of organic residues (hemoglobin, carbohydrate, protein and endotoxin) by in situ and destructive test reading by spectrophotometer. The bioburden was evaluated by microbial culture. These experiments had been performed in four phases, being the first immediately after patient use to determine the basaline soil; the second after patient use and cleaning of the catheter by different methods; the third after patient use, soil test inoculation and cleaning by different methods. The fourth phase was performed after patient use and simulated reuse. Descriptive and analytical statistic analysis by parametric statistical tests (variance analysis) or no parametric tests (Kruskall-Wallis) were performed. Had been considered bilateral tests with a significance level < 0,05 and the confidence interval was 95%. It was considered clening failure of the cleaning process any positive results of the detention of organic and microbiological residue. The catheters were submitted to the following cleaning methods: manual washing with enzymatic detergent with tap water or reverse osmosis sterile rinsing; manual washing with hydrogen peroxide detergent rinsing in reverse osmosis sterile water, automated washing with no rinse or reverse osmose sterile water; hydrogen peroxide detergent pumping with tap water or reverse osmosis sterile rinsing . The results gotten in our study showed the maintenance of the bioburden before and after the cleaning of the catheters. In the baseline phase 8,2% of the cultures were positive cultures and the microbial load was 500CFU/device. After cleaning it was 8,3% and the average microbial load was 250 CFU/device. The baseline organic residues data were hemoglobin 146,3µg/device, protein 628,5 µg/device, carbohydrate 7,0µg/device and endotoxin 38,0EU/device. After five simulated use, the indirect hemoglobin concentration was lower of the test limit of detention, protein = 107,7 µg/device, carbohydrate = 340,1µg/device and endotoxin=5,4EU/device. The organic residual analysis according the cleaning methods found different levels of reduction. The cleaning methods that had used a hydrogen peroxide detergent showed better performance relating the enzymatic detergents methods, as well as hydrogen peroxide detergent pumping with reverse osmosis sterile rinsing was the best method. After simulated use phase the organic residue showed lower concentration, excepted the carbohydrate level.
34

Reprocessamento de cateteres de angiografia cardiovascular após uso clínico e contaminados artificialmente: avaliação da eficácia da limpeza e da esterilização. / Reprocessing of cardiovascular angiography catheter after clinical use and artificial soil: evaluation of the efficaccy of the cleaning and sterilization.

Silma Maria Cunha Pinheiro Ribeiro 22 May 2006 (has links)
A prática assistencial na área da saúde implica situações de risco, os quais podem ser maximizados, minimizados ou projetados no julgamento à luz da fundamentação científica. O reprocessamento de materiais de uso único é uma prática que, a cada dia, tem exigido esforços dos profissionais de saúde no sentido de buscar e produzir evidências que auxiliem no processo de tomada de decisão em relação à não-realização ou sob que condições podem ser executadas. O objetivo geral deste estudo foi avaliar a aplicação de diferentes processos de limpeza e a esterilização em óxido de etileno a 100% nos cateteres de angiografia cardiovascular com vista à determinação da capacidade de redução da carga microbiana e do resíduo orgânico neles antes e após a utilização pelo paciente, assim como em situações de simulação com testes desafio. Trata-se de pesquisa experimental, aplicada, comparativa e controlada realizado no Research Centre do Saint Boniface General Hospital filiado à University of Manitoba, localizada em Winnipeg no Canadá. Os cateteres foram utilizados uma única vez por pacientes submetidos a angiografia coronariana e à análise de resíduos orgânicos (hemoglobina, carboidrato, proteína e endotoxina) por meio de testes bioquímicos diretos e indiretos utilizando a técnica de espectrofotometria. A carga microbiana foi avaliada por meio da realização de cultura microbiológica por método indireto. Esses experimentos foram realizados em quatro etapas, sendo a primeira imediatamente após o uso dos cateteres para determinação da sujidade basal; a segunda, após o uso pelo paciente e limpeza do cateter por diferentes métodos; a terceira, após o uso pelo paciente, de inoculação de sujidade artificial e limpeza por diferentes métodos e a quarta, após o uso pelo paciente, teste desafio, limpeza e esterilização simulando-se cinco reusos. Foram utilizadas técnicas de estatística descritiva e analítica por meio de testes estatísticos paramétricos (análise de variância) e, quando necessário, testes não paramétricos (Kruskall-Wallis). Em todas as análises estatísticas, foram considerados testes bilaterais com um nível de significância estatística de 5% ou 0,05 e o intervalo de confiança estabelecido foi de 95%. O resultado positivo em qualquer um dos testes de detecção de resíduo orgânico e microbiológico foi indicativo de ineficácia do método de limpeza testado. As unidades amostrais foram submetidas aos seguintes métodos de limpeza: limpeza manual com detergente enzimático