• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 403
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 410
  • 212
  • 199
  • 156
  • 151
  • 79
  • 69
  • 63
  • 63
  • 57
  • 44
  • 35
  • 35
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
211

Influência da salinidade do fluido na avaliação da compactação e da resistividade elétrica de dois solos /

Yamasaki, Marcia Tiemi. January 2012 (has links)
Orientador: Anna Silvia Palcheco Peixoto / Banca: Vagner Roberto Elis / Banca: George de Paula Bernardes / Resumo: A resistividade elétrica vem sendo somada junto aos estudos de investigação geotécnica devido ao seu apelo ambiental, visto que esta técnica se dá por meio da imposição de um fluxo de corrente elétrica em uma amostra de solo, permitindo-se avaliar as condições geológicas locais por um método não destrutivo. A obtenção dessa medida vem sendo somada aos estudos de investigação geotécnica devido ao seu apelo ambiental, otimizando as amostragens e permitindo a avaliação das condições geológicas locais por meio de um método não destrutivo. Dessa maneira, o objetivo dessa dissertação de mestrado é avaliar, em laboratório, o comportamento da resistividade elétrica variando-se o teor de salinidade no fluido de percolação em dois solos tropicais: um arenoso, sedimentar, característico da região de Bauru, e outro argiloso, resultado do intemperismo do Diabásio, proveniente do município de Piracicaba. As análises foram realizadas utilizando-se resultados, dos ensaios de caracterização, compactação, permeabilidade e curva de retenção. o teor de salinidade do fluido foi considerado, tanto na compactação, como na percolação em três concentrações: água destilada, 250 ppm e 500 ppm de NaCI, além de abastecimento, controlando-se o teor de umidade, a compactação, o índice de vazios e o grau de saturação. Os resultados mostraram-se que a resistividade elétrica tende a ser constante no ramo úmido da curva de compactação e também quando o grau de saturação está acima de 80%. Notou-se também que a curva de resistividade versus sucção pode ser divida em dois trechos: o primeiro corresponde às baixas sucções, com a continuidade da água nos poros e resistividade menores; o segundo trecho, que se inicia na primeira entrada de dar, conduz a um nítido aumento nos valores de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The electrical resitivity of a homogeneous material could be defined as the measurements of the difficult of crossing of the electrical current and it depends of the dimension and type of material. However, when that material is soil, composed by three phases (solid, liquid and gas), this measure is influenced by several factors that could be controlled in laboratory tests. The electrical resistivity has been used geotechnical research studies since this technique improve the sampling of environmental works and allowing the evaluation of local geological conditions through a non-destructive method. Thus, the goal of the study was evaluate the behavior of electrical resistivity of two tropical soils varying the salinity concentration in the percolation fluid: a sandy sediment, characteristic of the Bauru city; a clayey soil, Weathered of Diabase from Piracicaba City. Results of soil mechanics laboratory tests as characterization tests, compaction, permeability and soil-water retention curve were used in the analyses. In both, compaction and permeability tests, the procedure were carried out varying the fluid salinity: distilled water, water supply; 250ppm and 500ppm of NaCi. The moisture content, compaction energy, void ratio and degree of saturation. The tests results showed the rsistivity values tend to be constant in the wet density curve and when the degree of saturation is above 80%. It was also noted that the curve of resistivity suction could be divided into two segments: the first corresponds to low suctions where there is continuity of water in the porous leading to low resistivity values; the second segment begins in the first air entrance, with discountinuous state of pore-water and sa sharphy increase in the resistivity values. The formation factors (FF) were obtained during the permeability tests: 7,5 to the sandy soil and... (Complete abstract click electronic access below) / Mestre
212

Desenvolvimento do sistema radicular do milheto (Pennisetum americanum L.) em duas classes de solo em densidade e diferentes profundidades da camada compactada /

