• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 3
  • Tagged with
  • 14
  • 14
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comportamento hidromecânico de solo e das misturas solo-composto utilizados em camadas de cobertura no aterro experimental da Muribeca, Pernambuco

SANTOS, Gerson Marques dos 27 February 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2016-03-30T18:26:27Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DOUTORADO 2015.pdf: 3908748 bytes, checksum: 8a2a87bfded468f094cef82a4194b28a (MD5) / Made available in DSpace on 2016-03-30T18:26:27Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE DOUTORADO 2015.pdf: 3908748 bytes, checksum: 8a2a87bfded468f094cef82a4194b28a (MD5) Previous issue date: 2015-02-27 / FACEPE / Um dos maiores desafios da Engenharia Geotécnica é a identificação de um sistema de cobertura final para aterro de resíduos sólidos urbanos (RSU) com a utilização de materiais de baixo custo, que minimize a infiltração de água e que possa reduzir as emissões de gases de efeito estufa (GEE). Esta pesquisa tem o objetivo de avaliar o comportamento hidromecânico de um solo e da sua mistura com composto orgânico. Amostras do solo da Formação Barreiras e do composto orgânico utilizado na camada de cobertura da célula experimental do Aterro da Muribeca, Pernambuco, foram coletadas. Os ensaios foram realizados em amostras compactadas em campo e em laboratório no solo natural e nas misturas solo-composto nas proporções, em volume, de 3:1 e 1:1. Em campo, foram avaliados o grau de compactação e a resistência de ponta com uso do penetrômetro dinâmico DPL (Dynamic Petermeter Light). Em laboratório, foram realizados ensaios de caracterização física e química. Nas amostras compactadas, em laboratório, na umidade ótima e peso específico aparente seco máximo foram obtidas as curvas de retenção de água no ramo de secagem e de umedecimento (histerese) e realizadas avaliação de velocidade da perda de umidade em relação à sucção, avaliação da resistência ao cisalhamento e da resistência de ponta. As camadas de cobertura de campo foram simuladas em lisímetros com as mesmas espessuras de campo e compactadas nas condições ótimas de laboratório e avaliada a resistência de ponta com uso dos penetrômetros dinâmico (DPL) e estático CPT (Cone Penetration Test). As curvas experimentais de retenção de água foram ajustadas utilizando o modelo de van Genuchten (1980). O solo natural e as misturas solos-composto apresentam granulometria similares constituída de silte de baixa compressibilidade. O acréscimo do composto ao solo natural provocou uma diminuição no peso específico aparente seco, um aumento na umidade ótima, um acréscimo na capacidade de retenção de umidade até a sucção de 1000 kPa, não apresentando diferenças significativas para sucções superiores. O aumento do composto ao solo elevou a saturação de base para valores acima de 50%, tornando as misturas eutróficas (férteis) propícias para o desenvolvimento de vegetais, aumento da histerese e redução da resistência ao cisalhamento e de ponta do solo. A condutividade hidráulica saturada do solo e das misturas solo-composto é da ordem de 10-8 m/s. O perfil formado por uma camada de 0,30 m de solo natural sobreposta por uma camada de 0,30 m de solo-composto na proporção de 3:1 foi o que apresentou melhor capacidade de retenção de água, maior resistência de ponta e ao cisalhamento. / Um dos maiores desafios da Engenharia Geotécnica é a identificação de um sistema de cobertura final para aterro de resíduos sólidos urbanos (RSU) com a utilização de materiais de baixo custo, que minimize a infiltração de água e que possa reduzir as emissões de gases de efeito estufa (GEE). Esta pesquisa tem o objetivo de avaliar o comportamento hidromecânico de um solo e da sua mistura com composto orgânico. Amostras do solo da Formação Barreiras e do composto orgânico utilizado na camada de cobertura da célula experimental do Aterro da Muribeca, Pernambuco, foram coletadas. Os ensaios foram realizados em amostras compactadas em campo e em laboratório no solo natural e nas misturas solo-composto nas proporções, em volume, de 3:1 e 1:1. Em campo, foram avaliados o grau de compactação e a resistência de ponta com uso do penetrômetro dinâmico DPL (Dynamic Petermeter Light). Em laboratório, foram realizados ensaios de caracterização física e química. Nas amostras compactadas, em laboratório, na umidade ótima e peso específico aparente seco máximo foram obtidas as curvas de retenção de água no ramo de secagem e de umedecimento (histerese) e realizadas avaliação de velocidade da perda de umidade em relação à sucção, avaliação da resistência ao cisalhamento e da resistência de ponta. As camadas de cobertura de campo foram simuladas em lisímetros com as mesmas espessuras de campo e compactadas nas condições ótimas de laboratório e avaliada a resistência de ponta com uso dos penetrômetros dinâmico (DPL) e estático CPT (Cone Penetration Test). As curvas experimentais de retenção de água foram ajustadas utilizando o modelo de van Genuchten (1980). O solo natural e as misturas solos-composto apresentam granulometria similares constituída de silte de baixa compressibilidade. O acréscimo do composto ao solo natural provocou uma diminuição no peso específico aparente seco, um aumento na umidade ótima, um acréscimo na capacidade de retenção de umidade até a sucção de 1000 kPa, não apresentando diferenças significativas para sucções superiores. O aumento do composto ao solo elevou a saturação de base para valores acima de 50%, tornando as misturas eutróficas (férteis) propícias para o desenvolvimento de vegetais, aumento da histerese e redução da resistência ao cisalhamento e de ponta do solo. A condutividade hidráulica saturada do solo e das misturas solo-composto é da ordem de 10-8 m/s. O perfil formado por uma camada de 0,30 m de solo natural sobreposta por uma camada de 0,30 m de solo-composto na proporção de 3:1 foi o que apresentou melhor capacidade de retenção de água, maior resistência de ponta e ao cisalhamento.
2