com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada; limpeza manual com detergente contendo peróxido de hidrogênio com enxágüe com água tratada com osmose reversa e esterilizada; limpeza automatizada com detergente enzimático sem enxágüe ou com enxágüe em água tratada com osmose reversa e esterilizada; limpeza sob pressão contínua com detergente contendo peróxido de hidrogênio com enxágüe em água de torneira ou água tratada com osmose reversa e esterilizada. Os resultados obtidos neste estudo apontam para a manutenção da carga microbiana antes e após a limpeza dos cateteres. Antes da execução de qualquer método de limpeza dos cateteres, a freqüência de culturas positivas foi de 8,2%, com uma carga microbiana média de 500UFC/unidade. Após a limpeza dos cateteres a freqüência de culturas positivas foi de 8,3% e a carga microbiana média foi de 250UFC/unidade. Os resíduos orgânicos basais detectados nos cateteres apresentavam-se nas seguintes concentrações: 146,3 µg/unidade de hemoglobina, 628,5 µg/unidade de proteína e 7,0 µg/unidade de carboidrato e 38,0 UE/unidade de endotoxina. Após a realização de cinco simulações, a concentração de hemoglobina indireta foi abaixo do limite de detecção do teste, proteína indireta =107,7 µg/unidade, carboidrato indireto= 340,1µg/unidade e endotoxina=5,4UE/unidade. A análise da concentração dos resíduos orgânicos de acordo com os métodos de limpeza demonstrou diferentes níveis de redução. Os métodos de limpeza que utilizaram o detergente contendo peróxido de hidrogênio apresentaram melhor desempenho em relação aos que utilizaram detergentes enzimáticos, sendo que o do método de limpeza sob pressão contínua foi superior aos demais métodos. Os resultados dos resíduos orgânicos dos cateteres que foram submetidos a cinco simulações de reuso mostraram-se inferiores aos valores médios absolutos de uma única simulação, com exceção da concentração média de carboidrato. / The healthy assistance implies in risk, which can be maximized, minimized or projected based on the scientific data. The reprocessing of single used devices is a practice that each day has demanded efforts of the healthcare professionals in order to search and to produce scientific evidences to help them make decision in relation to not reuse or reuse under safety conditions. The objective of this study was to evaluate different cleaning processes and sterilization in ethylene oxide 100% of the angiographic catheters in order to determine the capacity in reducing of the bioburden and the organic residual before and after patient use, as well as in simulated use with soil test. It is an experimental research, comparative and controlled permed in the Research Centre of the Saint Boniface General Hospital affiliated to the University of Manitoba located in Winnipeg, Canada. The catheters had been used only one time for coronariographic exam and submitted to the analysis of organic residues (hemoglobin, carbohydrate, protein and endotoxin) by in situ and destructive test reading by spectrophotometer. The bioburden was evaluated by microbial culture. These experiments had been performed in four phases, being the first immediately after patient use to determine the basaline soil; the second after patient use and cleaning of the catheter by different methods; the third after patient use, soil test inoculation and cleaning by different methods. The fourth phase was performed after patient use and simulated reuse. Descriptive and analytical statistic analysis by parametric statistical tests (variance analysis) or no parametric tests (Kruskall-Wallis) were performed. Had been considered bilateral tests with a significance level < 0,05 and the confidence interval was 95%. It was considered clening failure of the cleaning process any positive results of the detention of organic and microbiological residue. The catheters were submitted to the following cleaning methods: manual washing with enzymatic detergent with tap water or reverse osmosis sterile rinsing; manual washing with hydrogen peroxide detergent rinsing in reverse osmosis sterile water, automated washing with no rinse or reverse osmose sterile water; hydrogen peroxide detergent pumping with tap water or reverse osmosis sterile rinsing . The results gotten in our study showed the maintenance of the bioburden before and after the cleaning of the catheters. In the baseline phase 8,2% of the cultures were positive cultures and the microbial load was 500CFU/device. After cleaning it was 8,3% and the average microbial load was 250 CFU/device. The baseline organic residues data were hemoglobin 146,3µg/device, protein 628,5 µg/device, carbohydrate 7,0µg/device and endotoxin 38,0EU/device. After five simulated use, the indirect hemoglobin concentration was lower of the test limit of detention, protein = 107,7 µg/device, carbohydrate = 340,1µg/device and endotoxin=5,4EU/device. The organic residual analysis according the cleaning methods found different levels of reduction. The cleaning methods that had used a hydrogen peroxide detergent showed better performance relating the enzymatic detergents methods, as well as hydrogen peroxide detergent pumping with reverse osmosis sterile rinsing was the best method. After simulated use phase the organic residue showed lower concentration, excepted the carbohydrate level.