Santos, Miriam Corrêa dos, 1975- January 2006 (has links)
Orientador: Sérgio Hugo Benez / Banca: Maria Helena Moraes / Banca: Antonio Renan Berchol da Silva / Resumo: O presente estudo objetivou avaliar o efeito da compactação do solo nas características agronômicas do milheto (Pennisetum americanum L., variedade BN-2), em um LATOSSOLO VERMELHO Distrófico (LVd) e NITOSSOLO VERMELHO Distroférrico (NVd). Para tanto o solo foi compactado em função de cinco níveis de densidades do solo, caracterizados pelas densidades 0,4;1,20; 1,30; 1,40; 1,50 Mg m-3 . O experimento foi colocado em condições de céu aberto na Faculdade de Ciências Agronômicas - UNESP, Campus de Botucatu-SP, durante os meses de Novembro de 2004 à Fevereiro de 2005, adotou-se o delineamento fatorial triplo, em esquema fatorial 2 x 3 x 5 e quatro repetições. A unidade experimental (vaso) constituído de um cilindro de PVC rígido, composto pela sobreposição de três anéis, com diâmetro interno de 20 cm, totalizando 30 cm de altura. Os parâmetros analisados foram: comprimento, volume, diâmetro e massa seca das raízes; e também massa seca e comprimento da parte aérea das plantas, adotando-se o esquema fatorial 2 x 3 x 5. Os dados obtidos foram submetidos à análise de variância e posteriormente foi aplicado o teste de comparações múltiplas de Tukey no nível de 5 % de probabilidade para comparação das médias.Os resultados mostraram que o milheto proporcionou maior quantidade de massa seca da parte aérea em ambos os solos, mostrando ter melhor característica para cobertura do solo. O LATOSSOLO VERMELHO Distrófico proporcionou melhor condição de desenvolvimento da planta em estudo, por apresentar menor resistência à penetração das raízes, em todas as camadas compactadas, quando comparado ao NITOSSOLO VERMELHO Distroférrico. O crescimento radicular não alterou o crescimento aéreo da planta. Os resultados mostram que: no LATOSSOLO VERMELHO Distrófico o comprimento radicular teve menor desenvolvimento com o aumento da densidade... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This paper aimed to study the development to root sistem of millet (Pennisetum americanum L.) Within two soil types, classified as Distrofic RED LATOSOIL and Distroferic RED NITOSOIL. According to five density levels of soil compaction, characterized by 0,8; 1,2; 1,3; 1,4 and 1,5Mg.m-3 densities. The experiment was carried out at Faculdade de Ciências Agronômicas - UNESP, Campus de Botucatu-SP, from November 2004 to february 2005, in a randomized factorial triple experimental design with four repetitions and 2x3x5 factorial desing. The pots were assembled with three rings of overlayed PVC tubes, 20cm of inner diameter, summing up 30cm high. Measurement of root length, root volume, root diameter, root dry matter were measured as well as dry matter and length of aerial part of plants, adopt factorial desing 2x3x5. Obtained data were submitted to variance analysis under Tukeyþs test with 5% ofprobality for mean comparison. Results showed that the milhet the highest aumont of dry matter at aerial part in both soils. The Distrophic RED LATOSOIL showed best easy terms to plant development, to present a lower resistance to root penetration, whole depyh to study, compared to Disthopheric RED NOTOSOIL. The root system not to alter aerial part of plant. The results showed that: The Distrophic RED LATOSOIL root system with smalles development with growth density; The soil Distrophic RED LATOSOIL, root system with longer length, rearding to Disthopheric RED NOTOSOIL; with growth to density in both soils showing to have smalles development; The dry matter at aerial part, smalles in density 1,5Mg.m-3 in both soils and all most depth 14 compaction; to accumulate the dry matter at aerial part that... (Complete abstract click electronic access below) / Mestre
213

Variabilidade espacial da resistência mecânica do solo à penetração em áreas mecanizadas de cana-de-açúcar (Saccharum officinarum) /

Ribeiro, Carlos Augusto. January 2010 (has links)
Orientador: Carlos Eduardo Angeli Furlani / Banca: Danilo Cesar Checcio Grotta / Banca: Rouverson Pereira da Silva / Resumo: O uso intensificado de máquinas agrícolas em áreas de cana-de-açúcar contribui para o aumento do estado de compactação do solo e pode ter como consequência a redução de produtividade. O objetivo deste trabalho foi caracterizar a variabilidade espacial da resistência mecânica do solo à penetração (RMSP) em áreas cultivadas com cana-de-açúcar de primeiro a quinto corte, com manejo totalmente mecanizado. As amostras de RMSP foram coletadas a cada 1 cm até a profundidade de 50 cm, na entrefileira e na fileira de plantio, utilizando-se penetrômetro eletrônico georreferenciado. Em cada área experimental foi determinado um grid amostral, sendo cada ponto de ensaio georreferenciado por meio de um receptor GPS acoplado ao penetrômetro. Os dados foram submetidos à análise de estatística descritiva e geoestatística, com o intuito de avaliar o comportamento geral dos dados e a dependência espacial da RMSP. Foram construídos mapas de isolinhas, utilizando o método de krigagem, para identificar áreas com valores de RMSP impeditivos para o desenvolvimento radicular da planta. Constatou-se que a área de primeiro corte não possui valores de RMSP considerados críticos (> 4 MPa) ao desenvolvimento da canade- açúcar, ao passo que áreas com segundo corte em diante apresentaram valores críticos em alguma camada de profundidade / Abstract: The intensified use of agricultural machinery in planting areas of the sugarcane contributes to the increase of the state of soil compaction and may have the effect of reducing productivity. The objective of this work was to study the spatial variability of soil mechanical resistance to penetration (RMSP) in areas cultivated with sugarcane from first to fifth cut, with management fully mechanized. The Samples of RMSP were collected in the between row and row of planting, every 1 cm to a depth of 50 cm, using a penetrometer electronic georeferenced. In each experimental area was given a sample grid, where each point was georeferenced by a GPS receiver attached to the penetrometer. Data were submitted to analysis of descriptive statistics and geostatistics in order to assess the general behavior of the data and the spatial dependence of the RMSP. Maps of isolines were constructed using the kriging method to identify areas with values of RMSP impede the development of the plant root. It was found that the area of the first cut does not have critical values (> 4 MPa) of the RMSP to the development of the sugarcane, while areas with a second cut in front of RMSP showed high values in some layer of depth / Mestre
214