Infiltração de água e emissão de metano em camadas de cobertura de aterros de resíduos sólidos

Lucia Lopes, Regia 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T17:37:54Z (GMT). No. of bitstreams: 2 arquivo5799_1.pdf: 6941165 bytes, checksum: 9e15318a1da77c36a3db470291d46a88 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A disposição de resíduos sólidos em aterros sanitários necessita de tecnologias que minimizem os impactos ambientais gerados nessas unidades. A infiltração de águas e as emissões de biogás em aterros sanitários têm como um dos principais elementos de controle a camada de cobertura final. O objetivo dessa pesquisa foi avaliar a infiltração de água e as emissões de CH4 em três diferentes camadas de cobertura, instaladas em uma célula experimental de aterro de resíduos sólidos, e analisar a influência da configuração construtiva, das características dos materiais e das variações climáticas nesses processos, e no potencial de oxidação CH4. A metodologia compreendeu ensaios de laboratório para caracterização dos materiais, investigação em campo, com medição de infiltração, temperatura e umidade em profundidade das camadas de cobertura e medição de emissão de biogás na superfície da célula. A estimativa de eficiência de oxidação de CH4 foi feita com base na variação da relação CO2/CH4 em perfil. Os resultados da pesquisa permitiram concluir que o comportamento em relação ao fluxo de líquidos e gases em cada camada de cobertura está diretamente relacionado às características construtivas e as variações climáticas, devido à influência dessas variáveis nas condições de saturação do solo. As camadas do tipo metanotrófica e barreira capilar apresentaram maior taxa de infiltração do que a camada convencional, e com relação às emissões de CH4, essas camadas apresentaram emissões seis vezes inferiores às da camada convencional. A camada metanotrófica apresentou uma eficiência de oxidação de CH4 três vezes superior à camada convencional e duas vezes superior à barreira capilar. O teor de matéria orgânica, pH, temperatura do solo e o conteúdo volumétrico de ar foram os parâmetros que mais se relacionaram com as maiores eficiências de oxidação CH4. A vegetação se mostrou um fator decisivo para proteção da camada de cobertura, retendo umidade, aumentando a eficiência de oxidação e reduzindo a emissão de CH4
3

Estudo de emissões de gases em colunas de solo simulando camadas de cobertura oxidativa de aterro sanitário