35

Influência da posição do orifício de saída e do tipo da ponta do cateter sobre o risco de complicações mecânicas e infecciosas e sobrevida da técnica em pacientes em diálise peritoneal /

Banin, Vanessa Burgugi January 2017 (has links)
Orientador: Pasqual Barretti / Resumo: Introdução: As complicações mecânicas e infecciosas associadas ao cateter de dialise peritoneal representam as principais causas de falência da técnica. Tais complicações podem estar associadas às configurações intra e extraperitoneal do cateter. Objetivo: comparar complicações mecânicas e infecciosas, além de sobrevida da técnica entre cateteres de Tenckhoff implantados com Orifício de Saída (OS) voltado para baixo e OS voltado para cima e cateteres de Swan Neck (ponta reta e ponta coil). Metodologia: estudo prospectivo randomizado que comparou complicações mecânicas (translocações) e infecciosas (peritonites e infecções de orifício de saída) entre cateteres divididos de maneira randomizada em quatro grupos: Tenkhoff OS baixo, Tenckhoff OS cima, Swan Neck ponta reta e Swan Neck ponta coil. Os grupos foram seguidos pelo período de um ano. O implante foi realizado pela equipe da Nefrologia utilizando a técnica de Seldinger. Resultados: no período de agosto de 2013 a fevereiro de 2016 foram implantados 107 cateteres em 96 pacientes. As características clinicas e demográficas foram semelhantes entre os pacientes nos quatro grupos. A análise da curva de sobrevida pelo método de Kaplan-Meier não mostrou diferenças para o tempo livre do primeiro episódio de infecção de OS (p=0,19) ou peritonite (p=0,29) entre os quatro grupos. Observamos no entanto, menor tempo livre até o primeiro episódio de translocação (p=0,03), menor sobrevida do cateter (p=0,001) e menor sobrevida da técnica ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Background: The mechanical and infectious complications associated with the peritoneal dialysis catheter represent the main causes of technique failure. Such complications may be associated with the intra- and extra-peritoneal configurations of the catheter. Purpose: The objectives of this study were to compare infectious and mechanical complications and technique survival among four randomized groups of PD catheters: straight Tenckhoff catheters implanted with downward Exit Site (ES), straight Tenckhoff implanted with upward ES, Swan-Neck coil tip and Swan-Neck straight tip. Methods: A prospective randomized trial comparing mechanical (translocations) and infectious (peritonitis and exit-site infection) complications between catheters randomly divided into four groups: Tenkhoff downward ES, Tenckhoff upward ES, Swan Neck straight tip and Swan Neck coil tip. The four groups were followed for one year. The implant was performed by the Nephrology team using the Seldinger technique. Results: In the period from August 2013 to February 2016, 107 catheters were implanted in 96 patients. The baseline demographics characteristics were similar among the groups. Analysis of the Kaplan-Meier survival curve showed no difference in the free time of the first episode of ES infection (p = 0.19) or peritonitis (p = 0.29) among the four groups. We observed, however, less free time for the first episode of translocation (p = 0.03), lower catheter survival (p = 0.001) and lower technique survi... (Complete abstract click electronic access below) / Doutor
36

Influência da posição do orifício de saída e do tipo da ponta do cateter sobre o risco de complicações mecânicas e infecciosas e sobrevida da técnica em pacientes em diálise peritoneal / Influence of the position of the exit site and the type of catheter tip on the risk of mechanical and infectious complications and survival of the technique in patients on peritoneal dialysis

Banin, Vanessa Burgugi [UNESP] 30 May 2017 (has links)
