• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Development of a gamma-ray beam profile monitor for the high-intensity gamma-ray source

Regier, Thomas Zachary 29 October 2003
Beam profile monitors provide position and ux distribution information to facilitate the configuration of an experimental apparatus and are an important component of any accelerator facilities beam diagnostic system. Nuclear physics experiments typically involve the incidence of high energy particles or gamma-rays on some target material and the detection of the products of the ensuing interactions. Therefore, knowing the profile of the incident radiation beam is desirable. To address the need for a profile monitor for the High-Intensity Gamma-Ray Source, development of a CCD-based gamma-ray beam profiler was undertaken. The profiler consisted of plastic scintillator, a lens system and a Starlight Express MX5 CCD camera, all contained within a light tight box. The scintillation pattern, created by the interaction between the incident gamma-rays and the scintillator, could be focused onto the CCD. Simulations were used to determine the amount of power that would be absorbed for different beam energies and scintillator thicknesses. The use of a converter material, placed directly against the scintillator to improve power deposition, was also investigated. The system was tested in order to and the camera noise characteristics, the optical resolution and magnification and the systems responsivity to power absorption in the scintillator. Using a 137Cs source, preliminary beam proles were obtained. By combining the results of the testing and simulation, predictions of the required length of exposure were made. It was determined that a beam with a flux of 10^6/s and a diameter of 2.5 cm could be profiled, using 6.0 mm of plastic scintillator and 0.6 mm of iron converter, to within 5% error per 0.64 mm x 0.91 mm resolving unit, in less than 1 minute.
2

Development of a gamma-ray beam profile monitor for the high-intensity gamma-ray source

Regier, Thomas Zachary 29 October 2003 (has links)
Beam profile monitors provide position and ux distribution information to facilitate the configuration of an experimental apparatus and are an important component of any accelerator facilities beam diagnostic system. Nuclear physics experiments typically involve the incidence of high energy particles or gamma-rays on some target material and the detection of the products of the ensuing interactions. Therefore, knowing the profile of the incident radiation beam is desirable. To address the need for a profile monitor for the High-Intensity Gamma-Ray Source, development of a CCD-based gamma-ray beam profiler was undertaken. The profiler consisted of plastic scintillator, a lens system and a Starlight Express MX5 CCD camera, all contained within a light tight box. The scintillation pattern, created by the interaction between the incident gamma-rays and the scintillator, could be focused onto the CCD. Simulations were used to determine the amount of power that would be absorbed for different beam energies and scintillator thicknesses. The use of a converter material, placed directly against the scintillator to improve power deposition, was also investigated. The system was tested in order to and the camera noise characteristics, the optical resolution and magnification and the systems responsivity to power absorption in the scintillator. Using a 137Cs source, preliminary beam proles were obtained. By combining the results of the testing and simulation, predictions of the required length of exposure were made. It was determined that a beam with a flux of 10^6/s and a diameter of 2.5 cm could be profiled, using 6.0 mm of plastic scintillator and 0.6 mm of iron converter, to within 5% error per 0.64 mm x 0.91 mm resolving unit, in less than 1 minute.

Page generated in 0.0884 seconds