Variabilidade espacial dos atributos físicos e químicos em um gleissolo mecânico sob três áreas no município Arari - MA /

Farias Filho, Marcelino Silva. January 2014 (has links)
Orientador: Célia Regina Paes Bueno / Banca: João Tavares Filho / Banca: Gener Tadeu Pereira / Banca: José Eduardo Corá / Banca: Adeodato Ari Calvacante Salviano / Resumo: Os atributos químicos e físicos dos solos possuem variabilidade espacial natural que pode ser alterada pelo manejo. O entendimento do padrão da distribuição espacial desses atributos é questão-chave a ser considerada para o correto uso dos solos. Este trabalho avaliou a variabilidade dos atributos físicos e químicos em um Gleissolo Melânico Alítico típico sob três áreas no município de Arari - MA. Para realização da pesquisa foram selecionadas três áreas de um hectare em formato regular, com solo utilizado por arroz irrigado e pecuária (área A), pecuária extensiva em vegetação nativa (área B) e arroz irrigado (área C), onde foram coletadas amostras de solo (deformadas e indeformadas) na camada de 0,0-0,20 m, com malha regular de 10 x 10 m, perfazendo 121 amostras por área e um total de 363. As variáveis analisadas por estatística descritiva e geoestatística nas três áreas foram: resistência do solo à penetração, densidade do solo, porosidade (total, macro e microporosidade), areia, silte, argila, pH (CaCl2), C orgânico, K+, Ca+2, Mg+2, P disponível, S, Na+, Al3+, H+Al (acidez potencial), SB (soma de bases), T (capacidade de troca catiônica), V% (saturação por bases) e m% (saturação por alumínio). Os valores foram elevados para a variável resistência do solo à penetração nas três áreas, sendo a área A aquela que teve o maior valor médio. Os atributos físicos apresentaram dependência espacial em todas as áreas, com exceção da areia na área A. A porosidade total teve maior dependência espacial e menor variabilidade / Abstract: The chemical and physical attributes of soils have natural spatial variability that can be changed by management. Understanding the spatial distribution pattern of these attributes is the key issue to be considered for correct soil use. This study evaluated the variability of the physical and chemical properties of an Gleysoil Melanic Alitic typical in three areas in the municipality of Arari - MA. To achievement the survey were selected three areas of one hectare in regular format, with soil used for irrigated rice and livestock (area A), extensive cattle ranching in native vegetation (area B) and irrigated rice (area C), where samples were collected of soil (warped and undeformed) in the 0.0-0.20 m layer, with regular grid of 10 x 10 m, totaling 121 samples per area and a total of 363. The variables analyzed by descriptive statistics and geostatistics in the three areas were: resistance to penetration, density, porosity (total, macro and microporosity), sand, silt, clay, pH (CaCl2), organic C, K+, Ca+ 2, Mg+2, available P, S, Na+, Al3+, H+Al (potential acidity), SB (sum of bases), T (cation exchange capacity), V% (base saturation) m% (saturation aluminum). The values were higher for the resistance variable to penetration in the three areas, being the area A one that had the highest average value. The physical attributes present dependence spatial in all areas, with the exception of the sand in the area A. Total porosity had higher spatial dependence and less variability. The chemical attributes that showed greater dependence spatial were pH and Na. The area ... / Doutor
215

Uma abordagem baseada em redes neurais artificiais para a estimação de densidade de solo /