ARAUJO, Leila Barros 29 July 2014 (has links)
Submitted by Israel Vieira Neto (israel.vieiraneto@ufpe.br) on 2015-03-05T17:54:33Z No. of bitstreams: 2 DISSERTAÇÃO Leila Barros Araújo.pdf: 2405626 bytes, checksum: a448c1457dc45f59cc3518f2e48fedd4 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T17:54:33Z (GMT). No. of bitstreams: 2 DISSERTAÇÃO Leila Barros Araújo.pdf: 2405626 bytes, checksum: a448c1457dc45f59cc3518f2e48fedd4 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2014-07-29 / Os aterros sanitários são grandes emissores de gás metano, por isso, devem possuir sistemas capazes de diminuir as emissões através do aproveitamento, queima e/ou drenagem do metano. Neste sentido, as camadas de cobertura contribuem para reduzir as emissões fugitivas que escapam por elas. Assim, são realizados estudos para encontrar camadas alternativas com o uso de compostos orgânicos, que através das bactérias metanotróficas, podem oxidar o metano, aumentando a eficiência da camada, como realizado nessa pesquisa. O presente trabalho objetivou analisar a eficiência da oxidação do metano, através da amostragem dos gases em diferentes pontos de uma coluna experimental, simulando a camada de cobertura utilizada em uma célula experimental de um aterro sanitário. A coluna foi confeccionada com segmentos de tubo plástico rígido com diâmetro interno de 15 cm e altura total de 75 cm. A coluna foi preenchida com 30 cm de solo compactado sobreposta com 30 cm de mistura de 50% de solo mais 50% de composto orgânico e instrumentada com sensores para medir temperatura, condutividade elétrica e umidade, com os dados armazenados em datalogger. O fluxo de gás metano injetado foi de 0,5 NL/h controlado por rotâmetros e feita leitura dos gases com o detector portátil de gases. Após os ensaios, foi verificado que a mistura de solo+composto utilizada mostrou-se adequada para a oxidação, mas não se pode concluir que todo o gás metano foi oxidado, e sim que há uma tendência de oxidação na camada, onde a coluna reteve, em média, 60% do gás metano injetado.
4

Estudos de camadas de cobertura de aterros sanitários em colunas de solos

Costa, Magdalena Duarte 15 February 2015 (has links)
Submitted by Isaac Francisco de Souza Dias (isaac.souzadias@ufpe.br) on 2015-10-22T17:23:00Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE_MAGDALENA_COSTA.pdf: 3688505 bytes, checksum: d20d96f6d73982be0deb98b9a764dc21 (MD5) / Made available in DSpace on 2015-10-22T17:23:00Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) TESE_MAGDALENA_COSTA.pdf: 3688505 bytes, checksum: d20d96f6d73982be0deb98b9a764dc21 (MD5) Previous issue date: 2015-02-15 / Facepe / As camadas de cobertura de aterros sanitários são construídas para impedir a saída de gases para a atmosfera e a entrada de líquidos no interior do aterro, minimizando os impactos no meio ambiente. Para melhor desempenho destas é necessário se conhecer os materiais que as compõem. A implantação de novos aterros em todo o País torna a busca por materiais para cobertura em suas proximidades mais rara e consequentemente mais onerosa. Os projetos de camadas de cobertura alternativas são executados utilizando conhecimentos técnicos e fazendo uso de materiais diversos como misturas de solos naturais e materiais com alto teor de matéria orgânica melhorando a oxidação dos gases produzidos e a retenção de líquidos para seu interior. O principal objetivo deste trabalho é estudar em laboratório, através de ensaios de colunas de solos, o desempenho de duas camadas de cobertura compreendendo o comportamento dos solos em função do fluxo de líquidos e gases. As colunas utilizadas foram preenchidas seguindo perfis adaptados da célula experimental construída no Aterro da Muribeca: Coluna 1 – camada convencional: 0,60 m de solo compactado; Coluna 2 – camada oxidativa: 0,30 m de solo compactado, sobreposta a uma camada de 0,30 m de solo+produto compostado na proporção de 1:1 (v/v). As colunas foram feitas com segmentos de tubo PVC rígidos com diâmetro interno de 0,15 m. O gás utilizado para avaliação das emissões foi o metano com fluxo de 0,5 l/h (8,3 ml/min ou 486 g/m2.dia). Para infiltração de água foi feita simulação de chuva e a quantidade de água imposta a coluna foi de 40 mm de chuva em um dia. Os ensaios foram divididos em três fases: verificação das emissões gasosas na umidade ótima; infiltração de água no solo; e injeção novamente do gás metano e água para avaliar as emissões gasosas após aumento da umidade dos materiais. Os resultados mostraram que as colunas analisadas conseguiram mitigar os fatores que afetam as camadas de cobertura que são a emissão de gás e a retenção de líquido. No entanto, quanto à retenção de metano, a Coluna 2 mostrou-se mais eficiente em reter e oxidar o gás metano, minimizando ainda mais sua emissão e a coluna 1 apenas reteve o gás. Quanto a retenção de líquidos a Coluna 2 apresentou melhor desempenho na capacidade de retenção de água em relação a Coluna 1. A mistura solo+produto compostado na proporção 1:1 em volume apresentou um bom desempenho para compor uma camada oxidativa, conseguindo amenizar os problemas inerentes as camadas de cobertura, que são a minimização da emissão de gás para atmosfera e o aumento da retenção de líquidos na camada.
5