Submitted by Vanessa Burgugi Banin null (vanessa_banin@yahoo.com.br) on 2017-06-11T19:47:04Z No. of bitstreams: 1 Tese Doutorado Vanessa B Banin.pdf: 2100486 bytes, checksum: c9614d685e65624e0fd677fc24e44a8d (MD5) / Approved for entry into archive by Luiz Galeffi (luizgaleffi@gmail.com) on 2017-06-13T14:48:58Z (GMT) No. of bitstreams: 1 banin_vb_dr_bot.pdf: 2100486 bytes, checksum: c9614d685e65624e0fd677fc24e44a8d (MD5) / Made available in DSpace on 2017-06-13T14:48:58Z (GMT). No. of bitstreams: 1 banin_vb_dr_bot.pdf: 2100486 bytes, checksum: c9614d685e65624e0fd677fc24e44a8d (MD5) Previous issue date: 2017-05-30 / Introdução: As complicações mecânicas e infecciosas associadas ao cateter de dialise peritoneal representam as principais causas de falência da técnica. Tais complicações podem estar associadas às configurações intra e extraperitoneal do cateter. Objetivo: comparar complicações mecânicas e infecciosas, além de sobrevida da técnica entre cateteres de Tenckhoff implantados com Orifício de Saída (OS) voltado para baixo e OS voltado para cima e cateteres de Swan Neck (ponta reta e ponta coil). Metodologia: estudo prospectivo randomizado que comparou complicações mecânicas (translocações) e infecciosas (peritonites e infecções de orifício de saída) entre cateteres divididos de maneira randomizada em quatro grupos: Tenkhoff OS baixo, Tenckhoff OS cima, Swan Neck ponta reta e Swan Neck ponta coil. Os grupos foram seguidos pelo período de um ano. O implante foi realizado pela equipe da Nefrologia utilizando a técnica de Seldinger. Resultados: no período de agosto de 2013 a fevereiro de 2016 foram implantados 107 cateteres em 96 pacientes. As características clinicas e demográficas foram semelhantes entre os pacientes nos quatro grupos. A análise da curva de sobrevida pelo método de Kaplan-Meier não mostrou diferenças para o tempo livre do primeiro episódio de infecção de OS (p=0,19) ou peritonite (p=0,29) entre os quatro grupos. Observamos no entanto, menor tempo livre até o primeiro episódio de translocação (p=0,03), menor sobrevida do cateter (p=0,001) e menor sobrevida da técnica (p=0,02) no grupo Tenckhoff OS baixo. A análise múltipla mostrou que o fator associado com falência do cateter foi a presença de translocações. Em um segundo modelo, quando excluído translocações, o cateter Tenckhoff OS baixo se associou com maior risco de falência do cateter. Conclusão: o cateter de Tenckhoff reto com OS voltado para baixo foi associado com menor tempo livre até o primeiro episódio de translocação, além de menor sobrevida do cateter e da técnica. É provável que a atuação da força de resiliência possa ter sido responsável pelos resultados observados nesse estudo. / Background: The mechanical and infectious complications associated with the peritoneal dialysis catheter represent the main causes of technique failure. Such complications may be associated with the intra- and extra-peritoneal configurations of the catheter. Purpose: The objectives of this study were to compare infectious and mechanical complications and technique survival among four randomized groups of PD catheters: straight Tenckhoff catheters implanted with downward Exit Site (ES), straight Tenckhoff implanted with upward ES, Swan-Neck coil tip and Swan-Neck straight tip. Methods: A prospective randomized trial comparing mechanical (translocations) and infectious (peritonitis and exit-site infection) complications between catheters randomly divided into four groups: Tenkhoff downward ES, Tenckhoff upward ES, Swan Neck straight tip and Swan Neck coil tip. The four groups were followed for one year. The implant was performed by the Nephrology team using the Seldinger technique. Results: In the period from August 2013 to February 2016, 107 catheters were implanted in 96 patients. The baseline demographics characteristics were similar among the groups. Analysis of the Kaplan-Meier survival curve showed no difference in the free time of the first episode of ES infection (p = 0.19) or peritonitis (p = 0.29) among the four groups. We observed, however, less free time for the first episode of translocation (p = 0.03), lower catheter survival (p = 0.001) and lower technique survival (p = 0.02) in the Tenckhoff downward ES group. Multiple analysis showed that the factor associated with catheter failure was the presence of translocations. When we excluded translocations from the model the Tenckhoff downward ES was associated with catheter failure. Conclusions: Straight Tenckhoff catheter implanted employing donward tunnel-tract and ES direction is associated with less free time until the first translocation episode, lower catheter and technique survival. It is likely that the performance of resilience force may have been responsible for the results observed in this study.