Nagaoka, Maria Eiko. January 2003 (has links)
Resumo: Este trabalho apresenta a aplicação de um sistema inteligente utilizando redes neurais artificiais para estimar valores de densidade do solo, a partir de parâmetros referentes à resistência do solo à penetração. Foram considerados solos preparados e não preparados, os não preparados foram os seguintes : teor de argila menor que 30 % (solo tipo 1), de 30 a 50 % (solo tipo 2) e maior que 50 % (solo tipo 3). Os preparados foram os seguintes: um com teor de argila menor que 30 % (solo tipo 1) e o outro com teor de argila maior que 50 % (solo tipo 3). O objetivo principal deste trabalho foi implementar diversas redes neurais do tipo perceptron multicamadas, alimentando-as com resistência do solo à penetração, teor de água e teor de argila, tendo como variável de saída a densidade do solo. Cada rede foi treinada variando o número de camadas escondidas e também variando o número de neurônios, de 10 a 40, em cada camada. Para cada arquitetura, a rede foi treinada 10 vezes, escolhendo-se no final do treinamento a arquitetura com menor erro relativo médio e menor variância em relação aos dados de validação. As análises realizadas mostraram que as arquiteturas de rede com apenas uma camada escondida forneceram melhores resultados. Todas as redes tiveram melhor desempenho em solo não preparado do que em solo preparado. A rede de arquitetura de 3 entradas, uma camada escondida com 30 neurônios e 1 saída forneceu excelente resultado para solo não preparado (com teor de argila entre 30 e 50 %). Constatou-se que a rede quando treinada com dados do solo preparado, juntamente com dados do solo não preparado, melhorou os resultados de estimação para o solo preparado, mas piorou para os solos não preparados. Constatou também que a rede quando treinada junto com dados que contém solo solto fornece resultados imprecisos. O mesmo ocorreu para dados com teor de água elevado. / Abstract: This work presents the development of an intelligent system using artificial neural networks to estimate values of soil density. Prepared and non-prepared soils were considered in this work. The non-prepared soils were the following ones: clay content lesser than 30 % (soil type 1), 30 to 50 % (soil type 2) and larger than 50 % (soil type 3). The prepared soils were the following ones: soil with clay content lesser than 30 % (soil type 1) and soil with clay content larger than 50 % (soil type 3). The main objective of this work was to implement several neural networks of type multilayer perceptron, feeding them with data concerning to the soil compaction characteristics. The output computed by the neural network was the respective density of these soils. Each neural network was trained varying both number of hidden layers and number of neurons, which was changed from 10 to 40 neurons in each layer. In each architecture the network was trained 10 times and selected architecture was always that having either the least mean relative error or the least variance in relation to validation data. The carried out analyses showed that the neural architectures having only a hidden layer were those that provided the best results. All neural networks have presented more efficient results for non-prepared soils than prepared soils. The neural network constituted by three inputs and one output, having 30 neurons at hidden layer, has provided excellent results for non-prepared soils (clay content between 30 and 50 %). It was also verified that the neural network when trained with data referent to non-prepared and soils, which were put in the same data set, it became the results referent to prepared soils more efficient, but the results for non-prepared soils become worse. Another observed point was when the network had been trained with data constituted by soft soil... (Complete abstract, click electronic address below). / Orientador: Ivan Nunes da Silva / Coorientador: Kléber Pereira Lanças / Doutor
216

Efeitos da adição da cal hidratada na estabilização de um solo sedimentar para pavimentação urbana na região de Curitiba / Effects of the addition of hydrated lime to stabilize a sedimentary soil for urban paving in the region of Curitiba

Bordignon, Vitor Reinaldo 26 August 2015 (has links)
A pavimentação urbana é de primordial importância para uma cidade, tanto socioeconômica quanto em qualidade de vida. Os pavimentos urbanos não diferentes dos chamados pavimentos rodoviários, são constituídos por um conjunto de camadas horizontais, sobrepostos ao solo, os quais possuem a função principal de suportar as ações induzidas pelos veículos redistribuindo as tensões transmitidas ao solo. Os solos são importantes materiais para a execução de pavimentação, principalmente por fazerem parte da estrutura básica do pavimento e na sua grande maioria se encontrar disponível em abundância, com um custo muito baixo, entretanto, as suas propriedades normalmente não cumprem os requisitos necessários à execução do pavimento. A estabilização de solos para a execução de bases e sub-bases de pavimentos urbanos constitui um aspecto cada vez mais importante no panorama atual, pelo fato de existir sempre a preocupação com o meio ambiente, existindo hoje a clara consciência de que todos os esforços devem ser feitos no sentido de minimizar os efeitos causados pela exploração de jazidas e deposição do material. Neste sentido este trabalho apresenta os efeitos da adição de diferentes proporções da cal para a estabilização de uma amostra de solo sedimentar da região urbana da cidade de Curitiba. Foi selecionada uma quantidade de amostra de solo da região, para o estudo da estabilização com inserção da cal hidratada do tipo (CHIII) em pó. As duas variáveis analisadas no estudo estão relacionadas com os teores da cal misturada ao solo nas porcentagens de 0%, 3%, 6%, 8% e 16%, e os tempos de cura em que estas misturas foram submetidas a (0, 7, 14, 28 e 56 dias). As misturas testadas foram elaboradas a partir de dosagens definidas por dois métodos: um verificando o comportamento químico das amostras, por meio da evolução dos valores de pH, e o segundo analisando o comportamento mecânico através dos valores de RCS. Verificou-se que a estabilização química analisada por meio de adição da cal, proporcionou um aumento médio de RCS na maioria das amostras do solo estudado, em função de algumas características físicas e químicas das mesmas. Para as misturas com 6%, 8% e 16%, da cal aos 28 dias de cura, a média da RCS foi de 0,57 MPa, 1,06 MPa e 2,37 MPa, respectivamente, para o proctor normal, sendo que para o proctor intermediário, com o mesmo período de cura, e nas mesmas porcentagens, os resultados de RCS foram de 0,54 MPa, 1,04 MPa, e 2,71 MPa, respectivamente. De uma forma global, as misturas solo-cal estudadas apresentaram comportamento aceitável pelas normas vigentes para utilização como camadas de sub-base. Contudo, apenas a mistura com 16% da cal, aos 28 dias, é recomendada para utilização em bases de pavimentos. Mesmo assim, as misturas estudadas constituem uma boa alternativa econômica e sócio-ambiental. / Urban paving is of paramount importance for a city, both socioeconomic and in quality of life. The urban flooring not different so-called road surface are constituted by a set of horizontal layers, overlaid on the ground, which have the main function of supporting the actions induced by the vehicle redistributing the stresses transmitted to the ground. Soils are important materials for the execution of paving, mainly because they are part of the basic structure of the floor and mostly be available in abundance, with a very low cost, however, their properties usually do not meet the requirements necessary to perform the floor. The soil stabilization for the implementation of urban pavement bases and sub-bases is an increasingly important aspect in the current situation, because always there is the concern with the environment, and there is now the clear awareness that every effort should be made to minimize the effects caused by the exploitation of deposits and deposition of material. In this sense this work presents the effects of adding different proportions of lime to stabilize a sedimentary soil sample from the urban area of the city of Curitiba. It selected a sample quantity of soil in the region to study the stabilization insertion of hydrated lime type (CHIII) powder. The two variables in the study are related to the content of lime mixed with the soil at 0% percentages of 3%, 6%, 8% and 16%, and cure times at which these mixtures were subjected to (0, 7, 14, 28 and 56 days). The tested mixtures were prepared from dosages defined by two methods: one checking the chemical behavior of the samples by means of changes in pH values, and the second analyzing the mechanical behavior through the RCS values. It has been found that the chemical stability analyzed by addition of lime, provided an average increase of RCS in most soil samples studied, because of some physical and chemical characteristics thereof. For mixtures with 6%, 8% and 16% of lime after 28 days of curing, the average RCS was 0,57 MPa, 1,06 MPa and 2,37 MPa, respectively, for the normal proctor, and as for intermediate proctor, in the same curing time and on the same percentages RCS results were 0,54 MPa, 1,04 MPa and 2,71 MPa, respectively. In global terms, the soil-lime mixtures studied showed acceptable behavior by law to use as layers of sub-base. However, only the mixture with 16% of lime, at 28 days, is recommended for use on floors bases. Even so, the mixtures studied constitute a good alternative economic and socio-environmental.
217