Camada de cobertura de aterro de resíduos sólidos: estudo preliminar de casos / Solid waste landfill cover layer: preliminary study of cases.

Isabela Maria Barroso 18 March 2008 (has links)
Apresenta uma revisão sobre os conceitos teóricos de solos não saturados e sobre camadas de cobertura de Aterro. Ressalta a tecnologia de utilização de camadas evapotranspirativas e apresenta os tipos existentes desta camada. / It is a review about the non saturated soils concepts and waste landfill cover system. It points out the technology of using evaptranspirative cover systems and presents the existing kinds of this covers.
6

Camada de cobertura de aterro de resíduos sólidos: estudo preliminar de casos / Solid waste landfill cover layer: preliminary study of cases.

Isabela Maria Barroso 18 March 2008 (has links)
Apresenta uma revisão sobre os conceitos teóricos de solos não saturados e sobre camadas de cobertura de Aterro. Ressalta a tecnologia de utilização de camadas evapotranspirativas e apresenta os tipos existentes desta camada. / It is a review about the non saturated soils concepts and waste landfill cover system. It points out the technology of using evaptranspirative cover systems and presents the existing kinds of this covers.
7

Aplica??o de dois modelos de balan?o h?drico para estudo de Camada de cobertura de aterro sanit?rio utilizando solo e Res?duo da constru??o civil (RCC)

Rios, Daiane do Carmo 14 September 2016 (has links)
Submitted by Ricardo Cedraz Duque Moliterno (ricardo.moliterno@uefs.br) on 2017-07-12T01:22:06Z No. of bitstreams: 1 Disserta??o Daiane do Carmo.pdf: 4697687 bytes, checksum: a37b7f9d37bd854f2fb6862074c46fd4 (MD5) / Made available in DSpace on 2017-07-12T01:22:06Z (GMT). No. of bitstreams: 1 Disserta??o Daiane do Carmo.pdf: 4697687 bytes, checksum: a37b7f9d37bd854f2fb6862074c46fd4 (MD5) Previous issue date: 2016-09-14 / Funda??o de Amparo ? Pesquisa do Estado da Bahia - FAPEB / The water balance is an important aspect on development of a landfill project, and the choice of material for the cover layer will influence the generation of percolated liquids. Considering the composition and characteristics of cover layers, it becomes necessary the conventional material substitution. Therefore, this study compared the construction civil waste (CCW) to the soil from the university campus - UEFS in Feira de Santana/BA as used in evapotranspiration cover layer for landfill, using the water balance models Fenn et al. (1975) and S?o Mateus et al. (2012). The results showed that both materials have the same behavior for the Fenn et al. (1975) method, where the CCW generates less liquid than MSW to the ground. By the method of S?o Mateus et al. (2012), the CCW and the soil allow the passage of water to the MSW in different behaviors, and the soil promoted greater liquid infiltration, about 95.5% higher than the CCW. When the methods were compared, S?o Mateus et al. (2012) presented higher water infiltration to the MSW in the simulation with the soil, in relation to the method of Fenn et al. (1975), and smaller with the CCW, this occurs due to the distinction of the input parameters for the materials, highlighting the influence of the permeability coefficient in the water balance. / O balan?o h?drico ? parte importante no processo de elabora??o de um projeto de aterro sanit?rio, visto que a escolha do material para a camada de cobertura influenciar? na gera??o de l?quidos percolados. Tendo em vista a necessidade da utiliza??o de materiais para a composi??o das diversas camadas dos sistemas de cobertura, torna-se indispens?vel o estudo de materiais alternativos para a substitui??o dos materiais usados originalmente. Para tanto, este trabalho comparou o res?duo da constru??o civil (RCC) com o solo do campus universit?rio da UEFS em Feira de Santana/BA utilizados como camada de cobertura para aterro sanit?rio, utilizando os modelos de balan?o h?drico de Fenn et al. (1975) e S?o Mateus et al. (2012). Os resultados mostraram que, pelo m?todo de Fenn et al. (1975), ambos os materiais possuem comportamento semelhante, sendo que o RCC infiltrou menor quantidade de ?gua para o res?duo s?lido urbano (RSU) do que o solo. Pelo m?todo de S?o Mateus et al. (2012), o RCC e o solo permitem a passagem de ?gua para o RSU em comportamentos distintos, sendo que o solo promoveu maior infiltra??o de l?quidos, cerca de 95,5% maior do que o RCC. Quando comparados os m?todos, S?o Mateus et al. (2012) apresentou maior infiltra??o de ?gua para o RSU na simula??o com o solo, com rela??o ao m?todo de Fenn et al. (1975), e menor com o RCC, isto ocorre devido ? distin??o dos par?metros de entrada para os materiais, destacando-se a influ?ncia do coeficiente de permeabilidade no balan?o h?drico.
8