37

Colonização de cateteres venosos centrais por biofilme microbiano /

Storti, Anisio. January 2006 (has links)
Resumo: Os cateteres venosos centrais são muito usados nas Unidades de Terapia Intensiva (UTIs). O seu uso está freqüentemente associado a complicações incluindo infecções fatais. Durante o período de janeiro de 2004 a janeiro de 2005, foram analisadas 118 pontas de cateteres e 42 amostras de sangue provenientes de 100 pacientes hospitalizados em Unidade de Terapia Intensiva de um hospital da região Noroeste do estado de São Paulo. O objetivo deste estudo foi analisar, por meio de cultura e microscopia eletrônica de varredura, a colonização do cateter intravenoso central de vialon Intracath de lúmem único. Para detectar a produção de slime dos microrganismos isolados foi usado o método de Christensen et al., (1985) e o perfil de sensibilidade aos antimicrobianos de acordo com o (NCCLS-M2-A7-2000). Das 118 pontas de cateteres estudadas pelo método semi-quantitativo, 34 (28,8%) estavam colonizadas (d15 UFC/placa) em que foram isolados 55 microrganismos. Desses, 32 (58,2%) foram classificados como Gram-positivos com freqüência maior para 15 (27,3%) Staphylococcus aureus, seis (10,9%) Staphylococcus epidermidis; 19 (34,5%) classificados como Gram-negativos com freqüência maior para seis (10,9%) Acinetobacter baumannii, três (5,4%) Pseudomonas aeruginosa, Enterobacter aerogenes respectivamente e ainda quatro (7,3%) classificadas como leveduras sendo duas (3,6%) Candida albicans e duas (3,6%) Candida parapsilosis...(Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The aim of the present study was to evaluate the hepatotoxicity, pharmacokinetic parameters and biotransformation of isoniazid when rats were treated with isoniazid (INH); rifampicin (RMP); and INH + RMP. Daily doses of the tuberculostatic drugs were administrated intragastrically to the animals (Wistar rats) for one period of 21 days as follow: sterile water (group I, control); INH (100mg/Kg) (group II), RMP (100mg/Kg) (group III); INH (100mg/Kg) + RMP (100mg/Kg) (group IV). The serum levels of the biomarkers aspartate aminotransferase (AST) and alanine aminotransferase (ALT) were determined before the administration of the drugs (basal) and after the 21 days treatments. On day 21, blood samples were obtained before and 15þ; 30þ; 45þ; 60þ; 1,5; 3h; 6h; 12h and 24 hours after the dose. (five animals for each point). The blood samples were deproteinized with 10% trichloroacetic acid, derivatized by 1% cinnamaldehyde and analyzed by liquid chromatograph. For the determination of the acetylated metabolites acetylisoniazid (AcINH) and acetylhydrazine (AcHz) a previous hydrolysis with 6 M hydrochloride acid was performed. The results are presented as mean and SEM. ...(Complete abstract, click electronic address below). / Orientador: Elisabeth Loshchagin Pizzolitto / Coorientador: Antonio Carlos Pizzolitto / Banca: Taís Maria Bauab / Banca: Sérgio Aparecido Torres / Banca: Sergio Eduardo Longo Fracalanza / Banca: Beatriz Ernestina Cabilio Guth / Doutor
38

AvaliaÃÃo das prÃticas de prevenÃÃo e controle de infecÃÃo relacionadas ao cateter venoso central: indicadores clÃnicos / Evaluation of practices for the prevention and control of central venous catheter-related infection: clinical indicators

Francisca Jane Gomes de Oliveira 19 December 2013 (has links)
nÃo hà / Os serviÃos de saÃde vÃm desenvolvendo aÃÃes e programas visando à qualificaÃÃo de seus processos de trabalho, com intuito de reduzir, prevenir e eliminar deficiÃncias da qualidade e que tambÃm atendam Ãs necessidades e expectativas dos usuÃrios. Diferentes estratÃgias de avaliaÃÃes das prÃticas em saÃde tÃm sido adotadas, permitindo a identificaÃÃo das condiÃÃes em que as prÃticas assistenciais sÃo executadas. As infecÃÃes hospitalares constituem risco significativo à saÃde dos usuÃrios, e dentre estas, a infecÃÃo de corrente sanguÃnea relacionada ao cateter venoso central, dada a mortalidade a ela associada, especialmente quando acomete pacientes graves, internados em Unidade de Terapia Intensiva (UTI). Assim, este estudo objetivou avaliar a conformidade e nÃo conformidade das prÃticas de prevenÃÃo de infecÃÃo de corrente sanguÃnea relacionada ao cateter venoso central de curta permanÃncia (ICS-ACVC), por meio de indicadores clÃnicos em uma Unidade de Terapia Intensiva. Trata-se de um estudo