Efeitos da adição da cal hidratada na estabilização de um solo sedimentar para pavimentação urbana na região de Curitiba / Effects of the addition of hydrated lime to stabilize a sedimentary soil for urban paving in the region of Curitiba

Bordignon, Vitor Reinaldo 26 August 2015 (has links)
A pavimentação urbana é de primordial importância para uma cidade, tanto socioeconômica quanto em qualidade de vida. Os pavimentos urbanos não diferentes dos chamados pavimentos rodoviários, são constituídos por um conjunto de camadas horizontais, sobrepostos ao solo, os quais possuem a função principal de suportar as ações induzidas pelos veículos redistribuindo as tensões transmitidas ao solo. Os solos são importantes materiais para a execução de pavimentação, principalmente por fazerem parte da estrutura básica do pavimento e na sua grande maioria se encontrar disponível em abundância, com um custo muito baixo, entretanto, as suas propriedades normalmente não cumprem os requisitos necessários à execução do pavimento. A estabilização de solos para a execução de bases e sub-bases de pavimentos urbanos constitui um aspecto cada vez mais importante no panorama atual, pelo fato de existir sempre a preocupação com o meio ambiente, existindo hoje a clara consciência de que todos os esforços devem ser feitos no sentido de minimizar os efeitos causados pela exploração de jazidas e deposição do material. Neste sentido este trabalho apresenta os efeitos da adição de diferentes proporções da cal para a estabilização de uma amostra de solo sedimentar da região urbana da cidade de Curitiba. Foi selecionada uma quantidade de amostra de solo da região, para o estudo da estabilização com inserção da cal hidratada do tipo (CHIII) em pó. As duas variáveis analisadas no estudo estão relacionadas com os teores da cal misturada ao solo nas porcentagens de 0%, 3%, 6%, 8% e 16%, e os tempos de cura em que estas misturas foram submetidas a (0, 7, 14, 28 e 56 dias). As misturas testadas foram elaboradas a partir de dosagens definidas por dois métodos: um verificando o comportamento químico das amostras, por meio da evolução dos valores de pH, e o segundo analisando o comportamento mecânico através dos valores de RCS. Verificou-se que a estabilização química analisada por meio de adição da cal, proporcionou um aumento médio de RCS na maioria das amostras do solo estudado, em função de algumas características físicas e químicas das mesmas. Para as misturas com 6%, 8% e 16%, da cal aos 28 dias de cura, a média da RCS foi de 0,57 MPa, 1,06 MPa e 2,37 MPa, respectivamente, para o proctor normal, sendo que para o proctor intermediário, com o mesmo período de cura, e nas mesmas porcentagens, os resultados de RCS foram de 0,54 MPa, 1,04 MPa, e 2,71 MPa, respectivamente. De uma forma global, as misturas solo-cal estudadas apresentaram comportamento aceitável pelas normas vigentes para utilização como camadas de sub-base. Contudo, apenas a mistura com 16% da cal, aos 28 dias, é recomendada para utilização em bases de pavimentos. Mesmo assim, as misturas estudadas constituem uma boa alternativa econômica e sócio-ambiental. / Urban paving is of paramount importance for a city, both socioeconomic and in quality of life. The urban flooring not different so-called road surface are constituted by a set of horizontal layers, overlaid on the ground, which have the main function of supporting the actions induced by the vehicle redistributing the stresses transmitted to the ground. Soils are important materials for the execution of paving, mainly because they are part of the basic structure of the floor and mostly be available in abundance, with a very low cost, however, their properties usually do not meet the requirements necessary to perform the floor. The soil stabilization for the implementation of urban pavement bases and sub-bases is an increasingly important aspect in the current situation, because always there is the concern with the environment, and there is now the clear awareness that every effort should be made to minimize the effects caused by the exploitation of deposits and deposition of material. In this sense this work presents the effects of adding different proportions of lime to stabilize a sedimentary soil sample from the urban area of the city of Curitiba. It selected a sample quantity of soil in the region to study the stabilization insertion of hydrated lime type (CHIII) powder. The two variables in the study are related to the content of lime mixed with the soil at 0% percentages of 3%, 6%, 8% and 16%, and cure times at which these mixtures were subjected to (0, 7, 14, 28 and 56 days). The tested mixtures were prepared from dosages defined by two methods: one checking the chemical behavior of the samples by means of changes in pH values, and the second analyzing the mechanical behavior through the RCS values. It has been found that the chemical stability analyzed by addition of lime, provided an average increase of RCS in most soil samples studied, because of some physical and chemical characteristics thereof. For mixtures with 6%, 8% and 16% of lime after 28 days of curing, the average RCS was 0,57 MPa, 1,06 MPa and 2,37 MPa, respectively, for the normal proctor, and as for intermediate proctor, in the same curing time and on the same percentages RCS results were 0,54 MPa, 1,04 MPa and 2,71 MPa, respectively. In global terms, the soil-lime mixtures studied showed acceptable behavior by law to use as layers of sub-base. However, only the mixture with 16% of lime, at 28 days, is recommended for use on floors bases. Even so, the mixtures studied constitute a good alternative economic and socio-environmental.
218