Avaliação de emissões fugitivas de biogás na camada de cobertura do aterro sanitário da CTR de Nova Iguaçu e do Lixão de Seropédica, Rio de Janeiro. / Monitoring and evaluation of biogas emission through the final cover layer of the waste treatment center of Nova Iguaçu and Dump of Seropédica, Rio de Janeiro.

Ana Carolina Eugênio de Oliveira 17 April 2013 (has links)
No Brasil, se espera ter até 2014, de acordo com o prazo da Política Nacional de Resíduos Sólidos, todos os lixões erradicados e os resíduos sólidos urbanos gerados depositados em aterros sanitários. Atualmente, os projetos de aterros sanitários dão oportunidade para um nicho de mercado, o da fonte de geração de energia. Um parâmetro de controle da poluição do ar causada pelos aterros sanitários são as chamadas camadas de cobertura. Nesse contexto, é de fundamental importância o estudo de camadas de cobertura de resíduos por ser um importante elemento de projeto para evitar ou minimizar a poluição do ar devido aos gases gerados em aterros sanitários de resíduos sólidos, já que é o elo existente entre o ambiente interno dos resíduos e a atmosfera. A presente pesquisa aborda o comportamento dos gases em relação à camada de cobertura existentes na CTR de Nova Iguaçu e no Lixão remediado de Seropédica. Foram realizados ensaios de Placa de Fluxo, medição de pressão e concentração dos gases no contato solo-resíduo e emissões dos gases pelos drenos, além das análises de solo in situ e em laboratório. Os ensaios foram realizados de outubro a novembro de 2012. Os resultados indicaram uma inexistência de fluxo de gases pela camada de cobertura, que possui 1,10 m de espessura, do lixão de Seropédica, sendo encontrado apenas fluxo nos drenos. Na CTR Nova Iguaçu, foi verificada que praticamente a inexistência de fluxo de gases com o sistema de gás ligado, mesmo possuindo uma camada de cobertura de 0,8 m. / In Brazil, according to the timeframe given by the National Policy of Solid Waste, by 2014, every dump will be eradicated and every municipal solid waste generated will be deposited in landfills. Currently, the landfill projects provide an opportunity for the market, which is a source of energy. A parameter of control of the air pollution caused by landfills is called cover layers. In this context, it is important the study of the cover layers to avoid or minimized the air pollution due to gases generated in landfills, which is the link between the solid waste and the atmosphere. This research addresses the behavior of the gases in relation to the cover layers on the CTR Nova Iguaçu and Dump of Seropédica. Six test trials of the Flux chamber, pressure measurement and concentration of gases in the soil-residue contact and emissions of gases through the drains, in addition to in situ soil analysis and laboratory analysis. The tests trials were performed from October, 2012 to November, 2012. The results indicated no gas flow through the cover layer, which has a thickness of 1.10 m, of the dump of Seropédica, where the gas flow was only encountered through the drains. In CTR Nova Iguaçu, the gas flow was almost inexistent, even having a cover layer of thickness of 0.8 m.
9

Avaliação de emissões fugitivas de biogás na camada de cobertura do aterro sanitário da CTR de Nova Iguaçu e do Lixão de Seropédica, Rio de Janeiro. / Monitoring and evaluation of biogas emission through the final cover layer of the waste treatment center of Nova Iguaçu and Dump of Seropédica, Rio de Janeiro.