observacional, seccional, com abordagem quantitativa, estruturado a partir do âmanual de avaliaÃÃo das prÃticas de controle e prevenÃÃo de infecÃÃo hospitalarâ, realizado em um hospital da rede privada da cidade de Fortaleza/CearÃ. O universo do estudo foi composto pelas oportunidades de avaliaÃÃo das prÃticas selecionadas, realizadas pelos profissionais de saÃde (mÃdicos e profissionais de enfermagem) em pacientes internados na Unidade de Terapia Intensiva da instituiÃÃo e que passaram pelo procedimento de inserÃÃo do cateter venoso central de curta permanÃncia. A amostra baseou-se na conformidade esperada de 80%, com 2064 avaliaÃÃes distribuÃdas entre as prÃticas selecionadas, realizadas por meio da observaÃÃo direta ou registro em prontuÃrios. De acordo com os resultados encontrados, o indicador CSPI apresenta maior Ãndice de conformidade geral (62,5%), em seguida o indicador CSCM apresenta conformidade geral inferior à ideal, com apenas 45%, entretanto, quando analisado cada item que compÃe este indicador, pode-se observar que essa inferioridade deve-se principalmente à nÃo realizaÃÃo da prÃticas de desinfecÃÃo de hubs e conectores com clorexidine 0,5% (17,5%) e troca de equipos e transdutores conforme recomendaÃÃo (13,5%). O indicador CSQI apresentou conformidade geral baixa (12,5%), devido à nÃo conformidade de algumas prÃticas como: uso de campo estÃril ampliado no momento de instalaÃÃo do cateter (30%) e o uso de antissÃptico de veÃculo alcoÃlico para preparo da pele antes da punÃÃo (37,5%). Jà o indicador HMSEL apresentou Ãndice de conformidade geral nulo. Conclui-se que, embora a avaliaÃÃo das prÃticas de registro de indicaÃÃo, tempo de permanÃncia, inserÃÃo percutÃnea, presenÃa de curativo oclusivo apÃs inserÃÃo do cateter, registro e periodicidade da troca do curativo do cateter tenham atingido conformidade similar ou superior à esperada de 80%, as demais prÃticas precisam de uma nova elaboraÃÃo de estratÃgias que assegurem a adesÃo duradoura das prÃticas de controle e prevenÃÃo de ICS-ACVC, associada à anÃlise contÃnua de condiÃÃes de trabalho e disponibilidade de material. / Health services has developed actions and programmes targeting the qualification of its work processes, in order to reduce, prevent and elimiinar quality deficiencies and which also meet the needs and expectations of users. Different evaluations of strategies in health practices has been adopted, allowing the identification of the conditions under which assists practices are performed. Hospital-acquired infections pose significant risk to the health of users, and among these, bloodstream infection central venous catheter-related, given the associated mortality, especially when it involves serious patients admitted to intensive care unit (ICU). Thus, this study aimed to evaluate compliance and non-compliance of practices for the prevention of infection of the bloodstream of central venous catheter related sojourn (ICS-ACVC), through clinical indicators in a therapy unit Intensive. This is an observational study, sectional, with quantitative approach, structured from the "Handbook of practical assessment of hospital infection control and prevention", held in a private network hospital of Fortaleza/CearÃ. The universe of study was composed of selected practices assessment opportunities, conducted by health professionals (doctors and nursing professionals) in patients hospitalized in the intensive care unit of the institution and who went through the procedure of central venous catheter insertion of sojourn. The sample was based on expected 80% compliance with 2064 evaluations distributed among selected practices, carried out by means of direct observation or record in charts. According to the results, the CSPI, indicator presents greater overall compliance index (62.5%), then the CSCM indicator, presents general compliance less than ideal, with only 45%, however when analysed each item that makes up this indicator it can be observed that this inferiority is mainly the non-realization of the practice of disinfection of hubs and connectors with 0.5% (17.5%) also and exchange of equipment and transducers as recommendation (13.5%). The CSQI indicator, presented general compliance low (12.5%), due to non-compliance of some practices such as: use of sterile field expanded at the time of installation of the catheter (30%) and the use of antiseptic of vehicle alcohol for skin preparation before the LP (37.5%). Already the HMSEL indicator presented general compliance index null. It is concluded that, although the evaluation of registration practices, on-call time, percutaneous insertion, presence of Occlusive dressing after catheter insertion, registry and periodicity curative catheter Exchange have reached compliance similar to or greater than 80% expected, other practices need a new elaboration of strategies that ensure lasting adhesion control practices and prevention of ICS-ACVC, associated with the analysis continues working conditions and availability of material.