Compactação de um cambissolo háplico com o tráfego de um trator skidder no arraste de pinus elliottii

Pezzoni Filho, José Carlos [UNESP] 31 January 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:20Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-01-31Bitstream added on 2014-06-13T19:00:11Z : No. of bitstreams: 1 pezzonifilho_jc_me_botfca.pdf: 1844947 bytes, checksum: 744ee36bfa2865a4d0115c65f128a2a7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A compactação do solo tem sido considerada como um dos principais danos ocasionados pelas operações mecanizadas de colheita de madeira, sendo que ocorrem danos diretos ao solo, como a compactação do solo (aumento da densidade do solo), diminuição da aeração e da macroporosidade, presença de camada de impedimento ao crescimento radicular, disponibilidade de água, entre outros. Além dos danos diretos ocorrem os indiretos, que são restrição no crescimento das raízes das plantas, onde ocorrerá a diminuição do crescimento da parte aérea da planta, a susceptibilidade do solo ao processo erosivo, devido a camada compactada, entre outros. A extração de madeira com o trator Skidder é a etapa de colheita na qual se deve ter maior atenção, pois esta máquina provoca grandes danos ao solo, tanto pelo seu peso, quanto pelo arraste de árvores e fustes que realizam sulcos (recalques) no solo. Uma forma de diminuir a compactação do solo é deixar camada de resíduos florestais nos ramais de extração de madeira, com isso haverá a minimização do efeito de compressão do solo pelo trator Skidder com o peso da carga arrastada. O objetivo do presente trabalho foi avaliar o nível de compactação do solo até a 5ª vez que o trator Skidder trafegou no ramal secundário de extração de madeira de Pinus (Pinus elliotti var. elliotti). A avaliação da compactação do solo na testemunha (densificação natural) até a 5ª passada demonstrou que houve compactação até a última vez que o trator Skidder trafegou na área, permitindo constatar que o tráfego de máquinas e fuste nas áreas de colheita promove a compactação do solo. Na interação entre os recalques e o número de passadas houve diferença nos níveis de compactação, sendo que com 5 passadas sobre a mesma área, o recalque do pneu apresentou uma menor compactação (1,34 Mg.m-3) quando comparado com o do fuste... / Soil compaction has been considered one of the major damage caused to the operations of mechanized harvesting, and direct damage occurs to the ground as soil compaction (increased bulk density), reduced aeration and macroporosity, the presence Layer impediment to root growth, water availability, among others. Besides the direct damage occurring indirect damages, which are restricting the growth of plant roots, which occur in the reduction of shoot growth of the plant, susceptibility to soil erosion due to the fact that the presence of the compacted layer, between other damage. To minimize such damage recommend carefully planning machinery traffic on the steps of forest harvesting. With this, the logging with tractor Skidder is the stage at which harvesting should be given more attention, because this machine causes significant damage to land, both by weight and the drag tree trunks and carrying grooves (track) in the soil. One way to reduce soil compaction is to leave layer of forest residues on the extensions of logging, thereby minimizing the effect will be to compress the soil by tractor Skidder with the weight of the load dragged.The aim of this study was to evaluate the level of soil compaction until the 5th time that the tractor Skidder the secondary extension of slash pine logging (Pinus elliottii var. Elliotii). The assessment of soil compaction in control (compression natural) until the 5th month showed that there was compaction until the last time that the tractor Skidder traffic in the area, allowing evidence that the traffic machines and tree trunks collection areas promote soil compaction. In the interaction between the track and the number of passes was no difference in levels of compression, with 5 being passed on to the same site, the track of the tire had a lower density (1.34 Mg.m-3) compared to the tree trunks (1.38 Mg.m-3). At both depths studied... (Complete abstract click electronic access below)
219