Ana Carolina Eugênio de Oliveira 17 April 2013 (has links)
No Brasil, se espera ter até 2014, de acordo com o prazo da Política Nacional de Resíduos Sólidos, todos os lixões erradicados e os resíduos sólidos urbanos gerados depositados em aterros sanitários. Atualmente, os projetos de aterros sanitários dão oportunidade para um nicho de mercado, o da fonte de geração de energia. Um parâmetro de controle da poluição do ar causada pelos aterros sanitários são as chamadas camadas de cobertura. Nesse contexto, é de fundamental importância o estudo de camadas de cobertura de resíduos por ser um importante elemento de projeto para evitar ou minimizar a poluição do ar devido aos gases gerados em aterros sanitários de resíduos sólidos, já que é o elo existente entre o ambiente interno dos resíduos e a atmosfera. A presente pesquisa aborda o comportamento dos gases em relação à camada de cobertura existentes na CTR de Nova Iguaçu e no Lixão remediado de Seropédica. Foram realizados ensaios de Placa de Fluxo, medição de pressão e concentração dos gases no contato solo-resíduo e emissões dos gases pelos drenos, além das análises de solo in situ e em laboratório. Os ensaios foram realizados de outubro a novembro de 2012. Os resultados indicaram uma inexistência de fluxo de gases pela camada de cobertura, que possui 1,10 m de espessura, do lixão de Seropédica, sendo encontrado apenas fluxo nos drenos. Na CTR Nova Iguaçu, foi verificada que praticamente a inexistência de fluxo de gases com o sistema de gás ligado, mesmo possuindo uma camada de cobertura de 0,8 m. / In Brazil, according to the timeframe given by the National Policy of Solid Waste, by 2014, every dump will be eradicated and every municipal solid waste generated will be deposited in landfills. Currently, the landfill projects provide an opportunity for the market, which is a source of energy. A parameter of control of the air pollution caused by landfills is called cover layers. In this context, it is important the study of the cover layers to avoid or minimized the air pollution due to gases generated in landfills, which is the link between the solid waste and the atmosphere. This research addresses the behavior of the gases in relation to the cover layers on the CTR Nova Iguaçu and Dump of Seropédica. Six test trials of the Flux chamber, pressure measurement and concentration of gases in the soil-residue contact and emissions of gases through the drains, in addition to in situ soil analysis and laboratory analysis. The tests trials were performed from October, 2012 to November, 2012. The results indicated no gas flow through the cover layer, which has a thickness of 1.10 m, of the dump of Seropédica, where the gas flow was only encountered through the drains. In CTR Nova Iguaçu, the gas flow was almost inexistent, even having a cover layer of thickness of 0.8 m.
10

Análise do desempenho de um solo compactado utilizado na camada de cobertura de um aterro sanitário.