39

Sítio de inserção do cateter venoso no paciente queimado e ocorrência de infecção: revisão sistemática de literatura / Sites of venous catheter insertion in burn patients and occurrence of infection: systematic review of the literature.

Caroline Lopes Ciofi Silva 05 November 2012 (has links)
Pacientes queimados possuem alto risco de infecção e desenvolvimento de sepse relacionado a diversos fatores, entre eles a presença de dispositivos invasivos, como os cateteres venosos indispensáveis para o tratamento desses pacientes. O objetivo desse estudo foi identificar e avaliar as evidências disponíveis na literatura, por meio de revisão sistemática, sobre possível associação entre o sítio de inserção do cateter venoso em pacientes queimados e o aumento da ocorrência de infecção relacionada ao cateter. Analisaram-se as seguintes bases de dados: MEDLINE, LILACS, CINAHL, EMBASE, Web of Science e The Cochrane Library. Utilizaram-se os descritores controlados e não-controlados adaptados para cada base de dados e, para a combinação desses, utilizou-se o operador boleano AND. As buscas ocorreram entre os meses de outubro e dezembro de 2011. Após leitura dos títulos, resumos e textos na íntegra, considerando-se os critérios de inclusão e exclusão previamente definidos, selecionou-se nove estudos. Utilizou-se um roteiro elaborado e validado para coleta dos dados e avaliação crítica dos estudos. A síntese dos dados ocorreu de forma descritiva. Os estudos foram classificados segundo duas categorias temáticas: infecção relacionada ao cateter e inserção do cateter através da queimadura ou em área próxima à queimadura; e infecção relacionada ao cateter e sítios anatômicos de inserção do cateter venoso. Na primeira categoria, foram incluídos quatro estudos que compararam a ocorrência de infecção relacionada ao cateter e a distância entre a área queimada e o sítio de inserção do cateter venoso. Classificaram-se todos os estudos como nível de evidência IV. Em dois deles, os resultados mostraram diferenças não significantes das taxas de infecção. Em outros dois estudos, os resultados mostraram diferenças significantes entre as taxas de infecção, sendo maiores para os cateteres inseridos próximos ou através da lesão. Na segunda categoria temática foram incluídos cinco estudos. Em dois dos estudos (nível de evidência IV), os cateteres inseridos na veia femoral apresentaram maiores taxas de sepse relacionada ao cateter. Em outro estudo (nível de evidência IV), ao analisar pacientes adultos e pediátricos, maiores taxas de infecção estavam associadas aos cateteres inseridos na veia subclávia; porém, na análise entre os pacientes pediátricos, maiores taxas de infecção estavam associadas às inserções na femoral. Em outro estudo (nível IV), não foram identificadas diferenças significantes nas taxas de infecção entre cateteres venosos centrais e cateteres venosos centrais de inserção periférica. Esse tipo de cateter pode ser uma alternativa segura e efetiva para pacientes queimados. O número limitado de estudos selecionados para essa revisão demonstra a necessidade de realização de pesquisas científicas relacionadas ao tema. Na área da enfermagem, investigações futuras sobre técnicas e coberturas para o curativo do sítio de inserção do cateter venoso inserido próximo ou através da queimadura são fundamentais, já que muitas vezes a inserção nesse sítio é inevitável. Novas tecnologias também devem ser avaliadas, como o CCIP, para que seu uso esteja fundamentado cientificamente. / Burn patients are at high risk of infection and development of sepsis related to several factors, including the presence of invasive devices such as venous catheters needed to treat these patients. This study aimed to identify and evaluate the evidence available in