Efeitos da compactação dinâmica em solo residual / Effects of dynamic compaction in residual soil

Rizzon, Matheus Miotto January 2016 (has links)
Não são raros os casos onde os locais escolhidos para a implantação de determinadas obras não apresentam condições adequadas ou desejadas do ponto de vista geotécnico. Diversas metodologias foram criadas para enfrentar tal problema, seja por substituição de material, realocação da obra, uso de soluções estruturais, melhoria do material, etc. A melhoria de solos utilizando repetições de queda livre de um peso a determinada altura com o intuito de compactar o solo é uma das técnicas mais básicas e antigas que se tem relato. Esse procedimento, quando utilizadas grandes massas e alturas, é conhecido como Compactação Dinâmica. O estudo dessa prática no Brasil é extremamente raro, visto que não é atualmente praticada, apesar da sua ampla utilização mundial. A fim de se conhecer e estudar o comportamento, em termos de resistência e condutividade hidráulica, de solo residual do Estado do Rio Grande do Sul (RS) quando utilizada a Compactação Dinâmica, foi proposto um estudo, em escala real, com o objetivo de avaliar as possíveis melhorias no campo experimental da Universidade de Passo Fundo, na cidade de Passo Fundo – RS. O solo encontrado na região de Passo Fundo possui características interessantes para o estudo da compactação dinâmica, como alto teor de argila, altos índices de vazios e leve cimentação natural. No presente trabalho, foi realizada a compactação dinâmica de campo com massas de 5,5 t e 10,0 t, com alturas de queda de 1,5 a 3,0 m. Nos cinco ensaios realizados, foram feitas medidas do afundamento após cada golpe, bem como coletadas amostras do fundo das crateras. A profundidade estimada de melhoria abaixo do fundo da cratera, de acordo com o modelo de densificação indicado, é de cerca de 3,30 m. Nos ensaios de laboratório realizados nas amostras indeformadas coletadas (natural e pós-compactação), percebeu-se uma redução de duas ordens de grandeza na condutividade hidráulica, passando de 10-5 para 10-7 m/s. Nos ensaios triaxiais, verificou-se aumento da resistência, com ângulo de atrito passando de 26,6o para 35,3o, sem alteração do intercepto coesivo (aproximadamente 14 kPa). Por fim, realizados ensaios oedométricos, pode-se notar que a tensão de plastificação aumentou de 70 para 300 kPa, com mudança significativa do comportamento do material. / Are not rare the situations where the site chosen to build structures does not present good geotechnical soil conditions. Many techniques have been created to deal with this issue, replacing the original soil, change the site, using structural solutions, improving the existing soil, etc. Improving the existing soil using a free falling weight dropped at determined height with the objective to densify the soils is one of the oldest and basic techniques known. Such procedure, when using really heavy masses and high dropping elevations is called Dynamic Compaction (also called Heavy Tamping). The study of this technique in Brazil is extremely rare, since it is not used in the current practice, although it has wide use in the world. With the objective of understanding and studying the behavior, in terms of resistance and permeability, of a residual soil of Passo Fundo (RS) when compacted using Dynamic Compaction, a field and laboratory investigation was proposed. An experimental field, located in the city of Passo Fundo (RS) was the site chosen to execute the proposed study. The soil founded there has some interesting characteristics to the dynamic compaction study, such as high content of clay, a high void ratio and a bonded structure. In the present study, the Dynamic Compaction was executed using steel blocks with 5,5 and 10,0 t. The dropping heights used were 1.5 and 3.0 meters. In the 5 points where the technique was tested, measurements of the displacements where made after each drop of the mass. Undisturbed samples were collected in the bottom of the crater after finished the compaction. The depth of the densified soil, below the crater was estimated at about 3,30 m. According to laboratory tests, a strong reduction of the permeability was observed, from 10-5 to 10-7 m/s. In the triaxials test, the soil showed an increase in strength. The friction angle changed from 26.6º to 35.5º, while the cohesion intercept did not change (approximately 14 kPa). According to oedometric tests, the plastification pressure increased from 70 to 300 kPa, with a change in the behavior of the material.
220