ARAUJO, Pabllo da Silva. 12 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-12T20:13:37Z No. of bitstreams: 1 PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5) / Made available in DSpace on 2018-04-12T20:13:37Z (GMT). No. of bitstreams: 1 PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5) Previous issue date: 2017-03-29 / Capes / Uma das formas de tratamento de Resíduos Sólidos Urbanos (RSU) que mais se destaca são os aterros sanitários, que possui como vantagens, a facilidade de operação, menor custo quando comparado às outras técnicas (triagem, tratamento biológico, incineração, entre outras) e a existência de um plano de monitoramento contínuo. O aterro sanitário utiliza uma camada de cobertura final de solo compactado com a finalidade de isolar os resíduos do meio externo, minimizar a entrada de água para o interior do maciço sanitário, reduzir as emissões de gases para a atmosfera, evitar a proliferação de roedores e vetores de doença, entre outras. As Normas Brasileiras não regulamentam o tipo de solo a ser utilizado, nem técnicas de execução de camadas de coberturas de aterros, nem a forma de monitoramento, possuindo como única exigência o atendimento de um coeficiente mínimo de permeabilidade à água. Diante disso, este trabalho tem como objetivo analisar o desempenho do solo compactado utilizado na camada de cobertura final de um aterro de resíduos sólidos, tendo como campo experimental o Aterro Sanitário de Campina Grande/PB. Para isso foi realizada a caracterização física do solo utilizado na camada, verificação de seus parâmetros quanto à viabilidade para uso em aterros sanitários, análise físico-química e mineralógica, obtenção da curva de retenção de água no solo e análise dos pontos experimentais da curva aos ajustes propostos na literatura. Foi verificado o comportamento do solo frente aos processos de umedecimento/secagem e expansão/contração, observação da relação entre a umidade ótima de compactação e o ponto de entrada generalizada de ar (GAE), além da verificação da variação da umidade do solo em um perfil experimental da camada de cobertura por meio de sensores capacitivos. Os resultados demonstraram que, o solo possui permeabilidade à água admissível para uso em aterros sanitários segundo as normas nacionais e internacionais. O ajuste da curva de Van Genuchten aos pontos experimentais da curva de retenção atendeu às condições de concordância a partir dos parâmetros estatísticos analisados. A umidade ótima de compactação do solo possui valor próximo ao GAE, onde se inicia a dessaturação do solo, no qual o ar começa a entrar nos maiores poros formados pela drenagem da água e perda de umidade. Deve-se realizar a compactação do solo na energia proctor normal obedecendo à adição de água suficiente para atingir a umidade ótima, em um intervalo aceitável de ± 2%. Pode-se concluir que, o tipo de camada de cobertura final (solo argiloso compactado) utilizado é inadequado para a região do aterro devido às características climatológicas a que o solo está submetido e a ausência de proteção vegetal superficial. A aplicação da energia proctor normal para compactação do solo da camada de cobertura do aterro sanitário proporciona condições favoráveis à redução da permeabilidade à água do solo. A curva de retenção de água no solo da camada de cobertura do aterro sanitário apresenta comportamento unimodal e possui características de um solo argiloso. A utilização de sensores capacitivos se mostrou como uma técnica eficaz para aquisição automática da umidade do solo e verificação da sua variação ao longo do tempo, bem como, o monitoramento da sucção pela espessura da camada de cobertura final de solo compactado. / One of the forms of treatment of Municipal Solid Waste (MSW) is the landfill, which has the advantages of ease of operation, lower cost when compared to other techniques (sorting, biological treatment, incineration, among others) and the existence of a continuous monitoring plan. The landfill uses a final cover layer of compacted soil to isolate residues from the external environment, minimize the entry of water into the landfill, reduce the emission of gases into the atmosphere, prevent the proliferation of rodent and vectors of disease, among others. The Brazilian Regulations do not regulate the type of soil to be used, nor techniques for implementing layers of landfills, nor the form of monitoring, having as sole requirement the attendance of a minimum coefficient of water permeability. The objective of this work is to analyze the performance of the compacted soil used in the final cover layer of a landfill, with the Landfill Campina Grande/PB as an experimental field. The physical characterization of the soil used in the layer, verification of its parameters regarding the feasibility for use in landfills, physical-chemical and mineralogical analysis, obtaining the water retention curve in the soil and analysis of the experimental points of the curve were performed adjustments proposed in the literature. The behavior of the soil was verified in relation to the wetting/drying and swell/contraction processes, observation of the relation between the optimum compaction humidity and the Generalized Air Entry (GAE), besides the verification of soil moisture variation in one experimental profile of the cover layer by means of capacitive sensors. The results showed that the soil has permeability to water admissible for use in landfills according to national and international standards. The adjustment of the Van Genuchten curve to the experimental points of the retention curve met the conditions of agreement from the statistical parameters analyzed. The optimum soil compaction humidity has a value close to GAE, where soil desaturation begins, in which the air begins to enter the larger pores formed by water drainage and moisture loss. Soil compaction must be carried out in normal proctor energy by adding sufficient water to achieve optimum moisture, within an acceptable range of ± 2%. It can be concluded that the type of final cover layer (compacted clay soil) used is unsuitable for the landfill region due to the climatological characteristics to which the soil is subjected and the absence of surface vegetation protection. The application of normal proctor energy to soil compaction of the landfill cover layer provides favorable conditions for the reduction of soil water permeability. The water retention curve in the soil of the final cover layer of the landfill presents unimodal behavior and has characteristics of a clay soil. The use of capacitive sensors proved to be an effective technique for automatic acquisition of soil moisture and verification of its variation over time, as well as the monitoring of suction by the thickness of the final cover layer of compacted soil.

Page generated in 0.067 seconds