the literature through systematic review on the possible association between the sites of venous catheter insertion in burn patients and the increasing of occurrence of catheter-related infection. The following databases were analyzed: MEDLINE, LILACS, CINAHL, EMBASE, Web of Science and The Cochrane Library. It was used controlled and uncontrolled descriptors adapted for each database and, for combining them, the Boolean operator AND. The searches occurred between October and December 2011. After reading the titles, abstracts and full texts, and considering the inclusion and exclusion criteria previously defined, nine studies were selected. A script developed and validated for data collection and critical evaluation of the studies was used. Descriptive data synthesis was performed. Studies were classified according to two thematic categories: catheter-related infection and catheter insertion through burn or near the burn area and catheter- related infection and anatomical sites of venous catheter insertion. In the first category, four studies that compared the occurrence of catheter-related infection and the distance between the burn area and the site of insertion of the venous catheter were included. All studies were classified as evidence level IV. In two of them, the results showed no significant differences in infection rates. In two other studies, the results showed significant differences in infection rates, being higher for catheters inserted near or through the lesion. The second thematic category included five studies. In two of the studies (evidence level IV), the catheters inserted in the femoral vein had higher rates of catheter-related sepsis. In another study (evidence level IV), when analyzing adult and pediatric patients, higher rates of infection were associated to the catheters inserted into the subclavian vein; however, in the analysis among pediatric patients, higher rates of infection were associated with femoral insertions. In another study (level IV), there were no significant differences in infection rates between central venous catheters and central venous catheters peripherally inserted. This type of catheter may be a safe and effective alternative for burn patients. The limited number of studies selected for this review demonstrates the need to conduct scientific researches related to the theme. In the nursing field, future researches on techniques and covers for the dressing of the site of insertion of the venous catheter inserted near or through the burn are essential, as often the insertion in this site is inevitable. New technologies should also be evaluated, such as CCIP, so that its use is scientifically justified.
40

Development of Nursing Staff Education for Central Line Maintenance

Farley, Doreen Lynn 01 January 2019 (has links)
Patients with cancer who receive bone marrow transplants (BMT) are at increased risk for central line-associated blood stream infections (CLABSI), a serious complication leading to increased costs, length of stay, and even death. Recognition of an increased CLABSI rate at one BMT unit in the southwestern United States prompted development of an evidence-based staff development education program to improve nurses’ knowledge of central line maintenance and CLABSI prevention practices. Guided by Lewin change theory, the program was developed based on a nurse-led analysis and synthesis of the evidence, and a formative evaluation of the educational program conducted by a 3-member expert panel made up of the BMT director, a BMT clinical nurse specialist and vascular access team member. The review confirmed the lack of standardized evidence-based guidelines for central venous catheter care, that any patient who has a central line is at risk for CLABSI, and BMT patients are at particular risk due to frequency of catheter manipulation. Findings reinforced the need for the recommendations to educate nurses in BMT settings on evidence-based central line practices, evaluate knowledge gained, and audit practice techniques post education. The social change implication of this DNP project will be the potential decrease in healthcare costs, length of stay, and mortality associated with central line infections when nursing staff are provided an educational program that aims to improve their knowledge and skills of evidence-based central line care and CLABSI prevention practices.