Análise da composição gravimétrica dos Resíduos Sólidos Urbanos (RSU) da região de Santa Maria, pré e pós-triagem / Gravimetric composition analysis of municipal solid waste from Santa Maria region, pré and post separation process

Habitzreuter, Milena Tomasi January 2008 (has links)
Neste trabalho foi estudada a caracterização gravimétrica dos resíduos sólidos da macroregião de Santa Maria (RS). A região estudada é composta pelos municípios de Júlio de Castilho, São Pedro, e pela região da Quarta Colônia, que por sua vez engloba os municípios de Faxinal do Soturno, Nova Palma, São João do Polêsine, Agudo, Paraíso do Sul e Dona Francisca. Os ensaios de caracterização gravimétrica foram realizados na Unidade de Triagem de Paraíso do Sul, município vizinho à Santa Maria no período entre julho e setembro de 2007. Avaliou-se a composição do resíduo in natura e após a triagem de material reciclável e orgânico para que fosse possível analisar a eficiência da triagem e estudar algumas características físicas do rejeito (resíduo sem as porções orgânica e reciclável). A massa de resíduos sólidos urbanos da macro-região de Santa Maria é bastante heterogênea e apresenta variações de acordo com as características sócio-econômicas das regiões. Os resultados da caracterização gravimétrica dos resíduos urbanos mostraram uma significativa influência de fatores externos, tais como a presença de umidade devido ao nível pluviométrico e a ação dos ventos. Isto é devido ao fato que materiais como papel e papelão são descaracterizados em presença de umidade e misturam-se às porções de rejeito e matéria orgânica. A realização da caracterização gravimétrica pré e pós-triagem permitiu uma análise da eficiência da caracterização (ou triagem) feita pela esteira e a verificação do potencial de aproveitamento dos resíduos. A média dos dados analisados indica uma eficiência de cerca de 86 % na triagem efetuada pela esteira, sendo que grande parte do material mal caracterizado é matéria orgânica, um material difícil de ser triado e que muitas vezes incorpora-se a outros materiais. O resíduo da região de Santa Maria apresenta um potencial de aproveitamento de 62 %, seja com a triagem de recicláveis, seja com a compostagem da matéria orgânica. Foi feito um ensaio de compactação no material de rejeito da esteira, o qual foi compactado em prensa estática com uma pressão equivalente de 250 kPa, obtendo-se um fardo com densidade de 7, 66 kN/m3 (ou cerca de 750 kgf/ m3). Este fardo de rejeito apresentou uma consistência firme que permitiu seu manuseio sem necessidade de reforços, mas seu elevado peso dificultou as operações de transporte. Este rejeito compactado não tinha uma significativa quantidade de material orgânico, e por isso, a compactação não gerou líquido (chorume) em quantidade significativa. A compactação do rejeito proporcionou uma redução volumétrica da ordem de 3,2 vezes. / On this work the gravimetric composition of solid wastes from Santa Maria (RS) region was studied. The region is composed by the towns of Júlio de Castilho and São Pedro and by the so-called Quarta Colônia, composed by Faxinal do Soturno, Nova Palma, São João do Polêsine, Agudo, Paraíso do Sul e Dona Francisca towns. The tests were carried out at the Separation Unity of Paraíso do Sul, close to Santa Maria town, which receive the municipal waste of the region. The gravimetric characterization tests were carried out from July to September 2007. The composition of the waste was determined just after arrival and also after the separation of organic matter and recyclables, in order to study the efficiency of the separation process and analyze some physical characteristics of the waste with and without these components. The municipal solid wastes from Santa Maria region is heterogeneous and presents variations which are related to socio-economic characteristics of the regions which originated them. The results of gravimetric characterization showed a significant influence of the external factors, such as the presence of humidity, due to rains, and the wind. This is due to the fact that materials like cardboard and normal paper loose their characteristics and aspect in presence of water, getting mixed up with the refuse and organic matter. The characterization carried out pre and post separation of recyclables allowed to examine the efficiency of the separation which is done on the mat and also to make an analysis of the potential of waste reuse. The data average indicates an efficiency of around 86% in the separation process on the mat, being organic matter a large part of the material wrongly classified as refuse, as it is a difficult material to select from the waste and one which easily incorporates into others. The waste from Santa Maria region has a potential of 62% of being reused or through recycling or by composting (organic matter). A compaction test was carried out on the refusal of the mat. The material was compacted statically on a frame with an equivalent pressure of 250 kPa. A block of refuse with unity weight of 7.66 kN/m3 was obtained. This block had a firm consistency and did not require reinforcing to be moved around, but its large weight imposed some difficulties. The refuse had little quantity of organic matter and so the test did not generate significant amount of liquid. The refuse compaction generated a volumetric reduction of 3.2 times.

Page generated in 0.032 seconds